Short information Parameters are programmed via front-side membrane keypad



Similar documents
Preset Counter signo 721

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Digital Pressure Measuring Instrument MDR480

Analog signal converters CC-E I/I Current / current isolators

ERMA-Electronic GmbH - Max-Eyth-Str Immendingen - Tel: +49(0)7462/ Fax: +49(0)7462/ Technische Änderungen vorbehalten

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

FACTORY AUTOMATION. Manual. Speed Monitor KHU8-DW-1.D

Variable Preset Counter signo 723.1

Multifunction devices

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Duct Humidity Transmitter

Quick Connect. quick - simple - efficient.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Thermistor motor protection

Safety technique. Emergency stop module BO 5988 safemaster

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Contents. Document information

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

Flexible Counter Series in DIN size 24 x 48 mm

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Installation manual. Generator Paralleling Controller GPC multi-line C

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Charge Controller CC611/CC612 Preliminary datasheet

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Electronic Control Devices The European Product Catalogue 2007

Operating instructions. Monitor FR-1 / FR-1N / / 2011

RM4TG20 three-phase network control relay RM4-T - range V

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

RS - SPM. Serial parallel translator module

Power source. Input. Contact / Open collector Voltage input (SELECTABLE) AC V DC12-24V AC V. Output indicator

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Thyristor-controlled power supplies and battery chargers

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Electronic Pressure Switch EDS 300

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

80 Series - Modular timers 16 A. Features

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Maximum Demand Control

ADM1TE 5/30A DIN rail single phase two wire energy meter

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

INSTRUCTION MANUAL VRT-200. TECSYSTEM S.r.l. Via Cristoforo Colombo, 5/C Corsico (MI) phone / Fax:

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Voltage Regulator SPAU 341 C. Product Guide

Three-phase monitoring relay CM-PFE

Modular I/O System Analog and Digital Interface Modules

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Speed Control Relays SX2

Automatic AES Change-Over

Inductive sensor NI10-M18-Y1X-H1141

Disturbance Recoder SPCR 8C27. Product Guide

FIREDEX Conventional Fire Panels

PNOZsigma - Base units

MasterINTERFACE 39 Series - Relay interface modules

DS 600. A contact free flux gate based current measurement sensor 600A rms

Actuator-Sensor-Interface

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Electronic Control Devices The European Product Catalogue 2007

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Frequency Converter Fv

38 Series - Relay interface modules A

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

3-phase, bidirectional energy meter

Energy Management Power Analyzer Type WM14-96 Basic Version

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

38 Series - Relay interface modules A

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

CONFIGURABLE SAFETY RELAYS

48 SERIES Relay interface modules 10 A

GT Sensors Precision Gear Tooth and Encoder Sensors

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Energy Management Energy Meter Type EM23 DIN

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Transcription:

Digital remote display for Flow Meter DM /DE Universal meter UZ Indication of the quantity consumed in m³ Features LED-Display 14.2mm red Indicating range -99999... 999999 0... 3 Decimal points programmable Up- and down counter function 2 digital inputs for summation and subtraction Integrated transmitter-supply 24 / 8V DC Auto-reset or external reset 2 preset outputs SPDT relay (optional), Display conversion programmable Isolated analog output 0/4... 20mA and 0/2... 10V DC (optional) Front protection IP65 General The universal meter UZ has been designed for process engineering and automation environments. All parameters can be programmed. The counter can be used wherever quantities or processes must be measured, displayed and controlled or regulated. Short information Programming Transmitter-supply Parameters are programmed via front-side membrane keypad The integrated transmitter supply allows direct connection of pnp initiators, light barriers, mechanical switch contacts, proximity switches, rotary encoder (24V DC) and Namur initiators (8V DC). Input prescaler An input prescaler has separate programming function for input A and B. Display conversion Preset outputs A separate programmable divisor and factor makes the display adaptable as required. Preset outputs can be programmed as continuous contact or pulse contact. Switching performance is programmable as minimum or maximum function. Analog output Proportional to input pulses an isolated analog output signal 0... 20mA / 0... 10V DC or 4... 20mA / 2... 10V DC can be generated. Start value and end value are programmable. Output changed automatically from current signal to voltage signal, depending on burden. - 1-08.04

Technical Data Power supply Supply voltage : Power consumption : Operating temperature : Rated voltage : Test voltage : CE - Konformität : Input pnp-input : Namur input : Counting frequence max.: Counting delay : Min. pulse width : Transmitter-supply : Display : Indicating range : Additional display : Output Relay: Analog output : : Accuracy : Panel case Dimensions : Weight : Electrical connection : Protection : 230V AC ±10%; max. 3,5VA, with analog output 5VA -10... +55 C 250V~ acc. to VDE 0110 Degree of pollution 2, over-voltage category III 4kV-, between input / output / supply voltage EN55022, EN60555, IEC1000-3/4/5/11/13 Ri = 6,3kΩ switching level: < 4V low; > 8,5V high; hysteresis > 2,5V, max. 35V DC Ri ca 1kΩ (<4mA) switching level: < 1mA low; >2,2mA high; hysteresis > 0,5mA max. 35V DC Input A or B = 15kHz, A and B together = 6kHz, switch contact = 30Hz, 2-channel rotary pulse generator = 8kHz 100µs when reset; 20ms when programming another preselection electronic pulse 50µs, switch contact 5ms 8V DC controlled (Namur), 24V DC (pnp), Ri abt. 150Ω, LED red, 14,2mm -99999... 999999 Digit with leading zero suppression LED 2- digit red, 7mm (parameter - and output indicator) SPDT <250V AC<250VA<2A, <300V DC<50W<2A 0/4... 20mA burden 500; 0/2... 10V burden >500Ω, isolated Automatic output changing (burden dependent) 0,1%; TK 0,01%/K DIN 96x48mm, material PA6-GF; UL94V-0 Front 96x48mm, mounting depth 100mm max. 390g Clamp terminals, 2mm² single wire, 1mm² flexible wire, AWG14 Front IP65, terminals IP20, finger safe acc. BGV A2 (oldvbg4) - 2-08.04

Terminal strip B (varies with version) Terminal strip C (varies with version) 2 preselect (alarm) outputs Analog output Terminal strip D Supply voltage - 3-08.04

Controls and indicators Description Operation of the device is arranged in 2 levels. The requested parameter can be called by button. Selection within a parameter or entering data, use buttons and. Parameters are stored zero-voltage safe in the EEPROM. Button combinations: + one parameter back. + setting parameter to zero or minimum value. After turn on the supply voltage, the device is working in the Working level. Set points of preset outputs can be selected. Activating the button for more than 2 seconds, the program is jumping into the Configuration level. Now all parameters, defining the function of the counter can be programmed. These maybe the measuring input, input configuration, conversion of the displayed value, switching performance of preset outputs and the analog output signal. After finishing the configuration or when longer than 2 minutes no button was pushed, the program jumps back to the working level. Leaving the configuration level is possible at any time when pushing the button for 2 seconds. Error messages: P E Reading this message in the parameter display, parameter failure has been occurred. The display flashes. When pushing one of the buttons the error code will be deleted and the counter is running with factory settings. Configuration and function of the counter must be checked. If error occurs again, please ship the counter to factory for repair service. Loc Programming lock active see configuration page 9 of Overflow also see page 11-4 - 08.04

Start-up note: Before the device can be used, it must be configured for the intended use. see page 6 Notes to representation Parameter only shown when configurated Parameter is only shown when installed in the device (see order code) Note: All parameters can be called if they are not blocked by other programmed parameters and if they are available. Factory settings are shown in [ ]. Working level - 5-08.04

Configuration Level - 6-08.04

- 7-08.04

- 8-08.04

Connection diagramms for flow meter DM/DE 1 input A 1 input A 2 input B - 2 input B 2 1 3 Gnd + 3 2 3 Gnd E1 4 5 reset countkick / stop E200 4 5 reset countkick / stop 6 +24V/8V max. 50mA 6 +24V/8V max. 50mA - 9-08.04

Example of programming for Flow Meter DM/DE Conection on pulser E1 or E 200 Table 1 Parameter Designation / Display Input Input cofiguration FU A-b or A u. B Prescaler input A da 1 Prescaler input B db 1 Transmitter supply In U = 24 V or U = 8 V for Sensor of Namur (E200) Count value for power-on Po restor Decimal point position dp.0 Divisor for display d 1 at E1 ( E200 see Table 2) Factor for display F 1 at E1 ( E200 see Table 2) Start value St. 0 End value En off Switching performence preselect (alarm) output A1 AI Setpoint output A1 AI. Switching performence preselect (alarm) output A2 A2 Setpoint output A2 A2. Analog output Ao Start value for the analog output AS End value for the analog output AE Program lockout LC as required Differing from the above table, by connection on pulse generator E200 of the flow meter, are input following parameter: Table 2 cp-value of the flow meter (Imp./m³) Parameter Designation / Display 5000 500 250 187,5 Prescaler input A da 1 1 1 1 Prescaler input B db 1 1 1 1 Divisor for display d 5000 500 250 1875 Factor for display F 1 1 1 10 Display adjustment from universal meter and flow meter Procedure: For the configuration of the universal counter, you have to put at parameter Start value ( page 7) the present value of the flow meter. If the configuration is finished, the clamps 4 and 6 on terminal strip A, are interconnected transient. Afte the reset, the input value appears on the display. - 10-08.04

Display conversion For some settings of the divisor (d) and factor (f it is possible that the meter will not cover the possible display range of the unit (0-999999). The following formula relationship applies: Maximum display range = 8 x 10 6 x factor (F) should be > 999999 Divisor (d) If this check produces a value of less than 999999, the meter will only be able to count to this display value. The problem can be avoided if the scaler d A or d b is included in the configuration. Example: In a measuring device the flow rate is to be recorded in m³, and displayed without any decimal places. The sensor used supplies one pulse every 0.084 m³. To program the display conversion this sensor constant must first be converted into a fraction. This is as follows: Sensor contact = Factor (F) = 84 Divisor (d) = 1000 Therefore the value 84 must be entered for the factor F and 1000 for the divisor d. However, if we now check the maximum display range, we obtain the following: Maximum display range = 8 x 10 6 x 84 = 672000 1000 This means that the meter can only display up to a maximum value of 672000 at which point it will stop. If this is inadequate it is possible to transfer part of the divisor to the scaler d A or d b. In this case, if the divisor d were to be reduced to 500 the maximum display range would be > 999999, so that the unit could be used to the full extent. The procedure for this is as follows: The divisor d is set to 500 and the scaler d A or d b (depending on which input is used) is set to 2. These settings produce the following: Maximum display range = 8 x 10 6 x 84 = 1344000 500 This means that the display conversion is now configured perfectly for this application. We reserve the right to make technical modifications in the interests of progress. Zentrale Kundendienst-Einsatz-Leitung Further support is available from your G. Kromschröder AG für Deutschland: local branch office/agent. Postfach 28 09 G. Kromschröder AG, Osnabrück The adresses are available on the Internet D-49018 Osnabrück Tel. 05 41/12 14-3 65 G.Kromschröder AG, Osnabrück. Strotheweg 1 Fax 05 41/12 14-5 47 www.kromschroeder.de D-49504 Lotte (Büren) info@kromschroeder.com Tel. 05 41/12 14-0 Fax 05 41/12 14-3 70-11 - 08.04