DEVIreg 330 (+5 to +45 C)



Similar documents
Installation Guide. DEVIreg 530. Electronic Thermostat.

GB/DAS User Instruction

Installation Instructions

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Danfoss Link Mobile Phone Butler

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Product and functional description

HERZ-Thermal Actuators

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Drayton Digistat +2RF/+3RF

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

RM4TG20 three-phase network control relay RM4-T - range V

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

PHOENIX CONTACT Features

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Redundancy Module QUINT-DIODE/40

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Infrarot-Bewegungsmelder IP44

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

BG or BGE Brake Rectifier

MINI MCR-SL-R-UI(-SP)

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

Contents. Document information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Data sheet ECC 12 and 22

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Digital Pressure Measuring Instrument MDR480

PSR The compact range Description

RY2 miniature industrial relays

ACS-30-EU-EMDR-10-MOD

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Installation & User Instructions

48 SERIES Relay interface modules 10 A

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Manual. Solar Fountain Mobile Phone Charger

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Thermistor motor protection

T0118 T2118 T3118. Instruction Manual

SYSTEM DESCRIPTION Termination Boards

Emergency lighting units EM powerled

Quick Connect. quick - simple - efficient.

Actuator for modulating control AME 435

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

User Manual THR840DUK Digital Thermostat

IO-DIM6 6-Channel, Digital to Analogue Converters

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

US Installation Manual Smappee Monitor

Plug and Socket Devices CES 63 A Series 8579

MULTIFUNCTION TIME RELAY CRM-93H

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

49 Series - Relay interface modules A. Features

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Electric Rotary Actuator - On/Off or programmable control actuator

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Current transformers (CT) & Shunts

B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Installation and maintenance instructions. Danfoss Vent

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

PCS0100en Persy Control Services B.V. Netherlands

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

IO-RM3 3-Stage Relay Module

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Plug-in relays Mini ISO relays

WD-AMX Water Detection Controllers

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Cable Plug acc. to DIN EN , Form A

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

connecdim Gateway G1 Ethernet TCP/IP to DALI

The original heating cable just got better

Operating Instructions. Room temperature controller

EBDSPIR-PRM, EBDSPIR-PRM-IP

ELECTROMAGNETIC DISC BRAKES

Digital input modules

Thermal-Magnetic Circuit Breaker M1-..

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

Transcription:

Installation Guide DEVIreg 330 (+5 to +45 C) Electronic Thermostat www.devi.com

Table of Contents 1 Introduction............... 3 1.1 Technical Specifications..... 4 1.2 Safety Instructions........ 5 2 Mounting Instructions......... 6 3 Settings................. 7 4 Warranty................. 8 5 Disposal Instruction.......... 9 1 Introduction DEVIreg 330 is an electronic thermostat to be installed in electric cabinets with DIN rail attachment. The thermostat must be installed via an all-pole disconnection switch. Either a floor sensor or an external room sensor must be used to measure and control the desired temperature. The thermostat has a button to adjust the temperature setting with a scale from +5 to +45 C. An LED indicator shows standby periods (green light) and heating periods (red light). More information on this product can also be found at: devireg.devi.com Installation Guide 3

1.1 Technical Specifications Operation voltage 220-240V~, 50Hz Standby power consumption Max 0.25W Relay: Resistive load Inductive load Max 16A / 3680W @ 230V cos φ= 0.3 max1a Sensing units NTC 15kOhm at 25 C Sensing values: 0 C 25 C 50 C Hysteresis Ambient temperature Lowering in economy periods Temperature range 42kOhm 15kOhm 6kOhm ± 0.2 C 10 C to +50 C -5 C +5 to +45 C Cable specification max 1x4mm 2 or 2x2,5mm 2 Ball pressure temperature 75 C Pollution degree Type Storage temperature 2 (domestic use) 1C IP class 20 DEVIreg 330 (+5 to +45 C) -20 C to +65 C 4 Installation Guide

Protection class Class II - Dimensions Weight 86 x 36 x 58mm 83g The product complies with the EN/IEC Standard "Automatic electrical controls for household and similar use": EN/IEC 60730-1 (general) EN/IEC 60730-2-9 (thermostat) 1.2 Safety Instructions Make sure the mains supply to the thermostat is turned off before installation. IMPORTANT: When the thermostat is used to control a floor heating element in connection with a wooden floor or similar material, always use a floor sensor and never set the maximum floor temperature to more than 35 C. Please also note the following: The installation of the thermostat must be done by an authorized and qualified installer according to local regulations. The thermostat must be connected to a power supply via an all-pole disconnection switch. The sensor is to be considered as live voltage. Have this in mind if the sensor must be extended. Installation Guide 5

5 6 2 7 3 8 N 4 DEVIreg 330 (+5 to +45 C) Always connect the thermostat to continuous power supply. Do not expose the thermostat to moisture, water, dust, and excessive heat. 2 Mounting Instructions Please observe the following placement guidelines: Install the thermostat in an electric cabinet with DIN rail attachment or a separate DIN attachment according to local regulation on IP classes. Do not place the thermostat in a way that it will be exposed to direct sunlight. Follow the steps below to mount the thermostat: 1. Click the thermostat on to the DIN rail attachment. 2. Connect the thermostat according to the connection diagram. Sensor -5 C 1 L 250V~ 16 (1) A Mains 220-240V~ IP20 10T50 D330 +5 C to +45 C 6 Installation Guide

The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector. Note: Always install the floor sensor in a conduit in the floor. 3. Turn on the power supply. 3 Settings If a floor sensor is used, please be aware of the following: The floor temperature is measured where the sensor is placed. The temperature of the bottom of a wooden floor can be up to 10 degrees higher than the top. Floor manufactures often specify the max temperature on the top surface of the floor (usually 27-28 C). Always use a floor sensor to control floor heating. Without a floor sensor, the temperature control may be less accurate and you risk overheating the floor. Installation Guide 7

Thermal resistance [m2k/w] Examples of flooring 0.05 8 mm HDF based laminate 0.10 14 mm beech parquet 0.13 22 mm solid oak plank < 0.17 Max. carpet thickness suitable for floor heating 0.18 22 mm solid fir planks Details > 800 kg/m 3 28 C 650-800 kg/m 3 Approximate setting for 25 C floor temperature 31 C > 800 kg/m 3 32 C acc. to EN 1307 34 C 450-650 35 C kg/m 3 4 Warranty 2 Y E A R 8 Installation Guide

5 Disposal Instruction Installation Guide 9

10 Installation Guide

Danfoss A/S Electric Heating Systems Ulvehavevej 61 7100 Vejle Denmark Phone: +45 7488 8500 Fax: +45 7488 8501 E-mail: EH@DEVI.com www.devi.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. DEVI and the DEVI logotype are trademarks of Danfoss A/S. All rights reserved. 8091289 & VIGDQ102 Produced by Danfoss 07/2012

DEVIreg 330 +5<>+45 140F1072 220-240V~ 50-60Hz~ +5 to +45 C 16A/3680W@230V~ Product Documentation DK EL 7224215315 SE EL 8581185 NO EL 5491481 FI SSTL 3531031 Designed in Denmark for Danfoss A/S 5 703466 209226