Experiment 17: Potentiometric Titration



Similar documents
Chem 1B Saddleback College Dr. White 1. Experiment 8 Titration Curve for a Monoprotic Acid

Experiment 6 Titration II Acid Dissociation Constant

ph: Measurement and Uses

To determine the equivalence points of two titrations from plots of ph versus ml of titrant added.

Acid Base Titrations

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide below. HF (aq) + NaOH (aq) H2O (l) + NaF (aq)

Acid Dissociation Constants and the Titration of a Weak Acid

Lab #10 How much Acetic Acid (%) is in Vinegar?

9. Analysis of an Acid-Base Titration Curve: The Gran Plot

Experiment 4 (Future - Lab needs an unknown)

ph units constitute a scale which allows scientists to determine the acid or base content of a substance or solution. The ph 0

Evaluation copy. Titration of a Diprotic Acid: Identifying an Unknown. Computer

Determining the Identity of an Unknown Weak Acid

Experiment 13: Determination of Molecular Weight by Freezing Point Depression

Titrations. Acid-Base Indicators and Titration Curves. Shapes of Titration Curves. A titration curve is a graphical history of a titration

DETERMINATION OF PHOSPHORIC ACID CONTENT IN SOFT DRINKS

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Chemistry 119: Experiment 7. Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets

Experiment 7: Titration of an Antacid

The Determination of Acid Content in Vinegar

Acid-Base Titrations Using ph Measurements

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

Electrical Conductivity of Aqueous Solutions

EXPERIMENT 10: TITRATION AND STANDARDIZATION

Volumetric Analysis. Lecture 5 Experiment 9 in Beran page 109 Prelab = Page 115

EXPERIMENT INTRODUCTION TO INDICATORS AND ACID-BASE TITRATIONS

GA/7 Potentiometric Titration

POTENTIOMETRIC TITRATION OF A WEAK ACID

Acetic Acid Content of Vinegar: An Acid-Base Titration E10-1

TITRATION CURVES, INDICATORS, AND ACID DISSOCIATION CONSTANTS

Phenolphthalein-NaOH Kinetics

EXPERIMENT 2 THE HYDROLYSIS OF t-butyl CHLORIDE. PURPOSE: To verify a proposed mechanism for the hydrolysis of t-butyl Chloride.

Appendix C. Vernier Tutorial

Determination of the Amount of Acid Neutralized by an Antacid Tablet Using Back Titration

Analyzing the Acid in Vinegar

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Chemistry Laboratory Chemistry THE POTENTIOMETRIC TITRATION OF AN ACID MIXTURE 1

Determination of Citric Acid in Powdered Drink Mixes

EXPERIMENT 12 A SOLUBILITY PRODUCT CONSTANT

Auto-ionization of Water

The introduction of your report should be written on the on the topic of the role of indicators on acid base titrations.

Neutralizing an Acid and a Base

Q.1 Classify the following according to Lewis theory and Brønsted-Lowry theory.

The Determination of an Equilibrium Constant

18 Conductometric Titration

Experiment 2 Kinetics II Concentration-Time Relationships and Activation Energy

Acid-Base Titrations. Setup for a Typical Titration. Titration 1

CHM 130LL: ph, Buffers, and Indicators

3 The Preparation of Buffers at Desired ph

Calcium Analysis by EDTA Titration

Acid Base Titration: ph Titration Curve

Juice Titration. Background. Acid/Base Titration

CHM1 Review for Exam 12

Properties of Acids and Bases

Q.1 Classify the following according to Lewis theory and Brønsted-Lowry theory.

Chemical equilibria Buffer solutions

1. To perform a potentiometric titration of a sample of Liquid Drano with hydrochloric acid.

ACID-BASE TITRATIONS

This value, called the ionic product of water, Kw, is related to the equilibrium constant of water

PERCENT ACETIC ACID IN VINEGAR EXPERIMENT 15

TITRATION OF AN ACID; USING A ph METER. The ph meter is an instrument that measures the ph of a solution and affords a

(1) Hydrochloric acid reacts with sodium hypochlorite to form hypochlorous acid: NaOCl(aq) + HCl(aq) HOCl(aq) + NaCl(aq) hypochlorous acid

STANDARDIZATION OF A SODIUM HYDROXIDE SOLUTION EXPERIMENT 14

Dissolving of sodium hydroxide generates heat. Take care in handling the dilution container.

Experiment 6 Coffee-cup Calorimetry

Chapter 10 Acid-Base titrations Problems 1, 2, 5, 7, 13, 16, 18, 21, 25

Ascorbic Acid Titration of Vitamin C Tablets This lab will be completed individually! Make sure you come prepared!

Health Science Chemistry I CHEM-1180 Experiment No. 12 Acids, Bases, ph, Hydrolysis and Buffers (Revised 05/27/2015)

EXPERIMENT 4 Acid Strength

ph. Weak acids. A. Introduction

TOPIC 11: Acids and Bases

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Potentiometry: The ph Electrode and Potentiometric Titrations

Topic 18 Acids and Bases Exercises

Lab 25. Acid-Base Titration and Neutralization Reactions: What Is the Concentration of Acetic Acid in Each Sample of Vinegar?

AP FREE RESPONSE QUESTIONS ACIDS/BASES

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

ph Measurements of Common Substances

Chapter 17. How are acids different from bases? Acid Physical properties. Base. Explaining the difference in properties of acids and bases

Note: (H 3 O + = hydronium ion = H + = proton) Example: HS - + H 2 O H 3 O + + S 2-

Experiment 3 Limiting Reactants

Lab #11: Determination of a Chemical Equilibrium Constant

Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy

Separation by Solvent Extraction

COMMON LABORATORY APPARATUS

PART I: PREPARATION OF SOLUTIONS AND STANDARDIZATION OF A BASE

Introduction. Depolymerization of Poly(lactic acid) Cups to Lactic Acid. Experiment

Chemistry 52. Reacts with active metals to produce hydrogen gas. Have a slippery, soapy feeling. React with carbonates to produce CO 2

Mixing Warm and Cold Water

Chapter 9 Lecture Notes: Acids, Bases and Equilibrium

LESSON ASSIGNMENT. After completing this lesson, you should be able to: 7-1. Solve basic titration problems.

Name period Unit 9: acid/base equilibrium

1. What do you think is the definition of an acid? Of a base?

CHAPTERS 15 FAKE TEST QUESTIONS. 1. According to the Brønsted Lowry definition, which species can function both as an acid and as a base?

Enzyme Action: Testing Catalase Activity

Chapter 17. The best buffer choice for ph 7 is NaH 2 PO 4 /Na 2 HPO 4. 19)

EXPERIMENT 7 Electrochemical Cells: A Discovery Exercise 1. Introduction. Discussion

Review for Solving ph Problems:

Endothermic and Exothermic Reactions. Evaluation copy. Mg(s) + 2 HCl(aq) H 2 (g) + MgCl 2 (aq)

AP Chemistry 2010 Scoring Guidelines Form B

Transcription:

1 Experiment 17: Potentiometric Titration Objective: In this experiment, you will use a ph meter to follow the course of acid-base titrations. From the resulting titration curves, you will determine the concentrations of the acidic solutions as well as the acid-ionization constant of a weak acid. Introduction You have performed acid-base titrations in the past to determine the concentration of an acidic or basic solution using a colored indicator. However, there are times when an appropriate indicator does not exist, or where the color of the solution would obscure any color change associated with the endpoint. In such cases, a ph meter can be used to monitor the acidity of the solution throughout the titration. Recall the definition of ph: The ph Meter (see Tro, p. 780) ph = log[h 3 O + ] A ph meter consists of two electrodes: a glass electrode, which is sensitive to the concentration of hydronium ions in solution, and a reference electrode. The reference electrode is often a calomel electrode, which supplies a constant potential (E = +0.24 V versus the standard hydrogen electrode) as determined by the half-reaction Hg 2 Cl 2 + 2 e 2 Hg + 2 Cl Calomel is the trivial name for the compound Hg 2 Cl 2. When both the reference and glass electrodes are contained in a single unit, it is referred to as a combination electrode. The potential of the glass electrode is proportional to the logarithm of the ratio of [H 3 O + ] inside and outside the electrode. The ph meter measures the total potential across the two electrodes and displays this measurement on a scale calibrated in ph units. The ph meter is an accurate and easy-to-use device for determining the ph of a solution. You will be using a ph electrode attached to the LabQuest2 interface and computer as a ph meter in this experiment. The appropriate set-up for a potentiometric titration is shown on Figure Page, Expt. 17, along with the details of glass and calomel electrodes. Potentiometric titrations (See Tro, Chapters 15 and 16, especially pp 769-779.) Figure 1 on the next page shows a plot of ph versus volume of base added for the titration of a strong acid with a strong base. There is very little change in ph when the base is initially added. Below the equivalence point, the ph is a function of the amount of excess acid present. Above the equivalence point, the ph is a function of the amount of excess base present. The equivalence point for the titration of a strong acid with a strong base occurs when [OH ] exactly equals [H 3 O + ] in the solution; ph = 7.0. The situation in the case of the titration of a weak acid with a strong base is somewhat different due to the fact that a weak acid is only partially ionized in aqueous solution. A dynamic equilibrium exists, which is represented by the following equation: HA + H 2 O H 3 O + + A

2 Figure 1. Titration curve for the titration of a strong acid with a strong base. The equilibrium expression for this reaction is: or K a = [H 3O + ][A ] [HA] # HA & [ ] [H 3 O + ] = K a % $ [ A ( ] ' Eq. 1 where K a is the acid-ionization constant for the weak acid. Let us assume that the initial dissociation of the weak acid is negligible. The progressive addition of NaOH during the titration decreases the concentration of HA and increases the concentration of its salt, NaA: HA (aq) + NaOH (aq) H 2 O(l) + NaA (aq) The presence of both HA and its salt, NaA, creates a buffer system, which resists a large change in ph (see Tro, pp 754-768). The ratio of [HA]/[A ] changes only slightly; therefore, according to Eq. 1, the change in [H 3 O + ] (or ph) must also be small. The ph increases slowly until the equivalence point is approached (see Figure 2 on the next page). At the halfway point in the titration, exactly half of the HA originally present will have been neutralized, and therefore the concentrations of HA and A will be equal. Substituting this information into Eq. 1, we obtain:

3 equivalence point halfway point Figure 2. Titration curve for the titration of a weak acid with a strong base. K a = [H 3 O+ ] 1/2 [A ] 1/2 [HA] 1/2 K a = [H 3 O + ] 1/2 Eq. 2 Thus, the ionization constant of a weak acid is equal to the hydronium ion concentration at the halfway point in the titration; pk a = ph 1/2 This relationship is valid only if the initial dissociation of the acid is negligible. When the degree of dissociation is appreciable, as in the case of a very dilute solution, the ph at the midpoint of the titration bears no relation to the value of K a. The subsequent rapid increase in ph and the inflection in the titration curve at the equivalence point can be accounted for. As the equivalence point is approached, the concentration of unreacted HA becomes progressively smaller so that successive increments of NaOH neutralize a greater fraction of the HA remaining. This produces a large change in the [HA]/[A ] ratio and, therefore, in the ph of the solution. At the equivalence point, the acid and base have reacted completely to yield the salt, NaA. The ph at the equivalence point is determined by the strength of the base, A. The conjugate base of a weak acid is a strong base. It will react with water to produce hydroxide ions (hydrolysis): A (aq) + H 2 O (l) HA (aq) + OH (aq)

4 For this reason, it is not surprising to see a ph that is greater than 7 at the equivalence point. Beyond the equivalence point, the ph is determined by the ion product for water: K w = [H 3 O + ][OH ] The first small excess of NaOH greatly increases the concentration of OH, concomitantly decreasing the H 3 O + concentration, and causing the ph to continue to increase. Well past the equivalence point, the concentration of OH becomes so large that only slight changes in ph are produced. You will titrate a solution of HCl with a standardized solution of NaOH while measuring the ph throughout the course of the titration. From your titration curve, you will determine the concentration of the HCl solution. You will also titrate a sample of a commercial vinegar using a standard solution of NaOH. The active ingredient in vinegar is acetic acid, which is a weak acid. CH 3 COOH (aq) + H 2 O (l) CH 3 COO (aq) + H 3 O + (aq) The acid-ionization constant of acetic acid is: K a = [CH 3 COO ][H 3 O + ] [CH 3 COOH] =1.74x10 5 M From your titration curve, you will be able to determine the concentration of acetic acid in commercial vinegar.

5 Procedure (you do not need to outline instructions for using the LoggerPro software) Part I. Calibrating the ph Electrode You will use the computer to both acquire and analyze your data from this experiment. Two students will work on the same computer and will obtain the same set of data. A ph electrode should be plugged into Channel 1 of the interface box. Click on the Applications folder at the bottom of the screen. In the window that opens, click on the button labeled Logger Pro to open the Logger Pro software. Under the Experiment menu, choose Data Collection. In the box that appears, click on the drop down menu next to Mode: and choose Events With Entry. In this mode, the computer will record a ph measurement (a y value) every time you click on the mouse. It will then allow you to type in a corresponding x value (volume) after it records the ph measurement. The number of columns should be 1. Next to Name: and Short Name:, type in Volume. Next to Units:, type in ml. Click on Done. The empty graph will now appear with a ph label on the y-axis and a Volume (ml) label on the x- axis. To calibrate the ph electrode, you will need ph 4 and ph 7 buffer solutions. Remove the ph electrode from the bottle in which it is soaking by unscrewing the cap through which the electrode is inserted. You do not need to pull the cap off. Rinse off the ph electrode with a stream of water from a washbottle, shake off the drops and place it in the ph 7 buffer. Swirl the bottle thoroughly. Pull down the Experiment menu and choose Calibrate followed by LabPro: 1 CH1:pH. In the box that appears, click on Calibrate Now. Watch the channel input voltage reading. When the number stops changing, highlight the box under Reading 1 and type 7.0. Click on Keep. Take the ph electrode out of the ph 7 buffer, rinse it off, place it in the ph 4 buffer and swirl the bottle. Wait until the channel input voltage reading is stable (it should be different from the previous voltage reading), then type in 4.0 under Reading 2, and click on Keep. Click OK. The ph electrode is now calibrated. If you close this file or quit the program for any reason, the electrode must be re-calibrated. Click once on the number at the very end of the x-axis. Type in 30 and press return. This will allow the computer to collect data until a total of 30 ml of titrant has been added (you can stop the data collection before 30 ml, if desired). You are now ready to collect data. Part II. Titration of a Strong Acid Into a clean and dry 150 ml beaker, and with a carefully rinsed volumetric pipet, dispense a 10.00 ml aliquot of the 0.5 M HCl solution (do not pipet directly from the bottle). Add exactly 75.0 ml of distilled water and 3 drops of phenolphthalein solution. Fill a clean and carefully rinsed buret with the standardized 0.5 M NaOH solution (record the exact molarity from the label). Record the initial buret reading in your notebook. Remember throughout the experiment that you should record buret readings to the nearest one-hundredth of a milliliter. Remove the ph electrode from the buffer solution. Thoroughly rinse the electrode with distilled water, shake off the drops of water and place it in the acid solution such that the tip is immersed. Stir the acid solution with the ph electrode (be careful not to break the glass tip!). Now arrange the buret over the beaker so that the

6 NaOH can be dispensed directly into the acid solution (see Figure Page, Expt. 17). The tip of the buret should be close enough to the surface of the solution such that no splashing occurs as the base is being added. Click once on the green arrow button. A circular button that is blue will appear next to the red rectangle. Watch the ph reading that appears in the lower left corner of the screen (below the table). When the ph is stable, click on the blue button. At this point, a box appears into which you must enter a value for Volume, that is, the volume of NaOH that has been added as you proceed through the titration. Since you have not added any NaOH at this point, type 0 (zero) and click OK or press return. Begin the titration by adding, with stirring, 1 to 2 ml of NaOH. Be careful not to splash any liquid out of the beaker. When the ph reading is stable, stop stirring, then click on the blue button to record the ph of the solution. Type in the total volume of NaOH that was added (the volume reading on the buret minus the initial volume reading that you recorded in your notebook) and hit return. Continue to add base, record the ph by clicking the blue button and type in the total volume of NaOH added (the new reading on the buret minus the initial volume reading). The ph values should increase in approximately 0.2 ph unit increments. Be certain the solution is stirred after each addition of titrant and that the ph is stable before clicking the blue button. Slow down as you approach the equivalence point! As the ph readings approach 2, reduce the amount of base added to 0.1 ml increments. Record in your notebook the ph reading when the pink phenolphthalein endpoint color persists for 30 seconds. Add increments consisting of several drops of NaOH beyond this endpoint; then increase the increments of base to 1-2 ml until 10 ml more of NaOH has been added. Click on the red button. Important step: Save your data! Save your data by pulling down the File menu and selecting Save As... In the dialog box that appears, the word Documents should be displayed in the drop down menu in the middle of the box. If it is not, scroll through the menu on the left, and choose Documents. Next to the words Save as:, type over the word untitled with the name of your file (example: HClNaOHlao). You should include your initials in the name you choose. Click on Save. To find your file later, you will have to go to the Documents folder. It should have the suffix.cmbl at the end of the file name. A note regarding mistakes : If at any time during the above procedure you type an incorrect volume reading and hit return, simply make a note of the number of the mistake data point in your notebook, along with an explanation of the mistake, and continue with the titration. You can delete unwanted data points or change the volume (x) value for a data point after you have stopped the data collection. If you need to change a volume entry for any of the data points due to a mistake in entering the value, click in the appropriate cell of the Table Window and type in the correct value. To delete a data point, click in the appropriate volume cell of the Table Window and press the delete key. While the ph value for that data point cannot be deleted, the point will no longer appear on the graph once the volume value has been erased. You can adjust the axes on your graph using the AutoScale button in the toolbar or by clicking on the numbers at the ends of the axes and typing in the desired limits.

7 You can adjust other graph parameters in the Graph Options found under the Options menu. Because the Logger Pro program does not draw the smoothest curve through data points but instead simply connects the dots, it is best to print this plot without Connecting the Points, but with Point Symbols. Type an appropriate title for the graph in the box under Title. Your initials should appear in parentheses at the end of the title (so you can identify your printout). Click on OK. To print the graph, pull down the File menu and choose Printing Options. Click in the box next to Print Footer to make sure a check mark appears, then type in your name (and a comment about the plot, if desired). Print both the plot and data table. Use the Print Graph and Print Data Table commands from the File menu. Part III. Titration of vinegar Pull down the Experiment menu and select Store Latest Run. Under the Data menu, choose Hide Data Set followed by Run 1. You can now collect a new data set. Click once on the number at the end of the x-axis, type in 30 and press return. Click once on the number at the bottom of the y-axis, type 0 and return, then click on the upper limit, type 14 and return. Refill the buret with the standardized 0.5 M NaOH solution provided. Record the initial volume of NaOH in your notebook. Using a carefully cleaned and rinsed transfer pipet, dispense a 10.00 ml aliquot of vinegar into a clean, dry 150 ml beaker (do not pipet directly from the bottle). Dilute this aliquot with exactly 75.0 ml of distilled water. Add 3 drops of phenolphthalein solution. Thoroughly rinse the electrode with distilled water, shake off the drops of water and place it in the vinegar solution. Stir the vinegar with the ph electrode (be careful not to break the glass tip!), and arrange the buret above the beaker for a titration. Click on the green button. Titrate the vinegar as you did the HCl solution above. As you approach the equivalence point, decrease the size of the base increments until single drops are being added. Record in your notebook the ph reading when the pink phenolphthalein endpoint color persists for 30 seconds. Continue the titration until a ph of approximately 12 has been reached. Click on the red button, then save your data. Adjust the axes and type in a title for your graph. Print out your plot (without Connecting the Points) and data table. To directly compare the shapes of the two titration curves, choose Show Run 1 from the Data menu, and the plot from your first titration will appear. You can display one or both runs simply by using the Show Run and Hide Run options. You may need to re-adjust axes limits. All of the solutions in this experiment may be poured down the sink. Clean off your lab bench before you leave and return the rinsed ph electrode to the plastic bottle. Record the percent acidity of the vinegar from the label on the bottle. When you are ready to leave, pull down the Logger Pro menu and choose Quit Logger Pro. You should leave the laboratory with printouts of all the necessary plots that you produced today. However, you should also store a copy of your data file(s) by e-mailing the file(s) to yourself. If you need to adjust any of your plots after your lab period is

8 over, you can use the computers in the chemistry teaching labs when the rooms are not occupied (M, W and F at 9:00 1:00 and Tu, Th at 12:00 1:15). Each student must write his/her own Calculations and answers to the Questions for this experiment. Do not hand in one report per pair. Do not hand in identical reports.

9 Calculations 1. a) On the plot resulting from the titration of HCl with NaOH, draw the best curve through the data points by hand. Locate the equivalence point and determine the ph and volume at this point. Label the point where the phenolphthalein endpoint became visible. b) Using the molarity and volume of base solution required to reach the equivalence point, calculate the concentration of the HCl solution that was in the bottle in molarity. 2. a) On the plot resulting from the titration of vinegar with NaOH, draw the best curve through the data points by hand. Locate the equivalence point and note the ph and volume at this point. Label the point where the phenolphthalein endpoint became visible. b) Using the molarity and volume of base solution required to reach the equivalence point, calculate the concentration of acetic acid in the vinegar bottle in molarity. 3. The label on the vinegar states its percent acidity. This quantity corresponds to the mass percent of acetic acid in vinegar (g acetic acid/100 g vinegar). Convert the molar concentration of acetic acid that you obtained to mass percent (note: density of vinegar is 1.008 g/ml). Compare this value to the one reported on the label and calculate the percent error (see Expt. 8). 4. To find the ph at the halfway point of the curve, divide the volume of base needed to reach the equivalence point by 2, and read off the corresponding ph from the titration curve. Determine your experimental value of K a for acetic acid. 5. Using the concentration of acetic acid that you calculated in question 2.b) above along with the literature value for K a given in the introduction (1.74 x 10 5 M), calculate the initial ph of the vinegar sample (after diluting it with 75.0 ml of water but before any base has been added). [Hint: Refer to p. 774 in Tro.] 6. Using your calculated concentration of acetic acid and the literature value for K a, calculate the ph of the vinegar sample at the equivalence point. For the volume of base added at the equivalence point, use the amount determined from your titration curve. Refer to pp 775-776 in Tro. 7. Using your calculated concentration of acetic acid, calculate the ph of the vinegar sample after 25.00 ml of standardized NaOH solution has been added (when the solution is well past the equivalence point). At this point in the titration, you may assume that the ph of the solution depends upon the concentration of OH ions. See p. 777 in Tro. Questions 1. Compare the equivalence point of the first titration (hydrochloric acid) with the endpoint determined by phenolphthalein indicator. If you had determined the equivalence point by the color change of the phenolphthalein, would the value calculated for the concentration of the HCl solution have been larger,

10 smaller or the same as the value you determined by potentiometric titration? Explain. 2. The pk a of carbonic acid (found in carbonated beverages) is 6.1. Which acid is weaker carbonic acid or acetic acid? Explain, using the mathematical expression for K a. 3. Discuss possible error sources and how they might affect your results.