Update: Proposed Medical Device Regulation (MDR) & IVD Regulation (IVDR)



Similar documents
Changes to Medical Device Regulations

Medical Devices. Notified Bodies and the CE certification Process for Medical Devices. European Surgical Robotics Demonstration Day

Want to know more about the Notified Body?

12040/1/15 REV 1 LES/ns 1 DG B 3B

Frequently Asked Questions. Unannounced audits for manufacturers of CE-marked medical devices. 720 DM a Rev /10/02

Guidance on the In Vitro Diagnostic Medical Devices Directive 98/79/EC

Software within the medical device regulatory framework in the EU

How To Know If A Mobile App Is A Medical Device

Medical Device Directive 2007/47/EC What is New? Are we moving towards Drug Rules?

GUIDANCE NOTE FOR MANUFACTURERS OF CUSTOM-MADE MEDICAL DEVICES

UNDERSTANDING THE EC DIRECTIVE 98/79/EC ON IN VITRO DIAGNOSTIC MEDICAL DEVICES

Reporting Changes to your Notified Body

Safeguarding public health The Regulation of Software as a Medical Device

Guide for Custom-Made Dental Device Manufacturers on Compliance with European Communities (Medical Devices) Regulations, 1994

RECALLS in EUROPE. Past, present, near & further future. Gert Bos BSI Medcon May 2012

Preparing for Unannounced Inspections from Notified Bodies

MEDICAL DEVICES SECTOR

DIRECTIVE 2014/32/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

2002 No. 618 CONSUMER PROTECTION. The Medical Devices Regulations 2002

GUIDANCE NOTES FOR MANUFACTURERS OF CLASS I MEDICAL DEVICES

Vigilance Reporting. Vicky Medley - Head of QMS, Medical Devices. September Copyright 2015 BSI. All rights reserved.

European Regulatory Newsletter July - September 2013

Guideline on good pharmacovigilance practices (GVP)

The Regulation of Medical Devices in the UK

Guideline on good pharmacovigilance practices (GVP)

Medical Devices: CE Marking Step-by Step

BSI Unannounced Audits

Emerging Device Topics for Regulatory Consideration.. Janine Jamieson May 2015

WHITEPAPER: SOFTWARE APPS AS MEDICAL DEVICES THE REGULATORY LANDSCAPE

Manual for ITC's clients, Conformity assessment of ACTIVE IMPLANTABLE MEDICAL DEVICES pursuant to Council Directive 90/385/EEC

BSI Road Show: September 8 th to 15 th, 2014

Future Regulatory Challenges for In VitroDiagnostics. Trilateral Workshop, Berlin 16&17 June 2010

EPF Position Statement on the European Commission s proposal for a Regulation on In Vitro Medical Devices

(OJ L 169, , p. 1)

UNIQUE DEVICE IDENTIFICATION. and in the European Union. Laurent SELLES Senior Coordinator for International Relations Health Technology and Cosmetics

MEDICAL DEVICE GUIDANCE

GUIDELINES ON MEDICAL DEVICES

Clinical evaluation Latest development in expectations EU and USA

Konformitätsbewertung 3.9 B 17. Guidance for Notified Bodies auditing suppliers to medical device manufacturers

Med-Info. Council Directive 93/42/EEC on Medical Devices. TÜV SÜD Product Service GmbH

MEDICAL DEVICES INTERIM REGULATION

RECOMMENDATION 2013/473/EU ON NOTIFIED BODIES AUDITS

Guidance Notes for Applicants of the Certificate for Clinical Trial on Medical Device

QUALITY SYSTEM REQUIREMENTS FOR PHARMACEUTICAL INSPECTORATES

NOTICE. Re: GD210: ISO 13485:2003 Quality Management System Audits Performed by Health Canada Recognized Registrars

GMP Issues for Start-Ups, quality in the supply chain and role of the Qualified Person (QP)

How to Use the Design Process to Manage Risk: Elements of Design Controls and Why It Matters

RAPS ONLINE UNIVERSITY

DECISIONS ADOPTED JOINTLY BY THE EUROPEAN PARLIAMENT AND THE COUNCIL

Working Party on Control of Medicines and Inspections. Final Version of Annex 16 to the EU Guide to Good Manufacturing Practice

Conformity assessment certification

End of consultation (deadline for comments) 14 October Adoption by Committee for advanced therapies 15 October 2010

Guideline on good pharmacovigilance practices (GVP)

CE Marking: Your Key to Entering the European Market

QMS for Software as a Medical Device [SaMD] Lessons Learned from a Quality Perspective

Guidance for Industry: Starting Material Supplier Management

COMMISSION REGULATION (EU)

Information Governance and Management Standards for the Health Identifiers Operator in Ireland

Basic Information about the European Directive 93/42/EEC on Medical Devices

DRAFT GUIDANCE DOCUMENT ON THE LOW VOLTAGE DIRECTIVE TRANSITION

GUIDELINES ON MEDICAL DEVICES EVALUATION OF CLINICAL DATA : A GUIDE FOR MANUFACTURERS AND NOTIFIED BODIES

Medical Device Equipment Management.

Medical Device Software Do You Understand How Software is Regulated?

AUSTRALIAN REGULATORY GUIDELINES FOR MEDICAL DEVICES

PLM: Privat Label Manufacturer (Customer of the OEM-PLM relation) OEM: Original Equipment Manufacturer (Supplier of the OEM-PLM relation)

Guide to Distribution of Cosmetic Products in Ireland

COMMISSION DIRECTIVE 2003/94/EC

(ACCORDINGLY TO ARTICLE 11º OF DECREE-LAW N.º 145/2009) INTRODUCTION page 2. ACESS TO THE SYSTEM page 3. NOTIFICATION MANAGEMENT page 4

Pharmacovigilance System Master File (PSMF), QPPV and audits

Schweppes Australia Head Office Level 5, 111 Cecil Street South Melbourne Victoria

TEXTUAL PROPOSAL TECHNICAL BARRIERS TO TRADE (TBT) Article 1 Objective and Scope

By Natalia Wilson, MD, MPH

Draft guidance for registered pharmacies preparing unlicensed medicines

Guidance for manufacturers and Notified Bodies on reporting of Design Changes and Changes of the Quality System

CE Marking Changing & Evolving Requirements September BSI Healthcare Roadshow

Competentes en Medicamentos

Qualified Persons in the Pharmaceutical Industry Code of Practice 2009, updated August 2015

Med-Info Regular Information Bulletins for the Medical Device Industry

Clinical Data for Medical Devices

INTEROPERABILITY UNIT

The EU Clinical Trial Regulation A regulator s perspective

The European Union s EMC Directive 2014/30/EU. Ross Carlton, Sr. EMC Engineer National Instruments

Med-Info. Introduction to Korean Medical Device regulations. TÜV SÜD Product Service GmbH

Agence fédérale des médicaments et des produits de santé

Pre-market Information - Class III and IV

(Text with EEA relevance)

GUIDELINES ON MEDICAL DEVICES

FINAL DOCUMENT. Global Harmonization Task Force. Title: Label and Instructions for Use for Medical Devices

An introduction to the regulation of apps and wearables as medical devices

PRCP CE. Version 5.0 of 16 June Date of entry into force: 1 July 2013

Authorisation and Restriction Newsletter

Medical Device Software

The Danish Energy Agency will carry out inspections in October We will check the CE marking of the smoke alarms you sell or use.

New Guidelines on Good Distribution Practice of Medicinal Products for Human Use (2013/C 68/01)

HOW WILL THE EUROPEAN DIRECTIVE ROHS 2 IMPACT THE MEDICAL DEVICE INDUSTRY? February 2012 SPECIAL REPRINT. By James Calder

Comparative analysis between the possible regulatory approaches to GMP compliance TITOLO PRESENTAZIONE

The right people. The right solution. The first time.

Auditing as a Component of a Pharmaceutical Quality System

GUIDELINES ON MEDICAL DEVICES. IVD GUIDANCES : Borderline issues A GUIDE FOR MANUFACTURERS AND NOTIFIED BODIES

GOOD DISTRIBUTION PRACTICE FOR MEDICAL DEVICES (GDPMD)

Transcription:

Update: Proposed Medical Device Regulation (MDR) & IVD Regulation (IVDR) Paul Brooks Healthcare Solutions

Disclaimer The new regulations are not finalized and subject to change http://medicaldevices.bsigroup.com/en-us/resources/whitepapers-and-articles/ 9/15/2014 2

European Commission Proposal September 2013 After public consultation Build on strengths Balance between pre- and post-market control Flexible Supportive of innovation High safety levels Raid access to market Cost-effective and SME friendly but adapt and improve 15/09/2014 Source Erik Hansson Deputy Head of Unit European Commission DG Health and Consumers 3

European Commission Expectation Towards increased patient safety: Scope of legislation Governance of system and transparency Criteria for designation, monitoring and obligations of notified bodies Risk classification of devices and the safety and performance requirements Obligations of economic operators, including reprocessing of single use devices Clinical evaluation, traceability and reprocessing of single-use devices 15/09/2014 Source Erik Hansson Deputy Head of Unit European Commission DG Health and Consumers 4

European Commission Response to PIP Lesson learned from PIP scandal Amendments from stress test Reinforced control of high-risk devices through a scrutiny mechanism Obligation for manufacturers to provide an implant card ualified person responsible for regulatory compliance Notified bodies to conduct unannounced visits, carry-out physical or laboratory tests and rotate auditors Member States to encourage incident reporting by healthcare professionals and patients 15/09/2014 Source Erik Hansson Deputy Head of Unit European Commission DG Health and Consumers 5

Three Directives become Two Regulations Direct entry into force Three year transition period for MDD/AIMD Three or five year transition period for IVD* Regulation should result in more consistent application *Parliament proposed three year transition for IVDR / industry lobbying for five year 6

Progress! Source MHRA 7

8 Regulation covering MD & AIMD Regulation covering IVD 2013 2014 2015 2016 2017 2018 2019 2020 2021 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 European Parliament 1 ST Reading October 2013 Finalise 1 ST or 2 nd Reading 4 2014 / 1 2015 Designation of Notified Bodies 3 Year Transition 3 Year Transition* Timelines Council discussions ongoing Trilogue asap *IVDR Possibly 3 or 5 year transition

Delegated Entities under the Proposed Regulation European Commission (EC) EU Member States (MS) EU Competent Authorities (CA) Medical Device Coordination Group (MDCG) Medical Device Advisory Committee (MDAC) Assessment Committee for Medical Devices (ACMD) EU Reference Laboratories (EURL) European Medicines Agency (EMA)* Notified Bodies (NB) Special Notified Bodies (SNB)* *EC Need to carefully assess the added value of the EMA involvement 15/09/2014 9

Designation of Notified Bodies & Special NBs Notified Body MDR Class IIa/IIb** IVDR Class B/C *Class I non-sterile / non-measuring **Under MDR Special NB needed for higher risk devices: class III, implantable, devices intended to administer medicinal products 15/09/2014 10

Where M is date in force NB MDD Designation Prior to 2015 M 2015 M to 2018 M 2018 M 2020 M NB MDD Designation Ends NB MDR Designation NB MDR Designation Starts CE MDD Certificates Issued Before 2015 M Valid Until Expiration Date Valid Until Expiration Date Must Expire Prior to 2020 M CE MDD Certificates Issued 2015 M to 2018 M Can Be Issued Must Expire Before 2020 M Must Expire Prior to 2020 M CE MDR Certificates Issued by MDR NB up to 5 Years & Renewable 11

Single-Use Devices Single-use device has been tested and demonstrated impossible to reuse. Devices labeled as single-use should really be single-use All devices should be reusable as a rule, unless they are on a list established by the EC after consultation with MDAC Reusable device suitable for reprocessing for multiple patients/procedures Diverging views between Member States EC proposal balanced approach 12

Economic Operators Economic operators means the manufacturer, the authorised representative, the importer and the distributor Manufacturer means the natural or legal person who manufactures or fully refurbishes a device or has a device designed, manufactured or fully refurbished, and markets that device under his name or trademark Importer means any natural or legal person established within the Union who places a device from a third country on the Union market Distributor means any natural or legal person in the supply chain, other than the manufacturer or the importer, who makes a device available on the market 13

Increased Control of the Supply Chain Crucial Suppliers OEM s Sub contractors Manufacturer Distributers Importers Authorised Representatives 9/15/2014 14

General Obligations of Manufacturer Design and manufacture devices in accordance with the regulation Draw up required technical documentation Complete an appropriate conformity assessment Prepare a declaration of conformity Make technical documentation available to CA s (STED) Operate a quality management system and maintain product conformity Conduct post market surveillance Supply adequate instructions for use in a MS language Procedures for devices that do not comply including vigilance Identify suppliers conducting device design, manufacture Liability insurance 15

Obligations of Authorized Representative, Importers, Distributors Manufacturer designates by written mandate a single authorized representative confirmed in writing by the authorized representative Prescriptive requirements for authorized representative Written process for changing authorized representative General obligations of importers Confirm: manufacturer identifiable and competent, liability insurance, conformity assessment, authorized representative, technical documentation, devices CE Marked, labeled in accordance with regulation Identify themselves, registration, storage & transportation, records, complaints, non-conformity/corrective action responsibilities 16

Eudamed: European Electronic Database UDI Registration of devices and economic operators Information of certificates Clinical investigations Vigilance Market surveillance Public access Allow comparison of devices, economic operators, clinical investigations, vigilance 17

Traceability in the Supply Chain For devices, other than devices for clinical investigation or performance evaluation, economic operators shall be able to identify the following, and will retain records for the 5 years after the last device has been place on the market: (a) any economic operator to whom they have supplied a device; (b) any economic operator who has supplied them with a device; (c) any health institution or healthcare professional to whom they have supplied a device. Unique Device Identification (UDI) To facilitate traceability and recall devices will require a UDI Does not apply to devices for clinical investigation / performance evaluation The UDI will appear on the label Will need to be stored by the economic operators and the health institutions Approved systems will be designated by the Commission Coherent if possible with a global regulatory approach to UDI 18

Person Responsible for Regulatory Compliance Manufacturers within their organisation at least one qualified person who possesses expert knowledge in the field of in vitro diagnostic or medical devices. This will include: a degree or equivalent in natural sciences, medicine, pharmacy, engineering, law plus at least two years of professional experience in regulatory affairs or in MS in medical devices or IVD s or Three years of professional experience in regulatory affairs or in MS relating to medical devices or IVD s Responsible for ensuring: that the conformity of the devices is appropriately assessed before a batch is released that the technical documentation and the declaration of conformity are drawn up and kept up-to-date that vigilance requirements have been fulfilled Subjects in clinical investigations or performance evaluation for interventional studies The qualified person should suffer no disadvantage by performing their duties 19

Classification Changes MDR classification changes Brings AIMD and accessories are class III Identifies spinal disk replacement implants and implantable devices that contact the spinal column are class III Devices incorporating nanomaterial deliberately intended to be released to the human body are class III Sutures and staples used in direct contact with CCS/CNS are not class III 20

uantum Leap IVD Directive IVD Regulation Require a Notified Body Require a Notified Body 80-90% Do not require a Notified Body 80-90% Do not require a Notified Body 21

Declaration of Conformity Manufacturer name and address Statement that the manufacturer is taking responsibility for the device UDI device identifier Device identification name, product code, catalog, Statement of compliance with the regulation Risk classification Harmonized standards used for conformity Notified body, conformity assessment, certificate Place, date of issue Name and function of signature, indication of who on behalf of signs Continuously updated and issued in one of the official EU languages 22

Safety and Clinical Performance Report For all class III and implantable device Based on data collected during the clinical investigation Submitted to Special Notified Body for review Special Notified Body will validate Must be understandable by users in the relevant local MS language The summary will be made available to the public through Eudamed Safety and clinical performance report shall be updated annually with clinical evaluation reports 23

Special Notified Body Assessment of High Risk Devices Only Special Notified Bodies shall conduct conformity assessment of high risk devices MDR class III, implantable, class IIb intended to administer medicinal substance IVDR class D Special Notified Bodies are designated by EMA All applications for high risk devices shall be notified to the EC Notification will include Draft IFU Draft summary of safety and clinical performance Estimated date of completion of conformity assessment EC high-risk devices scrutiny mechanism TBD Notification will be communicated to MDCG Within 20 days MDCG may request prior to CE Marking SNB provide (Under IVDR triggered by three members of ACMD) Clinical evaluation report (IVDR clinical evidence / clinical performance study) Post Market Clinical Follow-up Plan Information on marketing or not in third countries (results of evaluations) 24

Special Notified Body Assessment of High Risk Devices (continued) MDCG will consult ACMD At the latest of 60 days MDCG will issue opinion on documents submitted Within that period <30 days ACMD may request additional information EC high-risk devices scrutiny mechanism TBD Within 15 days of receiving MDCG opinion SNB will indicate whether it agrees If SNB disagrees it has 30 days to submit further information and request re-examination MDCG in consultation with ACMD has a further 30 days to re-examine opinion Following unfavorable opinion SNB shall not issue a certificate SNB can submit new information and MDCG may reassess application Following unfavorable opinion manufacturer can request from EC a hearing to discuss the scientific grounds for the unfavorable scientific assessment The EC will make MDCG opinions available to the public The manufacturer will not be charged for the additional MDCG assessment 25

Parts and Components New requirement for suppliers of parts or components Parts or components intended to replace parts or components that are defective or worn to maintain or re-establish performance of a device Responsibility to determine the part or component does not adversely affect the safety and performance of the device Substantiating evidence available to CA s For implantable devices must cooperate with the manufacturer of the device Part or component that significantly changes the performance or safety characteristics of a device shall be considered a device in its own right. 26

Implant Card and Information about Implantable Devices Manufacturers of implantable devices shall provide implant card for particular patients Implant card shall also be made available in an electronic format Identifies device implanted including UDI Warning, precautions, measures to be taken with reciprocal interference with external influences (e.g. compatibility with diagnostic devices) Potential adverse effects Information on expected life cycle and follow-up Principal characteristics of device including materials Exempted implants: sutures, staples, dental implants, screws, plates 27

Potential Certificate Transition from MDD to MDR EC MDR A Certificate EC MDR Design Examination Certificate Upgrade MS CA from MDD to MDR Assess the gaps (additional requirements) Sample technical files (IIa & IIb) Issue MDR A Cert MDD A Cert may still be required to support MDD DD s Submission of MDR DD (maybe based on MDD DD) New submission for up-classified devices (class III) Include renewal data DD review against MDR requirements Will there be MDCG review?? MS/EC oversight?? Issue EC MDR DE Certificate (post MDR A Certificate) IVDD to IVDR Transition Take account of significant reclassification 28

EU Joint Action Plan for Immediate Action 2 9 Notified Bodies Competence and tasks Reassessment of NB s dealing with high-risk devices Joint audits by MS and EC Post Market MS reinforcement Vigilance coordination EC analysis benchmarking Co-ordination and Transparency Coordinated inspections, trends and analysis International coordination IMDRF Traceability (UDI) 29

Any uestions Paul Brooks Senior Vice President Healthcare Solutions +1-703-464-1923 Paul.Brooks@BSIGroup.com http://medicaldevices.bsigroup.com/ http://medicaldevices.bsigroup.com/en-us/resources/whitepapers-and-articles/ 30

15/09/2014