INSTRUCTION MANUAL OVERVIEW. ---------- Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.



Similar documents
BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

2 Installation Explanation

Tracer-1206RN / 1210RN / 1215RN. Maximum Power Point Tracking Solar Charge Controller INSTRUCTION MANUAL

SNMP Web Management. User s Manual For SNMP Web Card/Box

INSTRUCTION MANUAL EPSOLAR. Tracer-2210RN / 2215RN. Maximum Power Point Tracking Solar Charge Controller

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)

Solar Controller / Battery Charger User s Manual

User's Guide. Pinless Moisture Meter. Model MO257

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

Product catalogue. solar charge controller & inverter BEIJING EPSOLAR TECHNOLOGY CO., LTD. Tel: Fax:

12 Volt 30 Amp Digital Solar Charge Controller

The Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH)

User Guide. Temperature and Humidity Datalogger. Model 42280

OCSM Series. High Resolution Digital Crane Scale. User Guide

Product Specification

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

GSM Autodialer Professional GJD700 Speech & Text Autodialer

FPV MONITOR. User Manual

COLOR TFT LCD MONITOR. User Manual

View Star series. Solar Charge Controller INSTRUCTION MANUAL

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Bluetooth HC-06 with serial port module Easy guide

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

PD 100A. Printing data system

SOLAR POWER - THE NEW WAY TO RV!

User Manual. Humidity-Temperature Chart Recorder. Model RH520

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

magnetronic GmbH Kreuzhofstr München Tel.: 089/ Fax: 089/ Battery control system DCC 6000

Motion Activated Camera User Manual

Video Baby Monitor System. User Guide

HOW TO TRANSFER FILES BETWEEN EEN IDL7000 PVR AND USB2 DEVICE

User Manual WatchPower

Contents & P-LCD Modules Cross Reference Table

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

MAGICAR M871A. Car alarm with two-way remote User s guide

OCS-S High Resolution Digital Crane Scale

Sigma Control PC INSIDE. 97 psi 187 F R on load

Getting to Know Xsight Home Screen and Everyday Use Settings PC Setup

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

GST301. (Single Protection Zone) Operation Manual

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Communication bridge Xcom-MS User Manual

IP5000-series Telephone Quick Reference Guide TOSHIBA. Business Telephones Helping You Communicate Better STRATA CIX

DP5000-series Telephone Quick Reference Guide TOSHIBA. Business Telephones Helping You Communicate Better STRATA CIX

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

How To Control A Battery Cell Phone With A Battery Power Control System

My home Mobile phone application

Advanced Wind/Solar Hybrid Controller. Model: WWS10A-48 Version 1.0

Temperature & Humidity SMS Alert Controller

ST815 Illumination Sensor with LCD

Dual Laser InfraRed (IR) Thermometer

VFS24/32HDIP. Public Display IP Monitor User Manual

User Guide Reflow Toaster Oven Controller

SAFETY WARNINGS. Important Safety Instructions. FCC Notice. Caution

SA-9600 Surface Area Software Manual

Energy Communication Unit (ECU)

En Wireless Mobile Utility (Android) User s Manual. D610, D600, D7100, D5300, D5200, D3300, Df

LCD MONITOR / 8 CHANNEL DVR COMBO

The Battery Saving Charger

Workshop 7 PC Software - Tracker

AquaTrend Interface. Model AquaTrend Model AquaTrend/SOM Model51400 PortableAquaTrend. Instrument Manual. Catalog Number

iloq P10S.10/20 Programming device User's Guide

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

TOUCH SCREEN WEATHER STATION MODEL WS Operation Manual

Powerline 500 WiFi Access Point XWN5001 Installation Guide

SoundLAB Software Download Software from the Bogen website:

T-100-R Installation Guide

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

How To Use An Ip Phone With A Sim Sim Sims 2 (Iphone) Or Ip Phone (Ip Phone) With A Microsoft Ip Phone 2 (Ipphone) With An Ipro (Ipro) Or Sims 1 (Ip

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

My home. Mobile phone application. Instructions for use and installation. For DELTA DORE GSM transmitters and transmitter control units.

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Table of Contents. System Requirement of MP3 Player: Connection and Downloading Downloading DRM10 Files... 8.

T Sentry 4 Multi-Point Digital Alarm Instruction Manual

Your Data Security Guardian. SafeTANK GR5630-WSB3+ User Manual. v.1.0 (Oct, 2012)

How to configure DVR and computer for running Remote Viewer via IP network

KRONOS GA11 WEEKLY-PROGRAMMING DIGITAL CHRONOTHERMOSTAT FOR THE REMOTE CONTROL OF HOT AIR GENERATORS THROUGH BRAHMA INTERFACE BOARD APPLICATION

Fi TV Gold Quick Start Guide

tattletale User Guide Consumer unit version P a g e

Cisco Model SPA 303 Quick Start Guide

Transmitter Interface Program

BLU Vivo 4.3 User Manual

User Manual of WT 493

4-Channel Thermometer / Datalogger

WPR400 Wireless Portable Reader

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

is then retained absolutely without interruption.

HCR3.2/.. Chipcard reader HOTEL SOLUTION

GSM Alarm System User Manual

Energy Communication Unit (ECU)

STERILIZERS, LABORATORY DRYING OVENS

15 Digital Photo Frame Instructional Manual

RADIO CONTROLLED DIGITAL CLOCK MODELS / 88906

Transcription:

INSTRUCTION MANUAL ---------- Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series. OVERVIEW The digital Remote Meter displays system operating information, error indications, and self-diagnostics read-out. Information is displayed on a backlit LCD display. The large numerical display and icons are easy to read and large buttons make navigating the meter menus easy. The meter can be flush mounted in a wall or surface mounted using the mounting frame (included). The MT-5 is supplied with 2m of cable and a mounting frame. The MT-5 connects to the RJ45 port on the Tracer.

MECHANICAL DRAWING CONTAINS Wall mounting board, can be mounted in or on the wall with 2 meter cable.

DISPLAY Solar icon Battery icon Load icon Error indicator Setting icon Data indicator The two LED indicators above the LCD show that battery is charging, and a red indicates error conditions. The LCD has two different brightness levels. After any button is pressed the display will be in high brightness and backlight. To save power, the backlight automatically turns off after 30 seconds.

OPERATION INSTRUCTION The key from left to right is: K1~K4,or Set, Left( ), Right( ), ESC(Load ON/OFF). 1. The meter display as following order: (Solar panel voltage), (battery voltage, battery current), (load voltage, load current), (battery capacity AH, battery temp.), (battery capacity percentage, temp. compensation), (battery capacity AH, battery type), (Load Timer1 mode, Load Timer2 mode), (discharging accumulation AH, discharging accumulation WH) as eight team data. Use K2, K3, or Left, right key for repeating the data for the team. Data shows as following picture. Remarks: MPPT solar controller is Maximum Power Point tracking technology. So the solar panel charging current may not equals to the sum of battery charging current and load current. status. is setting icon. It appears in setting status, and disappears in reading

2. Data setting operation: Reading status, press K1/SET to setting status, press K2, K3 to modify data. K1 for back to reading status and saving data. K4 for back to reading status without saving data. Operation shows as following picture. 3. Data setting instruction Battery capacity modify: capacity modify range from 10AH to 900AH, the default value is 200AH. The modify data should be near or equal to the real capacity. While display battery capacity and temp., press K1 into setting mode, modify the data through K2, K3. Battery capacity will be up/down 10AH, press K1 for saving data and back to the reading status. Or press K4 for back to reading status without saving. The capacity remain the same. Battery temp. compensation: temp. compensation data modify ranges from 0 to 10mV/Cell/, while the data is 0, there is no temp. compensation function. While on displaying battery capacity percentage, temp. compensation, press K1 into setting mode, modify the data through K2, K3. The temp. compensation will be up/down 1 mv/cell/.

Battery type: battery type has three options: SEL-sealed battery, GELgel battery, FLD- flooded battery. While on displaying battery capacity and battery type, press K1 into setting mode, choosing suitable battery type through K2, K3. Load mode: load has two timers: Timer1 and Timer2. While on displaying timer1 and timer2, press K1 into setting mode, choosing expected work mode through K2, K3, press K4 to exit setting mode. When load mode is manual, load can be changed to ON or OFF by pressing K4 button on any display surface. Please refer to the controller user s manual for more information. 4. Other operation: The controller will delete the data automatically while accumulation is over 999. 24-hour data will begin to be accumulated at the moment when solar panel voltage is over 8V for the first time.

OTHER INSTRUCTION Error icon instruction: Red flashing on error status. Please check the load connection, press K4 for delete error icon. 1. When load current over 1.25 times and less than 1.5 times of rated current, load will be off automatically after 60 seconds. 2. When load current over 1.5 times of rated current but less than short circuit, load will be off automatically after 5 seconds. 3. When load current over short circuit, short circuit protection shut the load. LED indicator: Green on when solar is charging battery, green off without charging. Yellow on when there is error. Yellow off in normal status. Telecommunication port: While the meter run by individual power or the communication cut off, it displays graphical symbols. Press key, no answer. The display will resume while communications is on. Note: the data displayed got from the communication, check if the cable correct while the data is error, or if there is strong interference. Too long cable may bring mistakes too. Battery capacity strip flash: Each strip equals to 20% of battery capacity. Note: the calculation takes fully charged voltage as 100%, and over discharge as 0%. All is based on battery voltage, not the real battery capacity.

Data updating: Serial communication happens every 10 seconds between control module and display module, so the data update takes in 10-20 seconds. Battery capacity AH: AH is the accumulation of charging, each one minute will count. The data is not accurate while the charge current is too small. The min. is 0.1AH. Charging and discharging accumulation WH: Solar panel displaying is open circuit voltage. It can t be calculated. WH is product of battery voltage and charging current accumulation. PARAMETERS Remote meter LCD specification Working current Backlight and LED indicator off < 15mA Work temperature -10 to +40 Communication port Communication cable RJ45(8PIN) 2 meters with supplied cable