3 Ranger Pressure Infusor Model 145 Operator s Manual



Similar documents
Covering the Spectrum

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

Zip40 Charging Cart. User's Guide. Components. Tools Needed ENGLISH. For the latest User Installation Guide please visit:

BeoLab 7-1 BeoLab 7-2. Guide

Technical Update TAA.TU Rev. 1

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

HP UPS R1500 Generation 3

Operation Manual FOR & 14030

Model 1756 Test Lead Kit

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

3M Wrist Strap and Footwear Tester 740. User s Guide

EKOS Cart. Instructions for Use

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

Meaco 30L and Meaco 40L dehumidifier instruction manual

Please read and keep these instructions. Run water through your machine before first use

Dehumidifier Users manual. For Models: DH45S DH65S

Use and Care Manual. Model CPA12KH AIR CONDITIONER

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Portable Air Conditioner

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

National- Spencer Inc.

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

Remote Alarm Monitoring System

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

MAINTENANCE & TROUBLESHOOTING

3 Bair Hugger. Service Manual

Manual Ranging MultiMeter

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Tablet Management Rack 16

AutoRanging Digital MultiMeter

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

MIC-WKT and MIC-WKT-IR

VACUUM CLEANER INSTRUCTION MANUAL

Back-UPS Pro 1300/1500 Installation and Operation

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Med-Aire 8 Alternating Pressure Mattress Replacement System With Low Air Loss

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

How To Use A Power Supply Unit (Upu)

Platelet Incubator Operation Manual

Wall-Mounting your HP computer. User Guide

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

BLOOD COLLECTION MIXER

Single Day Alarm Clock with. Bluetooth and USB Play-through

Doorbell Intercom Security System

Anti-decubitus Mattress 418E 516E - 820Z User's manual

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

3 WATT LED SPOTLIGHT Model No. SLM

SVENSKA DANSK NORSK

OPERATOR S MANUAL Vet Pump


FUSION R400 RAID USB 3.0

MAINTENANCE & TROUBLESHOOTING

Convection TCO650. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

Convection TCO600. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

Model 70A00-1. GSM Cellular Communications Center

< HL-290. OPERATOR S MANUAL HOTLINE 2 Fluid Warmer

Dual Cushion User Manual. Specialist Suppliers to the Healthcare Industry

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Achat 115MA full-range speaker. user manual

Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

User s Manual AURORA 1.2K/2.2K

SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / Instruction Manual. Page 1 of 9

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

MCR1900 Media Converter 19-Slot Chassis

PROFESSIONAL POPCORN MAKER

How To Service A Paper Shredder

12-Volt 10-Amp Regulated Power Supply

BroadBand PowerShield. User Manual

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

How To Use A Cdm250 Digital Multimeter

aseries A13B Mini Bullet Camera User Manual

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Multi Tube Rotator. Model No. 4632Q CE CECN /05/11

AM/FM ALARM CLOCK RADIO

San josé OWNER S MANUAL

Installation and Operation Back-UPS 1250, 1300, 1500

BeoLab 1. User s guide

StorTrends 3400 Hardware Guide for Onsite Support

Drayton Digistat +2RF/+3RF

Congratulations! Thank you!

TIG INVERTER INSTRUCTION MANUAL

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

NFC Communication Tray Model: HHX-IT3-Z

Online UPS. PowerWalker VFI 1000R/1U

Model 349KLX Remote Display Digital Scale User Instructions

75th anniversary blender

Gemini II. Subwoofer System OWNERS MANUAL

3000W Power Inverter

Transcription:

3 Ranger Pressure Infusor Model 145 Operator s Manual 1 Ranger Pressure Infusor Model 145 Operator's Manual 2 Dispositif de perfusion sous pression Ranger modèle 145 Manuel d utilisation 3 Ranger Druckinfusor Modell 145 Bedienungsanleitung 4 Infusore a pressione Ranger modello 145 Manuale dell operatore 5 Infusor de presión Ranger, modelo 145 Manual del operador 6 Gebruikershandleiding Ranger-drukinfuus model 145 7 Ranger tryckinfusor modell 145 Användarhandbok 8 Ranger trykinfuser model 145 Brugervejledning 9 Ranger Infusjonsenhet med trykk, modell 145 0 Ranger-paineinfuusori, malli 145 Käyttäjän opas = Ranger Εγχυτήρας Πίεσης Μοντέλο 145 Εγχειρίδιο Χειρισμού H Instrukcja obsługi modelu 145 infuzora ciśnieniowego Ranger J Ranger infúziós pumpa, 145-ös modell használati útmutatója F Tlakový infuzor Ranger, model 145 Návod k obsluze Q Ranger slėgio infuzoriaus 145 modelio operatoriaus vadovas M Компрессионный инфузор Ranger, модель 145 Руководство оператора : Ranger Basınçlı İnfüzör Model 145 Kullanıcı Kılavuzu E レンジャー プレッシャーインフューザー モデル145 オペレーターズマニュアル I Ranger 压 力 输 液 器 145 型 操 作 指 南 دليل مشغل جهاز Ranger لتسريب الضغط طراز U 145 - Manual do Utilizador do Infusor de Pressão Modelo 145

3 Ranger Pressure Infusor Model 145 Operator s Manual English 3 Français 21 Deutsch 43 Italiano 65 Español 87 Nederland 109 Svenska 131 Dansk 153 Norsk 175 Suomi 197 Português 219 Ελληνικά 241 Polski 263 Magyar 285 Česky 307 Lietuvių Kalba 329 Русский 351 Türkçe 373 日 本 語 395 英 语 417 اللغة العربية 439

Revision History Revision Reason for Change Pages Affected Date A New Revision - First Release All May 2013 B Translations added All July 2013

Table of Contents Section 1: Technical Service and Order Placement 3 Technical service 3 USA 3 Order placement 3 USA 3 Proper use and maintenance 3 When you call for technical support 3 Servicing 3 Section 2: Introduction 5 Indications for use 5 Explanation of symbols 5 Explanation of signal word consequences 6 Product description 8 Pressure infusor panel 9 Section 3: Instructions for Use 11 Attaching the pressure infusor to the I.V. pole 11 Load and pressurize the infusors 12 Changing a fluid bag 12 Section 4: Troubleshooting 13 Standby/ON mode 13 Pressure infusor 14 Section 5: Maintenance and Storage 15 Cleaning the Ranger pressure infusor unit 15 To clean the outside of the unit 15 Storage 15 Section 6: Specifications 17 Physical characteristics 17 Electrical characteristics 17 Performance characteristics 18 202041B

Technical Service and Order Placement 3 Section 1: Technical Service and Order Placement Technical service and order placement USA TEL: +1-800-228-3957 Proper use and maintenance 3M assumes no responsibility for the reliability, performance, or safety of the Ranger pressure infusor system if any of the following events occur: Modifications or repairs are performed by unqualified personnel. The unit is used in a manner other than that described in the operator s manual or maintenance guide. The unit is installed in an environment that does not meet the appropriate electrical and grounding requirements. When you call for technical support We will need to know the serial number of your unit when you call us. The serial number label is located on the back of the pressure infusor system. Servicing All service must be performed by 3M Health Care or an authorized service technician. Call 3M Health Care technical service at 800-228-3957 for service information. Outside of the U.S. contact your local 3M Health Care representative. 202041B

4 Technical Service and Order Placement

Introduction 5 Section 2: Introduction Indications for use The 3M Ranger pressure infusor is intended to provide pressure to I.V. solution bags when rapid infusion of liquids is required. Explanation of symbols The following symbols may appear on the product s labeling or exterior packaging. Date of manufacture Manufacturer Protective earth (Ground) Single use only Attention; see instructions for use Electrical shock hazard Sterile; sterilized using ethylene oxide Latex free This system is subject to the European WEEE Directive 2002/96/EC. This product contains electrical and electronic components and must not be disposed of using standard refuse collection. Please consult local directives for disposal of electrical and electronic equipment. Defibrillation-proof type BF applied part VAC V Voltage, alternating current (AC) 202041B

6 Introduction An equipotentiality plug (grounded) conductor other than a protective earth conductor or a neutral conductor, providing a direct connection between electrical equipment and the potential equalization busbar of the electrical installation. Please consult IEC 60601-1; 2005 for requirements. CAUTION: Recycle to avoid environmental contamination This product contains recyclable parts. For information on recycling - please contact your nearest 3M Service Center for advice. Fuse Explanation of signal word consequences WARNING: Indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION: NOTICE: Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Indicates a situation which, if not avoided, could result in property damage only. WARNINGS: 1. To prevent tipping or device damage, the Ranger pressure infusor Model 145 has been designed to only be mounted on a Model 90068/90124 pressure infusor I.V. pole/base. 2. Never infuse fluids if air bubbles are present in the fluid line, as air embolism may result. 3. To reduce the risks associated with hazardous voltage and fire: keep power cord visible and accessible at all times. The plug on the power cord serves as the disconnect device. The wall socket outlet shall be as close as practical and shall be easily accessible. use only the power cord specified for this product and certified for the country of use. do not allow the power cord to get wet. do not use the pressure infusor when it appears the pressure infusor, power cord or any component is damaged. Contact 3M Health Care technical support at 1-800-228-3957. this equipment must only be connected to a supply mains with protective earth. 4. To reduce the risks associated with exposure to biohazards always perform the decontamination procedure prior to returning the pressure infusor for service and prior to disposal. 5. To prevent injury, do not use the power cord to transport or move the device. 6. To prevent injury, ensure the power cord is free from the castors during transport of the device.

Introduction 7 CAUTIONS 1. To prevent tipping, do not mount this unit more than 56 (142 cm) from the floor to the base of the pressure infusor unit. 2. This product is designed for pressure infusion only. 3. Do not sterilize the pressure infusor. 4. To reduce the risks associated with environmental contamination follow applicable regulations when disposing of this device or any of its electronic components. 5. Do not immerse the pressure infusor in cleaning or disinfecting solutions. The unit is not liquid proof. 6. Do not clean the pressure infusor with solvents. Damage to the case, label, and internal components may result. 7. Do not pinch the power cord of the pressure infusor when attaching other devices to the I.V. pole. NOTICES 1. Federal law (USA) restricts this device to sale by or on the order of a licensed healthcare professional. 2. The Ranger pressure infusor unit meets medical electronic interference requirements. If radio frequency interference with other equipment should occur, connect the unit to a different power source. 3. To reliably ground this Ranger pressure infusor unit, only connect to receptacles marked Hospital Only, Hospital Grade or a reliable grounded outlet. 4. To avoid Ranger pressure infusor damage: do not immerse the Ranger pressure infusor or pressure infusor parts or accessories in any liquid or subject them to any sterilization process. do not use solvents such as acetone or thinner to clean the pressure infusor; avoid abrasive cleaners. clean pressure infusor exterior with soft cloth using plain water or a mild, all-purpose or nonabrasive cleaner. 202041B

8 Introduction Product description The Ranger pressure infusor can be used with the Ranger blood/fluid warming unit, standard and high flow disposable sets, the Ranger irrigation warming unit, and irrigation warming sets 1. The infusor can accept solution bags ranging from 250 ml to 1000 ml. The pressure infusor delivers a maximum fluid pressure of 300 mmhg. Note: The solution pressure of the Ranger pressure infusor is dependent on surface area and volume of the solution bag. To verify the pressure, refer to the Maintenance Guide (part # 210393). The Ranger pressure infusor has no user-adjustable controls. The user slides an I.V. solution bag behind the metal fingers and against the inflation bladder located inside the pressure infusor. When the infusor is attached to an external power source and the main power switch is turned ON, pushing the pressure infusor power button ON inflates the inflation bladder and maintains pressure on blood and solution bags. Turning the pressure infusor power button OFF deflates the bladder. Turn the main power switch OFF when the pressure infusor is not in use. Main power switch Power entry module 1 Use a maximum of 1 liter solution bags when using the Ranger pressure infusor with the Ranger irrigation fluid warmer.

Introduction 9 Pressure infusor panel The pressure infusor panel displays the status of the pressure infusors. The pressure infusor power indicator illuminates amber (standby) when the main power switch is turned ON and the pressure infusors are able to be turned ON. A green LED indicates that the infusor is ON. To pressurize/depressurize the pressure infusor, verify the pressure infusor door is closed and latched, then press the pressure infusor power button. Each pressure infusor is controlled independently. Pressure Infusor Power no power to unit standby ON The indicator on the power button notifies the user of the status of each pressure infusor. No light indicates that the unit is either not plugged in, the main power switch is not turned ON, or there is a system fault. See Section 4: Troubleshooting on page 13 for more information. An amber indicator notifies the user that the pressure infusor is in standby mode and is ready to be turned ON. A green indicator notifies the user that the infusor is pressurized. 202041B

10 Introduction High Visual and audible alarm: The High amber indicator illuminates and an audible alarm notify the user when the pressure infusor bladder is above 330 mmhg. The visual indicator and alarm will continue as long as the pressure remains above 330 mmhg. If the High condition is observed, the infusor chamber should be turned OFF by using the pressure infusor power button. Use of the infusor chamber should be discontinued immediately, and 3M Health Care technical support contacted for repair and servicing. In Range Visual only: The In Range green indicator flashes as the pressure is increasing in the pressure infusor. Once the pressure is within the target range of 230-330 mmhg, the indicator will be at a consistent green. Low: Visual and audible alarm: The Low amber indicator illuminates and an audible alarm notify the user when the pressure infusor bladder has not reached 230 mmhg within approximately 30 seconds or when the pressure drops below 230 mmhg during use.

Instructions for Use 11 Section 3: Instructions for Use Attaching the pressure infusor to the I.V. pole 1. Mount the Model 145 pressure infusor onto a Model 90068/90124 pressure infusor I.V. pole/base as shown below. Caution: To prevent tipping, do not mount this unit more than 56" (142 cm) from the floor to the base of the pressure infusor unit. 2. Securely fasten the clamps at the back of the infusor and tighten the knob screws until the infusor is stable. 3. Using the provided hook-and-loop strap, secure the power cord to the lower portion of the I.V. pole. 202041B

12 Instructions for Use Load and pressurize the infusors 1. Plug the power cord into an appropriately grounded outlet. 2. Using the main power switch located under the pressure infusor, turn the unit ON. 3. Remove excess air from I.V. solution bags and prime. 4. Open pressure infusor door. 5. Slide solution bag to the bottom of the pressure infusor ensuring bag is completely inside the metal fingers. Note: Ensure solution bag port and spike hang below the pressure infusor fingers. 6. Securely close and latch the pressure infusor door. 7. Press the pressure infusor power button on the pressure infusor control panel to turn the corresponding pressure chamber ON. Note: A pressure infusor can only be turned ON when the power status display indicator is amber. A green display indicator notifies the infusor chamber is ON. 8. Once the pressure infusor is In Range, open clamps to begin flow. Changing a fluid bag 1. Press the pressure infusor button on the pressure infusor control panel to turn the corresponding pressure chamber OFF. 2. Close pinch clamps on tubing. 3. Open pressure infusor door and remove solution bag. 4. Remove the spike from the used solution bag. 5. Remove air from the new solution bag. 6. Insert spike into the new I.V. bag port. 7. Push the pressure infusor s bladder to expel the remaining air and slide solution bag to the bottom of the pressure infusor, ensuring bag is completely inside the metal fingers. Note: Ensure solution bag port and spike hang below the pressure infusor fingers. 8. Securely close and latch the pressure infusor door. 9. Press the pressure infusor power button on the pressure infusor control panel to turn the corresponding pressure chamber ON. Note: A pressure infusor can only be turned on when the power status display indicator is amber. A green display indicator notifies the infusor chamber is ON. 10. Once the pressure infusor is In Range, open clamps to resume flow from the new bag of fluid.

Troubleshooting 13 Section 4: Troubleshooting All repair, calibration, and servicing of the Ranger pressure infusor requires the skill of a qualified, medical equipment service technician who is familiar with good practice for medical unit repair. All repairs and maintenance should be in accordance with manufacturer s instructions. For additional technical support contact 3M patient warming. Standby/ON mode Condition Cause Solution Nothing illuminates on the pressure infusor control panel when the main power switch is turned ON. Power LED status lights do not illuminate. The status indicators (Low, In Range, and/or High) do not illuminate when the pressure infusor power button is pushed. Unit is not plugged into the power entry module, or power cord is not plugged into an appropriately grounded outlet. Unit failure. Unit is not plugged into the power entry module, or power cord is not plugged into an appropriately grounded outlet. Unit is not turned ON. Burned out LED light. Unit failure. Unit is not plugged into the power entry module, or power cord is not plugged into an appropriately grounded outlet. Unit is not turned ON. Burned out LED light(s). Unit failure. Make sure the power cord is plugged into the power entry module of the pressure infusor. Make sure the pressure infusor is plugged into a properly grounded outlet. Contact a biomedical technician. Make sure the power cord is plugged into the power entry module of the pressure infusor. Make sure the pressure infusor is plugged into a properly grounded outlet. Using the main power switch located under the pressure infusor turn the unit ON. Push the pressure infusor power button, if unit functions properly, continue use. Contact a biomedical technician after use to replace LED. Contact a biomedical technician. Make sure the power cord is plugged into the power entry module of the pressure infusor. Make sure the pressure infusor is plugged into a properly grounded outlet. Using the main power switch located under the pressure infusor turn the unit ON. Contact a biomedical technician. Contact a biomedical technician. 202041B

14 Troubleshooting Pressure infusor Condition Cause Solution Pressure infusor is not working. Low indicator (solid amber visual with audible alarm). High indicator (solid amber visual with audible alarm). Unit is not plugged into the power entry module, or power cord is not plugged into an appropriately grounded outlet. Unit is not turned ON. Unit fault. Pressure infusor bladder is loose or has become unattached. Pressure infusor door may not be closed and securely latched. Detected pressure has fallen below 230 mmhg. Pressure is above 330 mmhg. Make sure the power cord is plugged into the power entry module of the pressure infusor. Make sure the pressure infusor is plugged into a properly grounded outlet. Using the main power switch located under the pressure infusor turn the unit ON. Discontinue use of unit. Contact a biomedical technician. Reattach bladder by using your thumbs to fit one side of the bladder port on the bladder retaining collar and stretch into position. Securely close and latch the pressure infusor door. Continue infusion or use the other side of the pressure infusor. Contact a biomedical technician after use. Discontinue use of pressure infusor chamber. Use the other side of the pressure infusor. Contact a biomedical technician after use. Leakage of solution. Bag is not spiked securely. Secure spike in bag. Bladder does not deflate after pressure is discontinued. Unit fault. Contact a biomedical technician after use.

Maintenance and Storage 15 Section 5: Maintenance and Storage Cleaning the Ranger pressure infusor unit Clean the Ranger pressure infusor unit on an as-needed basis or per institutional protocol. To clean the outside of the unit 1. Disconnect the Ranger pressure infusor unit from the power source. 2. Wipe the outside of the unit with warm, soapy water, nonabrasive cleaning solutions, diluted bleach, or cold sterilants. Do not use abrasive materials. Contact 3M Patient Warming technical support for a complete list of approved cleaning solutions. 3. Wipe with a dry, soft cloth. Cautions Do not immerse the pressure infusor in cleaning or disinfecting solutions. The unit is not liquid proof. Do not clean the pressure infusor with solvents. Damage to the case, label, and internal components may result. Storage Cover and store all components in a cool, dry place when not in use. Take care not to drop or jar the unit. 202041B

16 Maintenance and Storage

Specifications 17 Section 6: Specifications Physical characteristics Dimensions 15.75 in (40 cm) high 20 in (51 cm) wide, 7.75 in (20 cm) deep Weight 17 lb. (7.7 kg) Mounting Dual clamp Classification Classifed under IEC 60601-1 Guidelines as Class 1, Type BF, Ordinary Equipment. Medical Equipment 24RL Classified by Underwriters Laboratories Inc. with respect to electric shock, fire, and mechanical hazards only, in accordance with UL 60601-1 and Canadian/CSA C22.2 No. 601.1. Storage/transport temperature -20 C to 45 C (-4 F to 113 F) Store all components in a cool, dry place when not in use. Electrical characteristics Leakage current Meets leakage current requirements in accordance with UL 60601-1 and IEC 60601-1. Power cord 15 feet (4.6 m) Device rating 110-120 VAC, 50/60 Hz, 1 Amp 220-240 VAC, 50/60 Hz, 0.8 Amp Fuse 1 Amps (110-120 VAC) 0.8 Amps (220-240 VAC) 202041B

18 Specifications Performance characteristics Operating pressure 300 mmhg setpoint Note: Pressure system is In Range when the pressure infusor bladders are inflated to between 230 mmhg (low) and 330 mmhg (high). If pressure falls below 230 mmhg for more than approximately 30 seconds the Low amber indicator will illuminate and an audible alarm will sound. The High amber indicator and an audible alarm notify the user when the pressure infusor bladder is above 330 mmhg. The outlet pressure of the fluid may vary with the surface area and volume of the solution bag.

Made in the USA of globally sourced material by 3M Health Care. 3M is a trademark of 3M Company, used under license in Canada. Ranger and the Bair Hugger logo are trademarks of Arizant Healthcare Inc., used under license in Canada. 2013 Arizant Healthcare Inc. All rights reserved. Federal law (USA) restricts this device to sale by or on the order of a licensed healthcare professional. 3M Deutschland GmbH, Health Care Business Carl-Schurz-Str. 1, 41453 Neuss, Germany 3M Health Care, 2510 Conway Ave., St. Paul, MN 55144 USA TEL 800-228-3957 www.rangerfluidwarming.com 202041B 07/13