ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact



Similar documents
ABB Power Systems. Substations References

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed

High-Voltage GIS yesterday - today - tomorrow

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Advantages of Fixed Circuit Breaker Switchgear

Chapter 1. Network Structures

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

How To Choose A Transformer

Environmental Product Declaration. Registration number: S-P Rev. 0 11/06/03. Tmax T1. Low voltage circuit breaker.

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

DS1 Diode-based transient-free capacitor switch

Safe and secure distribution of medium voltage with AX1

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Ralf Christian, CEO Low and Medium Voltage. Making Things Right with Totally Integrated Power (TIP)

Service Power Technologies. Retrofitting A future-oriented concept in lifecycle management

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Comparison of GIS and AIS systems for urban supply networks

The Intelligent AX1 Switchgear for Medium Voltage

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

Preliminary Results from Present Cigre Survey

Modular Systems wind portfolio overview Power Collection and Grid Connection products

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

PG&E Transmission Interconnection Handbook. Section L3: SUBSTATION DESIGN FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES

LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS

Medium Voltage Distribution FLUVAC. Vacuum Circuit Breaker Up to 24 kv 630 A 21 ka. Operation Maintenance Instructions.

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Remote Monitoring and REC 501 Control Unit Product Guide

Relion. Power system protection and automation reference Fast substation busbar protection with IEC and GOOSE

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

Disconnectors and Earthing Switches 36 kv up to 800 kv

IEC and IEEE Standards for High-Voltage Switchgear and Controlgear Present Situation and Future Evolution

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

Trip circuit supervision relay. Type RXTCS

Safety Manual BT50(T) Safety relay / Expansion relay

Brochure Introducing HVDC

Power products and systems. Intelligent solutions for power distribution Zone concept

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

What will MV switchgear look like in the future? by Jean-Marc Biasse

BU Control Technologies, Decathlon TM Product Overview. ABB in the Data Center Overview

Asset Management Plans

Permissible ambient temperature Operation Storage, transport

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Low Voltage Products. Switches Automatic Transfer Switches

7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units

INTELLIGENT SWITCHGEAR AND INFORMATION TECHNOLOGY

Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Comparison between Gas- and Air Insulated Network Concepts with the Life Cycle Cost Method

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

UFES Active protection for switchgear

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

RCP2 Portfolio Overview Document

CONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT services

FAQs-Main switchboard design criteria

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION

IEC in ZX Gas-insulated medium voltage switchgear

Substation Automation based on IEC 61850

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Siemens Fusesaver. Highest availability and cost savings for your MV distribution network.

Three-phase monitoring relay CM-PFE

TORKEL 820 Battery Load Unit

Type: DILM9 10(24VDC) Article No.:

DISCONNECTORS AND LOAD SWITCHES for railways

The complete range of consumer switchboards and switchgear

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work.

ABB Fuses Competitive Advantages

Metal Enclosed Switchgears Metal Clad Switchgears Gas Insulated RMU's

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM32 10(24V50HZ) Article No.:

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

Protection from Short-circuit

30 ms High Speed Transfer System (HSTS) Product Description

Secondary Unit Substations

Estimation of electrical losses in Network Rail Electrification Systems

Low voltage systems for all applications

HVDC 2000 a new generation of high-voltage DC converter stations

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D MOOSBURG TEL FAX

Medium voltage product. Instrument transformers for indoor applications Product overview

Welcome IEEE Members and Guests Jan 20, 2014

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

ADM1TE 5/30A DIN rail single phase two wire energy meter

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Transcription:

ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact

Authors Carl Ejnar Sölver, ABB High Voltage Products Rasmus Larsson, ABB High Voltage Products 2 ABB ABB s Disconnecting Circuit Breakers

Introduction Field experience and Life Cycle Studies over the last decade have proved ABB made Disconnecting Circuit Breakers (DCBs) to be a revolutionary concept for improving substation availability and reliability while significantly lowering environmental impact and substation footprint of high voltage switchgear. Contact system similar to that of a normal CB Introduction The DCB is based on the conventional live tank circuit breakers and fulfils the function of one circuit breaker and two disconnectors - without adding any internal moving parts that require maintenance and increase the risk of failure in the apparatus and power grid. Conventional air insulated outdoor high voltage substations are equipped with disconnectors, having current carrying contacts in open air. Disconnectors located on both sides of the circuit-breakers were originally introduced as a standard feature of substation design to facilitate rather frequent circuit-breaker maintenance and to isolate the circuit-breaker in case of its failure. However circuit-breaker technology has developed over the years, and now its maintenance needs are normally less frequent compared with outdoor air insulated disconnectors. Circuit-breaker de-energization due to recommended maintenance of modern circuit-breakers today is normally in the interval range of 12-20 years, enabling the outage to be planned to coincide with inspection and repair of the connected line, transformer etc. Fig 1. 145 kv DCB with integrated earthing switch. The disconnecting circuit breaker (DCB) was thus introduced as a response to the scenario that it may not be logical any more to use open air disconnectors to facilitate maintenance of circuit-breakers. In the DCB the disconnecting function is integrated, which minimizes the maintenance need. DCBs are presently available for rated voltages up to 550 kv. In a DCB, the normal interrupter contacts also provide the disconnecting function when in open position, see Fig. 1. A DCB has to fulfil both applicable CB standards and disconnector standards. A specific standard for disconnecting circuit breakers was issued by IEC in 2005. In the open position DCBs are locked in a fail proof way. The locking consists of electrical blocking of the operating mechanism, as well as mechanical locking of the linkage system to the main contacts. Thereafter the adjacent earthing switch is closed. The visible closed earthing switch verifies that the part of the system is de-energized and safe to work on, see Fig. 2. Fig 2. 145 kv DCB with built on current transformers and closed earthing switch ABB s Disconnecting Circuit Breakers ABB 3

Significant reduction in maintenance and failure outage Significant reduction in maintenance and failure outage DCBs give a higher reliability of the disconnecting function since the primary contacts are SF 6 enclosed and protected from pollution. The maintenance intervals are increased giving an overall increase of availability of the substation. To optimize availability of the power grid, different substation configurations such as single busbar, double busbar, breaker- and- a- half and double breaker solutions have been developed over the years. During the time when the breaker required the most maintenance, grid operators sometimes also implemented a transfer bus to enable the line to be energized during maintenance on the line circuit breaker. The DCB solution provides outage reduction in both maintenance and failure, compared to the conventional solutions. In the example from Figure 3 the maintenance outage and statistical failure outage is reduced by 76% by using the DCB solution compared to the conventional solution with transfer busbar and by 67% by using the conventional solution without transfer busbar. It was also found that a DCB singlebus solution performs better compared to a double bus solution with disconnectors. Due to the fact that the modern circuit breaker requires less maintenance than a disconnector, the transfer bus with its disconnector is no longer needed to increase the line availability it actually decreases the availability, see Fig. 3. Therefore to maximize the line availability the grid operators should eventually remove the transfer bus, and move over to the disconnecting circuit breaker solution. Solution Comparison 138 kv Load outages, minutes/year Maintenance LD1 (Conv + T) LD2 (Conv) LD3 (DCB) Failure 240.00 184.00 56.00 Maintenance and failure 12.03 10.48 7.71 Failure and failure 7.32E-3 5.71E-3 4.59E-3 Total outage 3.29E-4 2.67E-4 2.12E-4 Fig 3. Illustration and comparison of a conventional solution with and without a transfer busbar, and a DCB solution Conventional Double Busbar Load outages, minutes/year Incident sequences LD1 (MV Side) LD2 (Line) Maintenance 0.00 184.00 Failure 2.03 9.89 Total outage 2.03 193.89 Fig. 4 Conventional double bus solution with 3 incoming lines and two transformers and a bus coupler 4 ABB ABB s Disconnecting Circuit Breakers

Reducing environmental impact equivalent to removing an average of 5 cars In order to illustrate the environmental benefits of the DCB technology, a LCA study was made for a 145 kv, three-pole operated DCB, including the operating mechanism, earthing switch and support structure. The study took into consideration the environmental impact of the entire life cycle. It was based on the following assumptions: 40 year life span Electrical losses for 50% of rated normal current, i.e. 1575 A per phase. DCB Solution Load outages, minutes/year Incident sequences LD1 (MV Side) LD2 (Line) Maintenance 0.00 72.00 Failure 0.58 9.14 Total outage 0.58 81.14 Fig. 5 DCB solution with 3 incoming lines, two transformers and a bus coupler Several different environmental impact categories are considered in LCA studies, such as acidification, ozone depletion and global warming. In the present case, evaluation was made with regard to the global warming potential (GWP). This is generally the dominating impact category for products consuming energy during their lifetime. The result is expressed in kg CO 2 equivalents, and is shown in Figure 6. The impact from electric energy consumption is based on a mix of power generation systems relevant for the OECD countries, and considering the LCA perspective: 0.6265 kg CO 2 per kwh. Comparing the data in Figure 4 and Figure 5 it is found that the single busbar DCB solution performs better in terms of both maintenance and failure outages compared to the conventional double busbar solution. End of life Energy and material SF 6 Outage reduction with DCB solution from Figure 4 and 5: Line outage, maintenance: 60.8% Line outage, failure: 7.6% Medium voltage side outage, maintenance: 0% Medium voltage side outage, failure: 71.4% Use Manufacture -10000 10000 30000 50000 70000 90000 kg CO equivalents 2 Fig. 6 Global warming potential GWP of a 145 kv DCB, expressed in kg CO 2 equivalents. As shown in Figure 6, electric energy consumption during the usage phase contributes most to the global warming potential. Resistive losses in the main circuit are responsible for 70% of this energy consumption. The rest is shared by the thermostat controlled heater (10%) and the anti-condensation heater (20%) in the operating mechanism. It was assumed that the thermostat controlled heater was connected during half of the usage phase. ABB s Disconnecting Circuit Breakers ABB 5

Energy savings A major part of the environmental impact is related to the energy losses during the service life. Given below are results of actual field studies for CO 2 emission reduction Simplification of substations When used in a substation, the DCB replaces the conventional combination of circuit-breaker and separate disconnectors. Due to low maintenance requirements and high availability of the DCB it is also possible, in most cases, to simplify the substation configuration compared to a traditional substation. The overall result is considerable space savings up to 50%, and less equipment. There will also be fewer foundations and steel structures, and less control cables. During construction, there will be less civil work, fewer transports, etc. These simplifications reduce the overall environmental impact of the substation during manufacture and construction, and also during the service life. For small substations with DCBs the required space is reduced to an extent that it is quite feasible to make indoor solutions based on standard AIS equipment. The building architecture can be adapted to local preferences and surroundings, and the substation can easily be integrated into densely populated areas. Figure 8 shows as an example a 145 kv substation located in the northern part of Sweden. Fig 7. Conventional disconnector/circuit breaker/disconnector combination, replaced by a single DCB. Energy losses for the two alternatives of 145 kv equipment as shown in Figure 7 were calculated under the same assumptions as for the LCA study, i.e. 40 year operating time, 1575 A per phase, and 0.6265 kg CO 2 emitted per kwh. A realistic length and type of the connections between the two disconnectors and the circuit breaker was assumed: 8 m Falcon ACSR, diam. 39.3 mm. The power consumption of the heaters in the operating mechanisms was included. The study showed that the energy savings per bay with DCB during 40 years of service corresponds to almost 700 tons of CO 2, or around 17.5 tons per year. In a complete substation, with several bays, the value will be correspondingly higher. To put the values in perspective, it may be noted that an average car will emit around 3 tons of CO 2 per year that is by replacing one conventional CB + 2DC combination with a DCB CO 2 savings equivalent to removing 5 cars can be achieved. Figure 8. Example of 145 kv indoor substation with DCBs. The DCB technology is a recipient of the Swedish National Power Grid environmental price. 6 ABB ABB s Disconnecting Circuit Breakers

ABB s DCB portfolio The substation solution with DCB portfolio consists of single busbar, double busbar, ring bus, breaker- and- half solution and combinations between double/single breaker solutions in the voltage range 72.5kV up to 550kV - all with higher availability and reliability compared to conventional solutions. Type LTB 72,5 LTB 145 HPL 170-300 HPL 362-420 HPL 550 Rated voltage, kv 72.5 145 170-300 362-420 550 Rated current, A 3150 3150 4000 4000 4000 Circuit-breaking capacity, ka 40 40 50 50 63 Rated frequency, Hz 50/60 50/60 50/60 50/60 50 Field experience Back in the 1990 s it was discussed among Swedish utilities to combine traditional circuit breakers and disconnectors into single devices, eventually to be called disconnecting circuit breakers. ABB developed and tested the concept, and in year 2000 the first installation was made in Sweden for the 245 kv substation Untra, belonging to Svenska Kraftnät. Since then the technology has become firmly established as a standard solution in Sweden. It is now also quite extensively applied in more than 25 other countries. IEC has introduced a specific standard for the device, and today other major suppliers also have disconnecting circuit breakers in their product lines. ABB has installed and received orders for approximately 800 three phase DCB units. Recent significant DCB-orders awarded to ABB include: Storfinnforsen S/S (Sweden) 420 kv Hallsberg S/S (Sweden) 420 kv Rio Tinto S/S (Australia) 245 kv Hancheang S/S (China) 245 kv Rauma S/S (Finland) 420 kv ABB s Disconnecting Circuit Breakers ABB 7

Contact us For more information please contact: ABB AB High Voltage Products SE-771 80 Ludvika, Sweden Phone: +46 (0)240 78 20 00 Fax: +46 (0)240 78 36 50 E-mail: circuit.breaker@se.abb.com www.abb.com/highvoltage Copyright 2010 ABB All rights reserved NOTE! ABB AB is working continuously to improve the products. We therefore reserve the right to change designs, dimensions and data without prior notice. ABB s Disconnecting circuit breakers - Higher substation availability and lower environmental impact, 2010-09