Hydrophobic Interaction Chromatography Toyopearl Resins for HIC 65 series for most proteins Toyopearl Hexyl-65 Toyopearl Butyl-65 Toyopearl Phenyl-65 Toyopearl Ether-65 6 series for monoclonal antibodies Toyopearl Butyl-6 Toyopearl Phenyl-6 NEW! Toyopearl PPG-6 55 series for smaller proteins Toyopearl SuperButyl-55 TSK-GEL High-Performance Resins for HIC TSKgel Phenyl-5PW TSKgel Ether-5PW ToyoScreen Process Development Columns for HIC
Hydrophobic Interaction Chromatography Toyopearl resins for Hydrophobic Interaction Chromatography Hydrophobic interaction chromatography (HIC) is a powerful tool for the process purification of biomolecules. The technique utilizes the accessible hydrophobic regions located on protein surfaces and their interactions with a weakly hydrophobic stationary phase. HIC is an excellent complement to ion exchange and size exclusion chromatography particularly when protein isoforms exist or when feedstock impurities are of similar isoelectric point or molecular weight. The selectivity differences exploited by HIC can also be used after affinity separations in which closely related proteins with similar recognition sites are not distinguishable by the affinity ligand. How does HIC work? Proteins and other molecules with hydrophobic surfaces are attracted to the hydrophobic ligands of both reversed phase (RP) and HIC resins. RP resins have higher surface coverage and/or more hydrophobic ligand compared to HIC resins. Because of this, in a RP separation the target binding readily occurs in an aqueous solution, and desorption is promoted by the addition of an increasing amount of organic solvent. In HIC, proteins are bound to the resin by employing an aqueous high salt mobile phase. The salt conditions contribute to a lyotropic effect which allows the proteins to bind to the lower surface coverage of a hydrophobic ligand. Proteins are eluted by the simple technique of decreasing the salt concentration. Most therapeutic targets are eluted in a low salt or a no salt buffer. During elution the energy of interaction for a HIC step is less than that of a RP step. One means of gauging the relative binding energy between the two techniques is to measure the surface tension of the two sets of binding and elution conditions. Figure 1 provides a comparison of the surface tension generated by HIC and RP elution systems. Since HIC separates under milder eluting conditions, biological activity is typically retained. Five different hydrophobic surfaces and selectivities Tosoh Bioscience offers five HIC ligands featuring different degrees of hydrophobicity and selectivity. The hydrophobicity of Toyopearl HIC resins increases through the ligand series: Ether, PPG (polypropyleneglycol), Phenyl, Butyl, and Hexyl (Figure 2). Figure 1 The surface tension of aqueous solutions used in HIC and RPC Surface tension (erg/cm 2 ) Figure 2 8 6 4 2 (NH 4 ) 2 SO 4 Concentration (mol/l) 1 2 3 4 2 4 6 8 1 % Acetonitrile HIC RPC Mode Gradient (typical) Δ Surface tension (erg/cm 2 ) HIC 1.8 to mol/l 4 (NH 4 ) 2 SO 4 / aqueous buffer RPC 1 to 5% ACN/.1%TFA 23 Hydrophilic Desorb protein C. Horvath et. al., Separation Processes in Biotechnology, (J. Asenjo, Ed.) 9, 447 (199) Marcel Dekker Ether Bind protein CH 3 CN Bind protein Available HIC ligands (OCH 2 CH 2 ) n OH PPG O Phenyl OH n O Butyl (NH 4 ) 2 SO 4 Desorb protein OCH 2 CH 2 CH 2 CH 3 Hexyl Hydrophobic OCH 2 CH 2 CH 2 CH 2 CH 2 CH 3 Features hydrophilic polymer resin matrix good mechanical stability Benefits robust chemical stability between ph 1-13 temperature range 4-6 C autoclavable at 121 C compatible with organic solvents constant bed volume over a wide range of salt concentrations low non specific protein binding superior protein recovery excellent flow characteristics in large industrial size columns direct scale-up from TSK-GEL HIC HPLC columns 28 www.toyopearl.com
Coordinating the hydrophobicity of the therapeutic target to the resin hydrophobicity is critical for the best overall purification performance. Too hydrophobic a resin for a given protein can result in its irreversible binding to the resin or a loss of enzymatic activity. Table I and II show typical mass recovery and biological activity recovery data for Toyopearl HIC resins. An optimum HIC process step will balance high dynamic binding capacity, adequate selectivity, good mass recovery and retention of biological activity. The wide range of Toyopearl selectivities enables a developer to optimize protein separations at the extremes of the hydrophobic spectrum. Highly retentive Toyopearl Hexyl-type and Toyopearl Butyl-type resins are used to separate hydrophilic proteins. These two resins should also be considered for separations requiring a low salt environment. Toyopearl Ether-type resin is used for the purification of very hydrophobic targets such as certain monoclonal antibodies and membrane proteins. These proteins may bind irreversably to other more hydrophobic resins. Toyopearl PPG-type and Toyopearl Phenyl-type phases complement the other HIC ligands available in the Toyopearl series and offer alternatives Table I High mass recovery (%) of proteins Toyopearl HIC resin Ether Phenyl Butyl -65M -65M -65M Bovine serum albumin 84 62 76* α-chymotrypsinogen 96 88* 9 Cytochrome C 81* 87* IgG 91 α-lactalbumin 9 Lysozyme 94 92 85 Ovalbumin 83 88 73 Ribonuclease A 72* 82* Procedure: A 2 ml sample containing 2 mg of protein was loaded onto a 7.5 mm ID x 7.5 cm L column and eluted with a 6 minute gradient of 1.8 mol/l (*1.5 mol/l) to. mol/l ammonium sulfate in.1 mol/l sodium phosphate (ph 7.). The mass recovery was determined spectrophotometrically at UV 28 nm and 25 C. Table II Recovery of enzymatic activity of proteins Toyopearl Protein % Activity HIC resin recovery Phenyl-65 Phytochrome 79 Butyl-65 Halophilic protease 85 Butyl-65 Poly (3-hydroxybutyrate) depolymerase 88 Butyl-65 Aculeacin-A acylase 82 Butyl-65 Opine dehydrogenase 81 for mid-range hydrophobic Toyopearl proteins. ToyoScreen prepacked columns for process development ToyoScreen columns packed with the full range of our Toyopearl HIC products are available in 1 ml and 5 ml resin volumes. They provide a convenient way to screen different resins for both target retention and recovery. Multiple columns can be connected in series for additional separation. Please see the ordering information at the end of this section or contact us for more information on these products. The retention and selectivity of protein standards on Toyopearl HIC resins using the ToyoScreen process development columns are shown in Figure 3. Influence of salt type In addition to the hydrophobicity of the ligand, the selectivity in HIC is influenced by the eluent salt type. Figure 4 demonstrates the effect of salt type on the resolution factor of different protein pairs. Figure 3 UV @ 28nm (mau) Screening of Toyopearl HIC resins - Standard Proteins 3 25 2 25 1 5 Ether-65M PPG-6M Phenyl-65M Butyl-65M SuperButyl-55C Hexyl-65C 1 2 3 4 5 Elution time (min) Column: ToyoScreen (1 ml) Eluent A:.1 mol/l Phosphate buffer +1.8 mol/l Sodium sulfate (ph 7.) Eluent B:.1 mol/l Phosphate buffer (ph 7.) Gradient: 3 min linear gradient from A to B Flow rate: 1 ml/min Inj. vol.: 5 µl Samples: Ribonuclease A, Lysozyme, α-chymotrypsinogen, 1 mg/ml Figure 4 Resolution factor (Rs) Influence of salt-type on resolution 1 5 Na 3 Citrate Cytochrome c/conalbumin Na 2 SO 4 (NH 4 ) 2 SO 4 NaCl NH 4 SCN Conalbumin/β-Glucosidase Chromatography on a Butyl-substituted support Column dimensions: 4.1 mm ID x 4 cm L Elution: Linear gradient, 2 min., 1. mol/l to mol/l of indicated salt in 2 mmol/l phosphate buffer (ph 7.). Flow rate, 1 ml/min. J. Fausnaugh, L. Kennedy and F. Regnier, J. Chromatography 317, 141 (1984) Na 3 Citrate Na 2 SO 4 (NH 4 ) 2 SO 4 NaCl NH 4 SCN For ordering information, see pages 34-36. 29
Hydrophobic Interaction Chromatography The Hofmeister lyotropic salt series shown in Figure 5 ranks anions and cations by their ability to promote protein precipitation. Ions on the left are referred to as lyotropic while the ions on the right are called chaotropic. Lyotropic salts will precipitate or salt out proteins at high salt concentrations due to increased hydrophobic interaction, while chaotropic salts will promote protein denaturation at high salt concentrations. Figure 5 indicates that different salt systems may generate a variety of adsorption and desorption selectivities for each resin. This feature of HIC provides an additional parameter for the optimization of a process step. Figure 5 Hofmeister lyotropic salt series For 2-2- SO 4 > HPO 4 > CH 3 COO - anions > halide > NO 3 - > CIO 4 - > SCN - Figure 7 For cations (CH 3 ) 4 N + > NH 4 + > K + > Na + > Cs + > Li + > Mg 2+ > Ca 2+ > Ba 2+ Ammonium sulfate and sodium sulfate are the most commonly used salts in HIC. NaCl is often used as well. Particle size optimization Toyopearl and TSK-GEL PW-type methacrylic base beads incorporate the same polymer chemistry (see Figure 6 or refer to the Size Exclusion section for a more detailed discussion) and are available in a variety of particle sizes: 1 µm Toyopearl C-grade Capture 65 µm Toyopearl M-grade Intermediate Purification 35 µm Toyopearl S-grade Intermediate Purification/Polishing 3 and 2 µm TSK-GEL PW-type High Resolution In many cases analytical columns are available packed with 1 µm particles having the same selectivity as the process media. Figure 7 shows the variety of ligands and particle sizes available for HIC process-scale applications. This figure also depicts where each particle size is used in a chromatographic manufacturing train (i.e. for capture, intermediate purification, or polishing). Figure 6 Methacrylic base beads available for HIC Pore size (Å) 5 125 4-5 75 1 >1 >17 Product name Toyopearl HW-type: 4 5 55 6 65 75 8 TSK-GEL PW-type: G1 G2 G4 G5 G6 Increasing pore surface area Process step Feedstock Bead size Process media Capture 1 µm Toyopearl SuperButyl-55C Toyopearl Hexyl-65C Toyopearl Butyl-65C Toyopearl Phenyl-65C 65 µm Toyopearl Butyl-6M Toyopearl Phenyl-6M Toyopearl PPG-6M Intermediate Purification Toyopearl Butyl-65M Toyopearl Phenyl-65M Toyopearl Ether-65M 35 µm Toyopearl Butyl-65S Toyopearl Phenyl-65S Toyopearl Ether-65S 3 µm TSKgel Phenyl-5PW (3) TSKgel Ether-5PW (3) Polishing 2 µm TSKgel Phenyl-5PW (2) TSKgel Ether-5PW (2) QC Same selectivity HPLC columns are available for most process media Pure Product 1 µm TSKgel Phenyl-5PW 2 mm ID x 7.5 cm L TSKgel Ether-5PW 2 mm ID x 7.5 cm L 3 www.toyopearl.com
Mechanical stability The semi-rigid polymeric backbone of Toyopearl and TSK-GEL HIC resins permits high flow rates for maximum throughput and productivity. Toyopearl resins may be operated up to 3 bar and TSK- GEL PW-type resins may be operated up to 2 bar. The pressure-flow characteristics for each particle size grade of Toyopearl Phenyl-65 resins are shown in Figure 8. The beads are compatible with both fixed bed and dynamic axial compression columns. Chemical stability The polymeric structure of these products also makes them resistant to a wide range of ph conditions and ionic strengths. In addition, the hydroxylated surface of the base bead reduces non-specific binding of proteins. Pore size optimization Most Toyopearl HIC products are derived from the versatile size exclusion resin, Toyopearl HW-65 (1, Å mean pore size), as the base bead for the majority of protein separations. But the pore size and accessible surface area of Toyopearl can be optimized for a given protein. More accessible surface area increases the dynamic binding capacity (DBC) of the bead for a particular therapeutic target. This has led to the development of two specialty lines of HIC materials with higher dynamic binding capacities. High dynamic binding capacity Toyopearl process resins For monoclonal antibodies a pore size of 75 Å is optimum. A specially made base resin, Toyopearl HW-6, has this pore size. Three ligands are available on Toyopearl HW-6: Toyopearl PPG-6M, Toyopearl Phenyl- 6M and Toyopearl Butyl-6M. A comparison of their DBCs with Toyopearl Phenyl-65M is shown in Figure 9. The selectivities of Toyopearl Butyl-6M, Toyopearl PPG-6M and the new Toyopearl Phenyl-6M are shown in Figure 1. Figure 8 Figure 9 Breakthrough curves of polyclonal IgG on various HIC resins.15 C/C.1.5 Phenyl-65M Butyl-6M Agarose type Phenyl 1 2 3 4 5 IgG loaded (g/l-resin) Phenyl-6M Column: 7.8 mm ID X 2 cm L Sample: polyclonal human IgG Binding buffer: 1 g/l IgG in.8 mol/l (NH 4 ) 2 SO 4 +.1 mol/l sodium phosphate (ph 7.) Linear velocity: 3 cm/hr Temperature: 25 C DBC was calculated at 1% of breakthrough. Figure 11 compares the selectivities of the new Toyopearl Phenyl-6M, Toyopearl Phenyl-65M and an agarose Phenyl resin. For smaller molecules such as lysozyme (12, Da) the even narrower pore diameter Toyopearl SuperButyl-55C (derived from the 5 Å pore diameter Toyopearl HW-55) is recommended. A comparison of the DBC of Toyopearl SuperButyl-55C with other Toyopearl HIC resins is shown in Figure 12. Figure 1 Comparison of Toyopearl 6M series resins Toyopearl PPG-6M 2 3 Pressure-flow curve for Toyopearl Phenyl-65 resins of various particle size Phenyl-65S 3 Phenyl-65M UV @ 28 nm (mau) 15 1 5 Toyopearl Phenyl-6M Toyopearl Butyl-6M 1 Pressure (bar) 2.5 2 1.5 Phenyl-65C 2 4 6 8 Flow (cm/h) Column: Eluent: Toyopearl Phenyl-65C, M and S, 25 mm ID x 25 cm L 2 mol/l (NH 4 ) 2 SO 4 1 2 3 4 5 6 7 Elution volume (ml) Column: 7.5 cm ID X 7.5 cm L Sample: 1 g/l RNase A (1), lysozyme (2) and a-chymotrypsinogen A (3) Sample load: 1 µl Gradient: 6 min linear gradient from buffer A to B Buffer A: 1.8 mol/l (NH 4 ) 2 SO 4 +.1 mol/l sodium phosphate (ph 7.) Buffer B:.1 mol/l sodium phosphate (ph 7.) Linear velocity: 136 cm/hr Temperature: 25 C For ordering information, see pages 34-36. 31
Hydrophobic Interaction Chromatography Figure 11 Selectivity comparison of phenyl-type resins 2 Figure 13 Toyopearl Phenyl-6M Breakthrough curve (lysozyme).15 15 Toyopearl Phenyl-6M 1 3 Phenyl-65M Phenyl-6M UV @ 28 nm (mau) 1 5 Toyopearl Phenyl-65M Agarose type Phenyl C/C.1.5 Figure 12 Typical dynamic binding capacities for Lysozyme Absorbance UV @ 28 nm Column: 7.5 cm ID X 7.5 cm L Sample: 1 g/l RNase A (1), lysozyme (2) and α-chymotrypsinogen A (3) Sample load: 1 µl Gradient: 6 min. linear gradient from buffer A to B Buffer A: 1.8 mol/l (NH 4 ) 2 SO 4 +.1 mol/l sodium phosphate (ph 7.) Buffer B:.1 mol/l sodium phosphate (ph 7.) Linear velocity: 136 cm/hr Temperature: 25 C.3.2.1 Ether-65M 1 2 3 4 5 6 7 Elution volume (ml) Phenyl-65M Butyl-65M Hexyl-65C 2 4 6 8 Lysozyme loaded (mg/ml-resin) Binding capacity (mg/ml - gel) (1% Breakthrough) Ether-65M 12.5 Phenyl-65M 27.5 Butyl-65M 32.2 Hexyl-65C 33.2 PPG-6M 44.2 SuperButyl-55C 54.3 PPG-6M SuperButyl-55C Conditions Column size: 7.8 mm ID x 2 cm L Sample: 1 mg/ml Lysozyme in.1 mol/l Phosphate buffer + 1.8 mol/l Sodium Sulfate (ph 7.) Linear velocity: 1 cm/h Detection: UV @ 28 nm 2 4 6 8 Lysozyme loaded (mg/ml-resin) Binding capacity (mg/ml - gel) (1% Breakthrough) Phenyl-6M 58 Phenyl-65M 27 Column: 7.8 mm ID x 2 cm L Sample: 1 mg/ml lysozyme in.1 mol/l phosphate buffer (ph 7.) + 1.8 mol/l (NH 4 ) 2 SO 4 Linear velocity: 3 cm/hr The new Toyopearl Phenyl-6M also has a high DBC for lysozyme. (Figure 13). The engineered higher dynamic binding capacity of the 6 and 55 series HIC products for their specific targets and the selectivity differences induced by the smaller mean pore size of the respective beads, can have a dramatic impact on process economics. Improving target feedstock concentration and purity for downstream steps can greatly enhance throughput and reduce process costs. Monoclonal antibodies Hydrophobic interaction is a very useful technique for the purification of monoclonal antibodies. The diverse hydrophobic nature of mabs is seen in Figure 14. This figure measures the hydrophobicity (using elution time as a surrogate measurement) of 51 different mouse IgGs on a TSK-GEL Phenyl-5PW analytical column. Some of the IgGs have elution times 2-3 times longer than others indicating greater hydrophobicity. The Toyopearl series of HIC ligands (Figure 2) with their different hydrophobicities gives chromatographic developers a range of options for finding the right ligand for their target molecule. For a very hydrophobic mab, such as mouse anti-chicken 14 kda lectin, the less hydrophobic Toyopearl Ether ligand works quite well. The Breakthrough curve (lysozyme) purification from ascites fluid (Figure 15) was performed with a 1 µm TSKgel Ether-5PW semi-preparative column. Identical selectivity for scale-up was found with corresponding 65 µm Toyopearl Ether-65M. 32 www.toyopearl.com
Figure 14 Hydrophobic diversity of mouse monoclonals Plot of chromatographic elution times for 51 different mouse mabs Elution time of each antibody on TSKgel Phenyl-5PW(min) 9 8 7 6 5 4 3 2 1 Column: Eluent : No.1 No.3 No.5 No.7 No.9 No.11 No.13 No.15 No.17 No.19 No.21 No.23 No.25 No.27 No.29 No.31 No.33 No.35 No.37 No.39 No.41 No.43 No.45 No.47 No.49 No.51 Antibody TSK-GEL Phenyl-5PW (A).1 mol/l phosphate buffer containing 1.8 mol/l ammonium sulfate (ph 7.) (B).1 mol/l phosphate buffer (ph 7.) Flow rate : 1 ml/min Gradient : (B) % ( min)--% (5 min)--1% (65 min) linear Samples : 51 kinds of mouse monoclonal antibodies Figure 15 Purification of mabs from ascites fluid A. 1 µm TSKgel Ether-5PW 15 3 Minutes B. 65 µ m Toyopearl Ether-65M mab mab Protein aggregate removal The larger pore Toyopearl products such as Butyl-65 and Phenyl-65 are very useful for protein aggregate separation and removal. Early work by Karger et al 1 in 1989 involving proteins and aggregates larger than 2 kda demonstrated the effectiveness of HIC for this application. Glycoproteins Toyopearl HIC resins can purify glycoproteins, which often bind irreversibly to saccharide-based chromatographic media. Figure 16 shows the purification of a large glycoprotein on Toyopearl Butyl-65S resin. DNA plasmid purification and endotoxin removal Toyopearl Hexyl-65C resin was successfully used for plasmid DNA purification by Cambrex, Baltimore, MD (US patent 6,953,686). Hexyl- 65C was shown to be the most effective among HIC resins for endotoxin removal with capacities exceeding 2 million EU/mL of resin. Additionally, RNA and protein impurities were effectively eliminated. Hexyl-65C was also effective in separating the supercoiled and open circular forms of plasmid DNA. Removal of misfolded proteins Because misfolded proteins will generally be more hydrophobic than the native protein, Toyopearl Butyl-65M resin is used frequently for the removal of misfolded proteins. In many cases flow through chromatography can be accomplished under eluent conditions binding the misfolds while allowing the target to flow through the column. Please check the database on our website, www.tosohbioscience.de, for additional applications. 1 Grinberg, N. Blanco, R. Yarmush, D. Karger, B. L. Protein Aggregation in High Performance Liquid Chromatography: Hydrophobic Interaction Chromatography of β-lactoglobin, Anal. Chem. 1989, 61, 514-52 Column: Sample: Elution: 15 3 Minutes Linear velocity: Detection: Figure 16 A. TSKgel Ether-5PW, 7.5 mm ID x 7.5 cm L B. Toyopearl Ether-65M, 7.5 mm ID x 7.5 cm L anti-chicken 14 kda lectin, diluted ascites fluid, A. 1.5 mg in 1 µl; B..76 mg in 5 µl 6 min linear gradient from 1.5 mol/l to mol/l (NH 4 ) 2 SO 4 in.1 mol/l phosphate buffer (ph 7.) 136 cm/h UV @ 28 nm Large glycoprotein purified on Toyopearl Butyl-65S Absorbance, 28nm 2. 1. Column: Sample: Elution: A. B. C. 1 2 3 4 5 6 7 8 9 1 Fraction number (8 ml/fraction) Antibacterial activity (%-Inhibition) Toyopearl Butyl-65S, 22 mm ID x 26 cm L crude protein from sea hare Aplysia kurodai multi-step (NH 4 ) 2 SO 4 in 5 mmol/l phosphate buffer (ph 7.) A. load & wash: 4% saturated (NH 4 ) 2 SO 4 B. 2% saturated (NH 4 ) 2 SO 4 C. % saturated (NH 4 ) 2 SO 4 1 5 For ordering information, see pages 34-36. 33
Hydrophobic Interaction Chromatography Ordering Information ToyoScreen process development columns for HIC Part # Product description Package 21372 ToyoScreen Ether-65M 1 ml x 6 each 21373 ToyoScreen Ether-65M 5 ml x 6 each 21374 ToyoScreen Phenyl-65M 1 ml x 6 each 21375 ToyoScreen Phenyl-65M 5 ml x 6 each 21376 ToyoScreen Butyl-65M 1 ml x 6 each 21377 ToyoScreen Butyl-65M 5 ml x 6 each 21378 ToyoScreen Hexyl-65C 1 ml x 6 each 21379 ToyoScreen Hexyl-65C 5 ml x 6 each 2138 ToyoScreen PPG-6M 1 ml x 6 each 21381 ToyoScreen PPG-6M 5 ml x 6 each 2138 ToyoScreen Butyl-6M 1 ml x 6 each 21381 ToyoScreen Butyl-6M 5 ml x 6 each 21494 ToyoScreen Phenyl-6M 1 ml x 6 each 21495 ToyoScreen Phenyl-6M 5 ml x 6 each 21382 ToyoScreen SuperButyl-55C 1 ml x 6 each 21383 ToyoScreen SuperButyl-55C 5 ml x 6 each 21398 ToyoScreen HIC Mix Pack 1 ml x 6 Grades x 1 each 21399 ToyoScreen HIC Mix Pack 5 ml x 6 Grades x 1 each ToyoScreen column accessories Part # Product description Comment 214 ToyoScreen Column Holder TSK-GEL LabPak Part # Product description Container size (ml) Particle size (µm) 43278 HICPAK PW (2) (Ether-5PW, Phenyl-5PW) 2 x 25 ml 1-3 43175 HICPAK PW (3) (Ether-5PW, Phenyl-5PW) 2 x 25 ml 2-4 34 TOSOH BIOSCIENCE www.toyopearl.com
Toyopearl HIC resins Part # Product description Container size (ml) Particle size (µm) Typical capacity (mg lysozyme/ml resin) 43151 Toyopearl Ether-65S 25 2-5 1-3 16172 1 16174 1, 16176 5, 1985 Toyopearl Ether-65M 25 4-9 1-3 16173 1 16175 1, 16177 5, 2131 Toyopearl PPG-6M 25 4-9 45-55 2132 1 2133 1, 2134 5, 2135 5, 21887 Toyopearl Phenyl-6M 25 4-9 45-65 21888 1 21889 1, 2189 5, 2891 5, 43152 Toyopearl Phenyl-65S 25 2-5 3-5 14477 1 14784 1, 14935 5, 19818 Toyopearl Phenyl-65M 25 4-9 3-5 14478 1 14783 1, 14943 5, 18364 5, 43126 Toyopearl Phenyl-65C 25 5-15 3-5 14479 1 14785 1, 14944 5, 43153 Toyopearl Butyl-65S 25 2-5 3-5 7476 1 1471 1, 7975 5, 18826 5, 1982 Toyopearl Butyl-65M 25 4-9 3-5 7477 1 1472 1, 7976 5, 18355 5, 43127 Toyopearl Butyl-65C 25 5-15 3-5 7478 1 1473 1, 7977 5, 21448 Toyopearl Butyl-6M 25 4-9 - 21449 1 2145 1, 21451 5, 21452 5, 19955 Toyopearl SuperButyl-55C 25 5-15 52-7 19956 1 19957 1, 19958 5, 19959 5, 44465 Toyopearl Hexyl-65C 25 5-15 3-5 1926 1 1927 1, 1928 5, For ordering information, see pages 34-36. 35
Hydrophobic Interaction Chromatography Part # Product description Container size (ml) Particle size (µm) Adsorption capacity (mg lysozyme/ml resin TSK-GEL 5PW HIC resins for high resolution 43276 TSKgel Ether-5PW (2) 25 1-3 1-3 1652 25 1653 1, 18437 5, 43176 TSKgel Ether-5PW (3) 25 2-4 1-3 165 25 1651 1, 18439 5, 43277 TSKgel Phenyl-5PW (2) 25 1-3 1-3 14718 25 14719 1, 18438 5, 43177 TSKgel Phenyl-5PW (3) 25 2-4 1-3 1472 25 14721 1 1721 5, 36 www.toyopearl.com
For further information please contact: Hichrom Limited 1 The Markham Centre, Station Road, Theale Reading, Berkshire, RG7 4PE Tel: 118 93 366 Fax: 118 932 3484 Email: technical@hichrom.co.uk www.hichrom.co.uk