NAJAFGARH DRAIN-SAMPLING AND ANALYSIS

Similar documents
State of pollution in the Yamuna

[Dubey*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

Review of the interceptor plan for the Yamuna Analysis by

Bacteriological water quality status of River Yamuna in Delhi

WASTEWATER TREATMENT

Water quality of River Yamuna Delhi stretch

Chapter 2 Brief Overview of the Yamuna River Basin and Issues

Water and Wastewater. Sample Collection and Analysis

WATER QUALITY STATUS OF RIVER YAMUNA IN DELHI WITH REFERENCE TO PRESENCE OF HEAVY METALS: A REVIEW

PRSENTATION ON DRAINAGE SYSTEM DELHI EAST DELHI MUNICIPAL CORPORATION

WASTEWATER TREATMENT OBJECTIVES

City of Lakeland s Wetlands Treatment System An Overview

Environmental Science 101 Waste. Fall Lecture Outline: Terms You Should Know: Learning Objectives: Reading Assignment: Chlorinated.

Maine Department of Environmental Protection Program Guidance On Combined Sewer Overflow Facility Plans

Assessment of Surface Water Quality Using Qual2k Software: A Case Study of River Yamuna, India

Planning, Designing, Monitoring and Inspection of Wastewater Treatment Systems of Industries

Water Quality Monitoring in India: A Review

Sewerage Management System for Reduction of River Pollution

International Journal of Innovative Research in Science, Engineering and Technology Vol. 2, Issue 5, May 2013

Treatment of dairy wastewater by natural coagulants

TREATMENT OF SANITARY SEWER OVERFLOW

Environmental Engineering, University of Seoul, Jennong-dong, Dongdaemun-gu, Seoul, Korea.

QUANTITATIVE ASSESSMENT OF PHYSICOCHEMICAL CONSTITUENTS AS FLUORIDE, IRON AND NITRATE CONTAMINATED DRINKING GROUNDWATER

Table 1.1: Typical Characteristics of Anaerobically Digested Wastewater

NANYANG TECHNOLOGICAL UNIVERSITY. School of Civil and Environmental Engineering. CV2701: Laboratory 2A. Laboratory Manual. For

SAMPLE CHAPTERS UNESCO EOLSS SURFACE WATER MONITORING. Masanori Ando Musashino University, Japan

Sewage Discharge in Estuaries: The case for Trapping.

Analysis of Total Suspended Solids and Dissolved Oxygen Concentrations of the Algal- Bacterial Selenium Removal (ABSR) system.

A Clean Harbour for Hong Kong. Government s Initial Response To The Report of the International Review Panel On Sewage Treatment for the Harbour Area

GUIDELINES FOR LEACHATE CONTROL

AP ENVIRONMENTAL SCIENCE 2007 SCORING GUIDELINES

NPDES Permit No. IL Notice No. AAH: ajo. Public Notice Beginning Date: April 28, Public Notice Ending Date: May 30, 2011

Module 7: Hydraulic Design of Sewers and Storm Water Drains. Lecture 7 : Hydraulic Design of Sewers and Storm Water Drains

NPDES Permit No. IL Notice No. SKT: bah. Public Notice Beginning Date: April 9, Public Notice Ending Date: May 9, 2014

Facility Classification Standards

Who is responsible for making sure that wastewater is treated properly?

Lakes and Ponds: Pollution Abatement and Environmental Sustainability

BY-LAW CONCERNING DISCHARGES AT PURIFICATION WORKS ON THE TERRITORY OF THE URBAN AGGLOMERATION OF MONTRÉAL

Glossary of Wastewater Terms

Current condition of the Yamuna River - an overview of flow, pollution load and human use

Evaluation of Alternatives to Domestic Ion Exchange Water Softeners. Mara Wiest Dr. Peter Fox Dr. Lee Wontae, HDR Tim Thomure, HDR

DATA COLLECTION FOR DESIGN OF WASTEWATER TREATMENT FACILITIES

Ground Water Contamination by Leachate

Department of Environmental Engineering

Phosphorus Removal. Wastewater Treatment

Prof. Shyam R. Asolekar Centre for Environmental Science and Engineering Indian Institute of Technology Bombay Powai, Mumbai

Environmental Regulations & Best Management Practices CARPET CLEANING OPERATIONS. Carpet Cleaning Operations in the Capital Regional District

Cambridge Wastewater Treatment Facility

INFORMATION SHEET ORDER NO. R XXXX TRIANGLE ROCK PRODUCTS, INC. FLORIN ROAD AGGREGATE PLANT SACRAMENTO COUNTY


Creating the environment for business

WATER QUALITY PARAMETERS OF RIVER YAMUNA IN DELHI AFTER 20 YEARS OF THE YAMUNA ACTION PLAN

WATER QUALITY MONITORING AND APPLICATION OF HYDROLOGICAL MODELING TOOLS AT A WASTEWATER IRRIGATION SITE IN NAM DINH, VIETNAM

DRAINAGE DISCHARGE AGREEMENTS A WAY OF MANAGING RISK Mr. Sam Green Goulburn-Murray Water

COD/BOD 5 Reduction with ROTAMAT Fine and Micro Screens

How to measure Ammonia and Organic Nitrogen: Kjeldahl Method

How To Monitor Toxicity In Water

Comparing Levels of Phosphates in Dishwasher Detergents

Hydrological and Material Cycle Simulation in Lake Biwa Basin Coupling Models about Land, Lake Flow, and Lake Ecosystem

Practice Tests Answer Keys

ACCELERALTED PHOSPHATE & NITRATE LEVEL: FACTORS TO BLAME FOR EUTROPHICATION IN YAMUNA RIVER, DELHI, INDIA

Total Suspended Solids Total Dissolved Solids Hardness

ECONOMIC ANALYSIS OF WATER USES GESTÃO INTEGRADA DE BACIAS HIDROGRÁFICAS INSTITUTO SUPERIOR TÉCNICO

St. John s Harbour Clean-Up Phase 2. Project Description

Georgia Department of Public Health. Georgia Onsite Sewage Management Systems. Background and Use of Onsite Wastewater Treatment Systems in Georgia

Institutional intervention in River Water Management: the Study of Yamuna river sub-basin in India 1

Alberta Environment Standards for Advanced Waste Systems

Hydro Chemical Analysis of Surface and Ground Water Quality of Yamuna River at Agra, India

Development of Advanced Wastewater Treatment and Reclamation System

DOMESTIC WASTEWATER SYSTEMS

Guidance for assessment of representativeness and reliability of baseline environmental attributes

Research Article APPLICATION OF QUAL2K FOR ASSESSING WASTE LOADING SENARIO IN RIVER YAMUNA Vasudevan M a *, Nambi, I. M b, Suresh Kumar, G c

National Water Quality Monitoring Programme

A NOVEL ION-EXCHANGE/ELECTROCHEMICAL TECHNOLOGY FOR THE TREATMENT OF AMMONIA IN WASTEWATER

OPTIMIZING BIOLOGICAL PHOSPHORUS REMOVAL FROM AN SBR SYSTEM MIDDLEBURY, VT. Paul Klebs, Senior Applications Engineer Aqua-Aerobic Systems, Inc.

Guidance on applying for approval of installation of a commercial onsite wastewater system

City of Charlottetown Wastewater Treatment Expansion & Upgrading

Advanced Wastewater Treatment Process

Presented by Paul Krauth Utah DEQ. Salt Lake Countywide Watershed Symposium October 28-29, 2008

Water Treatment Filtration Lab. discharged into an aquatic ecosystem? We had to build a water filtration system with

Toxic Municipal Waste Water Treatment

Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service

COMPANY PROFILE & CAPABILITY STATEMENT

1.3 Wastewater and Ambient Water Quality

FACT SHEET STATEMENT OF BASIS HARLEY DOME 1 PRODUCED WATER TREATMENT FACILITY UPDES PERMIT NUMBER: UT NEW PERMIT MINOR INDUSTRIAL

NPDES Permit No. IL Notice No. JCH: bah. Public Notice Beginning Date: November 27, Public Notice Ending Date: December 27, 2012

Pursuant to Department of Environmental Protection Rules Chapter 555, effective March 9, 2009

In-Situ carrying. Drains. Delhi

4 Water supply description

Type of Sewer Systems. Solomon Seyoum

ENGINEERING REPORT Sewage Treatment System

MEMBRANE TECHNOLOGY TREATING OILY WASTEWATER FOR REUSE

Control Technology, Advanced Treatment Processes, and Next-generation Systems for Sewage and Wastewater

TERMS OF REFERENCE FOR THE RAPID EIA STUDY

Transcription:

Dr. Anamika Paul* Preeti Jain* Kartikey Handa* NAJAFGARH DRAIN-SAMPLING AND ANALYSIS Abstract: Over the past years, due to rapid industrialization and advanced agricultural activities environmental deterioration is becoming a major concern. Water is one of the most important and basic natural resource which is being used in industries, agricultural activities as well as for the domestic and commercial purpose. These activities leads to discharge of wastewater, hence, accurate analysis of wastewater is crucial for maintaining the health and safety of the people. Water from all three sectors i.e. domestic, industrial and agriculture contribute into wastewater loads in the Najafgarh Drain in south-west Delhi. For this purpose the south-west Delhi stretch, near Dwarka, of the Najafgarh Drain was chosen to be analyzed for its wastewater quality parameters. On the same stretch of the Drain, treated wastewater from the Najafgarh Wastewater Treatment plant is also disposed. The present study deals with the comparison between the wastewater quality before and after the input of the treated drain water in the Drain. The flow and velocity of the drain water is estimated during the sampling period. The comparative analysis of the quality of wastewater before and after the Najafgarh Wastewater Treatment Facility indicates that there is positive improvement in the quality of water after the input of the treated wastewater, which is expected. These results can provide a basis for further studies and planning of facilities that can aid to solve the problem of deterioration of the natural resources and environment. Keywords: Water Pollution, Yamuna, Delhi, India *Ch. Brahm Prakash Govt. Engg. College, New Delhi Vol. 3 No. 10 October 2014 www.garph.co.uk IJAREAS 1

1.0 INTRODUCTION Today, surface water accounts for the majority of Delhi s water supply. In 2005-06, surface water accounted for 88% of the total water supplied to Delhi [1]. The stretch of River Yamuna within Delhi is 22 km long and is considered a major source of fresh portable water [2]. Of the surface water used to supply water to Delhi, 60% comes from the river Yamuna alone. In order to meet the drinking water requirement of the city, no freshwater is released from the upstream barrage at Wazirabad whereas a large quantity of wastewater is discharged further downstream through over 18 drains into the river. It should be noted that the total installed sewage treatment capacity in Delhi is 2,460 million litres per day (MLD) as against the sewage generation of about 3,800 MLD [2]. Presenting the report to a bench of Justices Swatanter Kumar and S J Mukhopadhaya, CPCB counsel Vijay Panjwani said, "Yamuna is a drain. Fresh water does not flow in the river except during monsoon. The entire flow of fresh water is harnessed at Wazirabad to provide drinking water to residents of Delhi." [3]. Najafgarh drain is the major source of pollution for River Yamuna. Najafgarh drain alone discharges about 2,000 MLD of waste water into Yamuna. Of this, only 600 MLD (30%) of waste water is treated through the installed wastewater treatment systems along the Najafgarh drain basin. It clearly indicates that there is huge amount of wastewater (approximately 1,400 MLD) which remains untreated. Further it should be noted that after treatment, the treated sewage from the sewage treatment plants is discharged in the Najafgarh drain. This leads to mixing of the untreated sewage with the treated, thereby defeating the very purpose of waste water treatment [2]. Due to this fact the stretch of area along the Najafgarh drain has become a concern for environment and health. 1.1 NAJAFGARH DRAIN Najafgarh Drain originates in Alwar-Rewari region of Rajasthan and Haryana in the Arawali Hills. As shown in Figure 1, it enters National Capital Territory (NCT) of Delhi on the south western side and traverses a length of 40 km before joining Yamuna in the north. Vol. 3 No. 10 October 2014 www.garph.co.uk IJAREAS 2

Najafgarh Treatment Plant Figure 1: Location of Najafgarh Drain in Southwest Delhi The severed catchment area of the Drain is approximately 400 km 2. Due to severe constraints in the sewerage system, the Najafgarh Drain carries large amount of raw sewage. Figure 2 shows the dirty water presently flowing through the Drain. Figure 2: Dirty water in the Drain Vol. 3 No. 10 October 2014 www.garph.co.uk IJAREAS 3

In addition, it receives treated effluent from various Sewage Treatment Plants (STP's) and freshwater from Western Yamuna Canal. The combined discharge is over 2100 Million Litre per Day (MLD) out of which about 600 MLD (30%) is treated which represents 50% of hydraulic load and over 25% of inorganic load from NCT Delhi into river Yamuna [4]. The flow in Najafgarh Drain is divided into three Stages. The Background Flow is about 150 MLD before the drain enters into NCT Delhi. Almost 40% flow is untreated while the rest 60% is discharged after conventional treatment [5]. This water has a BOD of around 100 mg/l. Next is the flow that originates from Delhi. Due to limited sewerage systems, large quantities of untreated sewage from the secondary drains enter the Najafgarh Drain. As per a study, 38 out of the identified 48 secondary drains carry significant flows [6]. Water from all three sectors i.e. domestic, industrial and agriculture contribute into wastewater loads in the Najafgarh Drain. The largest contributor is the domestic sector due to a large population living around the drain. Around 1340 MLD wastewater is discharged from the domestic units followed by 150 MLD from industries and a negligible contribution from agriculture. Approximately 78% of BOD is contributed by the Domestic sector. All these sources and various anthropogenic activities are adding harmful substances, oxidized organics, inorganic, suspended solids, sewage and harmful pathogens into the Najafgarh Drain. In the final stage, dilution of waste water takes place due to addition of 450MLD fresh water from the Western Yamuna Canal. Here BOD dilution of about 65% takes place just at the outfall into river Yamuna and is reported to be 125 mg/l [6]. 2.0 SCOPE OF THE PROJECT A number of wastewater treatment plants have sprung up around the Drains in Delhi yet no significant impact has been observed on the overall water quality in the drains. Therefore, the scope of the project was to analyze Najafgarh Drain for its water quality in order to contribute to studies concerning wastewater monitoring and management. This study also aims at providing a vision to encourage further studies and planning of facilities that can aid to solve the problem of deterioration of the natural resources and environment. Vol. 3 No. 10 October 2014 www.garph.co.uk IJAREAS 4

3.0 SAMPLING International Journal of Advanced Research in ISSN: 2278-6252 3.1 SAMPLING LOCATION Two sampling locations were chosen, the 1 st Sampling Station was after the Najafgarh Sewage Treatment Plant, named as, After Confluence and the 2 nd Sampling Station was before the Najafgarh treatment plant, named as, Before Confluence, in the rest of the paper. The locations of the sampling points are shown in Figure 3. Figure 3: Locations of sampling points 3.2 SAMPLING PROTOCOL The protocol adopted for sampling was taken from the CPCB s Guide Manual: Water & Wastewater Analysis, 2011. The method adopted for sampling was Composite Sampling. Composite Samples provide a more representative sampling of heterogeneous matrices in which the concentration of parameters of concern may vary over short periods of time or space. Composite Samples can be prepared by combining portions of multiple Grab Samples. In this study, 8 samples were collected on hourly basis once in a week over a period of 6 weeks, from 10:30-17:30 hours. A representative sample was then prepared by mixing 100ml of each sample obtained over the day [7]. A sampling depth of 0.6m (i.e.2ft) was maintained during sampling. 3.3 SAMPLE TESTING The Sample Testing Procedures were taken from the CPCB s Guide Manual: Water & Wastewater Analysis, 2011. The samples collected were tested for various Wastewater Vol. 3 No. 10 October 2014 www.garph.co.uk IJAREAS 5

parameters like Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD) by Open Reflux Method and Nitrates by UV Spectrophotometer at 220 nm. The other parameters which were tested were ph, Dissolved Oxygen (DO), and Total Dissolved Solids (TDS). 4.0 MEASUREMENT OF FLOW AND VELOCITY The flow of the drain was determined by Velocity Area Method, taken from the CPCB s Guide Manual: Water & Wastewater Analysis, 2011. In this method the discharge of water (m 3 /s) was estimated based on the velocity of the water and the cross-sectional area of the drain. Velocity was calculated using a floating Ball which acted as a surface float. The float was allowed to float over a length of 20 m and time taken by the ball to travel this distance was recorded. Furthermore the cross-sectional area of the drain was calculated by measuring the dimensions (width and depth) of the Drain. Hourly flow measurements were carried out on the days of sampling itself and the results were noted. 5.0 RESULTS AND DISCUSSIONS The results obtained for various parameters of representative samples tested are discussed below:- Legends for result interpretation : [S1 - Sampling Station 1 - After Confluence ; S2- Sampling Station 2- Before Confluence] 5.1 DISSOLVED OXYGEN (DO) The results show that DO varied between 5.3 mg/l to 5.7mg/L in the samples collected after confluence, as shown in Figure 4, whereas in the samples collected before confluence, the DO varied between 3.7mg/L to 4.7mg/L (Figure 4). The higher values of DO obtained after confluence indicate that the water is cleaner as compared to water before confluence. This probably is because of the dilution of drain water after getting mixed with the cleaner discharge from the Najafgarh Sewage Treatment Plant. Vol. 3 No. 10 October 2014 www.garph.co.uk IJAREAS 6

6 5 DO (mg/l) 4 3 2 1 0 Week 1 Week 2 Week 3 Week 4 Week 5 Week 6 Figure 4: DO Variations The DO level after confluence is more than 5mg/L and therefore is not expected to contribute stress to aquatic life but the DO values before confluence is less than 5mg/L which may impact aquatic life negatively. The DO values observed during morning hours were relatively lower than DO values of the subsequent hours. This can be attributed to the fact that during night time photosynthesis does not occur in plants and the oxygen present in the stream is consumed by the microbes to meet the oxygen demand leading to Anaerobic Conditions. Foul smell around the drain was sensed in the morning hours which could be due to the development of anaerobic conditions. 5.2 BIOCHEMICAL OXYGEN DEMAND (BOD 5 ) Similar to DO, it was observed that the value of BOD was lower in samples collected after confluence than the samples which were collected before confluence which probably can be attributed to the fact that water after confluence is diluted due to mixing with discharges from Najafgarh Sewage Treatment Plant of capacity 5MLD. The high BOD value in the samples collected before confluence can be attributed to the presence of high amount of organic waste (Domestic Sewage) and a high concentration of nutrients such as Nitrates and Phosphates which allow the microorganisms to flourish and decompose organic wastes in water [8]. Vol. 3 No. 10 October 2014 www.garph.co.uk IJAREAS 7

300 250 BOD 5, mg/l 200 150 100 50 0 Week 1 Week 2 Week 3 Week 4 Week 5 Week 6 Figure 5: BOD 5 Variation 5.3 NITRATE It was observed that the nitrate values ranged between 7-8 mg/l (Figure 6). For reference purposes it should be noted that the nitrate levels in the drain is below the discharge limits for nitrate for treated wastewater which is 10 mg/l [9]. 8.5 8 Nitrate (mg/l) 7.5 7 6.5 6 Week 1 Week 2 Week 3 Week 4 Week 5 Week 6 Figure 6: Nitrate Variation 5.4 TOTAL DISSOLVED SOLIDS (TDS) Similar to DO and BOD, it was noted that the quality of water was improved after the treatment plant. TDS level was found to be almost double at the sampling station before confluence as compared to the TDS of the samples collected after Confluence. This is probably due to the dilution of drain water polluted with high amount of raw domestic Vol. 3 No. 10 October 2014 www.garph.co.uk IJAREAS 8

sewage, caused by the mixing of effluent coming from the Najafgarh wastewater treatment plant. 3000 TDS(mg/L) 2000 1000 0 week 1 week 2 week 3 week 4 week 5 week 6 Figure 7: Variation in TDS 5.5 CHEMICAL OXYGEN DEMAND (COD) The average value of COD before confluence is around 600 mg/l whereas the average COD value after confluence is around 125 mg/l. This shows that the water after confluence is cleaner because of mixing with the discharge from the Najafgarh waste water treatment plant. All the water quality parameters above show a positive impact of the treatment plant on the Drain water quality. 1000 800 COD(mg/L) 600 400 200 0 Week 1 Week 2 Week 3 Week 4 Week 5 Week 6 Figure 8: Variation in COD 5.6 FLOW The velocity and the flow of the drain were calculated using the hourly sample data. It was observed that the flow peaks during midday. The velocity in the drain was observed to be in Vol. 3 No. 10 October 2014 www.garph.co.uk IJAREAS 9

the range between 0.27m/s to 0.29m/s. The average flow in the drain was seen to be between 55m 3 /s to 65m 3 /s. Flow (m 3 /sec) 80 75 70 65 60 55 50 45 40 10:30 11:30 12:30 13:30 14:30 15:30 16:30 17:30 29-Sep-13 06-Oct-13 20-Oct-13 6.0 CONCLUSIONS Figure 9: Flow Variation Sampling was done for two months and the results were analyzed. It was also observed that velocity and the flow of the drain was maximum during mid day. The average velocity in the drain was observed to be between 0.27m/s to 0.29m/s. The average flow in the drain was seen to be between 55m 3 /s to 65m 3 /s. The values of BOD 5, COD and TDS in the samples collected before confluence were substantially higher than the values obtained in the samples collected after confluence. It was also observed from the results of the samples collected after confluence that D.O. varied between 5.3mg/L to 5.7mg/L whereas before confluence D.O. varied between 3.7mg/L to 4.7mg/L. It should be noted that the water quality before and after the Najafgarh Sewage Treatment Facility differ substantially. All the data conclusively shows that the water in the Drain was comparatively cleaner before the input of the treated wastewater from the Wastewater Treatment facility. REFERENCES [1] Sewage Canal: How to clean the Yamuna, a book by Centre for Science and Environment, published in 2007 [2] Central Pollution Control Board interim report on Yamuna, 2012. Vol. 3 No. 10 October 2014 www.garph.co.uk IJAREAS 10

[3] A report by Dhananjay Mahapatra published in The s of India, November 2012. [4] Wastewater management in Najafgarh Drainage basin-asit Nema, Foundation for Genentech Environment System. [5] Central Pollution Control Board annual report, 2001-2002 [6] Water and Power Consultancy Services (WAPCOS) report, 1999 [7] Field Sampling Guidance Document #1225 on SURFACE WATER SAMPLING published by U.S.EPA REGION 9 LABORATORY, Richmond, California [8] Pre-drill EIA report by Assam Pollution Control Board [9] http://bcn.boulder.co.us/basin/data/bact/info/do.html Vol. 3 No. 10 October 2014 www.garph.co.uk IJAREAS 11