New Product Announcement



Similar documents
Pyroguard Wired Glass

FIRE GLASS TO GO! Fire Glass Solutions from

2010 edition. Handbook of. Fire-Rated Glass. for schools

The 60 minute Fire Rated Application Explained

FAQ S FREQUENTLY ASKED QUESTIONS ABOUT FIRE AND IMPACT/SAFETY RATED GLAZING PRODUCTS

Fire-Rated Glass and Glazing START

From Wired Glass to Clear Solutions: Designing with Fire Rated Glass Today

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

Basic Fire Door Requirements

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Technical Data Honeycomb Door Leaf

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010

Pilkington Reflite Handling and Processing Guidelines Solar Control

3 Scotch-Weld TM. Structural Adhesive Films AF 6 AF 10 AF 13. Technical Data July, 2001

SECTION GUARDA SECURITY WINDOW SCREENS

PYROSWISS VETROFLAM CONTRAFLAM

ENERGY SAVING WINDOW FILMS S LAR CONTROL

Wetroom Panel (Concealed Fix)

Important Information

Glass and Building Regulations Impact Safety

Standard Specification for Flat Glass 1

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

FIRE RATED GLAZING System Guide

Basement Window Installation Guide Hopper and Sliding

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

Scotchgard Multi-Layer Protective Film 1004

Gridstone Gypsum Ceiling Panels

CHAPTER 24 GLASS AND GLAZING

FIRESTOPPING & SMOKE SEALS

A. Work on this project shall consist of, but is not limited to, the following:

Office of the State Fire Marshal. Fire Rated Doors

HEAT WAVE DUCT KIT KIT #

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

INTEL S SAFETY WARNING LABEL REQUIREMENTS

Built to Last. Built for Beauty. Good. Solid. Logix. TM

IMPORTANT INFORMATION

Apr 17, 2000 LAB MANUAL

Steel Door Institute. Fire Rated Doors and Frames

Installation Guide of Sunrise Solartech PV Modules. Term Contents. Purpose of this guide. General. Safety precaution for installing a solar

Teach me about Glazing

Fire Barriers & Fire Stopping

Thermo-Flo Basement Waterproofing System. B-Dry System, Inc. 455 South 4th Street, Suite 350 Louisville, KY 40202

TECHNICAL BULLETIN TECHNICAL DESCRIPTION DESCRIPTION OVERVIEW PROGRAMS. Data Sheet. Pilkington Toughened Safety Glass

Underwriters Laboratories Testing Information

SPECIFICATION Aluminum Module Frames. Allowed anodization before fabrication for clear frames.

Test Report No. C829QPEN

GENERAL INSTALLATION MANUAL FOR EGING PV MODULES

SECTION METAL WALL PANELS

Ceramic Glass Electric Galley Ranges

Automatic Door Selection Guide

POZZI WINDOW COMPANY LIMITED WARRANTY WINDOWS, DOORS AND COMPONENT PARTS

FIRE-RESISTANT GLAZING Mr Leslie O May Sales Consultant Wright Style Limited England

Model KFR56 Series Quick Response Standard Spray

TECHNICAL DATA RS European Clear EZ N. Webster Street Dayton, OH Phone Toll Free Fax

Section Polished Concrete Finishing. Vexcon

Spandrel Glass Types and Recommendations

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS PHILLIP STREET, SYDNEY

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Fire-rated Aluminum Doors

1.1.2 Polypropylene The polypropylene must be a white opaque film, 1 2 mil thick. Biaxial orientation is preferred.

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24,

SOLAR PV SYSTEM MAINTENANCE GUIDE

3/4 PIPE CLAMP WITH STAND

BENTLEY ELEMENTS COLLECTION LVT

Double Coated Urethane Foam Tapes

Terms and Definitions In Canada

QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS

Specifying Windows. Performance Standards

White rust on galvanized and galvanized pre-painted steel. Technical Information

BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS

Dot matrix Label ID Products. C Vinyl cloth labels. Dot Matrix. Features and benefits. Part numbering system

1.4 Metallic Impurities Iron must not exceed 150 ppm and copper shall not exceed 6 ppm when tested according to TAPPI T 266.

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

FLEX-WRAP Foam Pipe Wrap

Fiberglas, Exterior Wall Thermal Insulation

VERTICAL DESIGN OPTImAL ACOUSTICS

Fire Barrier Duct Wrap 15A

3 Single-Coated Foam Tapes

Scottsdale, Arizona. Presentation by: Hermes Norero, P.E. President and CEO

Subject: DKS Steel Door and Frames Systems, Inc., ITS / Warnock Hersey Procedural Specification, Certification, and Inspection.

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Sash or Balance Replacement Guide

INSTALLATION INSTRUCTIONS

COMPACT LABEL APPLIER

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

PACKAGING & MATERIALS TESTING SERVICES

RAILWAY EQUIPMENT REFLECTORIZATION RULES

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

Transcription:

New Product Announcement Tristar Glass is now the exclusive provider of Schott PYRAN Platinum Fire- and Safety-Rated Glass-Ceramics for Arkansas, Oklahoma, and Texas. Tristar is giving our select network of glaziers immediate access to cutting-edge, UL-certified, fire-rated glass in 3 options: monolithic, filmed, and laminated. Outlined in this brochure are the reasons Schott s PYRAN Platinum fire- and safety-rated glass-ceramics are the best choice for your fire-protective glazing project. Clearest Glass-Ceramic available no yellow or orange tint No wires means no danger and no unsightly lines In-Stock and Ready-To-Go; no more long lead times and cross-country freight and boxing fees UL certified and passes required hose stream test PYRAN Platinum F and L pass ANSI Z97.1 and CPCS 16CFR1201 (Cat I and II) impact testing and are approved for hazardous areas Cradle-to-cradle (C2C) Silver Certified meaning good for the environment and qualifies for LEED credits Can be used to construct insulated glazing units Simplified Ordering Process By answering a few basic questions your Tristar Glass sales representative will have all the necessary information to quote your fire-rated glass project: 1. Determine glass quantities and sizes 2. Determine if any of the glass is in a door or side-lite application, or if it can be annealed 3. Determine the appropriate fire rating requirement 1120 Main Parkway Catoosa, OK 74015 tristarglass.com 866.655.1624 918.739.3611 918.739.3620 fax 866.875.9513 toll free fax

PYRAN Platinum Glass Options By stocking all three of Schott s PYRAN Platinum glass products, Tristar gives you the flexibility to find the right fire-rated glass type that adequately meets the required fire standards of your project while minimizing the impact to your wallet. Below is a short outline of the three available products and their most common uses. Monolithic PYRAN Platinum monolithic fire-protection rated glazing material is 3/16 (5mm) thick and weighs 2.5 lbs/ft2. It is intended for use in non-impact, non-safety-rated locations such as transoms and windows with fire-rating requirements up to 90 minutes. Maximum sheet sizes: Approximately 43 x 77 Impact rating: None Filmed PYRAN Platinum F fire-protection rated and impact safety-rated glazing material is 3/16 (5mm) thick and weighs just 2.5 lbs/ft2. It has a surface applied safety film and is intended for use in safety-rated locations such as door lites, transoms or sidelites, and windows with fire-rating requirements up to 90 minutes (180 minutes in doors). Maximum Sheet size: Approximately 43 x77. Impact rating: ANSI Z97.1 and CPSC 16CFR1201 (Cat. I and II) Laminated PYRAN Platinum L fire-protection rated and impact safety-rated glazing material is 3/8 (9mm) thick and weighs just 4.0 lbs/ft2. It is intended for use in safety-rated locations such as door lites, transoms or sidelites, and windows with fire-rating requirements up to 90 minutes (180 minutes in doors). Maximum Sheet size: Approximately 43 x77. Impact rating: ANSI Z97.1 and CPSC 16CFR1201 (Cat. I and II) STC Rating: Approximately 36 db MONOLITHIC FILMED LAMINATED

BENEFITS Acquaint Yourself with some of PYRAN Platinum s benefits and learn first hand why Schott s fire rated glass products are the best in the world. In Stock and Ready-to-Go Our ready-to-go stock of PYRAN Platinum fire-rated glass means no more long lead-times and cross-country freight fees. Get the glass you want, when you need it delivered on the same trucks you see every day. Clearly Defined Safety Schott PYRAN Platinum fire-rated glass-ceramic products represent the next generation of glass-ceramic technology, offering stunning optical quality, superior clarity, and virtually no distortion. Through recent advancements in micro-float technology, Schott has been able to eliminate the unsightly yellow and orange tints associated with other fire-rated glass and no longer require corrective polishing or grinding to achieve superb optical quality. All this helps to maximize natural lighting and views, eliminating compromises in spaces that otherwise would have sacrificed form for function. Wireless The 2006 International Building Code (IBC) no longer permits the use of wired glass in hazardous locations in all facility types. PYRAN Platinum F and L fire-rated glass-ceramic products provide glaziers with a wire-free, impact safety glazing that passes both the ANSI Z97.1 and the CPSC 16CFR1201 (Cat. I and II) and is approved for use in hazardous locations. Choose PYRAN Platinum, a superior fire-rated product, and avoid unsightly lines and the ever-growing negative stigma surrounding wired glass. Earn LEED Credits and Help the Environment PYRAN Platinum is the only fire-rated glass-ceramic that is made without the use of hazardous heavy metals such as antimony, arsenic, and barium. It is also the only glass-ceramic to receive a Cradle-to-Cradle silver level certification from the MBDC and qualify as one of the EPA s Environmentally Preferable Products (EPP), potentially earning a project up to 5 LEED certification points.

CERTIFICATION PYRAN Platinum Monolithic Rating (Min.) Location Max Exposed area of glazing (in. 2 ) Max width of exposed glazing (in.) Max height of exposed glazing (in.) Min depth of glazing channel Impact Safety Rated Up to 90 Other than Doors 3422 (23.7 ft2) 76 76 5/8 No PYRAN Platinum F Filmed PYRAN Platinum L Laminated Up to 90 Doors Non-Temp Rise 2736 (19 ft2) 36 76 5/8 Yes Doors Temp Rise and Up to 180 100 (.69 ft2) 12 33 1/2 Yes Non-Temp Rise up to 90 Other than Doors 3422 (23.7 ft2) 76 76 5/8 Yes Up to 90 Doors Non-Temp Rise 2736 (19 ft2) 36 75 5/8 Yes Doors Temp Rise and Up to 180 Non-Temp Rise 100 (.69 ft2) 12 33 1/2 Yes up to 90 Other than Doors 3143 (21.8 ft2) 75 75 5/8 Yes UL Certified PYRAN Platinum fire- and safety-rated glass-ceramics are Classified and labeled by Underwriters Laboratories, Inc. for the United States and Canada with File-No. R22036. All fire tests were performed in accordance with UL 9, UL 10B, UL 10C, UBC 7-2 (1997), UBC 7-4 (1997), NFPA 252, NFPA 257, NFPA 80, ASTM E 2010-01, ASTM E2074-00, ULC CAN4-S104, and ULC CAN4-S106 The Hose Stream Test and The Ability to Withstand Thermal Shock The hose stream test is a mandatory procedure required by The National Fire Protection Association (NFPA). Their standards for Window and Glass Block Assemblies state, the hose stream test provides a method for evaluating the integrity of constructions and assemblies and for eliminating inadequate materials or constructions. The cooling, impact, and erosion effects of the hose stream provide important tests of the integrity of the specimen being evaluated. The hose stream test is conducted by spraying 30psi water from a fire hose onto the glass while the glass and the framing system are still hot. The thermal shock created on the system during this test must not cause the glass to fail and, in turn, allow fire and smoke to spread. F I R E R A T E D G L A S S

Storage and Handling PYRAN Platinum fire- and safety-rated glass-ceramics should be handled with care during transportation, storage, inspection, and installation. It should be stored in dry conditions only and must be stacked upright or at a slight angle. In addition, an appropriate material, such as soft pads made of cork (Platinum and Laminated) or acid free tissue paper (filmed), must separate the panels and the bottom edge must be supported along its entire length. Installation GLAZING GUIDE PYRAN Platinum products shall only be installed into fire-rated frame and window assemblies carrying the same rating. Each panel should be inspected carefully before installation, and any pieces with visible edge or surface damage should be sorted out. All glazing components and the stop height must be chosen according to the PYRAN Platinum product classification. The panel must be placed on calcium silicate or hardwood setting blocks and glazed using PYRAN Platinum classified glazing tape, such as closed cell PVC, Fiberfrax tape or Pemko FG3000590. The installation of the framed unit must comply with the frame supplier s instructions. PYRAN Platinum products are specially developed glass-ceramics, which fulfill the fire protection rating requirements. The production process may create certain optical imperfections, such as bubbles or knots. Since these do not generally impair the transparency or the technical performance of the glass-ceramic, they do not represent cause for rejection or replacement. Maintenance and Care To maintain the aesthetics, it is important to keep the panel clean. A soft, non-abrasive cloth and a mild soap, detergent, or non-abrasive window cleaning solution is suitable for cleaning. After cleaning, rinse immediately with clean water and remove any excess water from the panel surface. Also, do not allow any metal or hard parts of the cleaning equipment to come in contact with the panel surface. 1120 Main Parkway Catoosa, OK 74015 tristarglass.com 866.655.1624 918.739.3611 918.739.3620 fax 866.875.9513 toll free fax

WARRANTY INDIVIDUAL PRODUCT WARRANTIES PYRAN Platinum Glass-Ceramic Limited 5-Year Warranty SCHOTT North America, Inc. ( SCHOTT ) warrants that, at the time of purchase from SCHOTT, the PYRAN Platinum glass-ceramic (the Product ) will conform to SCHOTT s then current Product specifications. This warranty is only made to and is limited to the original purchaser of the Product from SCHOTT ( Purchaser ). No warranty claim is valid under this warranty unless the warranty claim is made within thirty (30) days of the date of purchase. PYRAN Platinum F Glass-Ceramic Limited 3-Year Warranty SCHOTT North America, Inc. ( SCHOTT ) warrants that, at the time of purchase from SCHOTT, the PYRAN Platinum F glass- ceramic (the Product ) will conform to SCHOTT s then current Product specifications. SCHOTT also warrants that for a period of three (3) years from the date of original purchase from SCHOTT (the Warranty Period ), the Product will maintain adhesion without crazing, delaminating, or peeling. These warranties are only made to and are limited to the original purchaser of the Product from SCHOTT ( Purchaser ). No warranty claim is valid under this warranty unless the warranty claim is made within thirty (30) days of either A) the failure of the Product to maintain adhesion without crazing, delaminating, or peeling or B) the date of purchase, if the claim is that the Product does not conform to SCHOTT s specifications. PYRAN Platinum L Glass-Ceramic Limited 5-Year Warranty SCHOTT North America, Inc. ( SCHOTT ) warrants that, at the time of purchase from SCHOTT, the PYRAN Platinum L glass-ceramic (the Product ) will conform to SCHOTT s current Product specifications applicable to the Product at the time of purchase. SCHOTT also warrants that, for a period of five (5) years from the date of the original purchase from SCHOTT (the Warranty Period ), the Product will be free from manufacturing defects that cause significant visual disruption through the glass area, delamination, or material changes to the properties of the interlayer. These warranties are only made to and are limited to the original purchaser of the Product from SCHOTT ( Purchaser ). No warranty claim is valid under this warranty unless the warranty claim is made within thirty (30) days of either A) the occurrence of significant visual disruption through the glass area, delamination, or material changes to the properties of the interlayer of the Product or B) the date of purchase, if the claim is that the Product does not conform to SCHOTT s specifications. MONOLITHIC FILMED LAMINATED Please Visit www.tristarglass.com for a complete listing of warranty terms and conditions.

CALL TODAY FOR A FREE QUOTE Toll Free Phone: 1-866-655-1624 Toll Free Fax: 1-866-875-9513 1120 Main Parkway Catoosa, OK 74015 www.tristarglass.com - sales@tristarglass.com FIRE RATED GLASS GUIDE