Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology



Similar documents
Plastic tube flowmeters Series PT/PS

Flow switches Series AD/VH

Operating Instructions for Plastic Flow Meter. Model: KSK

SITRANS F flowmeters SITRANS F M

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

How To Use A Flowmeter

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Safety at a high level!

Digital inductive conductivity transmitter

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Micro Motion Model D and DL Coriolis Flow and Density Meters

Turbine Flow Sensor Series VTR

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Variable V Area Flowmeter Rotameter The Original

Variable Area Flowmeters

Inductive sensor NI10-M18-Y1X-H1141

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Bypass level indicator With magnetic display Model BNA

Electromagnetic Flow Meter

4 Posiflow Proportional Solenoid Valves

Thermometer in stainless steel with capillary and switch contacts

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

RTD Temperature Probe for the Food/Pharmaceutical Industry

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Stainless steel process fittings

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

2/2 and 3/2 Way Size 6 Seat Valves

Hose and Tube Fittings Series 1-3

ELECTROMAGNETIC FLOWMETER COMPACT

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Givare NC-SRS 280 och 880

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Conductive Level Switch FK 2 Technical Data:

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Duct Humidity Transmitter

Fluxi 2000/TZ Turbine Gas Meter

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

3/2-way Solenoid Valve, direct-acting, NC or NO

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

SITRANS F flowmeters. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/12 Siemens FI

OLI. Oil level indicator

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Colima Visco and Colima Viscorol Magnetic Level Indicators

Compact pressure switch Flameproof enclosure Ex d Model PCA

Instruction Manual Differential Pressure Transmitter

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Magnetic Level Indicators. Indication Control Monitoring. Eisenbau

Electric Rotary Actuator - On/Off or programmable control actuator

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

System 8. ü ( System 8

Contents. Document information

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Self-operated Temperature Regulators Temperature Regulator Type 1u

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Datalogger DL/N 70 Version:

Electronic Flow Switches

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION TOR REED SWITCH

Cable Plug acc. to DIN EN , Form A

In addition to the basic models, it is also possible for the units to be outfitted with add-ons.

Data Sheet PS1B Pressure Switch

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

kymanual or Automatic - it s your Choice

2- and 3-port valves with flanged connections, PN 10

In-Line Electronic Flow Switches

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Instruction Manual. T3111 T3111L T3111P T3111Ex

VDL 53 - Vacuum drying oven for flammable solvents

9000 Series Accelerometers Specifications

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Pressure transmitter For general industrial applications Model A-10

Type 3353 Angle Seat Valve

KOBOLD VKP FLOWMETER/SWITCH. User Instructions

How To Use A Ds340 (Dsp)

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Hydraulic Control Solutions

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Magnetic Proximity Switches Series CST - CSV and CSH

FLOW SYSTEM flow measurement system in open channels and non-pressurized pipes

Digital display DA 48

Pressure switches for gas and air Pressure sensors

MFP14, MFP14S and MFP14SS Automatic Pumps

OPTIMASS 6000 Technical Datasheet

Transcription:

Plastic Flow Meters for gases & liquids, using TROGAMID* & POYSUFONE Technology Applications Monitoring & Control of processes for: Water & Waste Water Treatment Chemical, Petrochemical & Paper Pharmaceutical, Cosmetics & Synthesis Refrigeration & Air Conditioning Refining Osmosis Gas processes Benefits ow cost Excellent readability Scaled directly in l/h, m 3 /h, %, etc. Temperatures up to 60 o C TROGAMID*, and 90 o C POYSUFONE Pressures up to 15 bar Simple installation (flanged, threaded or glued connections) ight weight High & ow Flow Switches 4-20 ma Output (18 points max.) (On request HART, PROFIBUS, FIEDBUS protocols) * TROGAMID is a registered trade mark of Dynamit Nobel.

Type AC Reading line Type ACT Measurement Principle Variable area flow using a float in a tapered tube made from special plastic materials. Operation The fluid flows up through the tapered tube forcing the float to a position with sufficient free area to enable the flow to pass. This free area is related to the flow rate, the weight of the float and the density and viscosity of the fluid. The pressure drop across the flow meter remains constant over the entire flow range. This occurs because the pressure drop is related to the fluid velocity and area of flow, the area of flow increases as the flow rate increases. Reading Reading Technical Data Connections: PT-11 & PS-31: Threaded or glued fittings from 1/2 to 3 BSPF PT-12 & PS-32: Flanges DN 15 to DN 80, PN 10 PTM-01 & PSM-21: Threaded or glued fittings of 1/2 and 3/4 BSPF PTM-02 & PSM-22: Flanges DN 15 and DN 20, PN 10 Other connections available on request ength (in mm) Minimum Maximum PT-11 340 414 PT-12 390 538 PT-12 (BR) 380 420 PTM-01 / PSM-21 232 +1 mm PTM-02 / PSM-22 260 +1 mm Accuracy: PT & PS: According to Standards VDE / VDI Class 4 PTM & PSM: According to Standards VDE / VDI Class 6 Scales calibrated directly in l/h, m 3 /h, % Scale length: PT & PS: 160 +5 mm PTM & PSM: 100 +5 mm Rangeability: 10:1 Pressure: up to 15 bar @ 20 o C NOTE: a more cost effective PTM Series flow meter is available from stock, the model PTM-03 with NAS 30 clear performance plastic. Available flow rates and options, same as PTM Series. Temperature imits: PT-TROGAMID T tubes: 60 o C PS-POYSUFONE tubes: 90 o C PTM-TROGAMID T tubes: 60 o C PSM-POYSUFONE tubes: 90 o C PVC fittings: max. 55 o C PP fittings: max. 90 o C Materials: Flow tube Fittings Float Float Stops PT-TROGAMID T EN 1.4404 (SS-316) PVDF+ ead PS-POYSUFONE PVC Aluminium PP PTFE PVDF PTM-TROGAMID T SS-316 PTFE+ead Steel PVC PSM-POYSUFONE PVC + ead Alarm Options: PT-AMR 1...2 Magnetic actuated reed switch Transmitter Options: PT-TMUR 0...4-20 ma (16...18 points resolution for Series PT-PS) PTM-TMUR 0...4-20 ma (11 points resolution for Series PTM-PSM) NAS is a registered trade mark of NOVA Chemicals Inc. 2

PT-11, PS-31/PTM-01, PSM-21 PT-12, PS-32/PTM-02, PSM-22 PT-12(BR), PS-32(BR) Nº Item PT-11/12,PTM-01/02,PT-12(BR) PS-31/32,PSM-21/22,PS-32(BR) On demand 1 Flow tube TROGAMID T POYSUFONE PVDF 2 Float EN 1.4404 (SS-316), EN 1.4404 (SS-316), PTFE, PTFE+ead, PVDF+ead, Aluminium PVDF+ead, Aluminium Hastelloy, Titanium 3 Fitting PVC PVC PP, Steel, SS-316 4 Nut PVC PVC PP, Steel, SS-316 5 Gasket NBR NBR Viton, EPDM 6 Float Stop PVDF PVDF - 7 Flow Indicator PVC PVC - 8 Tube Union PVC PVC - 9 Flange (glued) PVC PVC - 10 Flange Neck PVC PVC PP PTM + PTM-TMUR PTM + PTM-AMR PT + PT-TMUR PT + PT-AMR 3

PT-11 / PS-31... PT-12 / PS-32... PT-12(BR) / PS-32(BR) Flow Tube Measuring Ranges vs Float Type AC Max. P mm H 2 O Tube Series Series PT Operating PT-11 Series PS* Pressure PT-12 EN 1.4404 AUMINIUM PS-31 7.95 g/cm 3 2.85g/cm 3 Float PS-32 PT-12(BR) Model Nº Water 20 o C Air@STP Air@STP ength PS-32(BR) l/h Nm 3 /h Nm 3 /h bar EN 1.4404 AUM. mm Min. Max. Min. Max. Min. Max. (+1mm) DN E PT-312-0160 (1) * 16 160 - - 0.6 6 15 90 (1) - 300 15 20 PT-312-0250 (1) * 25 250 - - 1 10 15 90 (1) - 300 15 20 PT-313-0400* 40 400 1.1 11 0.7 7 15 125 50 300 20 25 PT-313-0630* 60 630 1.8 8 1 10 15 125 50 300 20 25 PT-313-1000* 100 1000 3 30 1.7 17 15 125 50 300 20 25 PT-314-1600* 160 1600 4.5 45 2.5 25 10 175 75 300 25 32 PT-314-2500* 250 2500 7 70 4 40 10 175 75 300 25 32 PT-315-4000* 400 4000 11 110 7 70 10 230 95 300 40 50 PT-315-6300* 500 6300 18 180 10 100 10 230 95 300 40 50 PT-316-6300 500 6300 18 180 10 100 10 300 125 300 50 63 PT-316-M010* 1000 10000 30 300 17 170 10 300 125 300 50 63 PT-316-M014* 2000 14000 120 420 45 200 10 300 125 300 50 63 PT-317-M016 1600 16000 45 450 25 250 8 400 170 300 65/80 75/90 PT-317-M020 2000 20000 60 600 35 350 8 400 170 300 65/80 75/90 PT-317-M025 2500 25000 70 700 40 400 8 400 170 300 65/80 75/90 PT-317-M030 3000 30000 90 900 50 540 8 400 170 300 65/80 75/90 PT-317-M040 6000 40000 180 1200 100 712 8 400 170 300 65/80 75/90 PT-317-M040 (3) 8000 50000 240 1500 150 900 8 400 170 300 65/80 75/90 (1) With PTFE float (2) NOTE: for PT and PS Series, all plastic loaded floats are in PVDF+ead, except for the tubes with model nº PT-316-M014, PT-317-M016, PT-317-M020, PT-317-M025, PT-317-M030, PT-317-M040 where the material for the float is PVC+ead (3) Fits special float to reach higher flow rate * Flow tube available in Polysulfone PTM-01 / PSM-21... PTM-02 / PSM-22 Flow Tube Measuring Range vs Float Type AC Max. Pressure Drop Tube Series Series PTM Pressure P mm Water PTM-01 Series PSM* PTM-02 EN 1.4404 (1) Aluminium PSM-21 7.95 g/cm 3 2.85 g/cm 3 Float PSM-22 Model N o Water 20 o C Air @ STP Air @ STP ength I/h Nm 3 /h Nm 3 /h bar EN 1.4404 (1) Al mm Min. Max. Min. Max. Min. Max. (+1mm) DN E PTM-312-0040 (2) * 4 40 - - 0.12 1.5 15 (2) 30-192 15 20 PTM-312-0060 (2) * 6 60 - - 0.2 2 15 (2) 30-192 15 20 PTM-312-0100* 10 100 0.3 3 0.15 1.8 15 90 35 192 15 20 PTM-312-0160* 16 160 0.5 5 0.25 2.5 15 90 35 192 15 20 PTM-312-0250* 25 250 0.7 7 0.4 4 15 90 35 192 15 20 PTM-313-0400* 40 400 1.1 11 0.7 7 15 125 50 192 20 25 PTM-313-0630* 60 630 1.8 8 1 10 15 125 50 192 20 25 PTM-313-1000* 100 1000 3 30 1.7 17 15 125 50 192 20 25 (1) EN 1.4404 = SS-316 (2) With PTFE float * Flow tube available in Polysulfone 4

PT-11 / PS-31 Rp = DN E RE A 1 2 H 1/2 15 20 1 43 340 300 307 17 3/4 20 25 1 1/4 53 346 300 309 19 1 25 32 2 74 352 300 311 22 1 1/2 40 50 2 1/4 80 366 300 314 31 2 50 63 2 3/4 99 372 300 314 38 2 1/2 65 75 4 135 378 300 318 44 3 80 90 4 135 414 300 318 51 PT-12 / PS-32 & PT-12(BR) / PS-32(BR) DN E D k g lxnº B (BR) 15 20 95 65 45 14x4 12 390 380 20 25 105 75 58 14x4 13 396 380 25 32 115 85 68 14x4 15 412 390 40 50 150 110 88 18x4 17 446 400 50 63 165 125 102 18x4 20 458 41 65 75 185 145 122 18x4 21 490 420 80 90 200 160 138 18x4 22 538 420 PT-11 Ø A PT-12 Ø D PT-12(BR) Ø RE Ø K PS-31 PS-32 PS-32(BR) Ø g Ø E Ø E Rp DN DN H B B 2 1 PTM-01 / PSM-21 Rp = DN E RE A 1 2 H 1/2 15 20 1 43 232 192 198 17 3/4 20 25 1 1/4 53 232 192 198 19 PTM-02 / PSM-22 DN E D k g lxnº B 15 20 95 65 45 14x4 12 257 20 25 105 75 58 14x4 13 260 PTM-01 PSM-21 Ø A Ø RE Ø E Rp PTM-02 PSM-22 Ø D Ø K Ø g Ø E DN H B 2 1 5

Adjustable imit Switches PT-AMR (from 25-250 l/h H 2 O, and 0.8-8 Nm 3 /h air) Adjustable imit Switches PTM-AMR (from 6-60 l/h H 2 O, and 0.2-2 Nm 3 /h air) Reed switch, actuated by a magnet inside the float. Mounted within a PVC enclosure: PT-AMR & PTM-AMR 1...2 Adjustable reed switches Operation: The contact is normally open, when not in alarm condition Maximum Flow: On increasing flow, the contact closes when the float reaches the height of the alarm sensor. It remains closed while the float is above the sensor. It opens again when the flow reduces and the float returns below the sensor. Minimum Flow: On reducing flow, the contact closes when the float reaches the height of the alarm sensor. It remains closed while the float is below the sensor. It opens again when the flow increases and the float rises above the sensor. Normally Closed reed switches are available on order. Technical Characteristics Material: PVC housing Ambient temperature: -15 to 60 o C Contact rating: 0.5 A / 250 VDC / 12 VA Hysteresis: +5% of full scale value Ingress protection degree: IP65 DIN 43650-A connector, PG9 cable gland Conforms to 73/23/EEC Directive Electrical Connection In the female connector (A): Terminal 1: Reed switch contact Terminal 2: Reed switch contact Terminal 3: No connection Earth terminal: No connection 2 3 1 Mounting Once the electrical connection has been made and the cable gland has been tightened, mount the female connector (A) on the male base (C), placing the seal (B) between the two pieces. A B To fix the limit switch in its position on the flowmeter, unscrew the screw (E) to release the bracket (D), situate the limit switch on the desired point at the tube and reassemble the bracket by tightening the screw (E). PTM/PSM PT/PS PT-11/12...PS-31/32 & PTM-01/02...PSM-21/22 DN 15 20 25 40 50 65 80 R 1/2 3/4 1 1 1/2 2 2 1/2 3 A 47 52 62 70 70 90 90 C 18 42 70 9,5 D A E 6

Transmitter PT-TMUR 0/4-20 ma (16...18 point) (from 25-250 l/h H 2 O and 0.8-8 Nm 3 /h air) Transmitter PTM-TMUR 0/4-20 ma (11 points) (from 6-60 l/h H 2 O and 0.2-2 Nm 3 /h air) The TMUR electric transmitter consists of a chain of reed switches which is mounted inside a plastic enclosure IP-65 rated which is attached to the side of the flow tube and a separated converted TR420 which converts the resistance in to current (0...4-20 ma). The converter TR420 can be installed by means of screws or in a DIN 46277 rail. TR420 Converter Technical Data: Power supply: 110, 230, 240, 24 V ac 50/60 Hz 24 V dc Max. Power: < 1 VA Accuracy: +0.1% Working Temperature: 0 o C +60 o C Electrical connection: 4 wires, standard 2 wires, on demand Resolution: 10 mm (On request HART, PROFIBUS, FIEDBUS protocols) PTM/PSM + PTM-TMUR TR420 Converter TR420 (converter Ω/mA) Information for order a / vvv PT/PS + PT-TMUR PT-11/12... PS-31/32 y PTM-01/02... PSM-21/22 DN 15 20 25 40 50 65 80 A 95 105 110 120 130 145 145 PT-11/PS-31... PT-12/PS-32 with TMUR PTM-01/02... PSM-21/22 55 75 110 4,5 x 6 37,5 61,2 a = Output signal = A 0-20 ma = B 4-20 ma = D 0-5 V dc = E 0-10 V dc = F 1-5 V dc = G 2-10 V dc vvv = Supply = 110 110 V ac 50/60 Hz = 220 220-230 V ac 50/60 Hz = 240 240 V ac 50/60 Hz = 024 24 V ac 50/60 Hz = 24d 24 V dc A 30 *PTM... PSM 139 mm 48 DN15 - DN50 = 215* DN65 - DN80 = 195 7

Optional connections PT-11/INOX (SS 316 = EN 1.4404) Rp 1/2... 3 BSP/NPT PT-11/INOX (SS 316 = EN 1.4404) for welding DN15... DN80 PT-11/PP Rp 1/2... 3 BSP PT-11 with nuts in PVC and metallic end connectors: PT-11/Fe, end connector in steel PT-11/INOX, end connector in SS 316 = EN 1.4404 Rp 1/2... 3 BSP/NPT R+D, Manufacturing and assembly workshop Machine shop Sales department and calibration facilities Glass workshop Ref. PT- 02/06 P-3481 Bosmanskamp 30, 4191 MV Geldermalsen Tel. +31 (0) 345 596 000 Fax +31 (0) 345 596 001 www.adinco.nl info@adinco.nl