Electric Flow Boiler



Similar documents
Electric Flow Boiler

Electric Flow Boiler

INSTALLATION & TECHNICAL MANUAL

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

UNDERSTANDING CENTRAL HEATING SYSTEMS

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump

The complete range of hot water and heating solutions from the Electric Heating Company.

Link-Up. Solid Fuel Association Guide to Central Heating.

ELECTRIC CENTRAL HEATING FLOW BOILER

Natural geothermal energy.

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS

Daikin Altherma Hybrid Heat Pump

Installation & User Instructions

CALEFFI. SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production. SATK20 - SATK30 series 01209/13 GB

StainlessLite. Unvented mains pressure and vented water storage in Duplex stainless steel SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

ECOCIAT. Domestic hot water heat recovery unit

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

GRANT. Vortex Condensing Oil Boilers. USER, INSTALLATION and SERVICING INSTRUCTIONS

User's Instructions. Alpha HE CB25/33 and HE SY25

Gas Condensing Boilers

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS

For installation guide see reverse of book

High Output Boiler Systems

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Air Source Heat Pump Installation and Maintenance Manual

Response: The combi boiler. Response: The fit anywhere combi

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

High Efficiency Boiler Range Technical Guide

SOLAR HEATING SYSTEMS.

HEAVY DUTY STORAGE GAS

building engineering services association specification for: Domestic Heating

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

ROTEX gas hybrid heat pump. A strong team.

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Session 2: Hot Water Supply

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Fully Pumped Systems

Daikin Altherma hybrid heat pump. The natural combination

Stove-boiler for solid fuels KW Directions for use and assembling

ALFEA HYBRID DUO GAZ. New Model 2011

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

Laddomat Charging unit

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

Baxi Combi 80e & 105e

Technical data. Danfoss DHP-A

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza (Spain) Tel.: Fax:

Megalife Vented Cistern Fed Water Heater Installation manual

BoilerMate SP. benchmark. user instructions A - C L A S S

Itho Products for Hot and Boiling water. product-

HEAT INTERFACE UNITS (Modular)

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

2.0 Technical Details 2.1 Combi Sequence of Operation Flow Chart Dimensions Flue Options & Dimensions Technical Data...

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

Rotary screw compressors kw 5,5 7, , bar MODULO

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

Mikrofill Ethos Condensing combination boiler

Description of functions

Operating instructions

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

The natural ombination

Water Heating Catalogue

AMBASSADOR (KITCHEN), COUNTRYMAN (OUTDOOR) & CONSUL (BOILERHOUSE) CONSENSING BOILERS SENATOR (KITCHEN) & COUNTRYMAN (OUTDOOR) COMBI CONSENSING BOILERS

LK Electric Boiler - 4,5

SYSTEM BOILER ESTIMATES!

PRESSURISATION UNITS EXPANSION VESSELS ELECTRONIC FILLING DEVICE (EFD) MAXI MAXI PLUS EXPANSION VESSELS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Technical Data Manual Model Nos. and pricing: see Price List

Conlift1, Conlift2, Conlift2 ph+

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Create the right atmosphere with renewables.

Clearly Hybrid system

AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS

AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS

Working towards a cleaner future. 30 to 4000kW. Condensing Aluminium 30 to 600kW. Condensing Stainless Steel 50 to 160kW

The Best Selling Domestic Stainless Steel Oil Boiler

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Typical condensing boilers can have an efficiency rating of 89% and up, which is 25% more efficient than a non-condensing boiler.

Hybrid heat pumps. saving energy and reducing carbon emissions

STOVE-BOILER FOR SOLID FUELS Directions for use and assembling

Marine Generating Sets 3.7 to 50 kva

FilterFlow Automatic Water Boilers. Pure Quality

ASME Packaged Indirect Fired Water Heater

H I G H S P I N W A S H E R E X T R A C T O R S H C 6 0 H C 6 5 H C 7 5 H C H C H C 1 6 5

HERZ-Thermal Actuators

SF15K SF05KSS, SF10KSS

Diesel Generating Set


TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

Transcription:

Electric Flow Boiler

EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler using the latest technology. The compact design of the boiler makes it ideal for heating applications where space is at a premium. The Slim Jim is traditionally installed by professional heating engineers in properties such as apartments, domestic dwellings, holiday homes and light commercial properties. The Slim Jim is a fully controllable electric flow boiler which is designed to maximise cupboard space. The boiler also has an easy-fit front cover for future maintenance purposes. The versatile outputs are 4, 7, 10, 12, and 14.4kW. It can be installed as an open vented system or a conventional sealed system comprising of circulating pump and sealed system kit. A typical heating installation would comprise of the Slim Jim Boiler complete with standard wet system radiators, thermostatic valves, programmer and room thermostat. The boiler temperature range can be set between 30 degrees and 80 degrees centigrade which also makes it a suitable choice for underfloor heating applications. The Slim Jim has a user-friendly Front Control Panel incorporating heat mode and fault finding indicators, an on/off switch and easy-to-use temperature control setting. Safety is of paramount importance to EHC and as such our Slim Jim boiler has been designed to include a unique high current safety cut-out that protects the boiler from over-heating. The Slim Jim can be supplied as boiler only or complete with a choice of Heat Packs. Please contact our Sales Team 01698 820533 for further information.

Using the latest technology the Slim Jim Electric Flow Boiler offers the discerning buyer the flexibility and controllability of a modern electric wet central heating system. Easy to install Fully modulating boiler Compact in size: with 6 stage heating 912mm x 203mm x 172mm No mandatory boiler Outputs from 4kW servicing required up to 14.4kW Soft start approach to 100% Efficient avoid power surges No flue or fuel tanks required - can be located almost anywhere Silent in operation Maintenance free Exchanger Stainless Steel Heat Stainless Steel Heating Elements Can be used with standard radiators and thermostatic valves Adjustable control to set boiler temperature In-built fault finding diagnostics 2 years Parts & Labour guarantee

SlimJim Key Components Enclosure Heat Exchanger Insulation Flow: 22mm compression connection Stainless Steel Heat Exchanger Stainless Steel Elements Over Heat Cut-Out Entry Point for Power Return: 22mm compression connection PCB Volt Free Control Connections Entry Point for Controls

Typical System Design Sealed System-Heating only AAV Flow Auto Bypass Filling Loop PRV Pressure gauge Pump Return Expansion Vessel Magnetic Filter SlimJim Boilers in Parallel 22mm 28mm 35mm Flow 22mm 22mm 22mm Return 22mm 22mm 22mm Pump 35mm 28mm 22mm Drain Point NOTE: Expansion vessels and pressure relief valves are not shown on this schematic. All system designs should be in accordance with BS5449

In addition to supplying the Slim Jim Electric Flow Boiler, EHC also supply a variety of Stainless Steel Unvented Hot Water Cylinders. To complete your installation we can offer a selection of Heat Packs: Heating Only Sealed System Kit, Pump, Auto Air Vent, Magnetic Filter, Central Heating Programmer and Room Stat. Heating & Hot Water Sealed System Kit, Pump, Auto Air Vent, Magnetic Filter, Central Heating Programmer, Room Stat and Hot Water Programmer.

Heat Pack Components DHW Expansion Vessel Heating Expansion Vessel Auto Air Vent DHW Programmer DHW Control Valve Tundish Magnetic Filter Pump CH Programmer & Room Stat Direct Stainless Steel Slim Cylinder Options Capacity Height (mm Diameter (mm) Weight (kg empty) 120 Litre 1236 478 35 150 Litre 1424 478 40 180 Litre 1674 478 45

TECHNICAL SPECIFICATION Boiler range kw 4kW 7kW 10kW 12kW 14.4kW Pipe entry boiler - flow Pipe entry boiler - return top bottom Central heating flow & return pipes mm 22 Max pressure MPa 0.3 Min pressure MPa 0.05 Out flow water temperature ºC 30 _ 80 Max water temperature ºC 100 Overall dimensions (height x width x depth) mm 912 x 203 x 172 Weight Kg 11 Water connection mm 22 Safety class IP22 Electrical supply V AC 240V 1ph 50Hz Load current A 16.7 29.2 41.7 50.0 60.0 Recommended diameter of mains cable mm 6 10 16 16 16 Heat output (Btu/h) BTU/h 13648 23884 34120 40944 49161 Temperature setting (factory set) ºC 80 Min temperature setting ºC 30 Overheat protection ºC 100 Protection A 20 40 50 63 80 The Electric Heating Company Limited Tel: 01698 820533 Fax: 01698 825697 www.electric-heatingcompany.co.uk Email: info@electric-heatingcompany.co.uk