Humidity Sensor. Model HU-224/225



Similar documents
Duct Temperature Sensors

Pipe Temperature Sensors

HIH-4000 Series Humidity Sensors

Advantium 2 Plus Alarm

INSTALLATION / OWNERS MANUAL MODEL WB-200. PN # D-01 l-0007

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

Duct Humidity Transmitter

PRODUCT PROFILE FEATURES

TC-9102 Series Surface Mount Temperature Controllers

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Part I - Installation

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Centro-Matic Automatic Lubrication Systems System Controls

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

Model SRMD Setra Remote Monitoring Display

Machine Safety Switch: SI-LM40 Series Limit Switch Style

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

humidity sensors Line Guide FEATURES Honeywell HumidIcon Digital Humidity/Temperature Sensors HIH7000 Series, HIH8000 Series

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Industrial Ringdown/Autodialer Telephone SCR Series

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

el-720 Carbon Dioxide Gas Leak Detector User s Guide

User's Manual. Research Isometric Transducer 0 to 5 grams and 0 to 50 grams

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

User s Guide EWS-RH. Relative Humidity/Temperature Transmitter. Shop online at omega.com

Operating Manual UWAPS-TINY Series

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

INSTRUCTION MANUAL MODEL PCD-88

MS900AC-B-LS User Information

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

Water Leak Detection System

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Operation and Installation Manual

In-Situ Inc. Warranty / Terms & Conditions / Software License. This warranty policy applies to items that shipped prior to January 1, 2012.

CQM1-SF200/CS1W-SF200

Triple Expansion Chassis

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Single Station Remote Alarm

Original instructions Tina 3A/Aps Adaptor unit

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

Global Water Instrumentation, Inc.

ANI-64S-xRU. Single Section Wall Cabinet INSTRUCTION MANUAL

Wireless Indoor/ Outdoor Thermometer

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

Tina 2A/B Adaptor unit

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

RGC-IR Remote Gas Calibrator for IR400

TTL to RS232 Adapter User Guide

Dual Laser InfraRed (IR) Thermometer with Color Alert

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Safety Manual BT50(T) Safety relay / Expansion relay

FEMA ELECTRÓNICA. Serie ISC SIGNAL CONVERTERS WITH GALVANIC ISOLATION. MODEL ISC-IAC for AC Currents ISC-IDC for DC Currents USER S MANUAL

About Your NetBotz 4-20mA Sensor Pod

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

T7079A,B Solid State Remote Temperature Controllers

VALCOM HANDSFREE TALKBACK PAGING SYSTEM DESIGN/INFORMATION

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

Machine Safety Switches

High Temperature InfraRed Thermometer with Laser Pointer

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

MEDMASTER EXTERNAL POWER SUPPLY

Installation Instructions. Before Installation. Read these installation instructions carefully before commissioning the pressure transmitter.

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Dual Laser InfraRed (IR) Thermometer

How To Use A Cdm250 Digital Multimeter

700/732 SERIES. 5mm HOUR METERS & COUNTERS. CURTIS INSTRUMENTS, INC. 200 Kisco Avenue, Mt. Kisco, NY Tel. (914) FAX (914)

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

WORLD-BEAM QS30 Sensors

PagePac PAGEPAL V

Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications

Dual Laser InfraRed (IR) Thermometer

Old Company Name in Catalogs and Other Documents

Agilent 87421A/87422A Power Supply

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

MACTek Corporation. USB HART Interface. Users Manual

2-Way Wireless Indoor Siren Installation Guide

MFT Series INTRODUCTION UNPACKING FERRULES

Advanced Systems Tester 900AST

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Temperature Humidity Meter

Instructions A Amp AC/DC Current Probe

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Ground Resistance Clamp-On Tester

12 Volt 30 Amp Digital Solar Charge Controller

Transcription:

Humidity Sensor Model HU-224/225 RoHS Ultra fast response cross-linked bulk polymer capacitive sensing element Proprietary hydrophobic and oleophobic eptfe filter to protect the sensing element from condensation, fog, salt air, pollutants and other contaminants Rugged steel enclosure and thick-walled aluminum probe rated NEMA-4 (IP-65) to withstand weather extremes NIST traceable ±2% RH or ±3% RH calibration accuracy Two temperature compensated output versions, 4-20 ma 2-wire or field selectable 0-5 VDC/0-10 VDC Conforms to EMC and RoHS standards Two enclosure types: NEMA-4 (IP-65) duct mount or aesthetically appealing ABS plastic wall mount The HU-224/225 is an extremely fast, stable and accurate humidity transducer designed for harsh environments. The polymer capacitance sensor is protected with an eptfe (expanded Teflon) filter media. The Teflon protected cross-linked capacitive humidity sensor is not affected by prolonged exposure to condensing humidity, harsh environments, contaminants, fog or other extreme environmental conditions. Each unit is individually calibrated in an environmental test chamber to meet or exceed NIST traceable ±2% or ±3% accuracies. The HU-224/225 is temperature compensated for -30 F (-35 C) to +130 F (55 C) operation with negligible error. For space humidity, an aesthetically appealing ABS enclosure which may be flush mounted or fits a standard 2" x 4" handy box is available, and for duct humidity applications, a rugged NEMA-4 (IP-65) steel enclosure with external mounting bracket is also available. Two enclosure types, field selectable outputs, fully temperature compensated NIST traceable accuracy, non-interacting zero and span adjustments, short circuit and reverse polarity protected output, and a liberal five year warranty are some of the features which make the HU-224/225 the industry s highest performance, most reliable humidity sensor. 8189 Century Boulevard Minneapolis, MN 55317-8002 USA 800-843-5116 952-556-4900 Fax 952-556-4997 sales@mamacsys.com www.mamacsys.com 4200 Waterside Centre Solihull Parkway Birmingham West Midlands B37 7YN United Kingdom 01384-271113 Fax 01384-271114 1 Fullerton Road #02-01 One Fullerton Singapore 049213 65-31581826 Fax 65-31581826 4 Armiger Court, Unit 2 Adelaide S.A. 5088 Australia 08-8395-4333 Fax 08-8395-4433 675 Cochrane Drive East Tower 6th Floor Toronto Ontario L3R 0B8 Canada 905-474-9215 Fax 905-474-0876

The HU-224/225 incorporates a cross-linked bulk polymer capacitive humidity sensor which is immune to most contaminants and at the same time provides a stable, repeatable, accurate humidity measurement with negligible hysteresis. The sensing element is not affected by condensation. In fact, the probe may be immersed in distilled water without degrading the calibration accuracy. The HU- 224/225 utilizes sophisticated integrated circuits to provide a high level, fully conditioned, and temperature compensated humidity output. On VDC output units two additional field selectable options are available; dual outputs 0-5 or 0-10 VDC, and dual unregulated supply voltages 12-35 VAC or 12-40 VDC. By merely moving a switch, one can select the desired output for the specific application. As far as supply voltage is concerned, the unit automatically configures for AC or DC and no field selection is necessary. Another feature is that the output is fully protected from short circuit to ground, or if the supply voltage is applied by mistake to the output. Past experience demonstrates that field related wiring problems do occur. Instead of denying this fact, this protection circuit is designed in to ensure trouble-free start-up.the VDC output unit is also designed to handle low impedance circuits. In fact, the unit can drive up to 1K ohm minimum. In this way, multiple controllers, indicators, or other devices can be paralleled to the output without performance degradation. The ma output units function over a wide unregulated supply voltage range: 12-40 VDC without any effect on calibration or performance. The unit has reverse polarity protection built in. As a result, it is next to impossible to damage the unit by wiring incorrectly. By using sophisticated low dropout voltage regulators and CMOS integrated circuits, the ma output unit can drive very high output impedance. In fact, with only 12 VDC supply, the unit can drive 250 ohms. At 40 VDC, the unit is capable of handling up to a 1500 ohm load. In this way, the output loop can be tied in series to multiple controllers, indicators, and other devices without degrading the performance. The humidity sensor is protected by an eptfe (expanded Teflon) filter media that incorporates a proprietary process of expanding or stretching an ultra thin Teflon sheet during the manufacturing process to create less than 1.0 micron (0.000039 inch) pores or holes. The hydrophobic and oleophobic characteristics of Teflon force moisture, condensation and other contaminants to form a bubble larger than the pore size, and the surface tension of the Teflon stops the water or other contaminants from passing through the filter media, thereby protecting the sensing element. However, air with absorbed moisture can easily penetrate the filter media. NIST traceable humidity standards are utilized to calibrate and certify the HU-224/225. Calibration data on each unit is archived digitally for SPC and QC purposes. All automated calibration systems are networked and data is available online to numerous individuals at the same time. In this way, extremely high standards of quality and calibration integrity are maintained. The HU-224/225 incoporates a rugged NEMA 4 (IP-65) fully gasketed, dust proof and splash proof enclosure for monitoring duct humidity or an aesthetically appealing ABS plastic wall mount enclosure for monitoring space humidity. The HU-224 duct enclosure has an external mounting bracket to facilitate field installation. A ½" (.875"/22.25 mm diameter) knock-out for conduit connection is also provided. A liquid tight cable connector is supplied if the unit is not being hard wired. The HU-225 wall mount enclosure may be flush mounted on any flat surface or fits a standard 2" x 4" handy box. Louvers are provided on the top and bottom of the enclosure to ensure ample air flow for fast response. Both enclosure options also have additional features for ease of installation including unpluggable terminal block, easily accessible zero and span trimmers, and conveniently located switches for field selection. 2

HUMIDITY TRANSDUCER SPECIFICATIONS: Accuracy*: ±2% / ±3% RH Range: 0-100% RH Hysteresis: ±1% Supply Voltage: 12-40 VDC 12-35 VAC (VDC output units only) Supply Current: VDC Units - 10 ma max. ma Units - 20 ma max. Compensated Temp Range: -30 F to 130 F (-35 C to 55 C) Load Impedance: 1.5K ohms max. at 40 VDC (ma output units) 1K ohms min. (VDC output units) * Includes non-linearity and non-repeatability GENERAL SPECIFICATIONS: Environmental: 10-90% RH Non-Condensing Enclosure: 18 Ga C. R. Steel NEMA 4 (IP-65) or ABS Plastic Finish: Baked on enamel-pms2gr88b or off-white Termination: Unpluggable screw terminal block Wire Size: 12 Ga max. Weight: Duct mount - 1.0 lbs. (.45 kg) Wall mount - 0.5 lbs. (.25 kg) CONFORMANCE & TESTING: RoHS Compliant EMC Testing: BS EN 55022:1998, BS EN 55024:1998, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 ORDERING INFORMATION: HU- Packaging Accuracy Output 224 (duct mount) ±2% ma (4-20 ma 2-wire) 225 (wall mount) ±3% VDC (0-5 VDC or 0-10 VDC field selectable) Example: HU-224-2-mA : Duct Humidity Transducer, ±2% RH accuracy with 4-20 ma output. CAUTION: Do not use in explosive/hazardous environment or with flammable/combustible media. 3

Wall Mount 1.00" (25.40) 1.375" (34.92) 2.75" (69.85) 4.50" (114.31) 1.375" (34.92) 0.625" (15.87) 3.25" (82.55) 0.625" (15.87) Duct Mount 6.00" (152.40) 2.25" (57.15) 2.68" (67.51) 3.25" (82.55) 4.00" (101.60) 4.50" (114.31) 2.50" (63.51) 2.50" (63.51) (mm) 4

HU-224/255 MAMAC Systems is the leading global manufacturer of sensors, transducers, control peripherals and web browser based IP appliances. MAMAC products are used for HVAC and environmental controls, remote monitoring, alarming, energy metering and industrial automation. All MAMAC products are manufactured in the USA. WARRANTY: MAMAC Systems, Inc. and its subsidiaries (hereinafter referred to as MAMAC Systems) warrants its products to be free of defects in material and workmanship for a period of five (5) years from date of shipment. If a unit is malfunctioning, it must be returned to the factory for evaluation. A return authorization number (RMA) will be issued by the customer service department and this number must be written or prominently displayed on the shipping boxes and all related documents. The defective part should be shipped freight pre-paid to the factory. Upon examination by MAMAC Systems, if the unit is found to be defective, it will be repaired or replaced at no charge to the customer. However, this warranty is void if the unit shows evidence of being tampered with, damaged during installation, misapplied, misused, or used in any other operating condition outside of the unit s published specifications. MAMAC Systems makes no other warranties or representations of any kind whatsoever, expressed or implied, except that of title. All implied warranties including any warranty of merchantability and fitness for a particular purpose are hereby disclaimed. User is responsible to determine suitability for intended use. LIMITATIONS OF LIABILITY: The remedies of buyer set forth herein are exclusive and the total liability of MAMAC Systems with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the product upon which liability is based. In no event shall MAMAC Systems be liable for consequential, incidental or special damages. MAMAC Systems reserves the right to change any specifications without notice to improve performance, reliability, or function of our products. Every precaution for accuracy has been taken in the preparation of this manual, however, MAMAC Systems neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages that result from the use of the product in accordance with the information contained in the manual. 8189 Century Boulevard Minneapolis, MN 55317-8002 USA 800-843-5116 952-556-4900 Fax 952-556-4997 sales@mamacsys.com www.mamacsys.com 4200 Waterside Centre Solihull Parkway Birmingham West Midlands B37 7YN United Kingdom 01384-271113 Fax 01384-271114 1 Fullerton Road #02-01 One Fullerton Singapore 049213 65-31581826 Fax 65-31581826 4 Armiger Court, Unit 2 Adelaide S.A. 5088 Australia 08-8395-4333 Fax 08-8395-4433 675 Cochrane Drive East Tower 6th Floor Toronto Ontario L3R 0B8 Canada 905-474-9215 Fax 905-474-0876