Ductless Spray Booth Series



Similar documents
SENTRY AIR SYSTEMS, INC. PHARMACEUTICAL COMPOUNDING CONTAINMENT SYSTEMS SIMPLE SOLUTIONS FOR CLEANER AIR

Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace

Controlling health risks from rosin (colophony)-based solder flux fume

Laminar Flow Cabinets

A SELF-EVALUATION CHECKLIST of BEST PRACTICES for AUTO REFINISH SHOPS and SCHOOLS

Fume Hood Questions and Answers

IEQ Management Plan. Denver Museum of Nature and Science ECF Addition

Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material

Lead Exposure Management Plan

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

Camfil. Technical Services Bulletin Tools for Schools Filtration for Improved Indoor Air Quality

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

Stainless Steel Worksurface 3 Feet Hood A10-WS-PR3 A10-WS-SR3 4 Feet Hood A10-WS-PR4 A10-WS-SR4 6 Feet Hood A10-WS-PR6 A10-WS-SR6.

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

Laminar Flow Cabinets and Workstations

If you regularly wear a respirator on the job, OSHA requires your employer to provide:

Best Practices for Handling Nanomaterials in Laboratories

CHAPTER 4 VENTILATION

3M Purification Inc. 3M Air Management Products for Your Commercial HVAC Needs. Create. Air. Confidence

indoor Air quality products Air Filtration Ventilation Purification Humidification

Effectiveness of Engineering controls (LEVs)

SECTION HVAC AIR-DISTRIBUTION SYSTEM CLEANING

Fume Cupboard Guidance

Questions & Answers (Q & A) Regarding Asbestos Treatment with the Fire Suppression and Renovation Project

Effective Spray Painting Booth/Room Provided by Harleysville s Risk Control Department ext

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

Today, healthcare facilities must be prepared to face

Air Handlers HIGHER PERFORMANCE FOR A HIGHER STANDARD OF COMFORT AND EFFICIENCY. Read Only

HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

TURN-KEY LAB SPACE AVAILABLE

OSHA and Welding Exhaust

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

LAMINAR AIRFLOW EQUIPMENT CLASS I BIOLOGICAL SAFETY CABINETS BIOLOGICAL ENCLOSURES

Owner's Manual Air-Purifier MK-B1000 Air Cleaning Expert 110V Model

University of Tennessee Safety Program

HEALTHY CLIMATE HEPA BYPASS AIR FILTRATION SYSTEM READ AND SAVE THESE INSTRUCTIONS! AIR CLEANERS/ FILTERS

presents Cooking With Fire Fixed Fire Suppression & Exhaust Systems for Cooking Environments Monday, 17 June, 13

Risk Assessment: Biosafety Cabinet

CONSTRUCTION IAQ MANAGEMENT PLAN During Construction

Downflo workstation DuSt ColleCtorS

There are several types of air cleaning devices available, each designed to remove certain types of pollutants.

In addition, flammable solvents and thinners are often mixed with the above substances.

Trane CleanEffects. Patented technology. Superior performance. READ ONLY

Radford University. Indoor Air Quality Management Plan

CONTINUOUS FLOW BREATHING AIR PURIFIERS

Lab PPE Guide Examples of Personal Protective Equipment

Clearing the air A simple guide to buying and using local exhaust ventilation (LEV)

SPECIAL APPLICATIONS

3M Personal Safety Division 3M Center, Building W-75 St. Paul, MN, USA

A Report of Air Sampling for Mercury Vapor and Particulates During Fluorescent Tubes Disposal Operation Maywood, Illinois Survey date: 9/28/2000

DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS

What to Know When Considering a Cleanroom. by Simplex Technical Staff

Building and Grounds Maintenance Checklist

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Kompressoren. Adsorption Dryer AD

Spray Booth Guideline

Department of Environmental Health and Safety & Emergency Management

Chemical Fume Hoods. Environmental Health and Safety

Air Conditioners A COOL, COMFORTABLE SOLUTION TO TAKE YOU TO A HIGHER STANDARD OF COMFORT. READ ONLY

Atlas Copco Quality Air Solutions. Compressed Air Filters

IEQ-15 Air Distribution System

Module 5: Objectives And Targets

LABORATORY BUILDING DESIGN UPDATE

3.8 HSP (High Solids Polyurethane)

NFPA Combustible Dust Compliance and the Industrial Ventilation System

Indoor Air Quality Issues for Hotels

Laboratory Ventilation Safety. J. Scott Ward

Make your home a healthier home

Air Conditioners. A cool, comfortable solution to take you to a higher standard of comfort. READ ONLY

Improving Indoor Air Quality on a Tight Budget

Camfil Farr Technical Services Bulletin

UniMax Large Floor Mount (Walk-In) Fume Hoods

Fire - Smoke - Soda Blasting

Procedures for the Effective Use of Biological Safety Cabinets

PI s Name Date Bldg./Rm# CDC Biosafety Level 3 (BSL-3)

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

Wildfire Smoke and Your Health

Laboratory Design & Construction Guidelines

RULE FURTHER CONTROL OF VOC EMISSIONS FROM HIGH- EMITTING SPRAY BOOTH FACILITIES

1. Certification: Employ an ASCS certified by NADCA on a full-time basis. 2. Supervisor Qualifications: Certified as an ASCS by NADCA.

Guidelines for Mold Remediation (Removal)

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

ASALAIR BIOHAZARD CABINET MODEL ATLANTIC CYTOCABINET 1200 CLASS II TYPE A2 COD MICROBIOLOGICAL SAFETY CABINET CLASS II TYPE A2

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

Federation of European Heating, Ventilation and Air-conditioning Associations

Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP

INDOOR AIR QUALITY POST-OCCUPANCY ASSESSMENT. Massachusetts Department of Revenue 100 TradeCenter, Suite 760 Woburn, MA

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Environmental Monitoring

34% 81% 84% 19% GOLD PROJECT HIGHLIGHTS. LEED Facts. Stubbs Laboratory

Range Equipment HVAC Design & Supply Modular Ranges

Trane XB Series. A reputation for reliability and smart, sensible comfort.

How to Choose An Air Filter For Your Boat

Sun-Pure Air Purifier

Transcription:

Sentry Air Systems, Inc. Ductless Spray Booth Series A Respiratory Safety Engineering Control: Ductless Benchtop Hooded Enclosures for the extraction and purification of aerosol spray paint fumes & particulate. Features: Triple Stage Filtration: Pre-Filter, HEPA Filter & Activated Carbon Filter. Hoods are Available in a Variety of Standard Sizes. Custom Options and Accessories Available. Recirculating Air Pattern: Respiratory Safety without the Cost of External Ducting. Perfect for environments that cannot vent outside. Made in the U.S.A. Typical Uses: Production & Manufacturing Electronics: Conformal Coating Research & Prototyping Graphic Design Architectural Firms Art Schools & Universities 1.800.799.4609

Ductless Spray Booth Series Sentry Air Systems Ductless Spray Booths are built with stringent quality control measures and superior craftsmanship. If your application requires a benchtop hooded enclosure for aerosol spray control, Sentry Air Ductless Spray Hoods may be an excellent choice. These negative-pressure systems utilize powerful fans and high-quality pre-filters, HEPA filters, and Activated Carbon filters. This combination helps to protect the operator s respiratory zone and prevents unwanted spray particulate and odors from entering the general work area. Sentry Air Systems Portable Spray Booths are extremely energy efficient and do not require costly external ducting. They are an optimal fume control solution for environments that do not have to access to or are not permitted to exhaust aerosol particulate and fumes outdoors. Typical portable spray hood uses may include light spray painting, conformal coating, aerosol sprays, epoxy overspray, and a variety of other processes that expel aerosol particles and fumes. FILTERED AIR AEROSOL PARTICLES AND FUME Testimonials: "I purchased my Sentry Air Systems spray hood to control the fumes and particulates when spray painting custom radio controlled aircraft canopies. I use heavy duty automotive paint and solvents and the hood significantly reduces the odors and air borne particles. It is quiet and efficient and my clients can watch me in action in my paint studio thanks to this great air filtration system!" David Humphreys [30 Wide Ductless Spray Booth] STEP FOUR: THE FINAL [OPTIONAL] STAGE OF IS AN ACTIVATED CARBON FILTER. THIS FILTER REMOVES VOC S ANDODORS REMAINING IN THE AIRSTREAM. THE FILTERED AIR IS RECYCLED BACK INTO THE ROOM. STEP THREE: SPRAY PARTICLES AND AEROSOLS THAT WEREN T REMOVED BY THE PRE-FILTER ARE CAPTURED IN THE 2ND FILTER STAGE A HEPA [UP TO 99.97% EFFICIENT ON PARTICLES 0.3 MICRONS AND LARGER] OR ASHRAE FILTER [UP TO 95% EFFICIENT ON PARTICLES 0.5 MICRONS AND LARGER]. STEP TWO: THE CONTAMINATED AIR IS CARRIED THROUGH THE INTERNAL SPRAY PRE-FILTER RACK INSIDE THE HOOD. LARGER OVERSPRAY PARTICLES ARE CAPTURED HERE. STEP ONE: OPERATOR PERFORMS APPLICATION WITHIN THE HOOD, GENERATING OVERSPRAY, WHICH IS PULLED UPWARD BY THE FAN. It works exactly as advertised and has been a tremendous asset to our productivity. Assembly was simple with the CD and the fit and finish is very nice. When we needed to make a couple of modifications to meet our needs, the staff at Sentry was helpful and timely in making it happen. I highly recommend Sentry Air Systems and their products. Keith Wicklund Hardcoat Incorporated [50 Wide Ductless Spray Booth] 1.800.799.4609

Ductless Spray Booths: Standard Sizes Ductless Spray Hoods are available in a variety of standard sizes. Sentry Air Systems engineers also design and manufacture Custom Hoods when requested. PAGE 4 Standard Sizes: 40 Wide Outer Dimensions: 24" D x 42 W x 32" H Interior Dimensions.: 23.5" D x 40" W x 24" H Model # SS-340-DSH 50 Wide Model # SS-350-DSH Outer Dimensions: 24" D x 52 W x 32" H Interior Dimensions.: 23.5" D x 50" W x 24" H Model Numbers: 30 Wide Model # SS-330-DSH Outer Dimensions: 24" D x 32 W x 32" H Interior Dimensions.: 23.5" D x 30" W x 24" H 60 Wide Model # SS-360-DSH Outer Dimensions: 24" D x 62 W x 32" H Interior Dimensions.: 23.5" D x 60" W x 24" H 1.800.799.4609

Ductless Spray Booth - 30 Wide Model # SS-330-DSH HOOD Outer Dimensions: 24" D x 32 W x 32" H Interior Dimensions.: 23.5" D x 30" W x 24" H Approx. 110 lbs. Portable and Lightweight Other Standard Sizes: 40, 50, 60 32 The 30 Wide Ductless Spray Booth is a hooded enclosure specifically designed for the control of aerosol spray. This system is a negative-pressure benchtop enclosure that captures and filters aerosol particles produced by a variety of applications, including light spray painting, aerosol sprays, epoxy overspray, touch-up painting, conformal coating fumes, and a variety of other processes that release aerosol particulate and odor. This benchtop hood utilizes a unique internal spray filter, HEPA filtration, and Activated Carbon filtration to contain hazardous particulate and unwanted odor. It is also ductless and does not require any external venting, which makes it an optimal solution for indoor environments where external venting is not practical or desired. The 30 Wide Ductless Spray Booth features energy-efficiency and quiet and low maintenance operation. Customized Spray Booths are also available for customers with specific application requirements.

Ductless Spray Booth - 40 Wide Model # SS-340-DSH HOOD Outer Dimensions: 24" D x 42 W x 32" H Interior Dimensions.: 23.5" D x 40" W x 24" H Approx. 125 lbs. OR Portable and Lightweight Other Standard Sizes: 30, 50, 60 42 30 Wide Ductless Spray Booth Pictured Above The 40 Wide Ductless Spray Booth provides a negative-pressure hooded enclosure for the control of aerosol spray. These energy-efficient systems utilize powerful fans and a variety of high-quality filtration media to provide effective source-capture of airborne contaminants and fumes. A unique internal spray filter, HEPA filtration, and Activated Carbon media help to protect the operator s respiratory zone while also preventing unwanted spray particulate and odors from entering the general work area. The ductless and recirculating design of this benchtop hood eliminates the need for external ducting or costly replacement air. Ductless Spray Hoods are typically used for light spray painting, aerosol sprays, epoxy overspray, touch-up painting, conformal coating fumes, and a variety of other processes that release aerosol particulate and odor. In addition to our Standard Portable Spray Booths, we offer Custom Spray Booths built for those customers with specific application requirements.

Ductless Spray Booth - 50 Wide Model # SS-350-DSH HOOD Outer Dimensions: 24" D x 52 W x 32" H Interior Dimensions.: 23.5" D x 50" W x 24" H Approx. 135 lbs. OR Portable and Lightweight Other Standard Sizes: 30, 40, 60 52 60 Wide Ductless Spray Booth Pictured Above The 50 Wide Ductless Spray Booth helps to protect the operator s breathing zone and general working environment from hazardous aerosol spray. This system is a negative-pressure enclosure that utilizes a powerful fan and triple-stage filtration system. A unique internal spray filter, HEPA filter, and Activated Carbon are used in combination to remove airborne particulate and unwanted odors. This system is ductless and does not require any external venting, which makes it an optimal solution for indoor environments where external venting is not practical or desired. Typical applications include light spray painting, aerosol sprays, epoxy overspray, touch-up painting, conformal coating fumes, and a variety of other processes that release aerosol particulate and odor. The 50 Wide Ductless Spray Booth is a reliable, energy-efficient, and economical solution for applications that require the control and removal of aerosol spray and odors. In addition to our Standard Portable Spray Booths, we offer Custom Spray Booths for customers with specific application requirements.

Ductless Spray Booth - 60 Wide Model # SS-360-DSH HOOD Outer Dimensions: 24" D x 62 W x 32" H Interior Dimensions.: 23.5" D x 60" W x 24" H Approx. 150 lbs. OR No External Venting Required Other Standard Sizes: 30, 40, 50 62 The 60 Wide Ductless Spray Booth is a highly efficient engineering control for a variety of applications that emit hazardous overspray particulate and fumes. This system is designed to help protect the operator s respiratory zone during processes such as aerosol spraying, spray painting, touch-up painting, air brushing, epoxy overspray, conformal coating fumes, and a variety of other operations that produce unwanted or hazardous overspray. This spacious 60 wide negative-pressure enclosure is equipped with a powerful fan and triple-stage filtration system consisting of a unique internal spray filter, HEPA Filter [up to 99.97% efficient on particles 0.3 microns and larger], and Activated Carbon Filter. This combination of filter media is capable of removing the fine respirable particles in addition to the chemical fumes found in the sprays. Ductless spray hoods can be very useful for indoor operations where it is difficult or not possible to vent outside because of the building s structure or in an environment where external venting is prohibited by government or state regulations. The high-quality filtration media used in this system allows for a recirculating air pattern, so external ducting is not required. The 60 Ductless Spray Booth offers sturdy construction, energy-efficiency, and low maintenance operation. A transparent version and other custom options are available.