Ammeter / Voltmeter Series 8402, 8403, 8405, 8404



Similar documents
Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices CES 63 A Series 8579

Series 8146/5-V37 and Series 8150/5-V37

Control and Distribution Boxes made of Stainless Steel Series 8150

Terminal Boxes Series 8146

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire with LED Series EXLUX 6402/2

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Flameproof Audible Signal 115 db (A) Series YA90

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

2.12. page Products for Explosion hazardous Environment

9 Control Equipment. Control Button Series 8082

7 Lighting Technology

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Control Stations Made of Polyester Resin Series 8146

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Solenoid Valve Island Type 3965

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

A good connection. International approvals.

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

8146/5 Series Breaker Panelboards

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Vario-Series Accessories

Technical Data. Dimensions

Technical Data. Dimensions

STB Series Enclosures

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Floodlight Range Installation Guide

Electro-pneumatic control valves

Power Supplies 3. SDN-P DIN Rail Series

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Safety technique. Emergency stop module BO 5988 safemaster

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Redundancy Module QUINT-DIODE/40

Actuator-Sensor-Interface

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Microcor Wireless Transmitter (MWT)

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Flow switches Series AD/VH

1756 ControlLogix Chassis Specifications

SINEAX U553 Transducer for AC Voltage

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Thermometer in stainless steel with capillary and switch contacts

Inductive sensor NI10-M18-Y1X-H1141

Pluggable interface relays CR-P Pcb relays

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

MINI MCR-SL-R-UI(-SP)

FGM 160 ATEX EC type examination certificate

Digital inductive conductivity transmitter

Assisted lift operated 2/2-way solenoid valves Type EV250B

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

J TB/TW Temperature limiter, temperature monitor

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

48 SERIES Relay interface modules 10 A

Technical Information RIA14

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

5SV Residual Current Protective Devices

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

RY2 miniature industrial relays

S-series Mass Connection Solutions

TTF300 Field-mount temperature transmitter

TEIP11 I/P signal converter for standard signals. Measurement made easy

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

3753 en /b VE/B - VE/RG Va V riable speed drives

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM4TG20 three-phase network control relay RM4-T - range V

Differential-Hall-Effect based Sensors Series A5S Overview

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Circuit Breakers. NRC Series. NRC Series

ConSig 8040 Series CONTROLS Features:

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

SERIES SINGLE POLE AND DOUBLE POLE ROCKER SWITCHES UP TO 12 (4) A 250 V~ AND 8 (8) A 250 V~

UM-X Field display for continous level sensors

Terminal Box. Specifications TNCN

POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Scraper Passage Indicator. Electrical Indicator. Features

Transcription:

/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected, electrical components with a moving iron instrument of the accuracy class 2.5. Integrated in enclosures with the type of protection "Ex e", they are used to measure and indicate current and voltage values. The externally adjustable red pointer of the device allows a rapid measurement comparison. The current transformer (CT) versions (1 A and 5 A) allow a rapid and easy measurement range assignment on site due to the scale plate which can be slid in from the side. ATEX / IECEx Class I (NEC 505) (NEC 506) Class I Class II Class III Zone 0 1 2 20 21 22 0 1 2 20 21 22 Division 1 2 1 2 1 2 8402, 8403, 8404: For use in 8405: For use in x x 8403, 8404: Einsetzbar in x x x 8405: Einsetzbar in x WebCode 8402A Control Devices /1

/, 8403, 8405, 8404 Selection Table Description Overload scale Measuring range Order number Weight without 1... 20 ma resp. 4... 20 ma; for connection to certified intrinsically circuits only kg 8402/5 0.222 for Ex i circuits,,, 64 x 64 mm, 02414E00 01841E00 01842E00 01843E00 with scale for CT with scale 2 times 0... 20 / 40 ma 8403/2-0,02/0,04-. 0.218 4... 20 / 40 ma 8403/2-0,02/0,04-. 0.220 2 times 4... 20 / 40 ma 8403/2-100%/200% 0.218 0... 1 / 2 A 8403/2-1/2 0.216 0... 4 / 8 A 8403/2-4/8 0.222 0... 10 / 20 A 8403/2-10/20 0.222 0... 15 / 30 A 8403/2-15/30 0.222 0... 25 / 50 A 8403/2-25/50 0.264 2 or 5 times sek. 1 A 8403/2-1 0.216 sek. 5 A 8403/2-5 0.216 2 times 0... 20 / 40 ma 8405/3-0,02/0,04-. 0.122 0... 1 / 2 A 8405/3-1/2 0.124 0... 4 / 8 A 8405/3-4/8 0.118 0... 10 / 20 A 8405/3-10/20 0.120 0... 15 / 30 A 8405/3-15/30 0.120 2 or 5 times 1 A 8405/3-1 0.125 5 A 8405/3-5 0.125 without 0... 10 V 8404/2-10 0.216 0... 100 V 8404/2-100 0.216 0... 150 V 8404/2-150 0.216 0... 250 V 8404/2-250 0.274 0... 500 V 8404/2-500 0.216 Bezel á 64 mm (for ammeter ) Bezel á 72 mm (for ammeter and voltmeter ) 155940 0.500 155942 0.025 Bezel Note 01845E00 * Please order scales separately. Further measuring ranges or scales on request. /2 Control Devices

/, 8403, 8405, 8404 Explosion Protection Marking Ex i IECEx Ex ib IIC T6 Ex e II/I, Ex em II/I Ex e II/I, Ex em II/I Ex e II/I, Ex em II/I Europe (ATEX) E II 2 G Ex ib IIC T6 E II 2 G Ex e II E II 2 G Ex e II E II 2 G Ex e II Certificates Ex i IECEx IECEx PTB 06.0006 IECEx PTB 06.0017 U IECEx PTB 06.0017 U IECEx PTB 06.0017 U Europe (ATEX) PTB 98 ATEX 2101 PTB 01 ATEX 2158 U PTB 01 ATEX 2158 U PTB 01 ATEX 2158 U Other certificates Canada (CSA), Russia (CTB), Canada (UL, CSA), USA (UL, FM), Technical Data Electrical data Ex i Isolating voltage 690 V 690 V 690 V Type of current AC 15... 100 Hz, DC AC 15... 100 Hz, DC Power input max. 0.43 W max. 0.43 W max. 2,1 VA Max. short circuit current max. 150 ma Internal resistance ~ 2.93 O Internal inductance 68.5 mh Internal capacitance ~ 0 Ambient conditions Ambient temperature - 20... + 40 C AC 15... 100 Hz, DC Mechanical data Ex i Enclosure material Polyamide - polyester Polyamide - polyester Polyamide - polyester Polyamide - polyester Connection cross-section finely-stranded 2.5 mm 2 2.5 mm 2 2.5 mm 2 solid 4.0 mm 2 4.0 mm 2 4.0 mm 2 Mounting / Installation Mounting on TS35 rail Movement Ex i Movement Moving coil instrument Moving iron Moving iron Moving iron Accuracy Class 1.5 Class 2.5 Class 2.5 Class 2.5 Scale 0-100 linear,, Length 40 mm Overload capacity 2 x I N 25 sec 50 x I N 1 sec Related to the measuring range end value 2 x I N 25 sec 50 x I N 1 sec Related to the measuring range end value 1,2 times continuous 2 times 60 sec Bezel Ex i Material Glass - polyester Glass - polyester Glass - polyester Glass - polyester Degree of protection IP66 IP66 IP66 IP66 Gaskets Neoprene Neoprene Neoprene Neoprene Impact strength ) 7 J ) 7 J ) 7 J ) 7 J Sizes á 72 mm á 72 mm á 64 mm á 72 mm Control Devices /3

/, 8403, 8405, 8404 Accessories and Spare Parts Designation Illustration Description Order number Weight Push-in scales for the 8405 series and the 8403 series 05062E00 For the 8405 series and the 8403 series Measuring range - double overload 0 A... 1 A 5 A 10 A 15 A 20 A 25 A 30 A 40 A 50 A 60 A 75 A 100 A 150 A 200 A 300 A 500 A Specify measuring range kg Assembly accessories For the 8405 series and the 8403 series Measuring range - quintuple overload 0 A... 1 A 5 A 10 A 15 A 20 A 25 A 30 A 40 A 50 A 60 A 75 A 100 A 150 A 200 A 250 A 300 A 500 A For 8405 series To engage on TS 35 mounting rail Specify measuring range 130954 0.022 05615E00 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 53 A 48 57 48 Bezel assembly code 740 for ammeter 04071E00 04087E00 04490E00 Slide -in scale for ammeter with CT /4 Control Devices

/, 8403, 8405, 8404 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Bezel assembly code 145 for ammeter and voltmeter 04576E00 03348E00 04492E00 Slide-in scale for ammeter with CT 04593E00 We reserve the right to make alterations to the technical data, weights, dimensions, designs and products available without notice.the illustrations cannot be considered binding. Control Devices /5