Meaco 10L Basic Small Home Dehumidifier



Similar documents
Meaco 30L and Meaco 40L dehumidifier instruction manual

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Meaco DD8L desiccant dehumidifier Instruction Manual

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Dehumidifier Users manual. For Models: DH45S DH65S

Instruction manual for Firstline FCS12000CH

Use and Care Manual. Model CPA12KH AIR CONDITIONER

INFRARED QUARTZ WALL HEATER

Important Safeguards

VACUUM CLEANER INSTRUCTION MANUAL

- 2 - IMPORTANT SAFETY REMINDERS

Please read and keep these instructions. Run water through your machine before first use

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Operating Instructions Air Conditioner

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

2-SLICE COOL TOUCH TOASTER

USER S MANUAL HSC-24A

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Room Air Conditioners

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

3 WATT LED SPOTLIGHT Model No. SLM

PORTABLE AIR CONDITIONER

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

100 Series Maxi Internal Filters. Instruction Manual

Operating instructions in the back. PD1020L

Contact Details. Please note that some of the contact details on this PDF document may not be current.

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL


Portable Air Conditioner INSTRUCTION MANUAL

Operating Instructions Split System Air Conditioner

PORTABLE AIR CONDITIONER

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) (ROI) White series

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

IMPORTANT SAFETY RULES TO FOLLOW

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Hot Water Urns. all models. Helpline. v3.0

ADVANCED CERAMIC. with REAL PEARL HEAT 8x smoother 5x longer lasting AC REM IFU Ci76_22L.indd 1 19:47:

PG_IM_A.indd 1 23/06/ :22

Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase

12 cup programmable coffee maker

WHYNTER 21 Bottle Dual Temperature Zone Freestanding Wine Cooler

Get Me Cool Now Portable Air Conditioner User s Manual

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

PORTABLE AIR CONDITIONER (LOCAL)

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Multifunction. vax.co.uk Series. What s your Vax model number?

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

ClearView 100. Instruction Manual

Split Type Room Air Conditioner. KSWM units

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

ELECTRIC INSTANTANEOUS WATER HEATER

MIST DECORATIVE LAMP WITH ESSENTIAL OIL DIFFUSER

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Safety, Operation and Maintenance Manual with Parts List

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

Instruction Manual. Window Wiper AFW900. (Read carefully before use)

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Instruction Manual. AWK-115S

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER

OPERATING MANUAL ASSEMBLY. Remote control docks magnetically. click. until it clicks and locks. REGISTER YOUR FREE 2 YEAR GUARANTEE TODAY

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER

Operating Instructions Air Conditioner

the Soft Top Breville Customer Service Center Instruction Book - Livret d instructions

INSTRUCTION MANUAL REFRIGERATOR BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Troubleshooting Your Refrigerator

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

Portable Evaporative Air Cooler with Heater for indoor use. OWNER S MANUAL Read and save these instructions before use.

EP ; WO2012/080751; GB

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

Wine Cooler with Thermo-Electric Cooling & Heating Technology

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

Convection TCO600. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

Operating Instructions

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

Split Air Conditioner

HEAT RECOVERY VENTILATORS MODELS 90H-V ECM HRV, 90H-V+, 60H-V+ AND ENERGY RECOVERY VENTILATOR MODEL 90H-V ECM ERV

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

Owner s manual. Free 5 year parts, 1 year labour gurantee Register your guarantee at

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

OPERATING INSTRUCTIONS

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Operating Instructions

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Transcription:

Meaco 10L Basic Small Home Dehumidifier DEHUMIDIFIER OPERATING INSTRUCTIONS All the drawings in this manual may be different with the material objects, please refer to the material objects for reference.

BEFORE FIRST USE Read and follow all the instruction even if you feel you are familiar with the product, and find a place to keep it handy for future reference. For your convenience record the complete model number ( located on the product identification plate ) and the date you received the product, together with your purchase receipt and attach to the warranty and service information. NOTE: The rating of this product ( as marked on the product identification plate ) is based on specific loading tests. Normal use may draw significantly less power. Installation Instructions IMPORTANT INSTRUCTIONS Do not install and use your dehumidifier before completely reading these instruction. This will help you optimise the operation of your dehumidifier. The following advice and instructions should be followed closely: because it contains a cooling agent. upright position 2. After unpacking your unit, place the unit upright to allow the cooling agent to stabilise, and wait 2 hours before use. Failure to comply with these instructions may damage the unit and will invalidate the warranty. 3. This product must not be disposed together with the domestic waste. This product has to be disposed at an authorized place for recycling of electrical and 4. The appliance shall not be installed anywhere where water can drip directly onto the dehumidifier. 5. The appliance shall be installed in accordance with national wiring regulations and must be positioned so that the plug is accessible. 6. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. 1

When using any electrically powered dehumidifier, basic safety precaution should always be followed, including the following: PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE USING THE PRODUCT WARNINNG-to reduce the risk of fire, electrical shock or injury to persons or property : 1. Always operate the product from a power source of the same voltage, frequency and rating as indicated on the product identification plate. 2. Close supervision is necessary when any product is used by or near children or those with a physical impairment. Do not allow children to use it as a toy. 3. Do not operate any product with a damaged cord or plug, or after the product malfunctions, or is dropped or appears damaged in any way. Return the complete product to the place of purchase for inspection, repair or replacement. 4. Never connect the unit to a defective socket. 5. To avoid tripping the circuit, only use an extension lead after ensuring it is in perfect working order. 6. Make sure that the unit is correctly connected before turning on the unit's power. Never lay down the unit while it is working. 7. Always keep it in an upright position to avoid any damage to the unit. 8. Switch off and unplug from outlet when not in use or before cleaning. 9. To turn on your unit, always use the switch on the control panel. 10. Never unplug the dehumidifier while it is working, this could damage the electronic circuits. 11. Never place anything on top of the unit and do not cover it with any kind of cloth while it is plugged in or in-use. 12. Do not place objects on the product or allow objects to obstruct the inlet or outlet openings, or operate in close proximity to walls or curtains, etc. 13. The use of attachments or accessories not recommended or sold by the product distributor may cause personal or property hazards or injuries. 14. Keep the area around the warm air outlet sufficiently clean and make sure that it is not congested. 15. Allow at least 500mm (20 inches) of air space on all sides of the unit for good air ventilation. 16. Do not place the power cord under a carpet. 17. Never install the unit in direct sunshine. IMPORTANT SAFEGUARDS 18. Prevent children from climbing on the unit. 19. This product is intended for normal domestic / household use only. 20. Repairs should only be carried out by competent service department. 21. The operating temperature range is 5-35 O C. 22. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. PLEASE READ AND SAVE THESE INSTRUCTIONS 2

PRODUCT DESCRIPTION Air filter Handle Control Panel Air outlet Air inlet Power supply cord Tube stopper Bucket CONTROL PANEL Water full indication CON FULL OFF Operation indicator Defrost indicator RUNNING DEFROST Humidity control knob OFF CON Switch off. Dehumidifier continuously running. 3

PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS BS PLUG WIRING Wiring Instructions: Should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code : BLUE - NEUTRAL BROWN - LIVE GREEN AND YELLOW EARTH As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: 1. The BLUE wire is the NEUTRAL and must be connected to the terminal which is marked with the letter N or coloured BLACK. 2. The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED. 3. The GREEN/YELLOW is the EARTH and must be connected to the terminal which is marked with the letter E or or coloured GREEN OR GREEN/YELLOW. 4. Always ensure that the cord grip is positioned and fastened correctly. If a 5A (BS 1363) fused plug is used it must be fitted with a 5A fuse. If in doubt consult a qualified electrician. Wiring for a 5Amp Plug (BS1363) Please note. The Earth Terminal is marked with the letter E or Earth Symbol. Earth E (Green / Yellow) Neutral N (Blue) 5amp Fuse Live L (Brown) 4

Specification M odel MEACO10L Basic R ated V oltage 220-240V ~ R ated F r equency 50H z C apacity 0.4 k g/h ( I S O 5 151) P ower I nput 220W R ated I nput 250W H i. S ide P r essur e 1.7 M P a L ow S ide P r essur e 0.6 M P a R efr iger ant R 134a R efr i. C har ge 0.1 4k g W eight 10k g Warning: To reduce the risk of electric shock, always unplug this appliance from the electrical outlet immediately before cleaning or serving. If it is not working properly, contact a qualified electrician or service center for examination and repair. Never try to dismantle it by yourself. 5

OPERATING INSTRUCTIONS Start Operation the bucket full lamp illuminates when the unit is first switched on, remove the tank and replace it. FULL RUNNING or CONTINUOUS to work DEFROST While turning on ( or off ) the machine, the defrost lamp will shine. Full Bucket Lamp The lamp will illuminate when the water container is full. To empty the unit, first unplug from power source then carefully remove the tank and empty the collected water. Replace the bucket carefully before switching the unit on again. R emove the water in the water tank with two hands Defrost Lamp If the ambient temperature is too low the unit will automatically start to defrost and the light will illuminate. The defrost lamp will also illuminate if the air filter becomes clogged. This unit has 3-min lag due to the device for protecting circuit.in order to prolong the compressor's working life, the compressor will not start until the unit has run for 3 minutes. 6

CONTINUOUS DRAINAGE CONTINUOUS DRAINAGE permanent drainage. not su For drainage Back of the unit Tube stopper Soft cover the bucket for storage. Tube stopper PVC hose Correct Use When Drainage Hose Is Connected When using continuous drainage, the PVC hose must be placed below the drainage hole. Avoid uneven surfaces and do not 'kink' the hose. 7

MAINTENANCE Before clea from the outlet. EXTERIOR SURFACES OF THE UNIT AIR FILTERS Clean the dehumidifier by using a damp sponge, and dry it with a clean, soft cloth. Never use alcohol or any product containing solvents. Do not immerse unit in water. The air filters located inside the unit collect dust contained in the air. To keep the dust from clogging the unit, your unit must always be used with its air filters. The build up of dust reduces the efficiency of the dehumidifier. Therefore, the air filters must be cleaned every two weeks, and more often if the machine operates in a dusty atmosphere. If the filters are obstructed, the dehumidifier will be less efficient. To remove the filter, first tilt the dehumidifier backward, then pull the filter downward and forward until it is free of the body of the unit. Air ter Clean the filters with a vacuum cleaner. If the filters are very dirty, you can wash them in warm water(never use hot or soapy water). Make sure that the air filters are completely dry before putting then back on the unit. Do not bend the filters. 8

9 Condition Cause What to do The unit does not The "Running" lamp twinkles. Has the power supply cord been disconnected? Is the " Red " lamp blinking?(the tank is full or in a wrong position. Is the temperature of the room above36 C or below 3C. The tube temperature sensor has failed or is disconnected. Plug the power supply cord into the outlet. Discard the water in the drainage tank, and then reposition the tank. The protection device is actuated and the unit cannot be started because the room too cool or too hot (in that case, please do not use the dehumidifier). The sensor must be repaired or reassembled by competent service help you to save your time and cost. If a condition listed below occurs,please check the following items to Removing breakdowns MAINTENANCE

Is the air filter clogged? Clean the air filter as instructed under "Caring for the dehumidifier". function does not work. Is air intake port or discharge port obstructed? Remove whatever is obstructing the discharge port or intake port. 10 No air is discharged Operation is noisy Is the air filter clogged? Is the dehumidifier on an uneven surface? Clean the air filter instructed under "Caring for the dehumidifier". Use the unit on a level surface. Prompt: Put a cushion under the unit and help to reduce operation noise. MAINTENANCE Is the air filter clogged? Clean the air filter as instructed under "Caring for the dehumidifier". After the above condition has occurred and corresponding step is used but the breakdown can not be removed or other breakdown occurs, please contact the authorised service centers.

11 symptom The operation noise suddenly increases during use. The humidity does not drop Very little or no dehumidifying takes place, takes place. Reason The operation noise increases when the compressor is activated. Is the room too big for the unit? Are windows or doors opened and closed frequently? Is there a device in the room such as a kerosene stove, which emits steam? This happens if the temperature and/or humidity of the room is low. The following symptoms do not indicate a breakdown. Normal operation & not a fault MAINTENANCE When the unit is first used, the discharged air smells musty. Because the temperature of the head exchanger rises abruptly, an unusual or musty odor may be produced for

The unit echoes If the unit is used in a room with wood flooring or in a small room, it may echo. 12 When operation is started or the operation mode is changed, an unusual noise is heard in main unit. There are some stains left in the drainage tank. The fan is running and the compressor does not work. The refrigerant may take some sound until circulation stabilises. This is water left from the dehumidifying test conducted at the factory, it does not indicate a problem. If the unit is started within 3 minutes after the unit stopping, the protection device is actuated, so that the compressor only starts automatically after a delay of 3 minutes; or the automatic defrosting operation is activated and the compressor stops. MAINTENANCE

LONG TERM STORAGE At the end of the season. or when you do not plan to use the unit for an extended period of time, we recommend that you take the following steps. Remove water from the water bucket. If continuous drainage hose is connected, disconnect it. Disconnect the unit and wrap the power cord and plug. Clean the unit and store it, protecting it from dust. Store the unit in an upright position. Keep it in a cool, dry place and away from sunshine. 13

CUSTOMER SERVICE Thank you for choosing Meaco, we really appreciate it, this dehumidifier has been imported into the U.K. by; Please record, for future reference, your date of purchase and where you bought the dehumidifier Meaco (U.K.) Limited from here. Meaco House Parklands Railton Road Date of purchase.... Guildford GU2 9JX Purchased from www.meaco.com (if not then please record the supplier s name below ). Telephone: 01483 234900/0500 418458 Email: customerservice@meaco.com Website: www.meaco.com Fax: 01483 232700.. Meaco are specialists in dehumidifiers and would welcome your comments and questions on this dehumidifier. If you do develop a fault within the first year then please do call us and if we cannot fix the problem over the phone we will be happy to collect the dehumidifier from you at our expense and repair or replace as appropriate. Please save the box just in case this happens. Meaco 08/14 version 1.0