IO-DIM6 6-Channel, Digital to Analogue Converters



Similar documents
IO-RM3 3-Stage Relay Module

WD-AMX Water Detection Controllers

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

DMX2PWM 9 Channel Dimmer Setup Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

DLP-PU/E Instruction Manual

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Duct Humidity Transmitter

SYSTEM DESCRIPTION Termination Boards

Modular I/O System Analog and Digital Interface Modules

Contents. Document information

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

L5354 ControlNet Communications Interface

MINI MCR-SL-R-UI(-SP)

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Original instructions Tina 3A/Aps Adaptor unit

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

Tina 2A/B Adaptor unit

Actuator for modulating control AME 435

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

FIRERAY 2000 Installation Guide

Radiant Temperature Sensor TY7321

Digital input modules

Square D Clipsal C-Bus Network Analyzer

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Electronic Control Devices The European Product Catalogue 2007

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

PSC-A5 Solar Charge Controller Manual

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

9448 Installation and User Guide

PRODUCT DATA SHEET AUDIO LINE COMBINATION ALC

User Manual for CH-PFC76810

Model: DC-A2IO Advanced HVAC Controller

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

connecdim Gateway G1 Ethernet TCP/IP to DALI

Installation manual. Generator Paralleling Controller GPC multi-line C

3M Wrist Strap and Footwear Tester 740. User s Guide

EGSTON Standard E2xFxWx 12W

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

IRT Eurocard. Types DAX-3200

NC-12 Modbus Application

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

PD 100A. Printing data system

Features, Benefits, and Operation

Solid-State Timer H3G

NGC-30-CR -CRM -CRMS -CTM -CVM

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

3500/40M Proximitor* Monitor

CQM1-SF200/CS1W-SF200

Product and functional description

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

HP UPS R1500 Generation 3

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

3500/62 Process Variable Monitor

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Digital Keypad Use s Manual

Total solder points: 167 Difficulty level: beginner advanced DMX CONTROLLED RELAY K8072 ILLUSTRATED ASSEMBLY MANUAL

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Power Supplies 3. SDN-P DIN Rail Series

Absolute Rotary Encoder E6CP

instabus KNX / EIB System System E F G H

Electronic Pressure Switch EDS 300

TrueAlarm Fire Alarm Systems

M3-ATX-HV. 6-34V Intelligent ATX Power Supply. Installation Guide Version 1.0c P/N M3-ATX-HV-01

HM-W536 Install Guide

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

VOICE RECORDING SYSTEM ISDN PRI / BRI

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

POINTS POSITION INDICATOR PPI4

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L LC-1CH-MULTI Dimmer Module

SYSTEM 45. C R H Electronics Design

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

EXTERNAL DIMENSIONS AND PARTS


ATL Fuel Level Sender Probes

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Transcription:

Page 1 of 6 IO-DIM6 6-Channel, Digital to Analogue Converters Features: Benefits: Input status indication Calibrated output DIN Rail mounting Expands controller input capacity Fault finding LED indication Relay status LED indication Technical Overview The IO-DIM6 module is intended for use the BMS controllers to expand their input capacity, by multiplexing 6 digital signals or 24Vac/dc inputs into a single analogue controller input. Each combination of input states corresponds to an analogue value from the IO-DIM6, which can be decoded into 6 digital status bits.

Page 2 of 6 Specification: Inputs Outputs: Power supply: 0-10Vdc or 24Vac or 24Vdc (>17.5V =, <7.5V = OFF) 0-10Vdc into 2kΩ impedance 4-20mA into 500Ω max. 24Vac ±15% @ 50Hz or 24Vdc +15% -6% 4-20mA 24Vdc +15% -6% Current: Voltage output 35mA max. Current output 55mA max. LED indication: Supply OK Supply voltage low Supply voltage high Current output (4-20mA output only) Manual override On/Auto for each input Electrical Terminals Rising cage connectors for 0.5-2.5mm² cable Ambient range: Temperature -10 to +50 C (14 to 122 F) RH 0 to 80% non-condensing Dimensions (H x W x D): 75 x 75 x 42mm (2.95 x 2.95 x 1.65 ) Country of origin UK Part Codes: IO-DIM6 6 x or 24Vac/dc inputs

Page 3 of 6 Installation: Antistatic precautions must be observed when handling these modules. The PCB contains circuitry that can be damaged by static discharge. 1. The IO-DIM6 should only be installed by a competent, suitably trained technician, experienced in installation with hazardous voltages. (>50Vac & <1000Vac or >75Vdc & 1500Vdc) 2. Ensure that all power is disconnected before carrying out any work on the IO-DIM. 3. Maximum cable is 2.5mm², care must be taken not to over tighten terminals. 4. When mounting the IO-DIM6 care should be taken not to stress the PCB when fitting to the DIN rail. If it is necessary remove the module from the DIN rail, be sure to use a flat bladed screwdriver to release the DIN clips. 5. The IO-DIM6 is designed to operate from a 24Vac/dc supply (so that power can be drawn from a 24Vac transformer used for other purposes if a 24Vdc supply is not available). In either case one side of the supply is common to the signal ground from the BEMS controller. 6. The outputs of the modules are pre-calibrated and no adjustment is required. The output is also self-calibrating, to ensure that the output is always correct. LED Status: Power Supply Normal: The green LED indicates the supply power condition. If the power supply is normal (between 22V and 40V) the green LED is continuously, showing that the IO-DIM is powered correctly. Low Supply Voltage: If power supply falls below about 22V the green LED double flashes twice a second; *-*-----*-*-----*-*-----*-* The PCB tries to maintain the correct output but may be unable to achieve the specified voltage or current level. High Supply Voltage: If the power supply is above 40V the green LED flashes 6 times a second; *-*-*-*-*-* The PCB tries to maintain the correct output. Output The Red LED is lit when the PCB is in 4-20mA mode and working correctly. For this to be the case, these conditions must be met: 1. The output select jumper must be connected in the 4-20mA position 2. The output terminals must be connected through an impedance of 500Ω or less. 3. The PCB is capable of sourcing the correct output current. (The red LED may flash if the PSU is below 22V or the impedance is more than 500Ω.)

Page 4 of 6 Connections & Jumper Settings: Red LED Green LED Output signal Output signal link: 0-10Vdc output signal 24V 0V 0V OP 4-20mA output signal 0-10V 4-20mA Override links: On Off IN1 IN2 IN3 IN4 IN5 IN6 0V Input status LED s Override links Examples: 24V switching: switching IN1 IN2 IN3 IN4 IN5 IN6 0V IN1 IN2 IN3 IN4 IN5 IN6 0V + - 24Vac/dc Source

Page 5 of 6 Output Tables: Input Status Nominal Output IN1 IN2 IN3 IN4 IN5 IN6 Vdc ma OFF OFF OFF OFF OFF OFF 0.08 4.12 OFF OFF OFF OFF OFF 5.08 12.12 OFF OFF OFF OFF OFF 0.23 4.38 OFF OFF OFF OFF 5.23 12.38 OFF OFF OFF OFF OFF 0.39 4.62 OFF OFF OFF OFF 5.39 12.62 OFF OFF OFF OFF 0.55 4.88 OFF OFF OFF 5.55 12.88 OFF OFF OFF OFF OFF 0.70 5.12 OFF OFF OFF OFF 5.70 13.12 OFF OFF OFF OFF 0.86 5.38 OFF OFF OFF 5.86 13.38 OFF OFF OFF OFF 1.02 5.62 OFF OFF OFF 6.02 13.62 OFF OFF OFF 1.17 5.88 OFF OFF 6.17 13.88 OFF OFF OFF OFF OFF 1.33 6.12 OFF OFF OFF OFF 6.33 14.12 OFF OFF OFF OFF 1.48 6.38 OFF OFF OFF 6.48 14.38 OFF OFF OFF OFF 1.64 6.62 OFF OFF OFF 6.64 14.62 OFF OFF OFF 1.80 6.88 OFF OFF 6.80 14.88 OFF OFF OFF OFF 1.95 7.12 OFF OFF OFF 6.95 15.12 OFF OFF OFF 2.11 7.38 OFF OFF 7.11 15.38 OFF OFF OFF 2.27 7.62 OFF OFF 7.27 15.62 OFF OFF 2.42 7.88 OFF 7.42 15.88 OFF OFF OFF OFF OFF 2.58 8.12 OFF OFF OFF OFF 7.58 16.12 OFF OFF OFF OFF 2.73 8.38 OFF OFF OFF 7.73 16.38 OFF OFF OFF OFF 2.89 8.62 OFF OFF OFF 7.89 16.62 OFF OFF OFF 3.05 8.88 OFF OFF 8.05 16.88 OFF OFF OFF OFF 3.20 9.12 OFF OFF OFF 8.20 17.12 OFF OFF OFF 3.36 9.38 OFF OFF 8.36 17.38 OFF OFF OFF 3.52 9.62 OFF OFF 8.52 17.62 OFF OFF 3.67 9.88 OFF 8.67 17.88 OFF OFF OFF OFF 3.83 10.12 OFF OFF OFF 8.83 18.12 OFF OFF OFF 3.98 10.38 OFF OFF 8.98 18.38 OFF OFF OFF 4.14 10.62 OFF OFF 9.14 18.62 OFF OFF 4.30 10.88 OFF 9.30 18.88 OFF OFF OFF 4.45 11.12 OFF OFF 9.45 19.12 OFF OFF 4.61 11.38 OFF 9.61 19.38 OFF OFF 4.77 11.62 OFF 9.77 19.62 OFF 4.92 11.88 9.92 19.88

Page 6 of 6 Scaling & Type 18 Function Module (Trend Controls only): Non-characterise scaling: 0-10Vdc Output: 4-20mA Output: Trange 257 Trange 247 Brange -255 Brange -372 Upper 228 Upper 248 Lower -256 Lower -373 Exponent 3 Exponent 4 Characterise scaling: 0-10Vdc output: 4-20mA output: Scaling type 5 Scaling type 5 Input type 0 (voltage) Input type 2 (current) supper 256 supper 256 slower 0 slower 0 Points used 2 Points used 2 Input 1 = 0.23 Output 1 = 4 Input 1= 4.12 Output 1= 3.5 Input 2 = 9.92 Output 2 = 253 Input 2= 19.88 Output 2= 253 The alarm byte associated with a Trend type 18 function module consists of 8 bits. For example, F1 (function 1) has a default destination of A101 (analogue node 101), which in turn is associated with alarm digital byte 141. The table below shows which bit of the alarm byte is affected by which input of the IO-DIM6, and assumes function 1 is used as the A/D (i.e. alarm byte 141). IO-DIM6 Input Alarm Bit IN1 141.2 IN2 141.3 IN3 141.4 IN4 141.5 IN5 141.6 IN6 141.7 Whilst every effort has been made to ensure the accuracy of this specification, Sontay cannot accept responsibility for damage, injury, loss or expense from errors or omissions. In the interest of technical improvement, this specification may be altered without notice.