3M Housings DS Series



Similar documents
Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

CUNO TM Series NB Bags for Liquid Filtration

LifeASSURE BLA. Series cartridge fi lters

Lenntech ZETA PLUS CP & SP SERIES GRADE CHOICE. Pharmaceutical Applications

High Flow. Filtration. Performance. in a Compact Design. 3M Filtration Full Line Catalogue

SUPRApak S Series Filter Housings SUPRApak Filtration For Small Batch Depth Filtration

LifeASSURE 020SP. Series Capsules & Cartridge Filters. Sterilising Grade Nylon 6,6 Membrane Filter

HIGH VELOCITY WATER SPRAY NOZZLE

LifeASSURE PFS. Series Capsules & Cartridges Sterilising Grade PTFE Membrane Filters. 3M Purification. Product brochure

CUNO High Flow Filtration Systems

FOAM CHAMBER MODEL - FC

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100

Super Slider ADJUSTABLE FROM Model #HD26229

Model: Model: Description: Voltage: Amps: Ice Type: Unit Weight:

Document Library TS Data Sheet M Windo-Weld Super Fast Urethane. Data Sheet. Public

SUPRApak M Series Filter Systems SUPRApak Filtration For Medium Batch Depth Filtration

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

ANGLgear. right angle drives Inch and Metric Series. The Original Right Angle Gear Drive Made in the U.S.A.

BY MCI SOLUTIONS SECONDARY CONTAINMENT ADAPTOR

LifeASSURE PFS Series Filter Cartridge Integrity Testing

VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249

OWNER S MANUAL. Certified to NSF/ANSI 61. This product is covered by one or more of the following US patent US D692, 524 S


SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration

HotLok Pass Through Blanking Panel

Technical Data. Installation

Select Radiators Installation Guide

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Installation Instructions

the Company will not warrant ANSI A156.2 Grade 2 lever Product installed in educational facilities and student housing.

Single Port T1/E1 Tap

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER DS BMW 335i 3.0L

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

James M. Pleasants Company

Machine Safety Switch: SI-LM40 Series Limit Switch Style

Lenntech Tel Fax

Installation and Maintenance Instructions

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

4077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE FAX

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

Installation Instructions / Warranty

Calvert USA, Inc. Attic Stairs

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

Architect/Contractor Information Package

Physical. Electrical. Environmental. Insulation: Contact: Plating: Temperature Rating: -55 C to +85 C

Explosion proof enclosures

Installation Instructions

MODEL G300 BRAKE BLEEDER

Installation, Maintenance, & Repair Series 4000B/LF4000B

Industrial Adhesives and Tapes Division 3M Center Building 225-3S-06 St. Paul, MN

Honeywell Pressure Switches Line Guide

Installation Instructions

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Unpacking, Installation, and Customization

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

Ceiling Mount Air Handler Manual

Light Duty Commercial Electric Water Heater

TRANSLATION OF THE ORIGINAL MANUAL

INSTALLATION INSTRUCTIONS. SharkBite. Connection System. The SharkBite System

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Fisher 377 Trip Valve

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

Mounting Details - Footpads & Brackets

Say Hello to Your Precision Cooker

RUBBER SLEEVE KNIFE GATE VALVE

Bypass level indicator With magnetic display Model BNA

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000

Plate heat exchanger. Applications General heating and cooling duties. Heating by means of steam.

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Terminal Box. Specifications TNCN

SAVARD PLUMBING COMPANY

Sun Vinyl New Construction Windows Homeowner's Warranty

Model/Sprinkler Identification Numbers

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

15/40/80CN Series Coreless Medium Pressure Filters

Installation Instructions / Warranty

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Compact pressure switch Flameproof enclosure Ex d Model PCA

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

12U Adjustable 4 Post Open Frame Server Rack

81000 Series Aluminum Gate Valve Installation and Repair Manual

MS900AC-B-LS User Information

Solar Mounting System

Workshop Compressors CLASSIC Series

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

PALLET JACK TON

Document Library TS Data Sheet

Compact, High-Flow Gas Regulators

Filter Housing SG Standard

Wanda Technology Inc. Side Post Aluminum Umbrella OWNER S MANUAL

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves

SSNICLRG SSNICSM PLNICLRG PLNICSM

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

CRN A-F-G-E-HQQE 3x400D 50 HZ

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

Transcription:

Lenntech info@lenntech.com Tel. +1-15-610-900 www.lenntech.com Fax. +1-15-616-89 M Housings For Filters Filter Housings, constructed of durable stainless steel, meet general-purpose industrial, chemical, commercial and some food & beverage filtration needs. All wetted surfaces are 16L stainless steel. Other parts (V-band clamp, feet mountings, etc.) supplied in 04 stainless steel or similar. DS filter housings are electro-polished for a consistent, easy care finish. The filter housings are available in a variety of sizes to accommodate 5 or 1 filter cartridges with lengths from 9 ¾ to 40 inches (or 5 to 48 EQSLs). The housing handles liquids at pressures up to 10 bar g and temperatures of up to 10 C. Specifications Table 1 gives standard model specifications for the Filter Housings. Note that maximum operating pressure and temperature is the rating for the housing only. Actual housing operating temperature depends on temperature and chemical capability of the filter cartridge and gasket used in the housing. Requirements fi lter housings accept both single and multiple filter length cartridges. Table lists the number of filter cartridges for each model housing. Pressure Equipment Directive 97//CE DS housings are in compliance with Non Coded Article.. Sound Engineering Practice. In addition, DS housings are only to be used for the filtration of Group Liquids (and Group 1 Liquids at reduced operating pressures). Do not use DS housings with gas or vapour applications. ATEX Directive 94/9/CE The 05 DS housings are approved for use in ATEX condition II//G/T4 and the 1 DS housings in ATEX condition II//G/T5. The user of these housings must ensure that they are used in accordance with the requirements of these PED and ATEX directives at all times. Please consult your local M Purification representative for any other classification or further information. Applications Chemicals & Petrochemicals Food & Beverage Healthcare Industrial Processes Paint & Coatings Industrial Water Treatment Features & Benefi ts 16L stainless steel construction Provides excellent corrosion protection for rugged, long-lasting service. Accepts varying length cartridges Allows use of 9 ¾ to 10 inch modular cartridges for greater fl exibility. Shouldered seal plates Solid fi t into cartridge core ensures positive seal and prevents bypass. V-Band Clamp and Swing bolt designs Optimizes cartridge change-out. Removable cartridge posts Easy cleaning reduces maintenance. Housing drains located on dirty and clean chambers Allows full drainage of chambers for optimised fi lter change-out. Air Vent Allows venting before start-up and draining for safe fi lter operation. Pedestal cup fitting Allows for use of both DOE or SOE cartridges.

Flow Rates Table 1 lists the maximum water flow rates in liters per minute (l/min) for each model filter housing. Use the data in Table 1 only as a guide in establishing the maximum housing flow capacity; do not use it for filter sizing. Once a flow rate for a selected cartridge is known, use Table 1 to check whether the housing s flow rate falls within the recommended guidelines. Picture 1 1DS top spring assembly (05DS does not use spring or upper cup) Double Open-end (DOE) Single Open-end (SOE) with Locating Spear When sizing a filter, the amount of contaminant load needs to be considered in addition to the flow rate and desired pressure drop. Low initial pressure drop enhances filter cartridge life. Seal Assemblies Standard housings are configured to accept double open end style (DOE) cartridges. These DS DOE housings use pressure plate assemblies including top cup and spring seal assemblies (Picture 1) that permit the use of filter cartridges with single length equivalents of 9 ¾ to 10 inches. To adapt the housing to accept single open end (SOE), double o-ring cartridges with locating spear, the standard pressure plate and the center rod are replaced with the SOE pressure plate and center rod (order separately). Standard Model Dimensions To find a selected dimension, refer to Table to locate the model in the left column and the selected dimension symbol (A-D) in the top row. These dimensions can be used for rough plumbing. For critical installations, request a certified drawing. Table 1 : Standard Model Specifications Housing Type Specifications 05 DS 1 DS Picture DOE Version (standard) Picture SOE Version (optional) Image and are for information only and the actual design may vary from that shown here. Connection Sizes GM (except 05 DS 1 = GM 1,5 ) BP 80 Vent Connections ¼ NPT ½ NPT Drain Connections 1 NPT 1 NPT Sizes (9 ¾ to 10 ) 1,, and 4 high, and 4 high Housing Material 16 L Stainless Steel 16 L Stainless Steel Standard Gasket Material Nitrile Nitrile Max. Operating Pressure 10 bar g 10 bar g Max. Operating Temperature 10 C 100 C Max. Housing Flow Rate 97 l/min 871 l/min Table 1 is intended as a guide. Grade selection and performance should be confirmed with small-scale pilot trial. Table : Requirements Housing Type Single Length (9 ¾ to 10 ) Capacity 05 DS 1 5 05 DS 10 05 DS 15 05 DS 4 0 1 DS 4 1 DS 6 1 DS 4 48

M Housings For Filters Figure 1: Configurations 05 DS 1 DS Table : Standard Model Dimensions Housing Type A* B* C* D Removal Clearance Housing Weight 05 DS 1 495,5 mm 660,5 mm 9 kg 05 DS 749,5 mm 1168,5 mm 11 kg 171,5 mm 7 mm 05 mm 05 DS 100,5 mm 1676,5 mm 1 kg 05 DS 4 157,5 mm 184,5 mm 15 kg 1 DS 1,5 mm 1575,0 mm 69 kg 1 DS 147,0 mm 700 mm 50 mm 500 mm 08,0 mm 77 kg 1 DS 4 17,5 mm 591,0 mm 85 kg * Add 19 mm (¾ ) for leg installation on 5DS housings. All dimensions are subject to normal manufacturing tolerances. M Part Number DS Standard Housings Number of s Vessel type Height Type Materials (Wetted) Gaskets Surface Finish Connection type Connection Size 700046701 05 DS 1 N 6 NB F0 GM 1,5 700046719 05 DS N 6 NB F0 GM 70004677 05 DS N 6 NB F0 GM 70004675 05 DS 4 N 6 NB F0 GM 70004674 1 DS N 6 NB F0 BP 80 700046750 1 DS N 6 NB F0 BP 80 700046768 1 DS 4 N 6 NB F0 BP 80

M Housings For Filters Ordering Guide DS Range Number of s Housing Type Height Type** Construction Material in contact Gasket Material* Surface Finish Connection Type 05 DS 1 N = DOE 6 = 16L NB = Nitrile GM 8 = 1,5 Male BSPT 05 DS 4 N = DOE 6 = 16L NB = Nitrile GM 50 = Male BSPT 1 DS 4 N = DOE 6 = 16L NB = Nitrile BP 80 = DIN PN16 Example: 1 DS N 6 NB BP80 * Other gasket materials and spare parts are available to order on request. Please contact a local M Purifi cation representative for more information. ** SOE is available as option on request. For more information contact your local M Purifi cation representative. Important Notice M Purifi cation MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Since a variety of factors can affect the use and performance of a M Purifi cation product in a particular application, some of which are uniquely within the user s knowledge and control, user is responsible for determining whether or not the M Purifi cation product is fi t for a particular purpose and suitable for user s method of application. Limited Warranty M Purifi cation warrants it this product to be free from defects in material and workmanship during normal use for a period of one (1) year from the date of shipment from the factory. If the Product(s) is (are) defective within this warranty period, your exclusive remedy and M Purifi cation s sold obligations shall be, at M Purifi cation s option, to replace or repair the Product(s) or refund the original purchase price of the Product(s) This warranty does not apply to failures that result from abuse, misuse, alternation or damage not caused by M Purifi cation or failure to properly follow installation and use instructions. Limitation of Liability: M Purifi cation will not be liable for any loss or damage arising from the use of the Product(s), whether direct, indirect, special, incidental, or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specifi c legal rights and you may have other rights which vary from state to state, or country to country. Lenntech info@lenntech.com Tel. +1-15-610-900 www.lenntech.com Fax. +1-15-616-89

The below M- DS series cartridge filter housings are all the models that are potentially possible in all variations. Please note that not all models are actually produced or on stock and some model numbers and names have become obsolete. Nevertheless this should help as cross reference table chart for Cuno filters nomenclature. Filter housing DS series 05DS1N6GM8 05DSN6GM50 05DSN6GM50 05DS4N6GM50 1DSN6BP80 1DSN6BP80 1DS4N6BP80