Apricot Kitchen Sink Tap



Similar documents
Apricot Kitchen Sink Tap

Almond Kitchen Sink Tap

Almond Kitchen Sink Tap

Liquorice Kitchen Sink Tap

Chill 4 Hole Bath Shower Mixer

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

Colonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List

Cadet Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference

Artisan Thermostatic Bath Shower Mixer

Design Utility Lever Thermostatic Bath Shower Mixer

Thermostatic bar showers. Troubleshooting and maintenance

Installation Instructions and User Guide

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

Installation Instructions S

Assembly and instructions

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTIONS BL-8704

Installation Instructions and User Guide

PLUMBING CARE AND REPAIR

INSTALLATION INSTRUCTIONS MK-8704

Shower Handbook (Also covers 650 chrome variant)

Installation Instructions / Warranty

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER

Getting the best from your urn

Safe Touch TMV3 Thermostatic Shower ST10010CP

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation guide Nordic mixer taps. Before installing read this guide first

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

PHOENIX TAPWARE. Gloss. Shower/Wall Mixer RRP: $ Product Code: Available Finishes: GS780. Chrome MATCH WITH...

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

ALTO EV. Installation Instructions Thermostatic Bar Shower Valve

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

BASIC PLUMBING. 2 - Preparation. The simple skills required for basic plumbing are explained in this project.

SHOT BLAST CABINET MODEL NO: CSB20B

STABITHERM INSTALLATION & SERVICE BOOKLET

Please also see 10 golden rules for correct Saniflo installation on

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

FLUSHOMETER - TANK SYSTEM

Installation & User Guide BASIN AND BATH PILLAR TAPS THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 1

Installation Instructions

ACE. PIVOT AND BI-FOLD DOOR Installation and User Guide. These instructions must be left with the user W2-D

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Version: 1.0 TWO HANDLES INWALL WATERFALL FAUCET INSTALL GUIDE

BATHROOM FAUCET ITEM # MODEL # H2. Francias / Español p. 9 ATTACH YOUR RECEIPT HERE

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Please read and keep these instructions. Run water through your machine before first use

REDRING POWERSTREAM-ECO UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

San josé OWNER S MANUAL

Before repairing your toilet, you must determine

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

CW-4622 INSTALLATION INSTRUCTIONS CB-4622 RISER KIT TO SUIT BLACK LEVER EXPOSED VALVES & BATH/SHOWER VALVES


SF15K SF05KSS, SF10KSS

GLOSS SOAP DISH PRODUCT CODE: FINISH: GS895 CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH MATCH WITH...

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

100 Series Maxi Internal Filters. Instruction Manual

V10 THERMOSTATIC SHOWER VALVE PRODUCT MANUAL

Installation Instructions / Warranty

MODEL G300 BRAKE BLEEDER

WATER LEAKS AND DAMAGE

Select Radiators Installation Guide

Fixtures - Parts - Accessories to shampoo bowls

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Installation and Operation Manual

AIRE Thermostatic bath shower mixer Installation and operating instructions

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Hommage 2 PIECE WATER CLOSET BOWL MODEL TANK MODEL 7721 U1 SEAT MODEL

VW GOLF Mk4 TDI FRONT MOUNTING INTERCOOLER INSTALLATION INSTRUCTIONS

CARING FOR YOUR WATER HEATER

Installation Instructions / Warranty

Operators manual Basic water heater

your water pressure explained

A3650/11LMWS (Metal Lever) A3650/11LPWS (Porcelain Lever)

Portable Air Conditioner

Folding Bath Screen Instruction Manual

Visage. Digital. Exposed with adjustable height head. Visage Digital exposed installation instuctions page 1

ClearView 100. Instruction Manual

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

INFRARED QUARTZ WALL HEATER

REPAIR AND MAINTENANCE MANUAL

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

Draining and filling cooling system

This section gives you some helpful information and tips on running your home and the equipment in it.

Stainless Steel Single and Dual Circulation Kits

IMPORTANT INFORMATION

orlando OWNER S MANUAL

A High Bill Usually Means a Leak

B150 Series Commercial Brewer. Direct Plumb Kit

Transcription:

Apricot Kitchen Sink Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts

Contents Thank you for choosing Bristan, the UK s leading taps and showers expert. We have designed this product with your enjoyment in mind. To ensure that it works to its full potential, it needs to be fitted correctly. These fitting instructions have been created to give you all of the information you need and, if you need any further help, please do not hesitate to give us a call on 0844 701 6273. Important Safety Information 03 Dimensions 04 General Specifications 05 Installation Requirements 05-06 Installation 06-08 Operation & Maintenance 09 Troubleshooting 10 Guarantee 11 02

Important Safety Information Please read these instructions thoroughly and retain for future use. All products manufactured and supplied by Bristan are safe provided they are installed correctly, used correctly and receive regular maintenance in accordance with these instructions. If you are in any doubt about your ability to install this product safely you must employ the services of an experienced qualified plumber. Remove all packaging and check the components for damage before starting installation. Before starting any installation please consider the following: Prior to drilling into walls, check that there are no hidden electrical wires, cables or water supply pipes. This can be checked with the aid of an electronic detector. If power tools are used do not forget to: - Wear eye protection - Unplug equipment after use This product must not be modified in any way as this will invalidate the guarantee. These fittings need to be installed in accordance with and meet the requirements of the Water Supply (Water Fittings) Regulations 1999 and Scottish Byelaws 2004. Warning from your water Supplier It could be a criminal offence to use this tap with a mains water supply drawn directly from the supply pipe. (The supply pipe is the one which brings the water supply into your home and is directly connected to the public water main). This tap has an outlet on a flexible hose which, if immersed in water, could result in contaminated water being drawn back into the pipework if the supply pressure dropped. To prevent contaminated water being drawn back into the pipework if the supply pressure dropped. To prevent contamination of drinking water in the premises and in the water main, and to comply with the legal requirement of the UK plumbing regulations and byelaws*, both hot and cold water supplied to this tap must come from a storage cistern. If the distributing pipes feeding this tap from the storage cistern have other outlets connected to them, the outlet of this tap must be lower than any of those other outlets. If installed as a tap which is used for drawing water for drinking, and the quality of water from the storage cistern does not meet the standards for drinking water, a separate tap supplied with wholesome water must be provided for drinking purposes. For further information, contact the Water Regulations department of your local Water Supplier (see WRAS website www.wras.co.uk or Yellow Pages for details) or the Water Regulations Advisory Scheme by e-mail (info@wras.co.uk) or telephone: 01495 248454. The Water Supply (Water Fittings) Regulation 1999 in England and Wales; The Scottish Water Byelaws 2004 and Northern Ireland Regulations. 03

Dimensions 04

General Specifications Operating pressure range (bar) Min Max 1.5 7.0 Installation Requirements. Maximum static pressure 10.0 bar NOTE:- Nominally equal (balanced) inlet supply pressures are recommended for optimum Performance of mixer taps. Designed to comply with BS EN 200 for single taps / combination taps for water systems of type 1 and 2 general technical specifications; and to be used within systems designed to BS 6700. BS 6700 recommends the temperature of stored water should never exceed 65 C. A stored water temperature of 60 C is considered sufficient to meet all nominal requirements and will minimise the build up of lime scale in hard water areas. This fitting needs to be installed in accordance with the following Installation Requirements and Notes (IRN) to ensure they meet the requirements of the Water Supply (Water Fittings) Regulations 1999 and the Scottish Byelaws 2004. For further details contact your Local Water Authority. For backflow protection in premises or installations up to fluid category 5. The vertical distance of the outlet above the spill-over level shall be not less than 20 mm or twice the diameter of the inlet pipe to the fitting, whichever is the greater. If the fitting cannot be installed as indicated it shall be installed:- a) With a backflow prevention arrangement suitable for the Fluid Category or b) So that it draws water by gravity only from a cistern, cylinder or tank having a permanently open vent pipe, the vertical distance between the point at which the pipe or pipes supply water to the fittings is or are connected to the supply and the spill-over level of any fixed appliances is not less than the dimensions stated above, and the vent pipe or pipes supplies no other fittings (other than a draining tap) at a lower level. It is essential that all pipe work is flushed through to remove debris and swarf that could otherwise damage the fitting. Once the pipe work has been flushed through, turn off the water supply at the stop valve. Two non-return valves are supplied with this mixer, one of each should be fitted in the hot and cold water supply to the mixer to prevent the possibility of backflow, however this mixer tap must be installed in accordance with the above mentioned Regulations. Important: Independent stop valves complying with the current water regulations should be fitted as a means of isolating both water supplies to the fitting for servicing and/or maintenance work. 05

Installation Requirements Continued Flexible Connecting Pipes Care must be taken when connecting the flexible connection pipes to the household pipework to ensure they do not bend sharply and kink or twist. See below for recommended ways to fit the flexible connecting pipes Important: Failure to follow these guidelines may result in poor performance and damage to the flexible connecting pipes Installation. 1. Identify all components are present prior to starting installation using the diagram on page 08. 1. Handset x1 16. Threaded Rod x1 2. Handset Connection x1 17. Handle Body x1 3. Spout x1 18. Plinth x1 4. Plastic Washer x1 19. Washer x1 5. Plastic Collar x1 20. O-Ring x1 6. O-Ring x1 21. Hollow Fixing Tube x1 7. Grub Screw Cap x1 22. Handset Hose x1 8. Grub Screw x1 23. Hose Weight x1 9. Mixer Body x1 24. Washer x1 10. Internal Housing x1 25. Fixing Plate x1 11. Housing Retainer x1 26. Adaptor Retaining Screw x1 12. Cartridge x1 27. C Shaped Metal Plate x1 13. Cartridge Retaining Nut x1 28. Small Brass Nut x1 14. Shroud x1 29 Small Brass Adaptor x1 15 Handle Lever x1 30 Non-Return Valve x2 31 Connecting Pipes x2 06

Installation Continued 2. Screw hollow fixing tube (21) into central threaded hole in base of mixer tap (closest hole to mixer lever) with plain shank section close to the mixer body and the two flats away from the mixer body enabling a suitable spanner to be used to tighten securely into mixer body. 3. Fit plinth (18) to base of tap with base O-ring (20) facing towards the sink/work surface. 4. Carefully screw both inlet flexible connecting pipes (31) into outer holes in base of mixer assembly as tight as possible by hand only (DO NOT OVERTIGHTEN). Please note: It may be necessary (depending on size of hole in sink/work surface) to only fit one flexible connecting pipe to the mixer prior to fitting the mixer in order to feed all flexible connecting pipes and fixings through the hole and then fit the second flexible connecting pipe from underneath after fitting the mixer. 5. Fit the mixer tap with plinth fitted to the top of the sink/work surface feeding the two flexible connecting pipes (31) and the black handset hose (22) carefully through the fixing hole. 6. Offer up the black rubber washer (24) plastic fixing plate (25) with flatter surface towards the underside of the sink/work surface and place C-shaped metal fixing plate (27) onto threaded tube (21) making sure it fits into recess in plastic plate (25) and tighten fully to sink/work surface with small brass nut (28). 7. Under sink/work surface screw tighten small brass adaptor (29) on to hollow fixing tube (21). Loosen grub screw (26) sufficiently on brass adaptor end of black hose (22) so that it can be fitted to small brass adaptor (29). Push fully on to adaptor and tighten grub screw (26). 8. Split the two halves of the black hose weight (26) by removing both screws and place around the black hose (27) towards the bottom of the hose so that it is pulling the pullout handset back into the spout (3) and replace both screws and tighten. 9. Connect both inlet flexi connecting pipes (25) with a non-return valve (31) fitted in each between the connecting pipes and the hot and cold water supplies/household pipe work with the arrow on the casing pointing in the direction of the water flow. (The cold inlet pipe under the mixer should be to the rear of the mixer and hot towards the front when viewed from the front). Please Note: Care must taken when connecting the flexible connection pipes to the household pipe work to ensure they do not bend sharply and kink or twist. See page 05 for recommended ways to fit the flexible connecting pipes: Important: Failure to follow these guidelines may result in poor performance and damage to the flexible connecting pipes. 10. Carefully turn on both water supplies and gently turn on mixer by lifting the lever to the fully on position and let run for a few minutes checking all joints and connections for leaks. 07

Installation cont. 3 2 1 4 6 5 7 9 18 8 10 11 12 15 19 20 13 16 22 21 24 14 17 25 23 31 26 27 28 29 30 08

Operation. Moving the lever outward/inward from the mixer body will turn on/off and increase/decrease the flow of water. Moving the lever either backwards or forwards (when the mixer is viewed from the front) will increase/decrease the water temperature. The pull out handset incorporates a push button enabling the water flow to be altered from an inner water stream to a wider outer spray pattern. Maintenance General Cleaning Your fitting has a high quality finish and should be treated with care to preserve the visible surfaces. All finishes will wear if not cleaned correctly. The only safe way to clean your product is to wipe with a soft damp cloth. Stains can be removed using washing up liquid. All bathroom cleaning products (powders and liquids) will damage the surface of your fitting, even the non-scratch cleaners. Note: Never use abrasive detergents or disinfectants or those containing alcohol, hydrochloric acid or phosphoric acid. If your fitting begins to leak the following should be carried out; Isolate both hot and cold water supplies to the tap by either: Turning the water supply off at the mains stopcock or Turning off the isolation valves to the tap. 1. Remove the handle lever (15) on the handle body (17) to reveal the concealed threaded rod (16). 2. Unscrew the threaded rod (16) and pull the handle away from the mixer body. 3. Unscrew the shroud (14), remove the cartridge retaining nut (13) and pull out the cartridge (12). 4. Carefully clean the cartridge seals and seating. 5. If necessary replace the cartridge. Please visit www.bristan.com/sparesfinder in order to find spare parts for this product. 6. Replace the cartridge into the tap body and tighten retaining nut fully. 7. Replace all remaining components and turn on water supply. 8. Check for leaks and contact our helpline if problem persists. 09

Troubleshooting Symptom No flow or poor flow rate. Cause Partially closed stop or service valve in water supply pipework to the tap. Head of water is below the minimum distance required. Remedy Open stop or service valve. Refer to the Specification section for minimum pressures required. Water dripping for a few seconds after the tap has been turned off. Constant dripping / leaking when the tap is not in use. Possible airlock / blockage in supply pipework Cartridge / Valve not opening fully. This is caused by capillary action and residual water in the spout being siphoned out. This should only last for a couple of seconds. Cartridge / Valve not fully shutting off. Remove water supplies from the fitting and flush the system to remove any airlocks / debris. Service fitting. Refer to maintenance section on page 09. Service fitting and replace cartridge / valve. Refer to maintenance section on page 09. Fitting does not turn on. Water supplies not turned on. Check that the water supplies to the fitting are turned on. Closed stop or service valve. Open stop or service valve. 10

Bristan Guarantee Bristan offers solid guarantees to provide you with complete peace of mind. Taps and Mixers 5 year parts and 1 year labour*. Gold, painted and special finishes 3 years parts only. All subject to proof of purchase. Mixer Shower Valves 5 year parts. 5 year labour* (subject to registration), or 1 year with proof of purchase. Gold, painted and special finishes 3 years parts only. Pumps and Power Showers 2 year parts. 1 year labour* (subject to registration). Electric Showers/Instantaneous Water Heaters 2 year parts. 1 year labour* (subject to registration). Accessories 5 year parts only. Includes bathrooms accessories, shower accessories (e.g. hoses, handsets and poles), wastes, WC levers and light pulls. Gold, painted and special finishes 3 years parts only. Sanitaryware 5 year parts only. Subject to proof of purchase. *Labour provided by an approved Bristan engineer. Guarantee only applies to products with a manufacturing fault. A deferred payment will be necessary in order to secure any visits by our engineers which will be charged if the problem is found not to be a manufacturing fault. If the fault is found to be down to a manufacturing error, the payment will be released and not charged. This guarantee applies to products purchased within the United Kingdom or Republic of Ireland, but does not apply to products used commercially. The guarantee is only available to original purchasers who have proof of purchase. The installation must allow ready access to all products for the purpose of inspection, maintenance or replacement. Any part found to be defective during the above guarantee period will be replaced without charge, providing that the product has been installed in accordance with the instructions, used as intended, and regularly serviced. Servicing should be carried out at regular intervals of no more than 12 months and more frequently in hard water areas (heavy lime scale) areas. In the unlikely event that any problems are encountered with the product s performance on installation, you must obtain guidance/authorisation from our Customer Service Department, and be able to supply proof and date of purchase, before any remedial action is taken. The guarantee excludes general wear and tear and damage caused by accident, misuse or neglect, and does not cover the following:. Components that are subject to general wear and tear such as filters, seals, O rings and washers etc. Damage caused by faulty installation Damage caused by lime scale or any waterborne debris Damage caused by inappropriate cleaning products (see user instructions) Damage caused by the use of non-bristan parts The product being used for a purpose other than intended by the manufacturer. In the interests of continuous product improvement Bristan reserves the right to alter specification as necessary. 11

This booklet covers product code: APR PULLSNK C Helpline 0844 701 6273 Bristan Group Limited Birch Coppice Business Park, Dordon, Tamworth, Staffordshire B78 1SG A Masco Company Website: www.bristan.com Telephone: 0844 701 6274 Facsimile: 0844 701 6275 Email: enquire@bristan.com FI (APR PULLSNK C) REV. D3