About DENTSPLY Implants

Similar documents
Regular C/X Prosthetics. Prosthetics

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Discover the new ANKYLOS generation: ANKYLOS C/X with the option of indexing & more...

DISCOVER THE NEW ANKYLOS GENERATION: ANKYLOS C/X with the option of indexing & more...

Implanting Brilliancy

CONTENT PLANNING. XiVE Planning Components 4 SURGERY. XiVE Implant Package 6. XiVE Implants 7. XiVE Surgical Kit 10

Restorative Guidelines

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

NARROW DIAMETER implant

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

ATLANTIS abutments design guide CAD/CAM patient-specific abutments

procedures & products NOBELESTHETICS including Procera

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment

DESS. Screws. Tijuana Ventas: (664) /95 For all major implant systems!!

prosthetic technique manual

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS

ATLANTIS ISUS the benchmark for CAD/CAM suprastructures. For all major implant systems

ATLANTIS abutments as individual as your patients

How To Use A Cresco

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

IMPLANT SYSTEM BRIDGE RESTORATIONS WITH THE CAMLOG CROWN AND. a perfect fit

Prosthetic Manual. Implant System. Contact Us: Smarter thinking. Simpler design. Phone: Fax:

More than a fixed rehabilitation.

Implant Bar Overdenture Utilizing Locator Attachments

Crown and Bridge Restorations. Straumann synocta Prosthetic System

Gl GinGival level implant

TRI-CAM Implant System

PROSTHETICS. Crown and bridge restorations with the synocta prosthetic system.

All-on-4 treatment concept with NobelSpeedy Groovy

SynCone C/ Stable prostheses for immediate and delayed restorations: The SynCone concept

Procedures & Products. NobelEsthetics

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

Choosing the right type of abutment

NobelActive. procedures and products

Implant Parts. A Radford Heath Guide 1

BASIC INFORMATION ON THE prosthetic procedures. Straumann Bone Level Implant Line

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

Dr. Abhinav Gupta M.D.S., Certificate D.G.O.I.( Implants) Assistant Professor(Prosthodontics) Dental College, A.M.U., Aligarh.

LOCATOR Implant Attachment System for XiVE, FRIALIT and ANKYLOS Implants

A Review of Implant Abutments - Abutment Classification to Aid Prosthetic Selection

ATLANTIS crown abutment. Patient-specific CAD/CAM abutments for single-tooth, screw-retained restorations

PROSTHETICS. Crown and Bridge Restorations with the synocta Prosthetic System DENTAL IMPLANT SYSTEM

Multi-unit abutment bar overdenture

LOCATOR BAR ATTACHMENT SYSTEM

IMPLANT DENTISTRY EXAM BANK

PROSTHETIC OPTIONS FOR NARROW NECK IMPLANTS. Straumann Narrow Neck

SCD Case Study. Treatment Considerations for Implant Rehabilitation

One Abutment - One Time

Renaissance of One-Piece Implants

GINGIVAL LEVEL implant

Restorative Manual Impression Transfer System

Implants in your Laboratory: Abutment Design

Standard Internal Hex

Clinical and Laboratory Procedures for Fixed Margin Implant Abutments

screw-retained single crowns using custom-cast abutments

MS SA Implant - Narrow Ridge MS SA Implant - Denture. MS Implant - Provisional MS KIT

Prosthodontist s Perspective

Order of Treatment STEP-BY-STEP INSTRUCTIONS TO PLACE LOCATOR ATTACHMENTS

AT THE RIGHT PRICE. ONE SIZE FITS ALL. FRICTION For a secure connection. BONEADAPT For immediate stability.

State-of-the-art for your prostheses

Ceramics on Implants Fixed Zirconium Dioxide-Based Restorations in the Rehabilitation of the Edentulous upper Jaw

ball abutment overdenture: chairside pick-up using existing denture

Dental Implant Restoration

LOCATOR ROOT ATTACHMENT SYSTEM

Procedures & Products Powered by Procera. All-on-4

Milled Bar Overdentures-Protocol and Procedures

PureForm Ceramic System. Emulating nature. The perfect disguise.

Titanium Base for CAD/CAM For single-tooth and bridge solutions

Khaldoon G. Abu Afifeh, B.D.S, M. Sc in Prosthodontics

Straumann Dental Implant System. Fax Order Form Collection.*

Navigator System For CT Guided Surgery Manual

Ridge Reconstruction for Implant Placement

While the prosthetic rehabilitation of

Product Catalog. ERA Mini TM Dental Implant System

SURGICAL MANUAL. Step By Step Techniques

Smile Confidently With DIEM 2. Immediate Full Arch Rehabilitation

GIVE YOUR PATIENTS THE FREEDOM TO EAT, SPEAK AND LAUGH AGAIN.

Simpl Implant Abutments with Atlantis CAD CAM Technology

ANKYLOS. Syncone Concept. The Paradigm For Implant Supported Dentures. Redefining Success In Implant Dentistry

CAD/CAM technology supporting successful implant therapy

Dental implants and Astra Tech

ITI Small Diameter (SD) external hex 3.25 / 3.3 external hex. ITI Standard 4.8 internal non-octagon Morse taper 4.

Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT

New features DWOS 3.2

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

BEGO IMPLANT SYSTEMS PRODUCT CATALOGUE 2015 / Partners in Progress

Implant systems Systematically perfect

Implant Replacement of the Maxillary Central Incisor Utilizing a Modified Ceramic Abutment (Thommen SPI ART) and Ceramic Restoration

platform shifting Nobel Biocare is shifting gingival beauty to the next level

Dental Implant Options in Atrophic Jaws

education Although demographic factors and growing patient awareness of the benefits of dental implants

LOMAS / MONDEFIT ORTHODONTICS. The most innovative anchorage method for tooth correction

Improving Esthetics with Sequential Treatment Planning and Implant-Retained Dentures

Dr. Little received his doctorate degree in dentistry from UT Health at San Antonio Dental

Guidance for implant removal. Straumann Dental Implant System

The IMZ Implant System

ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology

IMPLANTS IN FOCUS. Endosseous dental implant restorations PLANNING FOR IMPLANT RESTORATIONS

Transcription:

Product Catalog

About DENTSPLY Implants Improving patient quality of life requires vision, commitment, creativity, and innovation. We are committed to a thorough scientific approach and clinical evidence for successful, longterm outcomes for the patient. All this permeates and inspires everything we do, every day. Comprehensive and integrated solutions Our solutions are unique in their support of the implant treatment process from beginning to end. They allow dental professionals the freedom to create predictable, lasting, patient-specific outcomes, and are designed to help make your job easier without compromising reliability, long-term function, and esthetics. Our comprehensive product portfolio includes, ASTRA TECH Implant System, and XiVE implant lines, digital technologies such as ATLANTIS patient-specific, CAD/CAM solutions, SIMPLANT computer guided treatment planning, SYMBIOS regenerative solutions, and professional development programs. Research and development Documentation is an essential part of our investment in the development of our products and services. Our research and development efforts focus on all aspects of implant treatment, including more demanding and advanced compromised cases and simplified treatment procedures. The commitment to quality is further supported by our extensive pre-clinical and clinical studies program. Professional development Through documentation updates, seminars, training, and hands-on workshops, we offer education on the latest developments in implant dentistry. As your partner of choice, we can support your practice and business development efforts with patient awareness and education material, and advertising and co-marketing collateral. 1

CONTENTS Surgery Implant packaging concept 4 Implant cover screws 4 Implant diameters and lengths 5 Prosthetics SURGERY Prosthetic concept C/ and /X Introduction 6 Prosthetic concepts C/ (without index) Overview 8 Soft tissue management and abutment assembly 14 Impression taking C/ (without index) Implant level 15 Regular C/* Crown & bridgework, wide abutments 16 Balance Posterior C/ Crown & bridgework, narrow abutments 18 Balance Anterior C/ Anatomical abutments, anterior region 20 Balance Base C/, SmartFix concept* Occlusal screw-retained bridges, bar 22 SynCone C/* Edentulous jaw, prefabricated taper crowns 24 Snap Attachment C/* Edentulous jaw, prefabricated retention elements 26 Prosthetic restorations with extremely thin gingiva 26 LOCATOR C/ Edentulous jaw, prefabricated retention elements 27 Standard C/** Crown & bridgework on abutment level 28 Prosthetic concepts /X (with index) Overview 32 Soft tissue management and abutment assembly 34 Impression taking /X (with index) Implant level 35 Regular /X* Crown & bridgework, wide abutments 36 ATLANTIS Patient-specific CAD/CAM abutments 38 Instruments Surgical instruments Drills, reamers, taps, ratchets 40 Surgical kits 46 Additional surgical instruments Sinus floor elevation, osteotomy, uncovery instruments, accessories surgical unit 50 Prosthetic instruments 54 PROSTHETICS Materials Material specifications 58 * Impression on abutment level as an option ** Impression on abutment level only Information regarding the materials involved in implants, system components and instruments is given in the form of a reference number after every article: Regular C/X Gingiva former 4. Page 59 of this catalog presents an overview of the materials and the composition of the materials used. The pictures in this catalog are for illustration. The size of the illustrated products may deviate from the original product. DENTSPLY Implants reserves the right to make any technical changes without prior notice. 3 instruments

Implant packaging concept C/X implants are supplied in double-sterile blister package with an outer carton. This type of package offers the maximum possible product safety in conformance with the increasingly rigid requirements for medical devices. The packaging also makes it easy to store all products for quick retrieval and they are easy to handle during the surgical procedure. Outer box package Simple product classification with brandspecific design, sight window and colorcoded imprint of the implant diameter Large seal label with details of products Stackable, all important product information remains visible Includes multilingual instructions for use Transparent outer blister Outer sterile barrier of implant package Transparent inner blister Inner sterile package Contains implant shuttle with implant and cover screw for implants Peel-off label with batch number for reliable documentation of treatment Plastic implant shuttle Holds the implant securely in the packaging and protects it from damage Makes non-contact transfer and pick-up of the implant easy during the operation Three wings with roughened surfaces for non-slip holding make it very easy to handle safely Implant cover screws Cover Screw (as spare part) Membrane Screw Ø 3.5 mm Ø 6.0 mm Ø 6.0 mm sinus lift, 1 mm Ø 6.0 mm sinus lift, 2 mm Screw driver 1.0 mm hex 1.6 mm slot 1.6 mm slot 1.0 mm hex 1.0 mm hex Order no. 31010480 31010110 31010120 31010130 31010140 4

Implant diameters and lengths C/X Implant 2 (sterile) C/X Implant 2 (sterile) Included: Screw implant with cover screw (included) and premounted placement head Ø Lengths Order no. A8 A9.5 A11 A14 A17 3.5 mm 3.5 mm 3.5 mm 3.5 mm 3.5 mm 8 mm 9.5 mm 11 mm 14 mm 17 mm 31010405 31010408 31010410 31010420 31010422 Indications for use The C/X implant system is for single-stage or two-stage surgical procedures and cemented or screw retained restorations. The C/X implant system is intended for immediate placement and function on single tooth and/or multiple tooth applications when good primary stability is achieved, with appropriate occlusal loading, in order to restore chewing function. Multiple tooth applications may be splinted with a bar. SURGERY Healing mode Submerged or transgingival with gingiva-forming component B8 B9.5 B11 B14 B17 Ø Lengths Order no. 4.5 mm 4.5 mm 4.5 mm 4.5 mm 4.5 mm 8 mm 9.5 mm 11 mm 14 mm 17 mm 31010425 31010428 31010430 31010440 31010450 C8 C9.5 C11 C14 C17 Ø Lengths Order no. 5.5 mm 5.5 mm 5.5 mm 5.5 mm 5.5 mm 8 mm 9.5 mm 11 mm 14 mm 17 mm 31010453 31010455 31010458 31010460 31010470 INSTRUMENTs Placement of implants: Implant Driver Unscrewing Placement Head, placement of Cover Screw: Screwdriver 1.0 mm hex Ø Lengths Order no. D8 D9.5 D11 D14 7 mm 7 mm 7 mm 7 mm 8 mm 9.5 mm 11 mm 14 mm 31010472 31010474 31010476 31010478 Placement of implants and unscrewing the Placement Head without changing the instrument: Implant Driver C/X with Screwdriver 5

Prosthetic concept C/ and /X introduction Choice between non-indexed and indexed prosthetics with easy positioning of the abutments Non-indexed components for free positioning of abutments Indexed components for precise and straightforward placement of abutments in six possible positions Tapered TissueCare connection for optimal stability and rotation locking with all types of implants C/ /X Only C/X leaves the choice up to you: Use the index as orientation aid whenever this facilitates the prosthetic protocol. Use the tapered connection geometry when it is preferable within prosthetic protocol, e.g. with SynCone. Both procedures provide the possibility of free combination, i.e. each abutment fits into each implant. Balance Anterior C/X CERCON Balance C/ Regular C/X Balance Base Abutment C/ SynCone C/ LOCATOR C/ Snap Attachment C/ Standard C/ CAD/CAM Attachments 6

C/X Construction principles of abutments Gingiva former Most gingiva formers are one-piece components for insertion into the implant with the 1.0 mm hex screw driver. The Balance Anterior C/ sulcus former is a two-piece component with separate screw to allow for customization and fixation in the desired position. Use the 1.0 mm hex screw driver to fasten the screw. Temporary abutments The Balance C/ temporary abutments are made from zirconia-reinforced PEEK as two-piece components with separate screw (1.0 mm hex). Transfer posts Transfer posts are available for pick-up and repositioning technique. Transfer posts C/ transfer the implant position without index. Transfer posts /X transfer the implant position and the orientation of the index. Therefore they are longer. All transfer posts show a 1 mm hex at the occlusal aspect, which should be used only for loosening of abutments. Transfer posts C/ for pick-up technique are two-piece components with separate screw. The transfer posts C/ for repositioning technique are one-piece components. Transfer posts /X always have an integrated fixation screw. Prosthetic abutments Many of the prosthetic abutments (e.g. Regular abutments) have an integrated fixation screw. This fixation screw is mobile but not removable. Abutments with integrated fixation screw are always screwed into the implant with the 1.0 mm hex screw driver. One-piece abutments (e.g. Balance Base narrow, straight) are inserted with special instruments depending on the abutment head. PROSTHETICS All prosthetic components are laser-marked to indicate their use: Components marked with C/ only use the cone for the connection and are not indexed. This means that the abutment components can be positioned as desired and are completely friction-locked by the cone in order to prevent rotation. Components marked with /X are indexed. The index is used to position the abutments in the implants in one of six possible positions. In this case, it is also the cone that ensures optimum stability and rotation locking. Components marked with C/X are used for indexed or non-indexed prosthetics. Please note: C/X implants must only be used with components that are laser-marked with C/X, C/ or /X, or that belong to the following product groups: Balance Anterior and Posterior abutments and repositioning posts, CERCON Balance, Balance temporary abutments, Balance Anterior sulcus formers and SynCone abutments. 7

Prosthetic concepts C/ (without index) overview Crown & bridgework Gingiva formers / sulcus formers Transfer on implant level Balance Anterior C/ Balance Anterior C/ Sulcus Former 31021510 1.5 small 31021515 3.0 small 31021520 1.5 large 31021525 3.0 large Cercon Balance C/ Balance Anterior C/ Sulcus Former 31021510 1.5 small 31021515 3.0 small 31021520 1.5 large 31021525 3.0 large 31045400 Transfer Screw C/, short 31045402 Transfer Screw C/, long 31045410 Transfer Post C/, short 31045412 Transfer Post C/, long Regular C/ 31045415 Repositioning Post C/ 31045416 Repositioning Post C/, narrow Regular C/X Gingiva Former 31024010 GH 0.75 31024012 GH 1.5 31024014 GH 3.0 31024016 GH 4.5 31045270 Balance C/ Implant Analog A 8

C/ Abutments Transfer on abutment level, abutment analog Accessories Screw retention Balance Anterior C/ Abutment 31021550 small GH 1.5 A 0 31021560 small GH 3.0 A 0 31021590 small GH 1.5 A 15 31021600 small GH 3.0 A 15 31021570 large GH 1.5 A 0 31021580 large GH 3.0 A 0 31021610 large GH 1.5 A 15 31021620 large GH 3.0 A 15 31056301 Fixation Screw Lateral Hexagon M 1.4 Cercon Balance C/ Abutment neutral dentine 31023010 3102 3310 small GH 1.5 A 0 31023015 3102 3315 small GH 3.0 A 0 31023030 3102 3330 small GH 1.5 A 15 31023035 3102 3335 small GH 3.0 A 15 31023050 3102 3350 large GH 1.5 A 0 31023055 3102 3355 large GH 3.0 A 0 31023070 3102 3370 large GH 1.5 A 15 31023075 3102 3375 large GH 3.0 A 15 Regular C/ Abutment 31024150 GH 0.75 A 0 31024160 GH 1.5 A 0 31024170 GH 3.0 A 0 31024180 GH 4.5 A 0 31024151 GH 0.75 A 7.5 31024161 GH 1.5 A 7.5 31024171 GH 3.0 A 7.5 31024181 GH 4.5 A 7.5 31024152 GH 0.75 A 15 31024162 GH 1.5 A 15 31024172 GH 3.0 A 15 31024182 GH 4.5 A 15 31024153 GH 0.75 A 22.5 31024163 GH 1.5 A 22.5 31024173 GH 3.0 A 22.5 31024183 GH 4.5 A 22.5 31047120 Regular C/X 3-in-1 Cap A 0 31047110 Regular C/X Abutment Analog A 0 31047121 Regular C/X 3-in-1 Cap A 7.5 31047111 Regular C/X Abutment Analog A 7.5 31047122 Regular C/X 3-in-1 Cap A 15 31047112 Regular C/X Abutment Analog A 15 31047123 Regular C/X 3-in-1 Cap A 22.5 31047113 Regular C/X Abutment Analog A 22.5 Temporary Abutment 31023311 small 1.5 A 0 31023316 small 3.0 A 0 31023331 small 1.5 A 15 31023336 small 3.0 A 15 31023351 large 1.5 A 0 31023356 large 3.0 A 0 31023371 large 1.5 A 15 31023376 large 3.0 A 15 31056304 Horizontal Screw Seat for Fixation Screw M 1.4 31056301 Fixation Screw Lateral Hexagon M 1.4 31056304 Horizontal Screw Seat for Fixation Screw M 1.4 PROSTHETICS 9

Prosthetic concepts C/ (without index) overview Crown & bridgework Balance Posterior C/ Gingiva formers / sulcus formers Transfer on implant level Regular C/X Gingiva Former 31021528 GH 0.75 31021530 GH 1.5 31021535 GH 3.0 31021540 GH 4.5 31045400 Transfer Screw C/, short 31045402 Transfer Screw C/, long 31045410 Transfer Post C/, short 31045412 Transfer Post C/, long 31045415 Repositioning Post C/ 31045416 Repositioning Post C/, narrow 31045270 Balance C/ Implant Analog A Standard C/ Standard C/ Sulcus Former 31021011 a / 1.5 31021021 a / 3.0 31021026 a / 4.5 31021028 a / 6.0 31021031 b / 1.5 31021041 b / 3.0 10

C/ Abutments Transfer on abutment level, abutment analog Accessories Screw retention Balance Posterior C/ Abutment 31021625 GH 0.75 A 0 31021647 GH 0.75 A 7.5 31021648 GH 0.75 A 15 31021630 GH 1.5 A 0 31021649 GH 1.5 A 7.5 31021650 GH 1.5 A 15 31021640 GH 3.0 A 0 31021660 GH 3.0 A 15 31021645 GH 4.5 A 0 31021665 GH 4.5 A 15 31056051 Retaining Screw Lateral Hexagon M 1 x 0.2 31056052 Sleeve for Retaining Screw Lateral Hexagon Standard C/ Abutment 31021050 a / 1.5 / 4.0 A 0 31021070 a / 3.0 / 4.0 A 0 31021076 a / 4.5 / 4.0 A 0 31021078 a / 6.0 / 4.0 A 0 31021130 a / 1.5 / 4.0 A 15 31021150 a / 3.0 / 4.0 A 15 31021060 a / 1.5 / 6.0 A 0 31021080 a / 3.0 / 6.0 A 0 31021140 a / 1.5 / 6.0 A 15 31021160 a / 3.0 / 6.0 A 15 31021090 b / 1.5 / 4.0 A 0 31021110 b / 3.0 / 4.0 A 0 31021170 b / 1.5 / 4.0 A 15 31021190 b / 3.0 / 4.0 A 15 31021100 b / 1.5 / 6.0 A 0 31021120 b / 3.0 / 6.0 A 0 31021180 b / 1.5 / 6.0 A 15 31021200 b / 3.0 / 6.0 A 15 31045011 TransferCap a / / 4.0 31045140 Lab. Analog a / / 4.0 A 0 31045142 Lab. Analog a / / 4.0 A 15 31045021 TransferCap a / / 6.0 31045150 Lab. Analog a / / 6.0 A 0 31045152 Lab. Analog a / / 6.0 A 15 31045031 TransferCap b / / 4.0 31045160 Lab. Analog b / / 4.0 A 0 31045162 Lab. Analog b / / 4.0 A 15 31045041 TransferCap b / / 6.0 31045170 Lab. Analog b / / 6.0 A 0 31045172 Lab. Analog b / / 6.0 A 15 31045180 Wax-up Coping a / -- / 4.0 crown 31045182 Wax-up Coping a / -- / 4.0 bridge 31045190 Wax-up Coping a / -- / 6.0 crown 31045192 Wax-up Coping a / -- / 6.0 bridge 31045200 Wax-up Coping b / -- / 4.0 crown 31045202 Wax-up Coping b / -- / 4.0 bridge 31045210 Wax-up Coping b / -- / 6.0 crown 31045212 Wax-up Coping b / -- / 6.0 bridge 31056022 Fixation Screw Occlusal M 1.6 31056051 Retaining Screw Lateral Hexagon M 1 x 0.2 31056052 Sleeve for Retaining Screw Lateral Hexagon PROSTHETICS 11

Prosthetic concepts C/ (without index) overview Coverdenture C/ Gingiva formers Transfer on implant level Abutments Balance Base C/ (SmartFix concept) Gingiva Former C/ D 4.2 31022510 GH 0.75 31022512 GH 1.5 31022514 GH 3.0 31022516 GH 4.5 Balance Base Abutment C/ 31022520 narrow GH 0.75 A 0 31022530 narrow GH 1.5 A 0 31022540 narrow GH 3.0 A 0 31022542 GH 3.0 A 15 31022546 GH 3.0 A 30 31022550 narrow GH 4.5 A 0 31022552 GH 4.5 A 15 31022556 GH 4.5 A 30 Snap Attachment C/ LOCATOR C/ Sulcus Former C/ Standard 31021011 a / 1.5 31021021 a / 3.0 31021026 a / 4.5 31045400 Transfer Screw C/ short 31045402 Transfer Screw C/ long 31045410 Transfer Post C/ short 31045412 Transfer Post C/ long 31045415 Repositioning Post C/ 31045416 Repositioning Post C/ narrow 31045270 Balance C/ Implant Analog A Snap Attachment C/ 31021300 GH 1.5 31021310 GH 3.0 31021320 GH 4.5 LOCATOR C/ Abutment 31022610 GH 2.0 31022612 GH 3.0 31022614 GH 4.0 31022616 GH 5.0 31022618 GH 6.0 SynCone C/ Abutment* SynCone C/ Gingiva Former C/ D 4.2 31022512 GH 1.5 31022514 GH 3.0 31022516 GH 4.5 4 GH 1.5 31021881 A 0 31021884 A 15 GH 3.0 31021882 A 0 31021885 A 15 GH 4.5 31021883 A 0 31021886 A 15 6 GH 1.5 31021891 A 0 31021894 A 15 GH 3.0 31021892 A 0 31021895 A 15 GH 4.5 31021893 A 0 31021896 A 15 5 GH 1.5 31022110 A 0 31022112 A 7.5 31022114 A 15 31022116 A 22.5 31022118 A 30 GH 3.0 31022120 A 0 31022122 A 7.5 31022124 A 15 31022126 A 22.5 31022128 A 30 GH 4.5 31022130 A 0 31022132 A 7.5 31022134 A 15 31022136 A 22.5 31022138 A 30 12 *SynCone 5 available summer 2014

C/ Transfer on abutment level, abutment analog Secondary part Accessories Screw retention 31056022 Fixation screw occlusal M 1.6 31056216 Retention coping 31056025 Fixation screw extra long 31045332 Analog 31056212 Gold Coping 31056216 Retention Coping 31056218 Titanium Coping 31045322 Wax-up Coping 31056025 Fixation Screw extra long 31022590 Protective Cap for Balance Base Abutment narrow 31056024 Fixation screw occlusal M 1.6 long 31045220* Laboratory Analog 31021312** Matrix for Snap Attachment 32453355 Impression Coping (4 pcs) 32453356 Female Analog (4 pcs) D4 32453347 Male Processing Package (Titanium) 32453348 Male Processing Package (Stainless Steel) Replacement Male (4 pcs) 32453349 clear 32453352 green 32453350 pink 32453353 orange 32453351 blue 32453354 red 32453360 gray 32453358 Processing Replacement Male (4 pcs) 32453359 Block-Out Spacer (20 pcs) 32453361 Processing Spacer (4 pcs) PROSTHETICS 31022198 Taper Cap 5 with retention 31021889 Taper cap 4 with retention 31021899 Taper cap 6 with retention 31022198 Taper cap 5 with retention 31022199 Taper cap 5 without retention 31021890 Polymerization Sleeve for 4 and 6 31021405 Polymerization Sleeve for 5 *direct impression of snap sphere **snap 31021312 included in 31021300, 1310, 1320 13

Soft tissue management and abutment assembly Transition implant-abutment displaced toward the center Some special characteristics have to be considered for soft tissue contouring and the choice of the final abutment: Due to the taper connection, the diameter of the abutments on the implant level is markedly smaller than the diameter of the implant itself. Soft tissues are also located under the flanks of the abutment. Selection of the correct gingiva height The illustration shows the correct usage of a gingiva former. If the gingival level lies in the area between the two dotted lines, the correct gingiva former has been selected. If the level is above the upper dotted line, a higher gingiva former should be selected; if it is below the lower dotted line, a lower one should be selected. Selection of the gingiva former corresponding to the abutment The gingiva former and final abutment should be selected so that they correspond in prosthetic range and gingival height. The description of the height of the gingiva former as shown above (GH 3.0) only refers to the region from the interface level to the edge of the crown. If the soft tissue passage formed is smaller than the profile of the abutment used, this may result in an avoidable compression of the gingiva. This effect occurs when: 1. The gingiva former is markedly higher than the gingival level and the abutment used later on. The entire gingiva former is always approximately 1.5 mm higher than the nominal height, viewed from the interface level (here: overall height 4.5 mm), in order also to shape the first part of the crown profile. 2. The gingiva former is suitable to the gingival height, but the gingival height of the final abutment is lower than that of the gingiva former used (see illustration). 3. The final abutment has a larger diameter then the gingiva former used (e.g. in case of a different prosthetic range). When transferring the tapered connection without index, a transfer key safeguards the exact position of the abutment in the implant. 14

Impression taking C/ (without index) implant levelc/ Balance C/ Transfer Post 6 Balance C/ Transfer Screw 6 Balance C/ Transfer Post For transferring the implant position to the master cast with the PickUp technique (open tray) short long short long Order no. 31045410 31045412 31045400 31045402 Balance C/ Repositioning Post 6 Balance C/ Repositioning Post narrow 6 Balance C/ Repositioning Post The option for procedures with closed tray Instruments Order no. 31045415 31045416 Balance C/ Implant Analog A Screwing in Transfer Screws and Repositioning Posts: By hand, Screwdriver 1.0 mm hex for loosening the screws if necessary PROSTHETICS Order no. 31045270 15

Regular C/* Crown & bridgework, wide abutments Regular C/X Gingiva Former For simple contouring of the peri-implant soft tissue Selection depends on the gingival margin Regular C/X Gingiva Former 4 GH 0.75 GH 1.5 GH 3.0 GH 4.5 Order no. 3102 4010 3102 4012 3102 4014 3102 4016 TRANSFER ON IMPLANT LEVEL: Transfer Post Balance C/ Impression Component Abutment Level / TRANSFER ON ABUTMENT LEVEL: 3-in-1 Cap as transfer cap (for angulations 0-22.5 only) Regular C/X 3-in-1 Cap For transferring the position of the prosthetic abutment when making impressions over Regular C/X abutments already placed in the implant For fabrication of a provisional restoration with snap-effect chairside (on unground abutments only) As wax-up coping on abutment analogs Regular C/X 3-in-1 Cap 20 Angulation A 0 A 7.5 A 15 A 22.5 Order no. 31047120 31047121 31047122 31047123 Regular C/X Abutment Analog For fixing the prosthetic components after the impression making with the 3-in-1 cap Regular C/X Abutment Analog 6 Angulation A 0 A 7.5 A 15 A 22.5 Order no. 31047110 31047111 31047112 31047113 Gingival heights Angulations and head heights GH 0.75 GH 1.5 GH 3.0 GH 4.5 0 7.5 15 22.5 *Impression on abutment level as an option 16

C/ Regular C/ Abutment 4 Gingival height 0.75 Regular C/ Abutment Easily adaptable to the clinical situation with four gingival heights and up to four angulations Can be customized by grinding Cementable or laterally screw-retained Tapered connection geometry for infinitely variable positioning Angulation A 0 A 7.5 A 15 A 22.5 Order no. 31024150 31024151 31024152 31024153 Gingival height 1.5 Angulation A 0 A 7.5 A 15 A 22.5 Order no. 31024160 31024161 31024162 31024163 Gingival height 3.0 Fixation Screw Lateral Hexagon M 1.4 4 Horizontal Screw Seat for Fixation Screw M 1.4 14 PROSTHETICS Angulation A 0 A 7.5 A 15 A 22.5 Order no. 31024170 31024171 31024172 31024173 31056301 31056304 Gingival height 4.5 Instruments Placing Regular C/ Abutments: Screwdriver 1.0 mm hex, recommended torque 15 Ncm Angulation A 0 A 7.5 A 15 A 22.5 Order no. 31024180 31024181 31024182 31024183 17

Balance Posterior C/ Crown & bridgework, narrow abutments Balance Posterior C/ Sulcus Former For simple contouring of the peri-implant soft tissue Selection depends on the gingival margin Balance Posterior C/ Sulcus Former 4 GH 0.75 GH 1.5 GH 3.0 GH 4.5 Instruments Placing Sulcus Formers: Screwdriver 1.0 mm hex Order no. 31021528 31021530 31021535 31021540 TRANSFER ON IMPLANT LEVEL: Transfer Post Balance C/ Gingival heights Angulations and head heights Ø 5.4 Ø 5.4 Ø 5.4 Ø 5.4 Ø 5.4 Ø 5.4 Ø 5.4 5.4 5.4 Ø 5.4 Ø Ø Ø 5.4 Ø 5.4 0.75 1.5 3.0 4.5 7.5 7.5 7.5 7.5 7.5 7.5 0.75 1.5 3.0 4.5 7.5 7.5 7.5 7.5 7.5 7.5 GH 0.75 GH 1.5 GH 3.0 GH 4.5 0 7.5 15 18

C/ Balance Posterior C/ Abutment 4 Gingival height 0.75 Angulation straight 7.5 15 Balance Posterior C/ Abutment For crowns and bridges in the posterior region Optimally adaptable to the clinical situation with four gingival heights and up to three angulations Can be customized by grinding Cementable or laterally screw-retained Tapered connection geometry for infinitely variable positioning Order no. 31021625 31021647 31021648 Gingival height 1.5 Angulation straight 7.5 15 Order no. 31021630 31021649 31021650 Gingival height 3.0 Retaining Screw Lateral Hexagon M 1 x 0.2 6 Sleeve for Retaining Screw Lateral Hexagon 14 PROSTHETICS Angulation straight 15 Order no. 31021640 31021660 31056051 31056052 Gingival height 4.5 InstrumentS Placing Balance C/ Abutments: Screwdriver 1.0 mm hex, recommended torque 15 Ncm Angulation straight 15 Order no. 31021645 31021665 Fixing the restoration with the Lateral Retaining Screw: Screwdriver 1.0 mm hex, recommended torque 10 Ncm 19

Balance Anterior C/ Anatomical abutments, anterior region Balance C/ Sulcus Former For simple contouring of the peri-implant soft tissue Selection depends on the gingival margin Balance C/ Sulcus Former 4 Screw for Sulcus Formers 4 Instruments Placing Sulcus Formers: Screwdriver 1.0 mm hex Article 1.5 small 3.0 small 1.5 large 3.0 large 1.5 3.0 Order no. 31021510 31021515 31021520 31021525 31021505 31021507 TRANSFER ON IMPLANT LEVEL: Transfer Post C/ Balance C/ Temporary Abutment For esthetically demanding temporary crowns and bridges Easily adaptable to the clinical situation with two diameters, two sulcus heights and two angulations Easy to use with groove for retention of the temporary denture Stable and x-ray visible with zirconium oxide additive Balance C/ Temporary Abutment 4/24/32 Article small / 1.5/ straight Ø 5.5 / H 6.0 small / 3.0/ straight Ø 5.5 / H 6.0 large / 1.5/ straight Ø 7 / H 7.5 large / 3.0/ straight Ø 7 / H 7.5 Please note that the maximum wearing time is 6 months. Order no. 31023311 31023316 31023351 31023356 Article small / 1.5/ 15 Ø 5.5 / H 6.5 small / 3.0/ 15 Ø 5.5 / H 6.5 large / 1.5/ 15 Ø 7 / H 7.5 large / 3.0/ 15 Ø 7 / H 7.5 Order no. 31023331 31023336 31023371 31023376 Diameters and head heights Angulations Gingival heights 1.5 3.0 5.5 7.0 6.0 7.0 1.5 3.0 5.5 7.0 6.0 1.5 3.0 1.5 3.0 5.5 7.0 6.0 7.0 Ø 5.5 Ø 7.0 Ø 5.5 Ø 7.0 0 15 GH 1.5 GH 3.0 20

C/ Balance Anterior C/ Abutment 4 Article small / 1.5/ straight Ø 5.5 / H 6.0 small / 3.0/ straight Ø 5.5 / H 6.0 large / 1.5/ straight Ø 7 / H 7.5 large / 3.0/ straight Ø 7 / H 7.5 Order no. 31021550 31021560 31021570 31021580 Balance Anterior C/ Abutment For esthetically demanding singletooth crowns and bridges in the anterior region Easily adaptable to the clinical situation with two diameters, two gingival heights and two angulations Can be customized by grinding Cementable or laterally screwretained Tapered connection geometry for infinitely variable positioning Article small / 1.5/ 15 Ø 5.5 / H 6.5 small / 3.0/ 15 Ø 5.5 / H 6.5 large / 1.5/ 15 Ø 7 / H 7.5 large / 3.0/ 15 Ø 7 / H 7.5 Order no. 31021590 31021600 31021610 31021620 CERCON Balance C/ Abutment 32/4 Article Order no. Order no. neutral dentine small / 1.5/ straight Ø 5.5 / H 6.0 small / 3.0/ straight Ø 5.5 / H 6.0 large / 1.5/ straight Ø 7 / H 7.5 large / 3.0/ straight Ø 7 / H 7.5 31023010 31023015 31023050 31023055 31023310 31023315 31023350 31023355 CERCON Balance C/ Abutment For porcelain crowns with realistic tooth analogy in the front-tooth region Extremely stable, manufactured with zirconium oxide ceramic Easily adaptable to the clinical situation with two diameters, two gingival heights and two angulations Only large abutment customizable by grinding Two shades of white, neutral and dentine Superior esthetics with brilliant light dynamics Tapered connection geometry for infinitely variable positioning PROSTHETICS Please note that the indication is restricted to single-tooth restorations in the front-tooth region. Article small / 1.5/ 15 Ø 5.5 / H 6.5 small / 3.0/ 15 Ø 5.5 / H 6.5 large / 1.5/ 15 Ø 7 / H 7.5 large / 3.0/ 15 Ø 7 / H 7.5 Order no. Order no. neutral dentine 31023030 31023035 31023070 31023075 31023330 31023335 31023370 31023375 21

Balance Base C/, SmartFix concept* Occlusal screw-retained bridges, bar Gingiva Former C/ D 4.2 4 GH 0.75 GH 1.5 GH 3.0 GH 4.5 Order no. 31022510 31022512 31022514 31022516 Protective Cap for Balance Base Abutment narrow For contouring of the peri-implant soft tissue on the Balance Base Abutment C/ narrow For covering the narrow Base Abutment in the patient s mouth during the laboratory stage Analog Balance Base Abutment narrow 4 Protective Cap for Balance Base Abutment narrow 4 Gold Coping for Balance Base Abutment (Permador PDF) 11 Order no. 31045332 31022590 31056212 Retention Coping for Balance Base Abutment narrow For simplified transfer on abutment level To be used for PickUp technique occlusal fixation screw 31056025 Retention Coping for Balance Base Abutment narrow 4 Titanium Coping for Balance Base Abutment narrow 3 Wax-up Coping for Balance Base Abutment narrow 20 Order no. 31056216 31056218 31045322 Pre-fabricated copings for Balance Base Abutment C/ For simple fabrication of prosthetic restorations without changing abutments in the patient s mouth Due to the overlapping thread, only Occlusal Fixation Screws 31056022/24/25 can be used with Copings for Balance Base Abutment narrow Abutment Head for Balance Base Abutment C/ angled (as spare part) Order no. 31022570 Angled Balance Base Abutment C/ for SmartFix concept For secure handling the abutment components are premounted on a seating instrument. Delivery of the angled Balance Base abutment is facilitated by the short and flexible seating instrument, especially when space is restricted. 22 *Impression on abutment level as an option

C/ Balance Base Abutment C/ narrow 4 Gingival height 0.75 Angulation A 0 Balance Base Abutment C/ narrow For retaining overdentures on bar constructions Also as an option for simple and straightforward fabrication of screwretained bridges Base for CAD/CAM-manufactured bar-retained overdentures and bridges For occlusal screw retention only Order no. 31022520 Gingival height 1.5 Please note: Balance Base Abutments must be used in pairs and are not suitable for cemented-in suprastructures. Single-tooth restorations are contraindicated. Angulation A 0 Order no. 31022530 Gingival height 3.0 Diameters / head- / gingival heights Ø 4.2 Ø 4.2 Angulation A 0 A 15 A 30 Order no. 31022540 31022542 31022546 1.3 GH Base Abutment C/ narrow 1.3 GH Base Abutment C/ angled PROSTHETICS Gingival height 4.5 Angulation Fixation Screw Occlusal M 1.6 mm Hex 4 A 0 A 15 A 30 Order no. 31022550 31022552 31022556 short (anodized blue) long (flush with coping) extra long (extends coping by 5 mm) Order no. 31056022 31056024 31056025 Instruments Screwing in Balance Base Abutments C/: Insert for Prosthetic Ratchet, 1.8 mm hex, recommended torque 25 Ncm Screwing in Occlusal Fixation / Retaining Screws: Screwdriver 1.0 mm hex, recommended torque 10 Ncm Finishers are available for trimming the prosthetic restoration in the laboratory. 23

SynCone C/* Edentulous jaw, prefabricated taper crowns SynCone 5 ** 5 taper angle Unified head geometry for both mandible and maxilla Independent of the number of Implants Additional angulations 7.5 for more accurate alignment in the mandible 22.5 and 30 specially designed for the maxilla All angulations available in all gingival heights for greater flexibility Parallel gauge with rotation aid Standard positioning key can be locked into the shaft to simplify alignment of the abutment with the parallel gauge Taper cap also without retention Immediately ready for cementing into metal framework Gingiva Former C/ D 4.2 4 GH 0.75 GH 1.5 GH 3.0 GH 4.5 Order no. 31022510 31022512 31022514 31022516 Impression taking: There is no impression taking when immediate loading is performed. ON HEALED IMPLANTS IMPRESSION IS TAKEN ON IMPLANT LEVEL: Transfer abutment Balance C/ When a long-term temporization is changed to the FINAL restoration, the transfer IS TAKEN ON abutment level: SynCone taper cap with retention used as transfer cap. Cover screw for straight abutment Easier than resin for covering the screw channel Gingival heights Diameter, angulations and head heights GH 1.5 GH 3.0 GH 4.5 0 15 22.5 24 *Impression on abutment level in immediate restoration **Available summer 2014

C/ SynCone C/ Abutment 4 Gingival height 1.5 Angulation A 0 A 7.5 A 15 Order no. 4 31021881 31021884 5 6 31022110 31022112 31022114 31021891 31021894 A 22.5 A 30 31022116 31022118 SynCone C/ Abutment For restoration of the edentulous mandible with an immediately loaded prosthesis on four prefabricated interforaminal taper abutments For late restoration of the mandible and maxilla as prefabricated retaining element for prostheses Straight or angled in three sulcus heights and up to five angulations Tapered connection geometry for infinitely variable positioning Gingival height 3.0 Angulation A 0 A 7.5 A 15 A 22.5 A 30 Order no. 4 31021882 31021885 5 6 31022120 31022122 31022124 31021892 31021895 31022126 31022128 Gingival height 4.5 Angulation A 0 A 7.5 Taper Cap Degulor for SynCone Abutment straight 13 with retention without retention Order no. 4 31021889 5 31022198 31022199 6 31021899 A 15 Order no. 4 31021883 31021886 5 6 31022130 31022132 31022134 31021893 31021896 Drilling Sleeve for SynCone 4 (titanium) 31025491 31045490 31025491 A 22.5 A 30 31022136 31022138 Taper Cap Degulor for SynCone C/ For abutments with 5 taper head available with retention in immediate restoration. Without retention for simplified fabrication of prostheses with metal framework in late restorations. Drilling Sleeve for SynCone Drilling Sleeve fits 2mm Twist drill, for conventional drilling templates without CT planning PROSTHETICS Parallel Gauge for SynCone 4 Polymerization Sleeve for SynCone 26 Instruments Placing SynCone C/ Abutments: Screwdriver 1.0 mm hex, recommended torque 15 Ncm Order no. 4 31033616 31021890 5 31033611 31021405 6 31033617 31021890 Parallel alignment of abutments: Parallel Gauge for SynCone 25 Note: SynCone 5 available summer 2014

Snap Attachment C/* Edentulous jaw, prefabricated retention elements Abutment with Snap Attachment C/ Overdentures in the edentulous mandible on two implants Fabrication of the restoration chairside or in the laboratory Diameter of snap sphere is 2.7 mm Abutment with Snap Attachment C/ 4 a / 1.5 a / 3.0 a / 4.5 Order no. with matrix 31021300 31021310 31021320 Order no. w/o matrix 31021301 31021311 31021321 Instruments Placing Snap Attachments: Torque Insert for Snap Attachment, recommended torque 25 Ncm Matrix for Snap Attachment 14 Silicone Ring (Spare part) Laboratory Analog 6 for Abutment with Snap Attachment Activation/deactivation of Matrix for Snap Attachment: Activation/Deactivation Instrument for Matrix for Snap Attachment Order no. 31021312 31021313 31045220 Prosthetic restorations with extremely thin gingiva components with gingival height zero For restoring cases with primarily extremely thin alveolar mucosa Sulcus Former 0.0 4 Central Screw Hex for A-implants for B-implants for C-implants for sulcus former 0.0 Order no. 31021451 31021452 31021454 31021431 Balance Posterior C/ Abutment 4 Regular C/X Implant Analog 6 0.0 / straight for A-implants for B-implants for C-implants Order no. 31021445 31047011 31047012 31047013 26 *Impression on abutment level as an option

C/ LOCATOR C/ Edentulous jaw, prefabricated retention elements LOCATOR Abutment C/ 40 GH 2 GH 3 GH 4 GH 5 GH 6 Order no. 31022610 31022612 31022614 31022616 31022618 LOCATOR C/ Full arch overdentures on two implants Self-aligning design for easy fixation in mouth with a simple click Low overall height to provide greater freedom at limited space conditions Flexible retention for individual definition of prosthesis retention and compensation of axial divergencies LOCATOR Replacement Male 41 (4 pieces) clear, strong pink, light blue, extra light extended range: gray, zero extended range: green, strong extended range: orange, light extended range: red, extra light Order no. 32453349 32453350 32453351 32453360 32453352 32453353 32453354 LOCATOR Impression Coping 42 (4 pieces) LOCATOR Male Processing Package (Contents: 2 piece each) Titanium 43 Stainless Steel 43 LOCATOR Female Analog 44 (4 pieces) D 4 Order no. 32453355 32453347 32453348 32453356 LOCATOR Black Processing Replacement Male 46 (4 pieces) LOCATOR Block-Out Spacer 47 (20 pieces) LOCATOR Processing Spacer 48 (4 pieces) LOCATOR Abutment Holder Sleeve 50 (4 pieces) Content LOCATOR Male Processing Package: 2 x Matrix 2 x Block-Out Spacer 2 x Replacement Male clear, strong retention 2 x Replacement Male pink, light retention 2 x Replacement Male blue, extra light retention Diameter and head heights PROSTHETICS Order no. 32453358 32453359 32453361 32453341 Ø 3.8 Ø 3.8 Ø 3.8 Ø 3.8 Ø 3.8 GH 2 GH 3 GH 4 GH 5 GH 6 LOCATOR Core Tool 49 4-piece Insert for Prosthetic Ratchet 6 for LOCATOR 3.5 LOCATOR Angle Measurement Guide 51 4.5 5.5 6.5 LOCATOR Parallel Post 46 (4 pieces) 7.5 LOCATOR Cap 2.3 Ø 5.5 Reduced scale Instruments Order no. 32453340 3103 3635 32453345 32453346 Placing LOCATOR Abutments: LOCATOR Core Tool, 3-piece or Insert for Prosthetic Ratchet for LOCATOR. 27

Standard C/** Crown & bridgework on abutment level Standard C/ Sulcus Former For simple contouring of the periimplant soft tissue They are selected depending on the gingival height and the planned abutment diameter a or b Standard C/ Sulcus Former 4 INSTRUMENTS Article a / 1.5 compact a / 3.0 compact a / 4.5 compact a / 6.0 compact b / 1.5 compact b / 3.0 compact Placing Sulcus Formers / Gingiva Formers: Screwdriver 1.0 mm hex Order no. 31021011 31021021 31021026 31021028 31021031 31021041 Diameter Gingival heights Angulations and head heights Ø a 3.3 Ø b 4.5 GH 1.5 GH 3.0 GH 4.5 GH 6.0 0 0 15 15 **Impression on abutment level only 28

C/ Standard C/ Abutment 4 Straight abutments Straight Standard abutments are inserted with insertion keys for a abutments or b abutments. The M 1.6 occlusal thread is for fixing the suprastructure in place. Standard C/ Abutment High flexibility with various sizes and two angulations Abutment selection chairside, the abutments remain in the patient's mouth Simplified supragingival impressions and framework try-in Cementable or screw-retained (occlusal with straight abutments, lateral with angled abutments) Article a / 1.5 / 4.0 a / 1.5 / 6.0 a / 3.0/ 4.0 a / 4.5/ 4.0 a / 6.0/ 4.0 a / 3.0/ 6.0 Order no. 31021050 31021060 31021070 31021076 31021078 31021080 Article b / 1.5 / 4.0 b / 1.5/ 6.0 b / 3.0/ 4.0 b / 3.0/ 6.0 Order no. 31021090 31021100 31021110 31021120 Angled abutments 15 Standard abutments are fixed in the correct position with a positioning key for preangled abutments and tightened by applying 15 Ncm to the straining screw. Screwdriver: 1.0 mm hexagon. The superstructures are retained by the M1 X 0.2 lateral retaining screw hexagon. PROSTHETICS Article a / 1.5 / 4.0 15 a / 1.5/ 6.0 15 a / 3.0/ 4.0 15 a / 3.0/ 6.0 15 INSTRUMENTS Order no. 31021130 31021140 31021150 31021160 Placing Standard C/ Abutments straight: Insertion Key for a and b Abutments, recommended torque 25 Ncm Placing Standard C/ Abutments angled: Screwdriver 1.0 mm hex, recommended torque 15 Ncm Article b / 1.5 / 4.0 15 b / 1.5/ 6.0 15 b / 3.0/ 4.0 15 b / 3.0/ 6.0 15 Order no. 31021170 31021180 31021190 31021200 Fixing Crowns and Bridges with the Retaining Screw Occlusal or Lateral: Screwdriver 1.0 mm hex, recommended torque 10 Ncm 29

Standard C/** Crown & bridgework on abutment level Standard TransferCap For transfer of the abutment position to the master cast Fixed on the abutment by retention, on straight abutments also with the wax-up screw long (pick-up impression with open tray) Standard TransferCap 27 a / 1.5 / 4.0 a / 3.0 / 4.0 a / 1.5 / 6.0 a / 3.0 / 6.0 b / 1.5 / 4.0 b / 3.0 / 4.0 b / 1.5 / 6.0 b / 3.0 / 6.0 1 2 Please note: With 15 abutments adjust the flat (1) side of the transfer cap in line with the lateral threads (2). Order no. 31045011 31045021 31045031 31045041 Standard Temporary Cap For simple and quick fabrication of temporary components on Standard abutments straight and angled Fabrication chairside or in the laboratory Standard Temporary Cap 20 a / 1.5 / 4.0 a / 3.0 / 4.0 a / 1.5 / 6.0 a / 3.0 / 6.0 b / 1.5 / 4.0 b / 3.0 / 4.0 b / 1.5 / 6.0 b / 3.0 / 6.0 Order no. 31045280 31045290 31045300 31045310 Standard Laboratory Analog one piece For laboratory fabrication of the implant prosthetics in the Standard system For fixing gold copings in the soldering model Standard Laboratory Analog 6 one piece Standard laboratory analogs two-piece remain available. a / 1.5 / 4.0 a / 3.0 / 4.0 straight a / 1.5 / 6.0 a / 3.0 / 6.0 straight b / 1.5 / 4.0 b / 3.0 / 4.0 straight b / 1.5 / 6.0 b / 3.0 / 6.0 straight Order no. 31045140 31045150 31045160 31045170 a / 1.5 / 4.0 a / 3.0 / 4.0 15 a / 1.5 / 6.0 a / 3.0 / 6.0 15 b / 1.5 / 4.0 b / 3.0 / 4.0 15 b / 1.5 / 6.0 b / 3.0 / 6.0 15 Order no. 31045142 31045152 31045162 31045172 30 **Impression on abutment level only

C/ Standard Wax-up Coping 20 straight & 15, for single crowns with interior grooves a / 1.5 / 4.0 a / 3.0 / 4.0 a / 1.5 / 6.0 a / 3.0 / 6.0 b / 1.5 / 4.0 b / 3.0 / 4.0 b / 1.5 / 6.0 b / 3.0 / 6.0 Standard Wax-up Coping For waxing single-tooth crowns for straight and angled Standard abutments Occlusal and lateral holes for screwretained suprastructures Ribs for rotation locking Also for cemented restorations Order no. 31045180 31045190 31045200 31045210 Standard Wax-up Coping Bridge 20 straight & 15, for bridges without interior grooves Standard Wax-up Coping Bridge For fabrication of bridges for straight and angled Standard abutments Occlusal and lateral holes for screwretained superstructures Also for cemented restorations a / 1.5 / 4.0 a / 3.0 / 4.0 a / 1.5 / 6.0 a / 3.0 / 6.0 b / 1.5 / 4.0 b / 3.0 / 4.0 b / 1.5 / 6.0 b / 3.0 / 6.0 Order no. 31045182 31045192 31045202 31045212 Standard Gold Coping Degunorm 12 a / 1.5 / 4.0 a / 3.0 / 4.0 Standard Gold Coping Permador 14 a / 1.5 / 6.0 a / 3.0 / 6.0 b / 1.5 / 4.0 b / 3.0 / 4.0 b / 1.5 / 6.0 b / 3.0 / 6.0 Order no. 31056160 31056170 31056180 31056190 Standard Gold Coping For fabrication of bar restorations on straight Standard abutments For soldering from the high-gold content precious metal alloy Degunorm Cast-to from the precious metal alloy Permador PROSTHETICS a / 1.5 / 4.0 a / 3.0 / 4.0 a / 1.5 / 6.0 a / 3.0 / 6.0 b / 1.5 / 4.0 b / 3.0 / 4.0 b / 1.5 / 6.0 b / 3.0 / 6.0 Order no. 31056100 31056110 31056120 31056130 Fixation Screw Occlusal, short 4 Retaining Screw Lateral Hexagon M 1 x 0.2 6 Sleeve for Retaining Screw Lateral Hexagon 14 Screw for Gold Coping 1.6 mm 4 INSTRUMENTS Fixing crowns and bridges with the Fixation Screw Occlusal or Lateral: Screwdriver 1.0 mm hex, recommended torque 10 Ncm Order no. 31056022 31056051 31056052 31056140 Fixing bars with the Screw for Gold Coping: Screwdriver 1.6 mm blade, recommended torque 10 Ncm 31

Prosthetic concepts /X (with index) overview Crown & bridgework Gingiva formers / sulcus formers Transfer on implant level Regular /X Regular C/X Gingiva Former 31024010 GH 0.75 31024012 GH 1.5 31024014 GH 3.0 31024016 GH 4.5 31047040 Transfer Post Pick-Up short 31047042 Transfer Post Pick-Up long 31047044 Repositioning Post short 31047046 Repositioning Post long 31047011 Regular C/X Implant Analog A 32

/X Abutments Transfer on abutment level, abutment analog Accessories Screw retention 3105 6301 Fixation Screw Lateral Hexagon M 1.4 Regular X/ 31024110 GH 0.75 A 0 31024120 GH 1.5 A 0 31024130 GH 3.0 A 0 31024140 GH 4.5 A 0 31024111 GH 0.75 A 7.5 31024121 GH 1.5 A 7.5 31024131 GH 3.0 A 7.5 31024141 GH 4.5 A 7.5 31024112 GH 0.75 A 15 31024122 GH 1.5 A 15 31024132 GH 3.0 A 15 31024142 GH 4.5 A 15 31047120 Regular C/X 3-in-1 Cap A 0 31047110 Regular C/X Abutment Analog A 0 31047121 Regular C/X 3-in-1 Cap A 7.5 31047111 Regular C/X Abutment Analog A 7.5 31047122 Regular C/X 3-in-1 Cap A 15 31047112 Regular C/X Abutment Analog A 15 3105 6304 Horizontal Screw Seat for Fixation Screw M 1.4 31024113 GH 0.75 A 22.5 31024123 GH 1.5 A 22.5 31024133 GH 3.0 A 22.5 31024143 GH 4.5 A 22.5 31047123 Regular C/X 3-in-1 Cap A 22.5 31047113 Regular C/X Abutment Analog A 22.5 PROSTHETICS 33

Soft tissue management and abutment assembly Transition implant-abutment displaced toward the center Some special characteristics have to be considered for soft tissue contouring and the choice of the final abutment: Due to the taper connection, the diameter of the abutments on the implant level is markedly smaller than the diameter of the implant itself. Soft tissues are also located under the flanks of the abutment. Selection of the correct gingiva height The illustration shows the correct usage of a gingiva former. If the gingival level lies in the area between the two dotted lines, the correct gingiva former has been selected. If the level is above the upper dotted line, a higher gingiva former should be selected; if it is below the lower dotted line, a lower one should be selected. Selection of the gingiva former corresponding to the abutment The gingiva former and final abutment should be selected so that they correspond in prosthetic range and gingival height. The description of the height of the gingiva former as shown above (GH 3.0) only refers to the region from the interface level to the edge of the crown. If the soft tissue passage formed is smaller than the profile of the abutment used, this may result in an avoidable compression of the gingiva. This effect occurs when: 1. The gingiva former is markedly higher than the gingival level and the abutment used later on. The entire gingiva former is always approximately 1.5 mm higher than the nominal height, viewed from the interface level (here: overall height 4.5 mm), in order also to shape the first part of the crown profile. 2. The gingiva former is suitable to the gingival height, but the gingival height of the final abutment is lower than that of the gingiva former used (see illustration). 3. The final abutment has a larger diameter then the gingiva former used (e.g. in case of a different prosthetic range). When using indexed abutments, the index serves as an aid for placement in six possible positions. However, for reasons of easier handling, we recommend the usage of a transfer key. 34

/X Impression taking /X (with index) implant level /X Transfer Post 6 (PickUp Technique) with screw extension 24 PickUp Screw Extension (10 pieces) spare part /X Transfer Post For transferring the implant position to the master cast with the PickUp technique (open tray) short long Order no. 31047040 31047042 31047048 Regular C/X Transfer Post 6 (Repositioning Technique) Regular C/X Transfer Post (Repositioning Technique) For transferring the implant position to the master cast with the repositioning technique (closed tray) short long Order no. 31047044 31047046 Instruments Placing all Transfer Posts: Screwdriver 1.0 mm hex PROSTHETICS Regular C/X Implant Analog 6 A C/X Implant Analog For fixing the prosthetic components in the master cast Order no. 31047011 35

Regular /X* Crown & bridgework, wide abutments Regular C/X Gingiva Former For simple contouring of the peri-implant soft tissue Selection depends on the gingival margin Regular C/X Gingiva Former 4 GH 0.75 GH 1.5 GH 3.0 GH 4.5 Order no. 31024010 31024012 31024014 31024016 TRANSFER ON IMPLANT LEVEL: Repositioning Post /X TRANSFER ON ABUTMENT LEVEL: 3-in-1 Cap as transfer cap (for angulations 0-22.5 only) Regular C/X 3-in-1 Cap For transferring the position of the prosthetic abutment when making impressions over Regular C/X abutments already placed in the implant For fabrication of a provisional restoration with snap-effect chairside (on unground abutments only) As wax-up coping on abutment analogs Regular C/X 3-in-1 Cap 20 Angulation A 0 A 7.5 A 15 A 22.5 Order no. 31047120 31047121 31047122 31047123 Regular C/X Abutment Analog For fixing the prosthetic components after the impression making with the 3-in-1 cap Regular C/X Abutment Analog 6 Angulation A 0 A 7.5 A 15 A 22.5 Order no. 31047110 31047111 31047112 31047113 Gingival heights Angulations and head heights GH 0.75 GH 1.5 GH 3.0 GH 4.5 0 7.5 15 22.5 *Impression on abutment level as an option 36

/X Regular /X Abutment 4 Gingival height 0.75 Regular /X Abutment Easily adaptable to the clinical situation with four gingival heights and up to four angulations Can be customized by grinding Cementable or laterally screw-retained Available indexed or with tapered connection geometry Angulation A 0 A 7.5 A 15 A 22.5 Order no. 31024110 31024111 31024112 31024113 Gingival height 1.5 Angulation A 0 A 7.5 A 15 A 22.5 Order no. 3102 4120 3102 4121 3102 4122 3102 4123 Gingival height 3.0 Fixation Screw Lateral Hexagon M 1.4 4 Horizontal Screw Seat for Fixation Screw M 1.4 14 PROSTHETICS Angulation A 0 A 7.5 A 15 A 22.5 Order no. 31024130 31024131 31024132 31024133 31056301 31056304 Gingival height 4.5 Instruments Placing Regular /X Abutments: Screwdriver 1.0 mm hex, recommended torque 15 Ncm Angulation A 0 A 7.5 A 15 A 22.5 Order no. 31024140 31024141 31024142 31024143 Fixing the restoration with the Lateral Fixation Screw (only A 30 and 37.5): Screwdriver 1.0 mm hex, recommended torque 10 Ncm 37

ATLANTIS patient-specific CAD/CAM prosthetic solutions for abutments, bars and bridges For a more natural result, ATLANTIS patient-specific CAD/CAM abutments are uniquely designed using ATLANTIS VAD (Virtual Abutment Design) software and manufactured using a state-of the art milling process. ATLANTIS abutments are available in titanium, gold-shaded titanium and zirconia. ATLANTIS ISUS implant suprastructures are produced using the latest developments in CAD/CAM technologies, and are supported by computer based industrial and medical device expertise. ATLANTIS ISUS implant suprastructures are available in titanium and cobalt-chrome. The ATLANTIS order is entered in the ATLANTIS WebOrder: www.atlantisweborder.com. For further information please contact your local DENTSPLY Implants representative. 38

39 PROSTHETICS

Surgical instruments Drills Ø 3.5 mm 6.6/8 9.5 11 14 17 A6.6 A8 A9.5 A11 A14 A17 Ø 4.5 mm 6.6/8 9.5 11 14 17 B6.6 B8 B9.5 B11 B14 B17 Conical Reamers = Try-in Implants (length in mm) * * Ø 5.5 mm 6.6/8 9.5 11 14 17 C6.6 C8 C9.5 C11 C14 C17 * * Ø 7.0 mm 8 9.5 11 14 D8 D9.5 D11 D14 Round Drill Twist Drill (pilot drilling) Tri-Spade Drill for A-implants Tri-Spade Drill for B-implants Tri-Spade Drill for C-implants Parallel Drill for D-implants Conical Reamers Tap * manual preparation only Round Drill 6 * Lindemann Drill* Twist Drill 6 * Parallel Gauge for Lindemann Drill for Twist Drill Drill Extension** Extension Instrument HXSS Scale 1:1 * With internal irrigation ** The drill extension must always be used with the long internal irrigation tube (Order no. 32905043). Order no. Ø 3 mm 31033010 l = 8 mm 31033015 l = 11 mm 31033020 Ø 2 mm 31033022 31033025 Ring marking 31033026 32910003 31037408 40