Industrial Electrician V3 PVELEC26_03



Similar documents
National Craft Assessment and Certification Program S P E C I F I C A T I O N S

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

MASTER ELECTRICIAN CODE EXAMINATION EXAMINATION REFERENCE MATERIAL AND CONTENT OUTLINE. Answers to sample questions: CONTENT OUTLINE

Fig. 1 Analogue Multimeter Fig.2 Digital Multimeter

DC Circuits (Combination of resistances)

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

Electric Service Guide for Commercial Construction

NOTE ON PERFORMANCE TESTING

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

Example ESD Control Program Document Based on ANSI/ESD S

51 Ford 8N 6 to 12 Volt Conversion Side Mount Distributor

Electrical Grounding. Appendix C

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

Test Code: 8094 / Version 1

Photovoltaic Cell: Converting Light to Electricity

PHYSICS 111 LABORATORY Experiment #3 Current, Voltage and Resistance in Series and Parallel Circuits

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES

AMERBRITE UNDERWATER WHITE LED POOL LAMP

Unit: Charge Differentiated Task Light it Up!

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

8146/5 Series Breaker Panelboards

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Tristan s Guide to: Solving Parallel Circuits. Version: 1.0 Written in Written By: Tristan Miller Tristan@CatherineNorth.com

JOURNEYMAN CLASS DESCRIPTIONS

AP Physics Electricity and Magnetism #4 Electrical Circuits, Kirchoff s Rules

HP Designjet L65500 printer series Site preparation checklist (second edition)

Time Propane Pressure Drop Test Sign-Off Sheet

Job Site Electrical Safety A Matter of Life and Death

TubeTrace, ThermoTube

The Do s and Don ts of Pressure Transducers

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

McCann Technical High School Electricity Program Curriculum Grades 9 12

Current Probes. User Manual

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS WHITE PAPER BULLETIN 1497, 1497A, AND 1497B

Line Loss WSDOT Winter 2008 BZA

Lab 3 - DC Circuits and Ohm s Law

Type SA-1 Generator Differential Relay

SnoTrace KSR Surface Snow and Ice Melting INSTALLATION PROCEDURES

Ground Resistance Clamp On Tester

Mobile Crane Operator Certification Program

Experiment #5, Series and Parallel Circuits, Kirchhoff s Laws

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Fiber Optic Cable Installation

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

880 HYDRAULIC BENDER

PERMIT APPLICATION REQUIREMENTS FOR RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEMS

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Hand Crank Generator (9 May 05) Converting a Portable Cordless Drill to a Hand Crank DC Generator

Title: Grounding and Bonding Rev-01

GT Sensors Precision Gear Tooth and Encoder Sensors

OHM S LAW AND RESISTANCE

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Equipment: Power Supply, DAI, Transformer (8341), Variable resistance (8311), Variable inductance (8321), Variable capacitance (8331)

The U.S. Department of Labor projects that electrician careers will grow to 698,200 by 2022.

Weight Measurement Technology

FOR ELECTRICIAN: INSIDE WIREMAN, TECHNICIAN CABLE SPLICER SANTA CLARA COUNTY

Applying Basic Electricity Principles to Service Propane Appliances (Updated 11/2012) Performance-Based Skills Assessment Evaluation Packet

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

TC Series Hydraulic Brake ABS System

Electrical Fundamentals Module 3: Parallel Circuits

A99B Series Temperature Sensors

Tristan s Guide to: Solving Series Circuits. Version: 1.0 Written in Written By: Tristan Miller Tristan@CatherineNorth.com

Physics 3330 Experiment #2 Fall DC techniques, dividers, and bridges R 2 =(1-S)R P R 1 =SR P. R P =10kΩ 10-turn pot.

November Stray Voltage Test Procedure for Electrical Contractors

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

XL PREMIUM OIL COOLER KIT

EZ-Steer Assisted Steering System

id led 4" square housing FL44

INSTALLATION & OPERATING INSTRUCTIONS

Wire types and sizes

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

CSA Z32 TESTING GUIDELINE AND PROCEDURES

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES

Ground Resistance Clamp-On Tester

Chapter 9. Bonding and Grounding

The 2N3393 Bipolar Junction Transistor

TC Grounding and Bonding for Telecommunications Systems

Experiment NO.3 Series and parallel connection

Electric Heat Tracing INSTALLATION PROCEDURES

Hyperlinks are Inactive

Test Before Touch Easier Said Than Done. Ken Crawford, DuPont Kent Haggerty, Dupont

Resistance, Ohm s Law, and the Temperature of a Light Bulb Filament

Best Methods for Safe Hipot Testing

Byonics Micro Trak 1000 High Altitude Balloon Tracker

TEGAM Test Leads Work With Most Manufacturers Four-wire Ohmmeters

WORLDWIDE. GW400k SERIES MAINTENANCE MANUAL PROVEN PERIMETER PROTECTION

Testing Accessories. Test PaddleS. Insulated Socket Wrench Jumper Strips Test Lead Kit. Test Paddle Attachment Clips Plugs Binding Posts

Environmental Monitoring with Sensors: Hands-on Exercise

ACL 395 Resistivity Meter

RayClic Connection System Installation Instructions

EZ-Steer Assisted Steering System Installation Instructions Platform Kit P/N

Martin County Amateur Radio Association. Nightfire Kits 1 LED Torch Kit Contents. Description

Transformer circuit calculations

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Department of Labor and Industry Electrical Licensing

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Transcription:

Performance Verification Packet Industrial Electrician V3 PVELEC26_03 Performance verification tasks will be processed by within five business days, after submission by the administrator. Check with your administrator with any questions regarding submission or approval.

Performance Verification Form How to fill out and file your information Participant 1) Print your last name, first name, and social security number. 2) Print your company name, current employer, and the state where your employer s main office is located. 3) In the space provided for Participant Signature, sign your name and enter the date you signed the form. Performance Evaluator 1) In the space provided for Site Code, enter the postal zip code of the location where the performance verification is being conducted. 2) In the column provided for "Date," enter the date the participant completed each of the tasks. This date is important because there may be times a participant does not complete a performance verification in one day. 3) In the space provided for Performance Evaluator," sign your name. 4) In the space provided for Date," next to your signature, list the date the participant successfully completed all of the tasks. Administrator 1) In the space provided for Administrator, sign your name. Your signature indicates that the performance evaluator is certified to conduct this performance verification and that it was conducted within the guidelines of the. 2) In the space provided for Date, next to your signature, list the date that this performance verification form is being sent to the for entry into the National Registry. 3) In the space provided for Accredited Assessment Center, print the name of the accredited assessment center that is conducting this performance verification. 13614 Progress Boulevard Alachua, FL 32615 P 888.622.3720 www.nccer.org

Date Completed Task To Perform - - 1. Conduit Bending (Task A) 15" rise ± ½" 90 ± 5 90 is vertical Offset rise ± ½" No dogleg in offset bend Offset goes over obstacle - - 2. Conduit Bending (Task B) All angles are 90 degrees No offsets in bends Conduit / fixtures connected properly Conduit Properly secured to surface - - 3. Using Test Equipment Test leads connected properly Selector switch correctly set Voltage, resistance and current values recorded correctly Megger zeroed on first attempt PERFORMANCE EVALUATOR CHECKLIST INDUSTRIAL ELECTRICIAN - - 4. Identify Fittings Twelve (12) of fifteen (15) fittings correctly identified (spelling is not critical) - - 5. Wire Transformer ALL wires must be connected in proper location - - 6. Connect Start/Stop Station to Starter ALL wires connected according to schematic - - 7. Pack/Seal a Hazardous Location Fitting Fitting does not leak - - 8. Safety Used PPE Practiced good safety procedures 13614 Progress Boulevard Alachua, FL 32615 P 888.622.3720 www.nccer.org

PERFORMANCE VERIFICATION CANDIDATE SUMMARY INDUSTRIAL ELECTRICIAN Objective The candidate will demonstrate the ability to bend rigid conduit, use a volt OHM milliampere meter (VOM), wire a transformer, connect a motor starter, seal a fitting and identify common fittings. The candidate must complete these key tasks within four hours to be successful. Scope This Performance Verification provides a means to observe and evaluate competencies in the following areas: Conduit bending Use of electrical test equipment Identifying fittings Wiring a transformer Connecting a motor starter Packing/Sealing a hazardous location fitting Materials Required Appropriate Personal Protective Equipment Minimum 25 of ¾" rigid metallic conduit Conduit bender Conduit cutting and threading equipment Volt OHM Milliamp Meter (VOM) with leads Megger with leads Resistor or other device of known value Fitting (15 different common boxes or fittings, such as: EYD seal, EYE seal, LB conduit fitting, GUAT fitting, Union, spring nut, etc.) Transformer 13614 Progress Boulevard Alachua, FL 32615 P 888.622.3720 www.nccer.org

PERFORMANCE VERIFICATION CANDIDATE SUMMARY INDUSTRIAL ELECTRICIAN Materials Required (continued) (A) Single phase 480-120/240 or three phase 480-120/208 Wire Labeled Primary Labeled Secondary Labeled Grounded Labeled Grounding or Bonding Unlabeled (Any type of termination may be used even alligator clips) Conductor #14 cable with alligator clips (Use appropriate number of wires for task) 4 jumper wires with alligator clips 3 wire start/stop station Starter Wire labels or number pack Hazardous location seal and packing kit (1") also; 2 conduit nipples GFCI-protected power source Time Required Four hours performance, including clean-up. 13614 Progress Boulevard Alachua, FL 32615 P 888.622.3720 www.nccer.org

Last Updated: September, 2014 13614 Progress Boulevard Alachua, FL 32615 P 888.622.3720 www.nccer.org

Candidate information PERFORMANCE VERIFICATION FORM INDUSTRIAL ELECTRICIAN ELEC26_03 - CRAFT Last Name First Name Social Security Number Employer/Company Name State Code Evaluator Last Name First Name Social Security Number Task TASK Number 01 Conduit Bending (Module 26204-11) DATE (MM/DD/YY) START TIME END TIME 02 Conduit Bending (Module 26204-11) 03 Using Electrical Test Equipment (Module 26112-11) 04 Identify Fittings (Module 26205-11) 05 Wire a Transformer (Module 26307-11) 06 Connect Three-wire Start/Stop Station (Module 26311-11) 07 Pack/Seal a Hazardous Locating Fitting (Module 26304-11) 08 Safety (Module 26102-11) Consent/Release: I, the undersigned, do hereby authorize the National Center for Construction Education and Research () to release the information and results attained through the administration of the National Craft Assessment and Certification Program (NCACP) to the organization referenced below, and acknowledge that the employer noted above is my present employer. Accredited Assessment Center: Participant: Performance Evaluator: Administrator: Date: Date: Date: Last Updated: September, 2014 Return Completed Form to: Registry Department 13614 Progress Boulevard Alachua, FL 32615 P 888.622.3720 www.nccer.org