Digital Pressure Measuring Instrument MDR480



Similar documents
Panel Meters and Controllers Modular Panel Meter Type EDM 35

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Preset Counter signo 721

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

DPI 260 SERIES: Digital Pressure Indicators

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Absolute Rotary Encoder E6CP

Speed Control Relays SX2

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Electronic Pressure Switch EDS 300

Modular I/O System Analog and Digital Interface Modules

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Contents. Document information

Quick Connect. quick - simple - efficient.

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Voltage Regulator SPAU 341 C. Product Guide

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Pressure transmitter For general industrial applications Model A-10

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Short information Parameters are programmed via front-side membrane keypad

Safety technique. Emergency stop module BO 5988 safemaster

Vario-Series Accessories

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Thermal-Magnetic Circuit Breaker M1-..

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

E-STOP relays, safety gate monitors

Thermistor motor protection

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

LUT Luminescence scanners: Seeing what no-one else can

Electronic Pressure Switch EDS 3000

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

48 SERIES Relay interface modules 10 A

ACS-30-EU-EMDR-10-MOD

DS 600. A contact free flux gate based current measurement sensor 600A rms

MAGTROL. DSP6001 High-Speed Programmable Dynamometer Controller. DSP6001 Data Sheet FEATURES APPLICATIONS MOTOR TESTING SOFTWARE DESCRIPTION

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

SIMADYN D Digital Control System. Interface module SE21.2. User Manual. Edition DK-Nr

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Power Supplies 3. SDN-P DIN Rail Series

Incremental Rotary Encoder E6B2

MINI MCR-SL-R-UI(-SP)

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

PIEZOMETER AIRFLOW MEASURING RING

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Digital display DA 48

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Nokeval. User's Manual Models 301 / 302 / 305

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Three-phase monitoring relay CM-PFE

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Conductive Level Switch FK 2 Technical Data:

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Safety Relays ESM/ESM-F

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

RM4TG20 three-phase network control relay RM4-T - range V

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DCS Input/Output Relay Card Series

PSR The compact range Description

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

Digital input modules

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Transcription:

Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm x 48 mm and a mounting depth of 166 mm. It is available with a 1/2 digit 7Segment LED display covering various measuring ranges. An auxiliary voltage of /25 ma, physically isolated from the measuring input, is provided to a pressure. The resistance bridges (sensors) may be directly fed by applying a constant voltage (U ref) of 10 V or a constant current (Iconst) of 1 ma. The input range for standard signals and the display range (initial value, full scale range and decimal point) may be selected by internal jumpers and adjusted by means of the potentiometer accessible from the front. Different voltages allow a wide spread of applications. The instrument is also available with optional analogue, or with two setpoints with s. A Hold input is included as standard. MDR480 Measuring ranges Measuring Input Overload protection Pin designation range resistance cont. 5 sec Standard signal from pressure s 0...5/10 V or 0/4...20 ma 5/10 V 20 MΩ 500 V 1 2 20 ma 10 Ω 160 ma 00 ma 4 Pressure sensors (strain gauge sensors/solidstate sensors) 20 mv...200 mv* 880 kω 150 V 1 2 *The measuring range is a function of the sensor sensitivity (in mv/v). Please specify this value when ordering. Standard display ranges for pressure (in bar): 0...250 0...1000 200...1000 0...400 0...1600 00...1500 0...600 0...1999 and decimal multiples (set decimal points as required) Adjustable display: Full scale range: 200...000 digits (= final value inital value) Initial value: 1000...1000 Decimal point: selectable Please specify measuring unit when ordering. Technical data Accuracy of display (at 2 C) 0.1 % of reading ± 1 digit Input: potentialfree differential input commonmode range ± 1 V commonmode rejection >60 db Display: Red 7segment LED display 1/2 digit 1 mm high Full scale range: ± 1999 digits Overrange indication: The last digits will extinguish Hold signal via teral strip on the rear Reading characteristics: Integrating dualslope Count rate: 2.5 readings/s Setting time for a 100 % reading change: < s Sensor voltage Output physically isolated from the signal input and voltage. Overload protection: shortcircuit proof Auxiliary voltage for the electronic (standard): Voltage: DC ± 10 % Current: 25 ma Residual ripple: 0.5 % Terals: 5() and 6() Connection of resistance bridges (strain gauge sensors, piezoresistive sensors, etc.): Constant voltage: U ref = 10 V Bridge resistance: 0 Ω or Constant current: I const = 1 ma Environmental requirements Temperature drift: 0.01 % span/k (span = full measuring range) Warmup to full accuracy: 15. Operating temperature range: 0...50 C Storage temperature range: 20...70 C Applications class: KWF to DIN 40 040 Relative humidity: 0...75 % annual average, 95 %. (without condensation) Shock test: 10 g (11 ms), to IEC 68229/DIN 40 046 part 26, x shocks in planes Vibration test: on duty: 2 g (0.15 mm), 10...55 Hz on transport: 5 g (0.5 mm), 10...150 Hz to IEC 6826/DIN 40 046, page 8 Voltage (voltage rating): AC 20 V ±10 % 48...62 Hz other voltages: AC 240 V, 120 V, 115 V ±10 % 48...62 Hz (optional) AC 48 V, ±10 % 48...62 Hz DC 12 V...28 V (physically isolated) Max. allowed residual ripple 10 %, but not less than the imum voltage or more than the imum voltage. Power consumption: 8 VA/6.5 W 05/06 www.eta.com 201

Connector pin assignment Case 1 inputs s K H 2 4 5 6 7 8 OV 9 rated voltage N L1 AC DC Fig. 1 Side view Fig. 2 166 96 6.54.78 145 5.71 Front view 10 V 5 V 20 ma U ref I const Hold bridge 48 1.89 Connection of s (5) (.197) mounting bracket 2 conductor circuit, current: 4 20 ma 1 2 4 5 6 7 4 20 ma Fig. Option 1 2 4 5 6 7 8 9 Rear view Fig. 4 4. 0. 1.71.012 92. 0..6.012. R1.09 Panel cutout 8.15 conductor circuit, voltage: 0/1 5 V or 0/2 10 V 1 2 4 5 6 7 0/1 5 V, 0/2 10 V 1 2 4 5 6 7 0/4 20 ma conductor circuit, current: 0 20 ma or 4 20 ma teral strips This is a metric design and millimeter dimensions take precedence ( mm ) inch 8.15. 4.157 Caution: If several instruments are to be fitted, a imum of 8 mm between each cutout must be provided for correct removal of front glass (fig. 4). Case material: glassfibre reinforced black Noryl SE 1 Degree of protection: IP 50 (front), IP 20 (rear) Applicable specification: VDE 0411 part 100 Pollution degree to IEC 664 and 664 A Mass: approx. 500 g (without option) 4 conductor circuit, voltage: 0/1 5 V or 0/2 10 V 1 2 4 5 6 7 0/1 5 V, 0/2 10 V Terations Plugin screwteral strip for. 1.5 mm 2 cables. 4 conductor circuit, current: 0 20 ma or 4 20 ma 1 2 4 5 6 7 0/4 20 ma Connection of resistance bridges 1 2 4 5 6 7 U const /I const resistance bridge U signal 202 www.eta.com 05/06

012456789AB C DEF Options for Pressure Measuring Instrument MDR480 Analogue (AA and AB options) 2 Setpoints (option G1) Description The pressure measuring instrument accepts a current and a voltage analogue.the voltage is a differential which depends on the negative voltage; the current is groundrelated. There is no physical isolation between the analogue s and the measuring input. Technical data Current : Output current: 0...20 ma corresponding to a 0...100 % measuring range or 4...20 ma corresponding to a 0...100 % measuring range Load resistance: R L 00 Ω Voltage : Output voltage: 0...10 V corresponding to a 0...100 % measuring range Load resistance: R L 10 kω Overload protection: continuous shortcircuit or no load Caution! Do not electrically connect the inputs and s simultaneously when several instruments with analogue s are connected, as this will cause ground loops shortcircuiting the internal across the analogue s. Otherwise provide additional interface couplers with physical isolation at the s. Terations: 12pole plugin screwteral strip for. 1.5 mm 2 cables Setting the setpoints (after removal of front glass) display test Switch position or 8 1 or 9 or B All other switch positions Setting accuracy: Accuracy of response: Hysteresis: Response: Switching performance (here deenergized = selfprotection) Readout measuring value overflow selector switch to set the setpoints = accuracy of readout 0.2 % span ± 1 digit 0.5 % span ± 1 digit ca. 0.5 s OFF ON Connector pin assignment ON OFF voltage current alarm acceptable range alarm U U I I 6 5 4 2 1 0 29 28 27 26 25 measured value All switching conditions are inverted with deenergized. Three LEDs indicate the switching position of the setpoints: Rear view with analogue option: lighted: above. limit () (red LED) analogue terals lighted: acceptable range (green LED) 6 5 4 2 1 0 29 28 27 26 25 1 2 4 5 6 7 8 9 lighted: below limit () (red LED) Connector pin assignment: 2 setpoints terals for signal s, voltage Setpoints Description The instrument may be fitted with setpoints. The setpoints are with s to provide physical isolation. The response threshold may be set with a potentiometer after removing the front glass. Fadein reading of the set values with a selector switch accessible from the front. 24 2 22 21 20 19 18 17 16 15 14 1 Contact position shown in the acceptable range condition with version deenergized. Outputs: Switching capacity : 2way contact 250 V/ A/660 VA/100 W : 2way contact 250 V/ A/660 VA/100 W Terations: 12pole plugin screwteral strip for. 1.5 mm 2 cables. 05/06 www.eta.com 20

Options for Pressure Measuring Instrument MDR480 2 Setpoints Analogue 2 setpoints analogue 0...20 ma 2 setpoints analogue 4...20 ma 2 setpoints analogue 0...10 V See page 20 for setpoint description Analogue : The voltage or current analogue is designed as a differential which depends on the internal negative voltage; the current is ground related. There is no physical isolation between the analogue and the measuring input. Current : Output current 0...20 ma corresponding to a 0...100 % measuring range or 4...20 ma corresponding to a 0...100 % measuring range Load resistance R L 00 Ω Voltage : Output voltage 0...10 V corresponding to a 0...100 % measuring range Load resistance: RL 10 kω Overload protection: continuous shortcircuit or noload Caution! Do not electrically connect the inputs and s simultaneously when several instruments with analogue s are connected, as this will cause ground loops shortcircuiting the internal across the analogue s. Otherwise provide additional interface couplers with physical isolation at the s. Terations: 12pole plugin screwteral strip for. 1.5 mm 2 cables. Connector pin assignment: voltage current U U I I 24 2 22 21 20 19 18 17 16 15 14 1 Contact position shown in the acceptable range condition with version deenergized. Rear view: 2 setpoints and analogue analogue terals setpoint terals 24 2 22 21 20 19 18 17 16 15 14 1 1 2 4 5 6 7 8 9 terals for signal s, voltage 204 www.eta.com 05/06

Selector chart Please select the required type by following the chart below. Function: Housing: Display: MDR480 Digital measuring instrument pressure 96 mm x 48 mm (.78 in. x 1.89 in.) 1/2 digits Input: standard input 0 5 V, 0 10 V, 1 5 V, 2 10 V, 0 20 ma, 4 20 ma straingauge sensor solid state sensor Measuring range: Decimal point: 0 250 0 400 0 600 0 1000 0 1600 0 1999 200 1000 00 1500 special range 1999 199.9 19.99 1.999 Marking (unit): bar mbar kpa psi N/m 2 N/mm 2 without unit special marking Power : (rated voltage) AC: 240 V, 20 V 120 V, 115 V 48 V, DC: 12 V 28 V special calibration / marking OEM branding Options: analogue 0 10 V 0 20 ma 4 20 ma 2 setpoints 1) 2 1) setpoints deenergized energized deenergized energized analogue 0 10 V analogue 0 20 ma analogue 4 20 ma 1) internal setting IP50 Example: MDR480B 2 Z 1 A9 G7 N: Pressure measuring instrument 96 x 48 mm /.78 in. x 1.89 in., 1/2 digit, for standard signal 0 20 ma, measuring range 0.00 4.00 bar, AC 20 V, with ETA trademark 2 setpoints, internal setting, IP50, deenergized, analogue 0 10 V 05/06 www.eta.com 205

Ordering Information Type No. Physical dimension R Pressure Case 480 96 mm x 48 mm Input A standard signal 0...10 V B standard signal 0...20 ma C standard signal 4...20 ma D resistance bridge,fed with constant voltage**) (U ref = 10 V) E standard signal 0...5 V F standard signal 1...5 V G standard signal 2...10 V H resistance bridge, fed with constant current**) (I const = 1 ma) X user selectable standard signal 0...5 V, 0...10 V, 0...20 ma, 4...20 ma Display 1/2 digit Measuring range 1 0...250 2 0...400 0...600 4 0...1000 5 0...1600 6 0...1999 7 200...1000 8 00...1500 0 special measuring range*) X user selectable display: initial value between 1000 and 1000 digits, full scale range between 200 and 000 digits Decimal point T 1999 H 199,9 Z 19,99 E 1,999 X user selectable decimal point Marking (unit) 1 bar 2 mbar kpa 4 psi 5 N/m 2 6 N/mm 2 9 without unit 0 special marking (see below for standard markings)*) special marking as requested by customer*) Power (rated voltage) A1 AC 240 V A AC 120 V A6 AC 48 V A7 AC A8 AC 115 V A9 AC 20 V (standard) D8 DC 12...28 V physically isolated K special measuring range*) F OEM branding*) Options AA analogue : 0...20 ma 0...10 V AB analogue : 4...20 ma 0...10 V G1 2 setpoints, internal setting, IP50 G6 2 setpoints, internal setting, IP50 analogue 0...20 ma G7 2 setpoints, internal setting, IP50 analogue 0...10 V G9 2 setpoints, internal setting, IP50 analogue 4...20 ma N Relay deenergized, standard I Relay energized MD R 480 B 2 Z 1 A9.. G7 N ordering example *) Clearly add desired specifications. **) Please indicate the signal voltage range and the bridge resistance when ordering. Standard markings: V, mv, kv, MV, A, ma, ka, kw, MW, F, C, %, % r.f., ms, Stück, Ohm, ph, µs, l, N, kn, kg, t, lbf, Ncm, Nm, m, cm, mm, km, inch, bar, mbar, Pa, hpa, psi, kg/cm 2, mmws, mws, N/m 2, N/mm 2, Hz, khz, U/, 1, sec 1, rpm, l/h, l/, kg/h, m/h, m/, m/sec, t/h All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 206 www.eta.com 05/06