Hot-swapping a power supply



Similar documents
Clustered Data ONTAP 8.3

Cloud ONTAP 8.3 for Amazon Web Services

Software Storage Platform Mixing Rules

Navigating VSC 6.0 for VMware vsphere

Clustered Data ONTAP 8.3

Clustered Data ONTAP 8.3

Storage Efficiency Express Guide For 7-Mode Administrators Learning Cluster-Mode

Configuration Examples for FAS2240 Systems

NetApp FAS/V-Series Storage Replication Adapter for Clustered Data ONTAP

Clustered Data ONTAP 8.3

Clustered Data ONTAP 8.3

Clustered Data ONTAP 8.2

OnCommand System Manager 3.1

SnapManager 8 for Microsoft SharePoint Disaster Recovery User s Guide

NetApp Storage Array Management Pack for Operations Manager 2.1

Installing the 16-port Cisco unified port expansion module in Nexus 5596 cluster switches

NetApp OnCommand Shift 1.0

NetApp E-Series Plug-in for Microsoft SQL Server Management Studio Installation Guide

SnapManager 8.1 for Microsoft SharePoint Job Monitor User s Guide

SnapManager 8.2 for Microsoft SharePoint

OnCommand Insight 7.2. Installation Guide. For Red Hat Enterprise Linux. April _B0

Logical Replication (LREP) Tool User Guide

Single Mailbox Recovery 6.1 ExtractWizard Release Notes

SnapDrive for UNIX Quick Start Guide (IBM AIX, HP-UX, Linux, Solaris )

Replacing the chassis on a FAS20xx system

NetApp AFF8080 EX Performance and Server Consolidation with Microsoft SQL Server 2014

NetApp E-Series Storage Systems Concepts for SANtricity ES Storage Manager Version 10.86

Data ONTAP DSM for Windows MPIO Release Notes

NetApp SANtricity Add-in for Microsoft SQL Server Management Studio 1.3

V-Series Systems Implementation Guide for EMC CLARiiON Storage

SGI InfiniteStorage 4000 Series and 5000 Series Concepts Guide for SANtricity ES Storage (ISSM 10.86)

SnapManager for Microsoft SharePoint Server Release Notes

NetApp OnCommand Shift 1.0 Cmdlet Reference Guide

NetApp E-Series Storage Systems Concepts for SANtricity ES Storage Manager Version 10.86

Clustered Data ONTAP 8.2

NetApp E-Series Storage Systems. Command Line Interface and Script Commands for Version 10.84

Open Source Used In Cisco Instant Connect for ios Devices 4.9(1)

NetApp AltaVault Cloud Integrated Storage 4.0

Quest vworkspace Virtual Desktop Extensions for Linux

CA Cloud Service Delivery Platform

Fibre Channel and iscsi Configuration Guide

CA Cloud Service Delivery Platform

Pulse Redundancy. User Guide

Reducing the cost of Protecting and. Securing Data. Assets. Big data, small data, critical data, more data. NetApp

CA Cloud Service Delivery Platform

SGI InfiniteStorage 4000 Series and 5000 Series Configuring and Maintaining a Storage Array (ISSM 10.86)

Config Advisor 3.2. Installation and Administration Guide

Veritas Cluster Server Getting Started Guide

Third Party Software Used In PLEK500 (Utility for Win) v1.x.xx.xxx

Cisco, Citrix, Microsoft, and NetApp Deliver Simplified High-Performance Infrastructure for Virtual Desktops

Oracle s PeopleSoft 9.0 Recruiting and Admissions Changes and Updates for CS Bundle #38

NetApp E-Series Storage Systems Initial Configuration and Software Installation. For SANtricity ES Storage Manager 10.86

SGI InfiniteStorage 4000 Series and 5000 Series Configuring and Maintaining a Storage Array Using the Command Line Interface (ISSM 10.

Dell One Identity Cloud Access Manager How to Configure vworkspace Integration

Self Help Guides. Setup Exchange with Outlook

GEO Sticky DNS. GEO Sticky DNS. Feature Description

BlackBerry Web Desktop Manager. User Guide

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Oracle s PeopleSoft 9.0 Recruiting and Admissions Changes and Updates for CS Bundle #31

SnapManager 5.0 for Microsoft Exchange Installation and Administration Guide

vcenter Management Plug-in for NetApp E-Series Storage, Version 2.4 User Guide

Open Systems SnapVault Installation and Administration Guide

Data ONTAP 7.3 Storage Efficiency Management Guide

RSA Two Factor Authentication

How To Use The Programs Of Ancient.Org

Cisco TelePresence VCR MSE 8220

RedBlack CyBake Online Customer Service Desk

ANZ TRANSACTIVE - MOBILE

QNAP Plug-in for vsphere Client: A User s Guide. Updated December QNAP Systems, Inc. All Rights Reserved. V1.0

ANZ TRANSACTIVE MOBILE for ipad

Mayfair EULA for Journal Office

BlackBerry Enterprise Server Express for IBM Domino. October 7, 2014 Version: 5.0 Service Pack: 4. Compatibility Matrix

StorTrends 3400 Hardware Guide for Onsite Support

Data ONTAP 7.3 System Administration Guide

How To Manage A System On A Pc Or Mac Or Mac (Or Mac) With A Hard Drive Or Ipnet (Or Ipnet) On A Computer Or Mac) On Your Computer Or Computer (Or Pc Or Pc Or Ipro) On

System Center Virtual Machine Manager 2012 R2 Plug-In. Feature Description

TestFlight FAQ Apple Inc.

BlackBerry Web Desktop Manager. Version: 5.0 Service Pack: 4. User Guide

Datasheet NetApp FAS8000 Series

Advanced Data Mobility To Power Your Hybrid Cloud

Fuse MQ Enterprise Broker Administration Tutorials

Meeting the Needs of the Changing Enterprise

FEM 2D Port Simulation. EMPro 2012 May 2012 FEM 2D Port Simulation

Self Help Guides. Create a New User in a Domain

BlackBerry World Storefront. Version: 4.3. User Guide

Object Level Authentication

Datasheet The New NetApp FAS3200 Series Enables Flash, Clustering to Improve IT Agility and Performance

Partners in Care Welch Allyn Connex Software Development Kit License Agreement

Transcription:

80xx systems For all operating environments Hot-swapping a power supply Hot-swapping a power supply involves turning off, disconnecting, and removing the old power supply and installing, connecting, and turning on the replacement power supply. Before you begin All other components in the system must be functioning properly; if not, you must contact technical support. About this task The power supplies are redundant and hot-swappable. To prevent system downtime, you must replace only one power supply at a time. Note: Power supplies are auto-ranging.. Removing a power supply on page. Installing a power supply on page 4 3. Completing the replacement process on page 4 Removing a power supply To remove a power supply, you must identify the one you want to remove, disconnect the power cord, and remove the power supply from the chassis. About this task Attention: You should replace the power supply within two minutes of removing it from the chassis. The system continues to function, but Data ONTAP sends messages to the console about the degraded power supply until the power supply is replaced.. Identify the power supply you want to replace, based on console error messages or through the LEDs on the power supplies. See the Hardware Platform Monitoring Guide for a description of LED behaviors. 800 PSU locations 5-08008_B0 August 05 Copyright 05 NetApp, Inc. All rights reserved. Web: www.netapp.com Feedback: doccomments@netapp.com

PSU PSU Other 80xx PSU locations PSU PSU. If you are not already grounded, properly ground yourself. 3. Turn off the target power supply and remove the power cord by completing the following substeps, using the illustration for reference: Hot-swapping a power supply

3 4 5 3 4 5 Power supply Cam handle release latch Power and Attention LED Cam handle Power cord locking mechanism a. Pinch the tab on the locking mechanism of the cable retainer clip, and then open the retainer clip. b. Slide the retainer clip off the cord. c. Unplug the power cord from the power supply and the power source. 4. Press down the release latch on the power supply cam handle, lower the cam handle to the fully open position, and then slide the power supply out of the chassis. Make sure that you support the power supply with your free hand. Removing a power supply 3

Installing a power supply To install a power supply, you must place the power supply in the chassis, secure it, and reconnect the power cord to the power source.. Make sure that the on/off switch of the new power supply is in the Off position.. If you are not already grounded, properly ground yourself. 3. Insert the replacement power supply into the chassis by aligning it with the opening and gently pushing the power supply into the chassis. Attention: The power supplies are keyed and can only be installed one way. 4. Push firmly on the power supply cam handle to seat it all the way into the chassis, and then push the cam handle to the closed position, making sure that the cam handle release latch clicks into its locked position. 5. Reconnect the power cord and secure it to the power supply using the cable retaining clip. 6. Reconnect the power supply to the power source, and then turn it on. The power supply should run with no fault LEDs lit and the green LED lit. Completing the replacement process After you replace the part, you can return the failed part to NetApp, as described in the RMA instructions shipped with the kit. Contact technical support at NetApp Support, 888-463-877 (North America), 00-800-44-63877 (Europe), or +800-800-80-800 (Asia/Pacific) if you need the RMA number or additional help with the replacement procedure. Copyright information Copyright 994 05 NetApp, Inc. All rights reserved. Printed in the U.S. No part of this document covered by copyright may be reproduced in any form or by any means graphic, electronic, or mechanical, including photocopying, recording, taping, or storage in an electronic retrieval system without prior written permission of the copyright owner. Software derived from copyrighted NetApp material is subject to the following license and disclaimer: THIS SOFTWARE IS PROVIDED BY NETAPP "AS IS" AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY DISCLAIMED. IN NO EVENT SHALL NETAPP BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. NetApp reserves the right to change any products described herein at any time, and without notice. NetApp assumes no responsibility or liability arising from the use of products described herein, except as expressly agreed to in writing by NetApp. The use or purchase of this product does not convey a license under any patent rights, trademark rights, or any other intellectual property rights of NetApp. The product described in this manual may be protected by one or more U.S. patents, foreign patents, or pending applications. 4 Hot-swapping a power supply

RESTRICTED RIGHTS LEGEND: Use, duplication, or disclosure by the government is subject to restrictions as set forth in subparagraph (c)()(ii) of the Rights in Technical Data and Computer Software clause at DFARS 5.77-703 (October 988) and FAR 5-7-9 (June 987). Trademark information NetApp, the NetApp logo, Go Further, Faster, AltaVault, ASUP, AutoSupport, Campaign Express, Cloud ONTAP, Clustered Data ONTAP, Customer Fitness, Data ONTAP, DataMotion, Fitness, Flash Accel, Flash Cache, Flash Pool, FlashRay, FlexArray, FlexCache, FlexClone, FlexPod, FlexScale, FlexShare, FlexVol, FPolicy, GetSuccessful, LockVault, Manage ONTAP, Mars, MetroCluster, MultiStore, NetApp Insight, OnCommand, ONTAP, ONTAPI, RAID DP, RAID-TEC, SANtricity, SecureShare, Simplicity, Simulate ONTAP, Snap Creator, SnapCenter, SnapCopy, SnapDrive, SnapIntegrator, SnapLock, SnapManager, SnapMirror, SnapMover, SnapProtect, SnapRestore, Snapshot, SnapValidator, SnapVault, StorageGRID, Tech OnTap, Unbound Cloud, and WAFL and other names are trademarks or registered trademarks of NetApp, Inc., in the United States, and/or other countries. All other brands or products are trademarks or registered trademarks of their respective holders and should be treated as such. A current list of NetApp trademarks is available on the web at http://www.netapp.com/us/legal/ netapptmlist.aspx. How to send comments about documentation and receive update notifications You can help us to improve the quality of our documentation by sending us your feedback. You can receive automatic notification when production-level (GA/FCS) documentation is initially released or important changes are made to existing production-level documents. If you have suggestions for improving this document, send us your comments by email to doccomments@netapp.com. To help us direct your comments to the correct division, include in the subject line the product name, version, and operating system. If you want to be notified automatically when production-level documentation is released or important changes are made to existing production-level documents, follow Twitter account @NetAppDoc. You can also contact us in the following ways: NetApp, Inc., 495 East Java Drive, Sunnyvale, CA 94089 U.S. Telephone: + (408) 8-6000 Fax: + (408) 8-450 Support telephone: + (888) 463-877 Trademark information 5