Simply complete the enclosed Warranty Form with contact details, or email us with your details and date of purchase.



Similar documents
Watts Pure Water Systems

How To Replace A Reverse Osmosis Water Tank

Installation Instructions S

RPlus. Installation & Service Manual. 5-Stage Reverse Osmosis Drinking Water System. Plus

Line to Refrigerator Ice/Water Dispenser

Thank you... Welcome to your new world of better living with water2buy s Aquasmart Reverse Osmosis water. How your Reverse Osmosis unit works

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Installation Instructions

Reverse Osmosis. Drinking Water Systems. Installation Manual

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Reverse Osmosis (RO) Drinking Water System. Product Manual

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Installation and Operation Manual

Installation Instructions

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

STABITHERM INSTALLATION & SERVICE BOOKLET

Pro-OX 7800 Iron Filter Installation & Start-Up Guide

INSTALLATION & SERVICE MANUAL

Aqua-Pure AP-RO5500 Reverse Osmosis Drinking Water Filtration System

PLUMBING CARE AND REPAIR

FLUSHOMETER - TANK SYSTEM

PURE WATER. Installation, Operation and Maintenance Manual. Kwik-Change Reverse Osmosis System Model PWROKC4. Important.

Assembly and instructions

123 Industrial Loop Road Paynesville, MN Phone:

INSTALLATION & SERVICE MANUAL

Chill 4 Hole Bath Shower Mixer

Cooling system components, removing and installing

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000

EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.

Cleaning & Sanitisation

Installation guide Nordic mixer taps. Before installing read this guide first

Approval of this procedure is provided by signatory indicated in the approval block at the footer of Page #1, for and on behalf of Jabiru Pty. Ltd.

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

Iron Air Charge 2510-SXT Installation & Start-Up Guide

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

R.O. DRINKING WATER SYSTEM MODEL

4 Stage Barracuda RO/DI Instruction & Owner s Manual

Triac Printed Circuit Board Replacement

123 Industrial Loop Road Paynesville, MN Phone:


Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

PWC-500/1000/1010/1500

Rexroth Hydraulic Pump A10VO Series User Manual

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Your safety and the safety of others are very important.

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

B150 Series Commercial Brewer. Direct Plumb Kit

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Aqua-Pure AP-RO5500 Reverse Osmosis Drinking Water Filtration System

Stenner Pump Chlorinator Installation & Start Up Guide

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Installation Instructions / Warranty


Clean Water Made Easy

TYPE E Main Valve Sizes 3 /8 through 12

OWNER S MANUAL. FOOTWORKS tm Faucet Controller. Foot Operated Faucet Control Valves for Commercial Sinks

3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For:

Inline Chlorinator Chlorine Chemical Feeder

Water Info. What is Reverse Osmosis?

Troubleshooting Guide for Dispenser Model #900172

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction

Colonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Power Cube Open Source Ecology Page 1. Power Cube. Version 4

Installation Instructions AQ-5100, AQ-5200 & AQ-5300 Under Counter Water Filter Single Stage (5100), Two Stage (5200) and Three Stage (5300) systems

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

INSTALLATION INSTRUCTIONS FOR VW MK5

Before repairing your toilet, you must determine

Installation Instructions

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

Cooling system components, removing and installing

Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet

Stainless Steel Single and Dual Circulation Kits

INSTALLATION INSTRUCTIONS BL-8704

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER

2006 HEADSHOK Service Video #1

Office Coffee WaterCare Solutions

INSTALLATION INSTRUCTIONS P-TRAP SUPPLY KIT Model: RH-3016 These instructions are a guideline for a basic installation

NESCAFÉ Solution 8/60 Beverage System. Operations Manual

BF Series Sa S n u d p Fe i r l C t l e e r a n Installation Manual -1-

Installation Instructions

VERTEX OWNERS INSTALLATION MANUAL. Water Dispenser. Water Products PureWaterCooler VERTEX WATER PRODUCTS

NITROUS TRANSFER PUMP INSTRUCTIONS

INSTALLATION MANUAL MODEL RP-100

INSTALLATION INSTRUCTIONS MK-8704

VOYAGER 570G. 744A Sprayer Control

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

7500 Pro-Ox Filter Installation & Start-Up Guide

SunMor SM-V30 Solar Water Heater Installation Manual

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Fixtures - Parts - Accessories to shampoo bowls

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

Transcription:

INSTALLATION & SERVICE GUIDE 4 STAGE UNDERSINK REVERSE OSMOSIS WITH SERVICE MODE Congratulations on your purchase of the most advanced Reverse Osmosis Water Purification system available. Part of our commitment to your continued supply of the purest drinking water available is we do the remembering for you when to replace your cartridges. Our Cartridge Reminder Service, either by email or telephone will provide you with the very best cartridges at our specially discounted wholesale prices. Simply complete the enclosed Warranty Form with contact details, or email us with your details and date of purchase. Your system comes complete with a door sticker to provide easy to access contact details and replacement date. IMPORTANT NOTE: We recommend that should you be away for periods exceeding 7 days, you turn water supply off at the stop valve. To ensure correct operation of your Reverse Osmosis unit, water supply must be within the following specifications MODELS WITH PA (TFC) MEMBRANES Ph Range 4 11 Iron Level (Max.) 1.00 ppm Total Dissolved Solids (max( 2000 ppm Chlorine Level (Max) 2.0 ppm Water Temperature (max) 40 degrees Celsius ** Water Pressure (Max) 100 psi (700 kpa) ** Water Pressure (Min) 30 psi (270 kpa) 40 cms H x 35cms W x 17cms D 8 Litre Tank 39cmsH x 23cms. Diam 11 litre 40 cms.h x 26cms Diameter The R.O. Purifiers will usually be mounted under the sink in homes, offices, shops, motels, and restaurants. Etc. It can also be mounted in any other convenient location. While its usual function is the supply of premium quality drinking water, the high purity water produced by this unit will also be of great value for use in car batteries, radiators, steam irons, air coolers, ice making, printing, electronics, laboratory and pharmaceutical processes. This purifier is assembled with cartridges, membrane and storage tank, Installation parts including Brass Compression Tee Piece, stop valve 500kpa Pressure limiting valve, connectors, are also included. FAUCET ALL TUBING IS COLOUR CODED FOR EASE OF INSTALLATION 1. RED Connects the feed water valve to the RO pre filter. 2. WHITE Connects pure water from the membrane to the storage tank. 3. BLACK Connects waste water from the membrane to the drain connector. 4. BLUE - Connects the post filter to the faucet. Stop Valve

Your Purestream Reverse Osmosis comes with an exclusive SERVICE MODE ACILITY to allow you to backwash your membrane 2 3 times a year to maintain high contaminant removal and eliminate expensive servicing. NOTE: THE BLUE LEVER SHOULD BE AT RIGHT ANGLES TO THE BLACKLINE FOR THE PRODUCTION OF PURE WATER! BACK WASH MODE VALVE INLINE WITH TUBING MEMBRANE PRESSURE GAUGE - Mounted on the membrane housing this allows you to monitor the pressure of incoming water through the membrane. This should be between 30 80psi. Take note of the pressure when installed and allowing for mild fluctuations, if this should drastically reduce i.e. 100 psi down to 40psi, this may indicate that incoming filters could be blocked and need replacing,. NOTE: Gauge will not register when Service Mode is on or when tank is full and production of pure water is not required. USE A LICENSED PLUMBER/TECHNICIAN Damage caused during installation may void your warranty. All care must be taken during installation, which may take several hours. Purifier must be connected to a pressurized and chlorinated cold water supply. An isolating valve or tap should be installed so that you can turn purifier on and off for maintenance purposes Your Purestream Reverse Osmosis Water Filter represents the very best in design with all housings manufactured to Australian Standards STAGE 1 SEDIMENT PRE-FILTRATION 1 micron pre filter to remove sediment particles, grit dust, mud, algae and protects the life of the membrane. STAGE 2 CHLORINE PRE FILTRATION - a special high-grade carbon cartridge pre filter is added to protect the TRC Filmtec membrane from chlorine degradation. STAGE 3 STAGE 4 ULTRAFINE FILMTEC TFC MEMBRANE Screens out the most minute micro-particles. Pore size less than.0005 micron effectively repels heavy metals complexes, all minerals including fluoride, aluminum, lead, mercury etc. micro-organisms and colloidal matter. CARBON POLISHING POST FILTER Provides final polish resulting in superb tasting water. CARTRIDGE REPLACEMENT Sediment Pre filter 12 months Carbon Pre filter 12 months TRC RO Membrane 3 5 years Carbon Post filter 12 months FITTINGS & TUBINGS Hose Quick Fit Connect fittings are used throughout the system. To ensure an optimal seal, tubing should be cut with the end square to provide efficient seal. Each fitting includes a red safety clip to lock connect fitting in place. TO INSTALL, push fitting into Quit Fit Connector unit it bottoms (approx 5mmm) Pull tube back 2mm and the collet will slide out with the tube, then push firmly a second time until tube stops. TO DISCONNECT push collect back against connector, then slide tube out of fitting.

INSTALLATION INSTRUCTIONS This system must be mounted in a vertical position and must be positioned to allow access for service and filter cartridge changing. At the same time the assembly should be relatively near the faucet to maximize flow rate. The storage tank can be placed on its side without affecting the performance of the system. If there is insufficient room under the sink, the tank may be located in an adjacent cupboard. 1. Test water pressure near point of installation noting minimum and maximum requirements. If water pressure is less than 30 psi the unit will not perform satisfactorily. Below 25 psi, you will NOT get any pure water and a booster pump may be required.. 2. Installation fittings included for fitting to a l/2 OD copper line using a compression tee piece. Assembly comes complete with ball valve and 500kpa chrome pressure limiting valve, tubing and separate water faucet 3. Cut 30mm out of pipe and fit tee piece making sure compression olives are pushed over each pipe and firmly tighten compression nuts. 4. Connect red tubing to exit of installation assembly (Pressure Limiting Valve). White tubing should be connected to ball valve on top of tank. INSTALLATION OF FAUCET. The faucet may be installed on any flat surface at up to 50mm in diameter. 1. Using a small drill bit, drill a pilot hold. 2. Then drill a 12mm hole through the base metal. Operate the drill slowly and carefully, especially when the drill is about to penetrate the metal. If necessary use a drop or two of oil in the hole 3. Mount the sink top faucet in the hole and using an adjustable wrench (or hand) to hold the faucet, tighten the 9/16 nut. Make sure the faucet body, chrome plate and black rubber washer are in place above the sink. 4. Install the black locating washer, lock washer and nut while aligning faucet in the desired direction. Included is a grey faucet connector. This screws onto to the base of the thread and tubing is pushed into the quick fit fitting. INSTALLING THE DRAIN OUTLET CLAMP ASSEMBLY Select a location for the drain clamp ABOVE the `S` Trap. Position the drain outlet clamp on the drain pipe. Allow adequate space for drilling. Tighten clamp with `Tightening Screw` Unscrew Quick fit Connector Using the opening in the drain outlet clamp, drill a ¼ hole in the drain pipe. Clean debris from the clamp. Re atttach Quick Fit connector. NOTE: Locate the drain connection away from the garbage disposal to prevent potential contamination and system fouling.

STORAGE TANK Place storage tank in a convenient position. Tank can be placed on its stand, either upright or on its side. A Blue/white valve is located on the top of the unit. One tube is connected to the tank and water flows either way depending on pressure. PRESSURE IN TANK SHOULD BE 8-9 PSI. There is a small valve on base of unit similar to bike tyre valve. This can be measured and increased by use of standard pump. START UP PROCEDURE 1. Turn on water supply and check for leaks. 2. Close Ball Valve on tank. (lever should be at right angles to line). This will allow pure water to come straight to faucet. Open faucet by rotating knob.p. 3 Within a few minutes (up to 15), the water will start to run very slowly from the faucet. Let water run directly from faucet at for least 30 minutes to flush carbon filters and membrane on first time use. 4 Open ball valve on tank (lever should be in line) 5 Close sink faucet lever and allow unit to run 1-2 hours to fill tank. 6 Empty tank and completely and allow to refill. 7. You may now drink the water from your purifier, but please restrict your draw off rate to 2 3 litres per minute. MEMBRANE FLUSHING SERVICE MODE Like all filters, your reverse osmosis membrane gets clogged with minerals, etc and can't do its job. Regular flushing therefore is necessary to maintain the 98% removal of contaminants. To eliminate costly service calls and make it easy for you, we have incorporated an exclusive DIY simple MEMBRANE FLUSHING SERVICE MODE THE BALL VALVE HANDLE SHOULD AT RIGHT ANGLES TO THE BLACK LINE FOR PRODUCTION OF PURE WATER. SERVICING OF UNIT. SERVICE BALL VALVE Your unit incorporates a specially designed ball valve designed to easily flush your membrane. STEP 1 Turn the blue handle stop valve on the top of the tank to right angles to the blue line and open the faucet on the top of the sink. This activates the auto shut off valve to produce water. STEP 2 Turn the blue stop valve installed in the black waste line on the unit to a horizontal position. As the flow restrictor is installed after the first tee piece, this eliminates the back pressure on the membrane and directs full water flow down the membrane flushing any build up of contaminants. RUN FOR 1-2 MINUTES REPLACE BALL VALVE ON WASTE LINE TO VERTICAL POSITION, CLOSE FAUCET AND REPLACE BALL VALVE ON TOP OF TANK TO INLINE WITH BLUE TUBE OR HORIZONTAL. This should be done on a regular basis (2 3 times a year) to maintain maximum performance of membrane in removing contaminants. Run in service position for 2 minutes

MAINTENANCE - REPLACE CARTRIDGES. EVERY 12 MONTHS Aeon offers a cartridge reminder service to do the remembering for you. Every 12 months we will send you a courtesy email with details of your model, cartridge code numbers and a link to the appropriate order page, to make it as easy as possible. The unit comes complete with housing spanner which makes undoing the units easy. To remove, turn left to right. 1. TURN OFF WATER AT STOP VALVE 2. TURN STOP VALVE ON TOP OF TANK TO OFF (RIGHT ANGLES TO LINE) 3. LIFT FAUCET ON BENCHTOP TO REMOVE ALL WATER IN PIPES TO HELP DE-PRESSURISE SYSTEM. 4. Remove old filter cartridges and discard. 5. Thoroughly clean and wash out both pre-filter housing sumps. This can be done with normal household detergent, or sterilize with Domestos. Rinse thoroughly. 6. It is a good idea to check pressure on storage tank as this can decrease over 12 months. You will need to empty the tank to check pressure. Turn off water at stop valve and open faucet, let it run until no water coming out. A valve is located on the base of the tank. This can be checked and increased by use of a bike pump or take to your nearest service station and check with tyre gauge. TANK PRESSURE SHOULD BE 8 9 PSI Purestream Water Filters Manufactured for Aeon Consumerable Products, P O Box 130 Southport B.C. 4215 Phone/Fax 07 55 914 394 Email: kae@purestreamwaterfilters.com.au Website www.purestream.waterfilters.com.au 1300 888 429

CAUTION FOR YOUR SAFETY Membrane & storage tank maintenance Change filters regularly every 12 months and the membrane every 3 5 years. Automatic icemakers require water in the line to work properly. If you are draining the storage tank or have no water during initial start up, turn off the icemaker until the sink top faucet has a steady flow. FILTER AND MEMBRANE CHANGING PROCEDURES Sediment and Carbon Prefilters Turn valve on top of storage tank to off. Turn stop valve to off position on easy tap. Turn off storage tank ball valve. Open R.O. faucet to help de-pressurize system. Unscrew filter housings by turning clockwise. Remove old filters and discard. Rinse. Insert new filters into appropriate housings. Replace O rings as necessary. Be sure O ring is clean, lubricated and seated properly when tightening. Never use Vaseline or any other petroleum based sealant. It may break down the O ring or the seat of the filter housing and cause a failure (leak). Post Carbon Filter Remove red safety clips from either end of post filter. Push collett back on fitting to release tubing. Discard old filter. Your new post filter comes complete with fittings Make sure arrow on new filter is Pgoing with flow of water toward the faucet. Push tubing into quick fit fittings as per instructions R.O Membrane - a small cartridge spanner is available to assist with this procedure. Turn water off at the tank and at the inlet tap valve and open faucet. Disconnect white tube going into end of membrane housing on the end that has only one tube going into it. Unscrew end cap off membrane housing. Water will pour out. Pull out old membrane and clean membrane housing if necessary with warm soapy water. Insert new membrane in the direction of arrow on the membrane. The end with the two small O rings goes in first. The end with the large rubber ring goes in last, next to the removable end cap. Push firmly! Screw end cap back on and reconnect white tube to membrane housing. Open the tank valve and the inlet tap valve. Drain the tank. Allow 2 full tanks to fill and then drain. This will flush the preservative from the membrane prior to drinking. RECOMMENDED SANITISING PROCEDURE -STORAGE TANK It is recommended to sanitize the RO storage tank every 2 years, or at the very least when you change your membrane, every 4 years. OBJECTIVE IS TO REMOVE ALL FILTERS AND MEMBRANE FROM HOUSING AND add a small amount of bleach or Milton 10mls. Into the empty housings, close up housings and turn water on at source allowing sanitizing solution to flow THROUGH THE SYSTEM AND INTO THE TANK, WHERE IT WILL SIT EITHER OVERNIGHT OR A MINIMUM OF 2 HOURS. 1) Turn SHUT OFF VALVE OFF, next to tee piece. Drain all water out of R.O. tank. Remove old prefilters. Remove membrane even if not replacing. Reassemble membrane housing without membrane inside. We recommend you use diluted bleach to disinfect your system. Add 10 ml. small amount into each of the empty pre filter housings. Reassemble pre-filter housings without filters. 2) Turn water supply on at STOP VALVE to about 30% of maximum flow rate and let storage tank slowly fill with tap water (approx 10 minutes). TANK BALL VALVE SHOULD BE INLINE 3) TURN water supply OFF at STOP VALVE. Let entire system sit for about 2 hours to thoroughly sanitize. 4. Open faucet and let storage tank drain until empty. Shut off faucet when empty. Turn WATER SUPPLY ON STOP VALVE and allow tank to fill with water. Again, turn off the STOP VALVE and drain the tank. With water supply OFF, Install the new filters and membrane. This is when you will change the post filter also. Then follow normal system start up procedures, allowing for 2 full tanks of RO water to be flushed.

SET UP ON INSTALLATION GETTING STARTED. 1.Once your unit has been installed, it is necessary to flush preservatives from both membrane and storage tank bladder. To ensure minimium waste of water 1. With tank STOP VALVE turned off - at right angles to the line going into the tank, open faucet on top of sink. Your water should trickle out of faucet ensuring the unit is working correctly. 2. Now turn blue SERVICE MODE stop valve positioned between two cartridges on top of Bracket to horizontal FOR 2 3 MINUTES. This will flush the Membrane QUICKLY MINIMISING WATER LOSS. IMPORTANT THE STOP VALVE MUST BE RETURNED TO RIGHT ANGLES TO THE LINE (AS SHOWN) TO PRODUCE PURE WATER. Show inline with line. 3. TURN OFF FAUCET, OPEN STOP VALVE ON TOP OF TANK (SHOULD BE INLINE WITH TUBING) TO ALLOW WATER TO FILL TANK. Allow 1 2 hours for tank to fill. To flush preservatives from bladder, empty water from tank by opening faucet on top of sink. 4. REFILL TANK AND YOU ARE READY TO GO.