B-AIR BLOWER CUB POWER MODEL # CP-1



Similar documents
OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Wine Cooler with Thermo-Electric Cooling & Heating Technology

User Manual HomeGrid 3000 Solar Generator

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

8" BENCH GRINDER OWNER'S MANUAL

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

3 WATT LED SPOTLIGHT Model No. SLM

2-SLICE COOL TOUCH TOASTER

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Get Me Cool Now Portable Air Conditioner User s Manual

CARING FOR YOUR WATER HEATER

Dehumidifier Users manual. For Models: DH45S DH65S

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

SMS SERIES MIXER SYSTEM INSTALLATION AND MAINTENANCE MANUAL

How To Size A Stenner Pump

DBF 4XL Dryer Booster Fans

IR Repeater. Operation Manual P8620

accidents which arise due to nonobservance and the safety information herein.

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

GAS SAFETY PRECAUTIONS

WARMER or COOKER/WARMER

ClearView 100. Instruction Manual

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

Multi-Pitch Pitching Machine USER MANUAL

100 Series Maxi Internal Filters. Instruction Manual

Operating Manual Color Changing Fountains

3000W Power Inverter

MINI-BRUTE II HOT WATER POWER WASHER MODEL# MBII

Model: Model: Description: Voltage: Amps: Ice Type: Unit Weight:

Operating Guide Manuel de l utilisateur

CHARGING SYSTEMS INTERNATIONAL

Visit our website at: our technical support at:

User s Manual Before using the inverter, you need to read and save the safety instructions.

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

VACUUM CLEANER INSTRUCTION MANUAL

2 electrical. electrical PulteGroup, Inc. All Rights Reserved.

October Safety Subject

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

4 in 1 Air Compressor

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

12-Volt 10-Amp Regulated Power Supply

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

- 2 - IMPORTANT SAFETY REMINDERS

WHYNTER 21 Bottle Dual Temperature Zone Freestanding Wine Cooler

SKILL ATTACK PITCHING MACHINE PATENTS APPLIED FOR INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE

staple gun with 5/16 Long staples

Instructions & Safety Information Models A220-20D and A220-20L Version 2

1 HP MINI DUST COLLECTOR

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Portable Air Conditioner

Single Phase Soft Starter

Please read operating instructions carefully before use and keep for further reference.

Mini Power Bank and Charger

Tablet Management Rack 16

Ride-on Car OWNER S MANUAL KT1151TG. Keep instructions for future reference

Model 349KLX Remote Display Digital Scale User Instructions

Ceiling Mount Air Handler Manual

1100 LB. ELECTRIC HOIST

2 YEAR WARRANTY S7200PAU USE & CARE MANUAL ADVANCED CERAMIC TECHNOLOGY. To register your product go to

Automatik-Lader AL 600 Automatic Charger AL 600 fcr V / for V. Best.-Nr. : / Order No

The Storm 20-Gallon Wet/Dry Vac

Master Prep Professional

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

SUBMERSIBLE PUMP 250 WATTS, WITH FLOAT Model 45014

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

American DJ. Roto-Balls VS MKII. User Instructions. American DJ

Hand Held Metal Detector

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2


LF-IRX. Limited Warranty LF-IRX. Remote Control Extender OWNER S MANUAL

Table of Contents TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY.

Tone Hammer 500. Owners Manual. Manual Version 1.0

DRY-BATH INCUBATOR. MODELS I-G35, I-G55, I-120 and I-240. Owner/Operator Manual

400 Amp Rechargeable Jump Start System RAC-HP082

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

Quartzone Infrared Quartz Tube & Metal Sheathed Electric Heaters

ELECTRIC WINE BOTTLE OPENER OWNER S MANUAL BO60. Visit our web site at

Mini-led spotlight with magnetic base

User and Installation Guide

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

120Volt 60-70A ARC WELDER Rev

SUBMERSIBLE SEWAGE PUMP 66119

3.6 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

Installation and Operating Instructions (for chargers shown below)

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

INFRARED QUARTZ WALL HEATER

INSTRUCTION MANUAL. Manufactured for: Phoenix Manufacturing Inc. 90% Less energy consumption

4-in-1 SWIVEL TABLE. 54in (1.37m) CONTACT INFO Hours. Technical Support Monday to Friday (9:00am to 5pm EST) WARNING:

Transcription:

OWNER S MANUAL B-AIR BLOWER CUB POWER MODEL # CP-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING READ AND SAVE THESE INSTRUCTIONS

INTRODUCTION TO B-AIR CP-1 YOUR NEW B-AIR CUB # CP-1 BLOWER HAS A 1/4 HP HIGH EFFICENCY MOTOR, WHICH HAS STATE OF THE ART CONSTRUCTION AND SCREENS ON OPEN VENTS FOR SAFETY AND LONG LIFE. THE HANDLES ARE DESIGNED FOR EASY CARRYING AND THE UNITS CAN OPERATE IN THREE DIFFERENT POSITIONS. OPERATION/USE THE CUB POWER BLOWER IS INTENDED TO INFLATE SMALL INFLATABLE STRUCTURES. IT IS ALSO SUITABLE FOR A VARIETY OF OTHER APPLICATIONS, INCLUDING USING THEM INTERNALLY.. A) CAREFULLY PLACE THE B-AIR CUB UNIT ON STABLE FLAT DRY SURFACE-KEEPING CHILDREN AWAY. B) ATTACH AN INFLATABLE TUBE AROUND THE EXHAUST OPENING USING STRAPS OR ANY OTHER FORM OF TIGHTENER. C) PLUG CORD INTO A GROUNDED GFCI OUTLET ONLY. D) TURN ON SWITCH AND MAKE SURE IT IS OPERATING CORRECTLY. E) ALL BLOWERS IN OPERATION MUST BE SUPERVISED AT ALL TIMES. STORAGE STORE UNIT INDOORS IN A CLEAN DRY ENVIRONMENT TO ENSURE LONG LIFE

SAFETY 1) BLOWER MUST HAVE BACK PRESSURE, MEANING IT MUST BE ATTACHED TO AN INFLATABLE OR DUCT TO AVOID ANY DAMAGE TO MOTOR. 2) KEEP CHILDREN AWAY FROM UNIT AT ALL TIMES WHILE IN OPERATION AND/OR PLUGGED IN. 3) DO NOT PUT FINGERS OR OTHER OBJECTS IN UNIT WHILE IN OPERATION AND/OR PLUGGED IN. 4) DO NOT OPERATE IN POOLED WATER TO AVOID ELECTRIC SHOCK. 5) MOTOR MUST BE KEPT DRY AT ALL TIMES. IF UNIT BECOMES WET, THOROUGHLY DRY BEFORE NEXT OPERATION. 6) INDOOR USE: USE ONLY WITH A GROUNDED PLUG AND/OR EXTENSION CORD TO AVOID RISK OF ELECTRICAL SHOCK OR FIRE. REMEMBER NEVER TO USE A CORD WITH ANY KIND OF DAMAGE OR WEAR. 7) MAKE SURE THE POWER SOURCE IS SUFFICIENT TO MEET THE REQUIREMENTS OF THE BLOWER. 8) KEEP AIR INTAKES CLEAR AT ALL TIMES TO AVOID CLOGGING OR BLOCKING IN ORDER TO PREVENT OVERHEATING THE UNIT. BLOCKING THE AIR INTAKES COULD RESULT IN A FIRE OR ELECTRICAL HAZARDS. 9) DO NOT REMOVE ANY SCREENS OR SAFETY GUARDS FROM THIS UNIT TO PREVENT INJURY TO PERSONS, AND TO AVOID OBJECTS FROM COMING IN CONTACT WITH THE BLOWER WHEEL. UNIT DAMAGE IN THIS MANNER WILL VOID YOUR WARRANTY. 10) DO NOT OPERATE UNIT CLOSE TO ANY DANGEROUS AREAS, SUCH AS EXPLOSIVE GASES, FLAMMABLES, HEATERS AND VENTILATED ENVIORMENTS, WHICH MAY RESULT IN EXPLOSIONS OR ELECTRICAL HAZZARDS. 11) DO NOT USE ANY FORM OF SPEED CONTROL DEVICE AS DOING SO MAY RISK INJURY OR FIRE. 12) ALWAYS PLACE BLOWER ON A SMOOTH AND LEVELED SURFACE FOR SAFE OPERATION. 13) DO NOT OPERATE IN STACKED POSITION. 14) DO NOT USE UNIT IF DAMAGED. 15) BEFORE CLEANING OR SERVICING UNPLUG UNIT. 16) ALL BLOWERS IN OPERATION MUST BE SUPERVISED AT ALL TIMES.

WARRANTY 1 YEAR: From Original Purchase date will cover all parts (except Cords), labor and one-way shipping costs to your location in the 48 Contiguous states, using UPS Ground Service. Customer will pay shipping to our warehouse. Canada and Non- Contiguous States must pay for freight both ways. 5-YEAR: B-Air will cover Housing from date of Original purchase. SERVICE IN ORDER TO RECEIVE SERVICE OR REPLACEMENT PARTS UNDER WARRANTY, YOU MUST: A) CALL FOR A RMA# (Return Merchandise Authorization Number) B) HAVE PROOF OF PURCHASE C) SHIP TO: B-AIR BLOWERS IF IMMEDIATE SERVICE IS REQUIRED, B-AIR WILL SHIP A REFURBISHED BLOWER IMMEDIATELY TO REPLACE THE ONE REQUIRING SERVICE IF A CREDIT CARD IS PROVIDED AND CHARGED. ONCE WE RECEIVE YOUR BLOWER, WE WILL CREDIT YOUR CREDIT CARD ACCOUNT. WE WILL GLADLY REPAIR YOUR BLOWER AND SHIP WITHIN 24 HOURS UPON INSPECTION, WE WILL CALL WITH THE STATUS OF YOUR ORDER AND WILL ISSUE REPAIR OR REPLACEMENT PARTS DEPENDING ON WARRANTY CRITERIA. CORDS 1) DO NOT USE EXTENSION CORDS FOR OUTSIDE USE. 2) USE 3 PRONG ADAPTORS THAT ARE UL AND CE APPROVED AND NOT LESS THAN 18-3 WITH GROUND FAULT CIRCUIT INTERRUPTER (GFCI). 3) DO NOT USE CORDS THAT SHOW ANY KIND OR WEAR OR DAMAGE. 4) CORDS ARE NOT COVERED BY ANY WARRANTY.

B-AIR BLOWERS LIMITED WARRANTY COVERS 1) B-AIR BLOWERS ARE COVERED AGAINST DEFECTS IN MATERIAL AND CRAFTSMANSHIP USED UNDER NORMAL INTENDED USE TO ORIGINAL PURCHASER FOR A TERM OF (1) ONE-YEAR FROM THE ORIGINAL DATE OF PURCHASE. 2) B-AIR BLOWERS HOUSING IS COVERED FOR A TERM OF (5) FIVE FULL YEARS FROM THE DATE OF THE ORIGINAL PURCHASE. DOES NOT COVER 1) ANY SIGNS OF MISUSE INCLUDING; BUT NOT LIMITED TO ROUGH HANDLING, ABUSE, TAMPERING, IMPROPER VOLTAGE USE, UNAUTHORIZED MAINTENANCE AND REPAIRS. WARNING ALL BLOWERS IN OPERATION MUST BE SUPERVISED AND ATTENDED AT ALL TIMES. THE USE OF A 3-PRONG TO 2-PRONG ADAPTER IS PROHIBITED. ONLY USE A 2-PRONG TO 2-PRONG ADAPTER. CONTACT INTERTEX, INC / B-AIR BLOWERS 1851 TYBURN STREET GLENDALE, CA 91204 1-877-800-2247(BAIR) FAX:(818) 242-2430 EMAIL:INFO@INTERTEXINC.COM WEB SITE: www.b-air.com

SPECIFICATIONS MODEL: CP-1 VOLTAGE 115 V 230 V MAX AIR VOLUME 375 CFM 345 CFM AMPS 2.3 A 1.3 A MAX STATIC PRESSURE 2.8 INCH 2.6 INCH WEIGHT NET/ GR 11/12 LBS 11/12 LBS UNIT SIZE (LxWxH) 10.5 x 10 x 8.5 INCH 10.5 x 10 x 8.5 INCH WHEEL SPEED (RPM) 3400 2850 MOTOR 1/4 HP 1/4 HP ATTACHED CORD (18G) 6 FT 6 FT TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Motor Not Running a) Switch is OFF a) Turn Switch ON b) Bad Outlet b) Check Outlet/ Change to Another Outlet c) Faulty Switch/Cord c) Call Factory for new Switch/Replace Cord Scraping Noise From Blower a) Wheel Out Of Line a) Call Factory for Replacement Advise Weak Air Flow a) Obstructed Vents/Inlets a) Clean Out Vents/Inlets