MODEL G300 BRAKE BLEEDER



Similar documents
Hydraulic Transmission Jacks Operating Instructions & Parts Manual

PALLET JACK TON

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

8 ton air/hydraulic long ram jack

HYDRAULIC TABLE CART

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Table of Contents WARNING SYMBOLS AND DEFINITIONS

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

55-Gallon Dispenser Package

Installation Instructions and Service Manual

LIFT N RACK PRO OPERATING & INSTALLATION GUIDE 5500 Lb. LIFT CAPACITY

Extrusion Flo-Valve INSTRUCTIONS-PARTS LIST psi (210 bar) Maximum Working Pressure. Model , Series K. Rev.

Installation Instructions and Service Manual

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

MP-4V Heavy Duty Riveter / 39048

OAK WORKBENCH WITH 2 DRAWERS

Auxiliary Rams USERS MANUAL

Fluid Regulator. Instructions Parts List L LOW PRESSURE

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Instructions and precautions. Fork Height. Visit our website at:

HYDRAULIC LIFT TABLE CART 2200-LB.

1 Ton Telescoping Gantry Crane

Flat Bottom Long Ram Hydraulic Jack

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Operating Instructions Manual. Hydraulic Transmission Jack, Telescopic

Rexroth Hydraulic Pump A10VO Series User Manual

CONGRATULATIONS! TABLE OF CONTENTS. 1 Safety Warnings 2 About Your Wheels 3 Setting Up Your Wheels 7 Care and Cleaning 8 Warranty

HYDRAULIC TABLE CART 500-LB.

Instructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure.

Installation Instructions GOOSENECK MOUNTING KIT Chevrolet/GMC 1500/2500/3500 All except 4-door Crew-Cab

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

TABLE OF CONTENTS CABINET SAFETY

1000-LB. TRAILER JACK OWNER S MANUAL

CHROME FRONT BRAKE MASTER CYLINDER KIT

MODEL # Introduction

8-TON BOTTLE JACK OWNER S MANUAL

PAINT SPRAY GUN WASHER

ATS Overhead Table Shelf System INSTRUCTION MANUAL

HPU14M-DS 2013 Daniels Manufacturing Corp., All Rights Reserved Page 1 of 17 REV. C 7/2013

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

Meritor WABCO Hydraulic Power Brake (HPB) System Bleeding Procedures

ROUGHNECK II Pumpless Drain

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

758 Heavy-duty Ratchet Guy Wire Cutter

OWNER S MANUAL Table Tennis Table Patent Pending

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

Owner s Manual & Safety Instructions

NITROUS TRANSFER PUMP INSTRUCTIONS

Railgates By THIEMAN IMPORTANT! KEEP IN VEHICLE! PLEASE READ AND UNDERSTAND THE CONTENTS OF THIS MANUAL BEFORE OPERATING THE EQUIPMENT.

SKILL ATTACK PITCHING MACHINE PATENTS APPLIED FOR INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE

HAND PUMP OPERATION, SERVICE AND PARTS INSTRUCTION MANUAL

SINGLE STAGE INLINE FIRE PUMP

Air/Hydraulic Bottle Jack

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

BUGGY SETUP GUIDE. Volume GOKARTSUSA GY6 150, CN250. Buggy Setup Guide

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

L /96. Haldex INSTALLATION INSTRUCTIONS HALDEX PURE AIR PLUS EXTENDED PURGE KIT (DQ6027) HEAVY DUTY CANISTER KIT (DQ6028)

Style 9168 Field Service Kit Black Max Piston intake valve

Air vacuum pump with r134a & r12/22

GEAR BOXES MAXIMUM LOAD LIMITS: SpaceCadet. SpaceBooster. RocketBox. box weight. box contents

Series Hose Reels

READ CAREFULLY - FAILURE TO FOLLOW INSTRUCTIONS AND SAFETY RULES MAY RESULT IN SERIOUS INJURY

OWNER'S MANUAL P O L Y C A R T, 1 7 C U B I C F O O T M O D E L : P C T B H. Assembly Installation Operation Repair Parts

All in One Activity Walker Instruction Manual

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

Cooling system components, removing and installing

Installation manual front leveling kit Dodge Durango Jeep Grand Cherokee. Part # Part # 42006

PNEUMATIC PLANISHING HAMMER

SunMaxx Solar Filling Station Operating Instructions

SHOP PRESS ASSEMBLY INSTRUCTIONS

13. REAR WHEEL/BRAKE/SUSPENSION

Owner s Manual & Safety Instructions

Auto-belay Cable Replacement Process

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Class 5 to 7 Truck and Bus Hydraulic Brake System

HC-3000 SERIES RAKE Parts Breakdown DURABILT INDUSTRIES, LLC AIRPORT ROAD POCAHONTAS ARKANSAS 72455

92-00 Civic/ Integra/ Del Sol/ CRX Rear Kit Part No

Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09 DAYTONA

Hydraulic Punch Driver Kit

Thank You For Choosing. INSTALLATION INSTRUCTIONS Portal Gear Hubs Polaris RZR XP 900 Crew. (Right) (Left)

The Storm 20-Gallon Wet/Dry Vac

OP300S / OP350 2:1 RATIO TRANSFER PUMP

tire inflator with pressure gauge

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

GM DURAMAX LMM Fuel Pickup Kit Installation Guide

PETOL POP-IT Flange Spreader & Prying Tool. Model PHD0535. Warning

Snow Blower Cab. Owners Manual. Heavy Duty Vinyl Cover Heavy Gauge Tubular Steel Frame. Model No Safety Assembly Operation Maintenance Parts

MEDIUM FLAT PANEL DISPLAY STATIC MOUNT MSR Series

INGROUND, ROPED, AND HOLELESS JACK SEAL REPLACEMENT

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

1 / 4 IN. FFL x 4 FT. 9 IN. 1 / 2 IN. ACME x 4 FT. 9 IN. Gauge Accuracy +/-2% Set includes Quick Disconnect Valves

Transcription:

MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G

1

THIS PAGE INTENTIONALLY LEFT BLANK 2

TABLE OF CONTENTS SAFETY INSTRUCTIONS 2 DEFINITIONS 2 SPECIFICATIONS 3 INTENDED USE 3 INSTALLATION INSTRUCTIONS 3 COMPONENT IDENTIFICATION 4 OPERATING INSTRUCTIONS 5 MAINTENANCE 6 BRAKE BLEEDER REPAIR PARTS 7 ADAPTER REPAIR PARTS 8 ADAPTER INSTRUCTIONS 9 WARRANTY 11 SAFETY INSTRUCTIONS NEVER allow unauthorized personnel to operate this product. NEVER use this product for anything other than its intended use. THOROUGHLY train new employees in the proper use and care of this product. PROHIBIT unauthorized personnel from being in shop area while this product is in use. DEFINITIONS CAUTION: Indicates a potentially hazardous situation, which if not avoided, may result in damage to property or minor personal injury. HAZARD: A source of potential injury to a person. MAINTENANCE: Those actions that preserve the correct and proper conditions under which the machine shall be used. This may include adjustment, replacement of wear items, lubrication and cleaning, but not modifications or repair of damage. MAY: This word is understood to be permissive. MUST: This word is understood to be mandatory. OPERATION: The correct and proper use of the machine as described in this manual. SAFETY ALERT SYMBOL: A symbol that indicates a potential personal safety hazard. It is composed of an equilateral triangle surrounding an exclamation point. SHALL: This word is understood to be mandatory. SHOULD: This word is understood to be advisory. WARNING: Indicates a potentially hazardous situation, which if not avoided, may result in death or serious personal injury. 2

CAUTION Before using this product, read and fully understand the operating instructions and all decals on the product. This is necessary to prevent injury to the operator and damage to the product. Do not attempt to use this product for anything other than the intended use. Refer to vehicle service manual for proper bleeding procedure. Do not use Aviation or Hydraulic Fluid with this product. Product damage may result. Avoid allowing Brake Fluid to contact vehicle finished surfaces. Damage to the surface finish may result. Always wear appropriate eye protection. SPECIFICATIONS Capacity 4 gallons Max Air Pressure 55 psi (3.8 bar) Dimensional data (h x w x d) base only 16.75 x 13.5 x 13.5 base and handle 31 x 13.5 x 13.5 Weight: 26 lbs (11.8 kgs) INTENDED USE The G300 Brake Bleeder is a pneumatic diaphragm device designed to exchange old brake fluid for new while purging air bubbles from automotive hydraulic brake systems. INSTALLATION INSTRUCTIONS 1. Unpack and remove unit from shipping carton. 2. Inspect unit for any visible damage. 3. To install handle assembly to Brake Bleeder body; loosen set screw on handle receiver, insert handle, and tighten set screw to secure handle. 4. Fill with brake fluid following directions in Filling Fluid Reservoir section of Operating Instructions. CAUTION Excessive air pressure can result in serious damage to this diaphragm type brake bleeder. Always follow the vehicle manufacturer s recommendations and never exceed 55 psi. 3

COMPONENT IDENTIFICATION 1 8 2 9 3 6 10 4 7 5 11 12 ITEM DESCRIPTION 1 Handle 7 Air Purge Valve 2 Bleeder Hose 8 Shut-off Valve 3 Pressure Gauge 9 Filler Plug Washer 4 Filler Hole 10 Filler Plug 5 Reservoir 11 Safety Relief Valve 6 Quick Coupler 12 Pressure Release Valve 4

OPERATING INSTRUCTIONS Filling Fluid Reservoir 1. Remove valve cap from release valve on bottom of bleeder. Use valve cap top to remove valve core from release valve to allow air to escape. (Image 1) 2. Remove hose assembly from top of bleeder by loosening wing nut, turning filler plug washer to align with opening (Image 2), and lifting assembly off. 3. If refilling, internal rubber diaphragm might be inverted inside tank and must be gently pushed back into place using a clean blunt instrument inserted through filler hole (Image 3). Note: Using a sharp object or too much force can damage the rubber diaphragm. Figure 1 Figure 2 Figure 3 4. Insert a plastic funnel tightly into filler hole and fill with brake fluid (Image 4). If reservoir overfills and fluid enters funnel, use suction syringe to remove excess. 5. To install hose assembly into bleeder filler hole; align filler plug washer with opening in upper plate of filler hole, push filler plug washer below upper plate, turn washer 90 o in either direction and lock in place by tightening wing nut. 6. Use valve cap to reinstall valve core in release valve. 7. Check shut off valve on hose to ensure it is closed (turned clockwise until it stops) (Image 5). 8. Connect air hose to release valve on bottom of bleeder and inflate bleeder until pressure gauge reads specified pressure. 9. Insert purge valve into quick coupler on end of hose assembly. 10. Open shut-off valve and bleed air from hose and reservoir by opening purge valve (turn counter-clockwise) over container. Process is complete when fluid produces a smooth steady stream (Image 6). Figure 4 Figure 5 Figure 6 Brake Bleeding Procedure 1. Refer to vehicle service manual to determine appropriate pressure and adjust accordingly by adding or removing pressure through release valve located under reservoir. 2. If a new master cylinder is being installed, bench bleed it before installation. 3. Fill vehicle master cylinder to maximum level or approximately ½ below master cylinder reservoir rim. DO NOT fill to top. The air pocket left in reservoir will act as a trap for any air bubbles present / created during bleeding process. 5

4. Determine appropriate adapter for vehicle being serviced based on Adapter Guide and install on vehicle master cylinder according to Brake Bleeder Adapter Instruction. If present, remove purge valve from quick coupler on end of hose assembly and connect quick coupler to installed adapter. 5. Check all bleeder connections and vehicle s brake lines for leaks. If a leak is detected close shut off valve, wrap a rag around quick coupler to prevent drips and disconnect quick coupler from adapter. Correct problem before proceeding. 6. If vehicle master cylinder and/or booster unit have bleed screws, bleed these prior to bleeding wheels. 7. Use vehicle service manual to determine correct bleed procedure. Note: Always refer to vehicle service manual for proper bleeding procedure. 8. Apply brake pedal, if pedal feels soft, repeat bleeding operation. 9. When bleeding is complete, wrap a rag around quick coupler to prevent drips and disconnect from adapter at master cylinder. 10. Remove adapter from master cylinder. 11. Check brake fluid level in master cylinder and add or remove as needed for correct level. 12. Replace master cylinder cover. MAINTENANCE ALWAYS: Keep Brake Bleeder, adapters, and other accessories clean to prevent contaminants from entering the brake fluid. 6

REPAIR PARTS ITEM PART NO QTY DESCRIPTION ITEM PART NO QTY DESCRIPTION 1 075-134 1 Reservoir Base 15 055-169 1 Seal Nut (Special) 2 041-076 1 Brake Bleeder Diaphragm 16 006-034 1 Rubber Filler Plug 3 075-133 1 Reservoir Top 17 108-156 1 Filler Plug Washer 4 106-022 3 Swivel Caster 18 055-059 1 3/8-24 Wing nut 5 096-393 1 1/8 NPT Male Tee Fitting 19 268-612 1 Filler Plug Core Tube 6 190-270 1 60 PSI Relief Valve 20 190-268 1 Shut Off Valve 7 190-001 1 Air Release Valve 21 646-228 1 Hose 8 096-423 1 Release Valve Extension 22 034-044 1 1/8 Npt Male Quick Coupler 9 070-106 1 Handle 23 940-046 1 Hose Assembly 10 550-020 1 Rubber Grip 24 646-229 1 3/16 I.D. Bleeder Tube 11 028-391 1 1/4-20 X 1/2 Set Screw 25 646-230 1 1/4 Bleeder Tube 12 023-013 1 Pressure Gauge 26 885-098 1 Brake Fluid Syringe 13 028-392 20 #12-24 X 1/2 Machine Screw 27 901-063 1 Purge Valve Assembly 14 055-174 20 #12-24 Square Nut 7

BRAKE BLEEDER ADAPTER REPAIR PARTS 26G 901-052 47G 901-059 29G 901-053 45G9 901-058 6 8 35G 901-054 36G (lg) 901-066 36G (sm) 901-065 41G9 901-056 #20 901-051 42G 901-057 39GC 01-0071 22A 901-062 ITEM PART NO QTY DESCRIPTION ITEM PART NO QTY DESCRIPTION 1 096-418 1 1/4-28 Quick Coupler Nipple 11 096-422 1 1/8 NPT Quick Coupler Nipple 2 921-009 1 Chain & Eyebolt Assembly 12 - - - 3 808-023 1 #39 Grommet (3/4) 13 167-031 1 Gasket 4 808-022 1 #17 Grommet (13/16) 14 167-033 1 Gasket 5 808-019 1 #14 Grommet (11/16) 15 808-018 1 #13 Grommet (7/8) 6 020-039 1 Master Cylinder Cap 16 808-017 1 #12 Grommet (1-1/4) 7 01-0262 1 J Bolt Assembly 17 808-016 1 #11 Grommet (1-3/8) 8 167-027 1 Gasket 18 808-021 1 #16 Grommet (1-9/16) 9 808-020 1 #15 Grommet (1-5/16) 19 020-037 1 Master Cylinder Cap 10 167-024 1 Gasket 20 167-026 1 Gasket 8

BRAKE BLEEDER ADAPTER INSTRUCTIONS CAUTION WHEN USING ADAPTERS, CHECK TO ENSURE NO WIRING, HOSES, OR OTHER COMPONENTS ARE BETWEEN CHAIN AND MASTER CYLINDER BODY. 36G / 39GC NOTE: 39GC can be used singly or paired as needed to fit application. Pairing requires #20 Dual Bleeding Attachment (p/n 901-051). 1. Remove cover from reservoir. 2. Insert grommet through reservoir into port(s) in master cylinder. For 36G, align adapter cap with reservoir opening and snap into place. 3. Tighten wing nut below quick coupler nipple to expand grommet for tight seal. 4. Wrap chain under master cylinder and slip link over J hook when snug. If adapter does not have J hook, slip chain into slot on tab of adapter cover. 5. Tighten wing nut on eye hook and J hook evenly to create firm seal between adapter and reservoir opening. 6. Attach quick coupler from brake bleeder to adapter. 26G / 47G NOTE: These adapters can be used singly or paired as needed to fit application. Pairing requires #20 Dual Bleeding Attachment (p/n 901-051). 1. Remove cover from reservoir. 2. Align adapter with slots on master cylinder reservoir and twist on. 3. Tighten wing nut to expand grommet for tight seal. 4. Attach quick coupler from brake bleeder to adapter. 35G 1. Remove cover from reservoir. 2. Insert grommet into reservoir opening 3. Tighten wing nut below quick coupler nipple to expand grommet for tight seal. 4. Wrap chain under master cylinder and slip link over J hook when snug. If adapter does not have J hook, slip chain into slot on tab opposite eye bolt connection. 5. Tighten wing nut on eye hook and J hook evenly to create firm seal between adapter and reservoir opening. 6. Attach quick coupler from brake bleeder to adapter. 29G / 41G9 / 42G / 45G9 1. Remove cover from reservoir. 2. Align adapter cap with reservoir opening. 3. Wrap chain(s) under master cylinder and slip link over J hook when snug. If adapter does not have J hook, slip chain into slot on tab opposite eye bolt. 4. Tighten wing nut on eye hook and J hook evenly to create firm seal between adapter and reservoir opening. 5. Attach quick coupler from brake bleeder to adapter. 9

NOTES 10

Branick Industries, Inc. COMMERCIAL WARRANTY This product is warranted by BRANICK INDUSTRIES, INC. to the original user-owner against defective materials or workmanship. During the warranty period, if Branick determines the product to be defective, it will be repaired or replaced (at Branick s option) without charge. Warranty Period 1 year from date of delivery. This warranty does not cover defects in the product caused by ordinary wear and tear, abuse, misuse, overloading, accident (including shipping damage), improper maintenance, alteration, or any other cause not the result of defective materials or workmanship. REPLACEMENT IS THE EXCLUSIVE REMEDY FOR DEFECTIVE PRODUCT UNDER THIS WARRANTY. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE OF THIS PRODUCT. BRANICK INDUSTRIES, INC. SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES. BRANICK INDUSTRIES, INC. reserves the right to make changes in the design or construction of our products without obligation to incorporate such changes in products already sold and without notice. Service parts, warranty, and regular repair service are available from: BRANICK INDUSTRIES, INC. Box 1937 Fargo, North Dakota 58107 800-437-4394 Copyright 2016 by Branick Industries, Inc. Printed in U.S.A. 11