Noise Evaluation of Shinkansen High-speed Test Train (FASTECH360S,Z)



Similar documents
Opening of Tohoku Shinkansen Extension to Shin Aomori and Development of New Faster Carriages Overview of Series E5/E6 Shinichiro Tajima

Advanced Train Technology and Train Design Creating New Value

INTRODUCTION TO BEAMS

Guideline. Date:

The risk of derailment and collision, and safety systems to prevent the risk

Maintenance and Management of JR East Civil Engineering Structures

Direct and Reflected: Understanding the Truth with Y-S 3

Technological overview of the next generation Shinkansen high-speed train Series N700

BNAM 2008 BERGEN BYBANE NOISE REDUCTION BY TRACK DESIGN. Reykjavik, august Arild Brekke, Brekke & Strand akustikk as, Norway

Chapter 3 Pre-Installation, Foundations and Piers

Mastering very high speed

Research for High Speed. Pierre-Etienne Gautier INEXIA, Scientific Director St Denis la Plaine, France

How To Counter Noise Noise From A Low Voltage Differential Signaling Circuit

Environmentally Friendly Railway-car Technology

Traffic Monitoring Systems. Technology and sensors

Power Electronics Technologies for Railway Traction Systems

Railway Business Strategy and R&D in Europe

Braking/Traction Control Systems of a Scaled Railway Vehicle for the Active Steering Testbed

Handbook 16. Handbook 16. AC electrified lines. GE/RT8000/HB16 Rule Book

CANON XA 10 IMPORTANT VIDEO & AUDIO SETTINGS

A name a commitment! These are the criteria which have characterized the development of dependable everyday cars up to the present time.

TABLE OF CONTENTS. INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE...

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

APC APPLICATION NOTE #112

A Short Course on Wheel Alignment

LOCKHEED GEORGIA LOWSPEED WIND TUNNEL HONDA CIVIC HATCHBACK AIRTAB(R) MODIFICATION RESULTS

Access onto roof from Center Block

HSR THE TRAIN OF THE FUTURE New technologies and research trends

A Game of Numbers (Understanding Directivity Specifications)

2 Ohm Nominal Coaxial Speaker OWNER S MANUAL

Investigation of sound insulation for a Supply Air Window field measurements and occupant response

The Development of Virtual Testing Model for Korea High Speed Train

Extracts from BUILDING REGULATIONS

MONDOATHENS BASKETBALL SET (Reference PK110)

Applicable standards in CR Rolling stock - Freight wagons TSI (2006/861/EC)

Digges 1 INJURIES TO RESTRAINED OCCUPANTS IN FAR-SIDE CRASHES. Kennerly Digges The Automotive Safety Research Institute Charlottesville, Virginia, USA

TABLE OF CONTENT

Making Your Home Ready For Solar Water Heating

Siemens AG Mobility Division Nonnendammallee Berlin Germany

Technical Service Bulletin

INSTALLATION and OPERATION RANGE BALL CONVEYOR MODEL NO: BC-001AN

State Newton's second law of motion for a particle, defining carefully each term used.

The Reflexion Filter. Manual. Electronics

Replacing the noisy cooling fan in ICOM IC-2KL by Bert Almemo, VE3OBU/SM7BUR

State Newton's second law of motion for a particle, defining carefully each term used.

How to build a Pizza Oven in 4 days

Train scheduling of Shinkansen and relationship to reliable train operation

ARTIFICIAL NEURAL NETWORKS FOR ADAPTIVE MANAGEMENT TRAFFIC LIGHT OBJECTS AT THE INTERSECTION

MONORAIL. Scomi Rail THE REVOLUTION OF URBAN TRANSIT. A smooth ride quality. Higher passenger capacity. Energy efficiency. Lower operating costs.

RCAR Low-speed structural crash test protocol

SBB Infrastructure, Measurement and Diagnostic Technology.

CHAPTER 4 4 NUMERICAL ANALYSIS

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

CRASH ANALYSIS OF AN IMPACT ATTENUATOR FOR RACING CAR IN SANDWICH MATERIAL

Replacement Windows and Doors

review/assessment questions

Feasibility of a Directive On-Board Locomotive Audible Warning Device

Little British Car Co.

GEK-90214B. GE Lift Truck. User s Guide 144D2933G1 144D2912G1 144D2911G5

Solar Heating Basics Page 1. a lot on the shape, colour, and texture of the surrounding

CEPro. Advantage Series. Diagrammatic Guide to In-Ceiling Speaker Placement for Home Theater, Multiroom Audio

INTER-NOISE DECEMBER 2006 HONOLULU, HAWAII, USA

Module 3.7. Thermal bridging

ITARDAInstitute for Traffic Accident

Acoustical Design for Concert Hall in the Science and Art Centre of Xiamen University

HITACHI INVERTER SJ/L100/300 SERIES PID CONTROL USERS GUIDE

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications

Effects of Strong Cross Winds on High-Speed Trains a Risk Assessment Approach

Driving Safety Support Systems Utilizing ITS Radio System

chapter 3 basic driving skills

X-Cruiser Series Installation Guide

NVH TECHNOLOGY IN THE BMW 1 SERIES

Railway-vehicle Technologies for European Railways

Abaqus Technology Brief. Automobile Roof Crush Analysis with Abaqus

Clad Direct Glaze Window Installation Instructions

Application Note Receiving HF Signals with a USRP Device Ettus Research

Development of New Inkjet Head Applying MEMS Technology and Thin Film Actuator

Electrical Wiring Technical Bulletin

Adaptive strategies for office spaces in the UK climate

Water supply in tall buildings: roof tanks vs. pressurised systems

DOC.TC.TC.RP

Power and Cooling for Ultra-High Density Racks and Blade Servers

conventional system operation

Gröna Tåget Technologies

KS-70. Catheterization Table GENERAL

Contents BB93 Acoustic Design for Schools

Analysis of free reed attack transients

Applying RFID in traffic junction monitoring

Lab 4 - Data Acquisition

Noise associated with the ground water systems serving residential geothermal heat pumps

High-speed folding doors. F Series

Power Supply, Cooling and Mechanical Technologies for Green IT

LINE POWERED ADA TELEPHONE USER S MANUAL Use With Part Numbers , , , , , and

SIMPLE SAVER SYSTEM DESIGN MANUAL

Retrofit structural insulated panels (SIPs) increase sound transmission loss of existing single family houses impacted by highway noise

Scope: Communications and Electronic Systems addressed in this section include:

The world s first line monitor

COMPLIMENTARY WOODWORKING PLAN

Transcription:

Noise Evaluation of Shinkansen High-speed Test Train (FASTECH360S,Z) H.Yamada, Y.Wakabayashi, T.Kurita, M.Horiuchi R&D Center of JR East Group, East Japan Railway Company, Saitama, Japan Abstract Noise reduction is one of the major technical challenges for further speed-up of the Shinkansen. FASTECH360S and Z, high-speed test trains developed by East Japan Railway Company for the purpose of verifying technologies for future practical trains, incorporate various countermeasures aiming at noise reduction at higher speed. Through 3 years running tests since 2005, the performance of each countermeasure has been determined. In this paper, outlines of the tests designed to evaluate these countermeasures are explained and evaluations are made by referring to test results obtained by various microphone configurations. As a result of the tests, it has been concluded that the train speed at which the noise level is the same as current commercial trains running at the speed of 275 km/h is about 330 km/h for FASTECH360S+360Z (coupled), and is about 340km/h for FASTECH360S (alone). 1 Introduction Noise reduction is one of the major technical challenges for further speed-up of the Shinkansen. In general, the noise level exponentially increases according to the train speed. However, in Japan, it is needed to prevent the noise level from rising even when the train speed is increased. In order to overcome this technical challenge, East Japan Railway Company has developed high-speed test trains FASTECH360S and Z which incorporate several countermeasures for noise reduction at higher speed, and has performed running tests up to 360 km/h. In this paper, outlines of the tests designed to evaluate these countermeasures are explained and evaluations are made by referring to test results obtained by some types of microphones. Furthermore, overall noise performance of FASTECH360 is also discussed in comparison with that of current commercial trains. 2 Test Trains and Noise Measurements In this section, outlines of test trains and noise measurements used for noise evaluation are described. 2.1 High-speed Shinkansen Test Trains (FASTECH360S and 360Z) East Japan Railway Company developed two types of high-speed test trains; FASTECH360S and 360Z, and has performed high-speed running tests since June 2005. FASTECH360S is a high-speed test train designed for running only on Shinkansen Lines, and has 8 cars numbered as shown in Fig.1 (a). FASTECH360Z is also a high-speed test train designed for through operation between Shinkansen lines and converted conventional lines, and has 6 cars numbered as shown in Fig.1 (b). That is, FASTECH360Z runs both on Shinkansen lines and on conventional lines converted to Shinkansen gauge. Because of the narrower clearances on conventional lines, the cross sectional area of FASTECH360Z is smaller than that of FASTECH360S. Note that these trains can run with only one pantograph by adopting a multi-segment slider, while the currently operated Shinkansen trains use two pantographs to avoid arcs due to contact losses. [1] The pantograph nearer the front of the train is folded and could no longer be seen from the noise measurement point. It is also possible to couple these two test trains. With car No. 8 of FASTECH360S coupled to car No. 11 of FASTECH360Z, running tests were performed with Car No. 16 at the front in the down (north bound) direction.

Travel direction Down (down (North bound)) Up No.8 No.7 No.6 No.5 No.4 No.3 No.2 No.1 (a) FASTECH360S Down Up (b) FASTECH360Z Fig. 1 FASTECH360S, 360Z, and their pantograph positions 2.2 Countermeasures of FASTECH360 for Noise Reduction Both FASTECH360S and 360Z have several countermeasures to reduce wayside noise in the five categories of Shinkansen noise; (1) Pantograph noise, (2) Aerodynamic noise from the train nose, (3) Aerodynamic noise from the upper parts, (4) Noise from the lower parts, (5) Structure-borne noise. [2] Table 1 shows primary countermeasures applied on the test trains. Note that some of the countermeasures are different between 360S and 360Z due to the smaller size of 360Z as mentioned above. One example of this difference is pantograph noise insulation plates of FASTECH360Z. They are built to be vertically movable to allow FASTECH360Z to run on the converted conventional lines which have narrower clearance, while those of FASTECH360S are fixed to the car body. Table 1: Primary countermeasure applied on FASTECH360S and 360Z Noise Classification Countermeasures (1) Pantograph noise (a) Low-noise pantographs (b) Pantograph noise insulation plates (2) Aerodynamic noise (a) Bogie covers from the train nose (b) Smoothed door to the drivers cab (c) Snowplow cover (3) Aerodynamic noise (a) Circumferential bellows from the upper parts (b) Smoothed roof without cables (4) Noise from (a) Bogie covers the lower parts (b) Sound absorbing panels (5) Structure-borne noise (a) Lighter axle load 2.3 Noise Measurements No.16 No.15 No.14 No.13 No.12 No.11 Three types of microphones were used to evaluate noise performance of test trains, and measurements were taken of trains running in the down direction. In this section, outlines of the measurements are explained. 2.3.1 Measurement using a Spiral Microphone Array A spiral microphone array was used to capture noise distribution of moving trains. [2] Fig. 2 shows a schematic diagram of the measurement. This enables us not only to specify locations of noise sources in the car body but to know whether countermeasures are effective or not by comparing results taken in various conditions.

Spiral microphone array Line sensor camera 10m 5m φ 4m track Noise Barrier removed Fig. 2 Schematic diagram of measurement using spiral microphone array 2.3.2 Measurements using a Non-directional Microphone and a Microphone Array Both a non-directional microphone (dynamic characteristic: slow) and microphone array (time constant: 35msec) were placed 25m away from the nearest track where the wayside Shinkansen noise was evaluated. The schematic diagram of measurement using these microphones is shown in Fig. 3. An example of measurement result using the microphone array is shown in Fig. 4. Peak and low levels of sound pressure level can be seen for each car, and these are good indicators of noise performance of trains. Non-directional microphone Microphone array 1.8m R.L 8.9m Slab track 1.2m 25m Fig. 3 Schematic diagram of measurement using non-directional microphone and microphone array Pantograph peak Inter-car gap peak Sound pressure level db(a) FASTECH360Z Fig. 4 An example of measurement result using microphone array (360S and Z coupled) 3 Testing the Effect of Each Countermeasure In order to evaluate the effect of each countermeasure for noise reduction, deterioration tests were performed by replacing countermeasures with conventional structures, and measurement results are compared among cases. In this chapter, details of deterioration tests for some of the main countermeasures and the test results are described. 3.1 Pantograph Noise Insulation Plates FASTECH360S Time Pantograph noise insulation plates were installed to reduce pantograph noise, which is the most dominant among all noise sources. In order to evaluate their effectiveness, movable 1sec Low level 10 db

pantograph noise insulation plates of FASTECH360Z shown in Fig. 5 were used. Noise levels were compared with those plates in the up and in the down position. Noise distributions of both cases are shown in Table 2. As seen in the table, the noise distributions of w/o Plates are remarkably worse. Fig. 6 indicates pantograph peak level with and without pantograph noise insulation plates. In these graphs, it is confirmed that peak level increases by 4.4 db for a down pantograph and 2.6 db for an up pantograph, which agree with the tendency seen in noise distributions. The greater increase in noise from the down pantograph is attributed to the wider hidden area of this pantograph. Since the down pantograph is folded and could no longer be seen from the measurement point, while the head of the up pantograph could be seen from the same point, it is considered that the insulation effect of the plates is greater. In Fig. 7, sound pressure level (SPL) at 25m from the track is shown. As can be seen, the increase reaches about 1.5 db. That means achievable train speed is decreased by about 20 km/h if pantograph noise insulation plates are not used. Fig. 5 Pantograph noise insulation plates on FASTECH360Z (in Up and Down position) Table 2. Noise distribution of pantographs with and without pantograph noise insulation plates w/ Plates w/o Plates Down Pantograph Up Pantograph 20 db Pantograph Peak Level (db(a)) w/ Plate w/o Plate Pantograph Peak Level (db(a)) w/ Plate w/o Plate 260 280 300 320 340 360 380 260 280 300 320 340 360 380 (a) Down pantograph (between No. 14 & 15) (b) Up pantograph (between No. 12 & 13) Fig. 6 Comparison of pantograph peak level with and without pantograph noise insulation plates (microphone array)

Sound Pressure Level (db(a)) w/ Plate w/o Plate 3.2 Smoothed Roof 260 280 300 320 340 360 380 Fig. 7 SPL at 25m with and without pantograph noise insulation plates (non-directional microphone) FASTECH360 has a smoothed roof on which there are no cables for high-voltage like those on the roofs of current commercial trains such as series E2. The value of this countermeasure was investigated by placing dummy cables on the top of the roof as shown in Fig. 8. Cables were placed from car No.13 through No. 15. Straight joints were placed between car No. 15 and No. 16, and a cable head was also placed between car No. 13 and No. 14, which was replaced by a straight joint during the tests to compare noise performance. The comparison of noise distributions with and without cables is in Fig. 9. In (b) of this figure, noticeable noise can be observed on the roof where cables are attached. In particular, the noise level is greater around the straight joint and the cable head than around the cables because of aerodynamic noise caused by the configulation. Fig. 10 shows lowest and peak levels measured by microphone array with and without cables. In these graphs, it is confirmed that the lowest noise level of car No. 15 is increased by 2.7 db when cables are added, while the peak level between car No. 13 and No. 14 is increased by 2.7 db when the cable head is added. When the cable head was replaced by a straight joint, noise level was decreased by 0.7 db compared to the case of cable head. But noise level was still 2 db greater when there were no cables. In Fig. 11, sound pressure level (SPL) at 25m from the track is shown. As can be seen, it increases by 0.4 db. According to further calculation it was revealed that the cable head was one of the greatest contributors to overall noise, and increased the sound pressure level by almost 0.3 db. No.16 No.15 No.14 No.13 No.12 No.11 Fig. 8 An outline of deterioration tests for smoothed roof (cable size is exaggerated in the figure)

20 db (a) Smoothed roof Bottom Level (db(a)) Smoothed w/ Cable (b) Roof with cables Fig. 9 Comparison of noise distributions with or without cables 260 280 300 320 340 360 380 260 280 300 320 340 360 380 (a) Intermediate car (No. 15) (b) Inter-car gap (between No. 13 & 14) Fig. 10 Comparison of bottom and peak level with and without cables (microphone array) Inter-car Gap Peak Level (db(a)) Smoothed Cable Head Straight Joint Sound Pressure Level (db(a)) Smoothed w/ Cables Fig. 11 SPL at 25m with and without plates (non-directional microphone) 3.3 Circumferential Bellows 260 280 300 320 340 360 380 Gaps between cars of FASTECH360 are entirely covered with circumferential bellows. Comparison was made to measure their effect by replacing them with conventional bellows of the type used on series E3, a current commercial train used for through operation. (shown in Fig. 12) Noise distributions of both circumferential bellows and conventional bellows are in Fig. 13. As in (b) of this figure, noise level was higher with conventional bellows. Fig. 14 shows the comparison of peak level measured by the microphone array. The peak level between car No.

15 and No. 16 was increased by 1.4 db in the conventional bellows case. Sound pressure level (SPL) at 25m from the track is shown in Fig. 14. As can be seen, the level is increased by 0.3 db. Fig. 12 Circumferential bellows and conventional bellows 20 db (a) Circumferential (b) Conventional Fig. 13 Comparison of noise distributions with circumferential bellows and conventional bellows Inter-car Gap Peak Level (db(a)) Circumferential Bellows Conventional Bellows Sound Pressure Level (db(a)) Circumferential Bellows Conventional Bellows 260 280 300 320 340 360 380 260 280 300 320 340 360 380 Fig. 14 Comparison of peak level with circumferential and conventional bellows 3.4 Sound Absorbing Panels Fig. 15 Comparison of SPL at 25m with circumferential and conventional bellows Sound absorbing panels are applied to the lower sides and bottom of the car body to absorb the noise reflected by the roadbed and noise barriers in order to reduce noise from the lower parts, which makes a comparatively greater contribution to the overall noise level of the test trains because of their reduced pantograph noise. [1] As shown in Fig. 16, comparison was made by replacing these panels with panels that don t have sound absorbing material. The panel pattern was changed in order to find which parts of sound absorbing panels are more effective in overall noise reduction as indicated in Table 3. Fig. 17 shows sound pressure level at 25m in each case. About 0.9 db increase was observed when all the sound absorbing material was removed. From the detailed analysis, it was also found that sound absorbing panels attached to the side skirts contribute greatest to overall noise level, reducing overall noise by 0.8 db. This is because sound absorbing panels attached to side skirts greatly diminish noise from the lower parts in a multi-reflection process between car bodies and sound barriers as shown in Fig. 18. As for contributions of other parts, it was found that panels attached under the floor reduced noise slightly,while panels attached to side beams and front and back sides of bogies didn t contribute to reduce overall noise beyond that achieved with other parts of panels.

Side-skirts & side beams Under the floor Front and back sides of bogies Fig. 16 Deterioration tests for sound absorbing panels Table 3 Panel Pattern for the tests Side beam Side skirts F/B of bogies case1 O O O O case2 O O X O case3 X X X X case4 X O O X case5 X O O O Under the floor (O: Sound absorbing panel X: No sound absorbing panel) Sound Pressure Level (db(a)) case1 case2 case3 case4 case5 0.5 db 310 320 Fig. 17 SPL at 25m in 5 cases (non-directional microphone) Fig. 18 Multi-reflection process 4 Overall Performance In this chapter, overall noise performance of FASTECH360 is explained. Pantograph peak level, inter-car gap peak level, and sound pressure level at 25m of FASTECH360 are compared with those of commercial trains. Note that series E2 trains are used on Shinkansen lines,series E3 trains are used for through operations onto converted conventional lines, and trains of both types can also be coupled as FASTECH360S and 360Z can.

4.1 Pantograph Peak Level and Inter-gap Peak Level Pantograph peak level and inter-car gap peak level measured by the microphone array are shown in Fig. 19 and Fig. 20 respectively. Fig. 19 shows that the pantograph peak level of FASTECH360 is reduced by more than 2dB compared to series E2, and is reduced by more than 5dB compared to series E3. This reduction is achieved not only by pantograph noise insulation plates but also by low-noise pantographs [1]. It is also noted that the peak level of the folded pantograph is less than for the unfolded one. This is because hidden areas of the folded pantograph behind noise insulation plates are greater than those of the unfolded pantograph. Fig. 20 shows that the inter-car gap peak level of FASTECH360 is reduced by 1 to 2 db compared to series E2, and is reduced by approximately 4dB compared to series E3. This is attributed to the noise reduction effect of smoothed roof, circumferential bellows, and sound absorbing panels as described in chapter 3. Sound absorbing panels were especially effective when running on slab track. It is also remarkable that the noise reduction effect of FASTECH360S is greater than that of FASTECH360Z. This is due to the larger size of countermeasures applied on FASTECH360S as described above. Peak Level (db(a)) 1 db 360Z (up) 360Z (dow n) 360S (up) 360S (dow n) E3 (up) E2 (up) 240 260 280 300 320 340 360 380 240 260 280 300 320 340 360 380 Fig.19 Pantograph peak level (microphone array) 4.2 Sound Pressure Level at 25m Fig. 20 Inter-car gap peak level (microphone array) Fig. 21 shows sound pressure level measured by non-directional microphone. The noise level of FASTECH360S+360Z (coupled) is 4 to 5 db less than that of E3+E2 (coupled), and the difference reaches 6 db when it comes to FASTECH360S (alone). In other words, the train speed at which the noise level is the same as current commercial trains running at the speed of 275 km/h is about 330 km/h for FASTECH360S+360Z (coupled), and is about 340km/h for FASTECH360S (alone). Although the goal 360km/h is still ahead, it was confirmed that countermeasures incorporated in FASTECH360 greatly reduce wayside noise and contribute to environmental friendliness. Peak Level (db(a)) 1 db 360Z E3 360S E2 Sound Pressure Level (db(a)) 1 db 360S+Z (coupled) 360S (alone) E3+E2 (coupled) E2 (alone) 240 260 280 300 320 340 360 380 Fig. 21 SPL at 25m (non-directional microphone)

5. Conclusions (1) The train speed at which the noise level is the same as current commercial trains running at the speed of 275 km/h is about 330 km/h for FASTECH360S+360Z (coupled), and is about 340km/h for FASTECH360S (alone). (2) Pantograph noise insulation plates reduce wayside noise by about 1.5 db. In combination with low-noise pantographs, they reduce pantograph peak level by about 2 to 5 db compared to current commercial trains. (3) Smoothed roof, circumferential bellows, and sound absorbing panels are also of use to reduce wayside noise. Combined together, inter-car gap peak level is reduced by about 2 to 4 db compared to current commercial trains. References [1] A.Ido, T.Kurita, Y.Wakabayashi, M.Hara, H.Shiraishi, M.Horiuchi, Development of Technologies for Minimizing Environmental Impacts, Proceedings of 7 th World Congress on Railway Research, 2006/6 [2] Y.Wakabayashi, T.Kurita, H.Yamada, M.Horiuchi, Noise measurement results of Shinkansen high-speed test train (FASTECH360S,Z), Proceedings of 9 th International Workshop on Railway Noise, 2007/8 [3] Y.Takano, K.Sasaki, T.Satoh, K.Murata, H.Mae, J.Gotoh, Development of Visualization System for High-speed Noise Source with a Microphone Array and a Visual Sensor, Proceedings of Inter-Noise 2003, N930, 2003/8