Configuring the Fabric Interconnects



Similar documents
Direct Attached Storage

Network Load Balancing

Configuring the Switch with the CLI-Based Setup Program

Configuring the Switch with the CLI Setup Program

Configuring the Switch IP Address and Default Gateway

PassTest. Bessere Qualität, bessere Dienstleistungen!

Deployment Guide: Transparent Mode

CCT vs. CCENT Skill Set Comparison

Using Cisco UC320W with Windows Small Business Server

Mobility System Software Quick Start Guide

Load Balancing ContentKeeper With RadWare

Configuring Trend Micro Content Security

Deploying Windows Streaming Media Servers NLB Cluster and metasan

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA

Monitoring the Switch

: Interconnecting Cisco Networking Devices Part 1 v2.0 (ICND1)

Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials.

ASUS WL-5XX Series Wireless Router Internet Configuration. User s Guide

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

FSM73xx GSM73xx GMS72xxR Shared access to the Internet across Multiple routing VLANs using a Prosafe Firewall

Chapter 1 Configuring Basic Connectivity

Networking Guide Redwood Manager 3.0 August 2013

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

IP-6600 Router Configuration Quickstart Backing Up a Broadband Connection with Dialup

Adding Traffic Sources to a Monitoring Session, page 7 Activating a Traffic Monitoring Session, page 8 Deleting a Traffic Monitoring Session, page 9

Monitoring Traffic. Traffic Monitoring. This chapter includes the following sections:

Configuring Network Load Balancing for vethernet

CounterACT 7.0 Single CounterACT Appliance

Management Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version Rev. B

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Setting the Management IP Address

Cisco Certified Network Associate Exam. Operation of IP Data Networks. LAN Switching Technologies. IP addressing (IPv4 / IPv6)

Configuring Switch Ports and VLAN Interfaces for the Cisco ASA 5505 Adaptive Security Appliance

Lab - Using IOS CLI with Switch MAC Address Tables

Intel Active Management Technology with System Defense Feature Quick Start Guide

Starting a Management Session

1. Hardware Installation

If you have any problems, please contact our technical support team at , or

Installing and Using the vnios Trial

Configuring DHCP Snooping

Chapter 3 Management. Remote Management

Virtual PortChannel Quick Configuration Guide

"Charting the Course...

Debugging Network Communications. 1 Check the Network Cabling

Lab Configuring Access Policies and DMZ Settings

Interconnecting Cisco Networking Devices, Part 1 (ICND1) v3.0

N300 WiFi Range Extender WN2000RPT User Manual

Savvius Insight Initial Configuration

ProSafe Plus Switch Utility

Citrix XenServer Design: Designing XenServer Network Configurations

Layer 3 Routing User s Manual

ProSAFE 8-Port and 16-Port Gigabit Click Switch

Interconnecting Cisco Networking Devices Part 2

Steps for Basic Configuration

Cisco Nexus 5548UP. Switch Configuration Guide for Dell PS Series SANs. A Dell Deployment and Configuration Guide

138 Configuration Wizards

How To Learn Cisco Cisco Ios And Cisco Vlan

vsphere Networking ESXi 5.0 vcenter Server 5.0 EN

Abstract. MEP; Reviewed: GAK 10/17/2005. Solution & Interoperability Test Lab Application Notes 2005 Avaya Inc. All Rights Reserved.

LotWan Appliance User Guide USER GUIDE

Read Me First for the HP ProCurve Routing Switch 9304M and Routing Switch 9308M

TotalCloud Phone System

Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches

1 Basic Configuration of Cisco 2600 Router. Basic Configuration Cisco 2600 Router

A Dell Technical White Paper Dell Storage Engineering

Configuring the Transparent or Routed Firewall

IP Addressing and Subnetting. 2002, Cisco Systems, Inc. All rights reserved.

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

AT-S60 Version Management Software for the AT-8400 Series Switch. Software Release Notes

M6100, M5300, and M7100 Series Switches Software Setup Manual

Chapter 1 Installing the Gateway

SOHO 6 Wireless Installation Procedure Windows 95/98/ME with Internet Explorer 5.x & 6.0

Linksys WAP300N. User Guide

Quick Start Guide. WRV210 Wireless-G VPN Router with RangeBooster. Cisco Small Business

Easy Setup Guide for the Sony Network Camera

NBG2105. User s Guide. Quick Start Guide. Wireless Mini Travel Router. Default Login Details. Version 1.00 Edition 1, 11/2012

Unified Access Point Administrator's Guide

Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide

Prestige 324 Quick Start Guide. Prestige 324. Intelligent Broadband Sharing Gateway. Version V3.61(JF.0) May 2004 Quick Start Guide

Chapter 1 Configuring Internet Connectivity

High Availability Failover Optimization Tuning HA Timers PAN-OS 6.0.0

Course. Contact us at: Information 1/8. Introducing Cisco Data Center Networking No. Days: 4. Course Code

Configure IOS Catalyst Switches to Connect Cisco IP Phones Configuration Example

Configuring Windows Server Clusters

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

Bits per Second Data Bits Parity Stop Bits Flow Control None 1 None

Installing the Cisco Nexus 1000V for Microsoft Hyper-V

Quick Start for Network Agent. 5-Step Quick Start. What is Network Agent?

ADMINISTRATION GUIDE Cisco Small Business

How To Understand and Configure Your Network for IntraVUE

GS510TP and GS110T Gigabit Smart Switches

Quick Start Guide. 500 Series Stackable Managed Switches

1-Port Wireless USB 2.0 Print Server Model # APSUSB201W. Quick Installation Guide. Ver. 2A

Interconnecting Cisco Network Devices 1 Course, Class Outline

CCNP SWITCH: Implementing High Availability and Redundancy in a Campus Network

High Availability. FortiOS Handbook v3 for FortiOS 4.0 MR3

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

Virtual PortChannels: Building Networks without Spanning Tree Protocol

CT5760 Controller and Catalyst 3850 Switch Configuration Example

Transcription:

Configuring the Fabric Interconnects This chapter includes the following sections: Initial System Setup, page 1 Performing an Initial System Setup for a Standalone Configuration, page 3 Initial System Setup for a Cluster Configuration, page 5 Enabling a Standalone Fabric Interconnect for Cluster Configuration, page 8 Ethernet Switching Mode, page 8 Configuring Ethernet Switching Mode, page 9 Aging Time for the MAC Address Table, page 10 Configuring the Aging Time for the MAC Address Table, page 10 Initial System Setup The first time that you access a fabric interconnect in a Cisco UCS instance, a setup wizard prompts you for the following information required to configure the system: Installation method (GUI or CLI) Setup mode (restore from full system backup or initial setup) System configuration type (standalone or cluster configuration) System name Admin password Management port IP address and subnet mask Default gateway IP address DNS Server IP address Default domain name OL-21677-02 1

Initial System Setup Setup Mode Setup Mode System Configuration Type You can choose to either restore the system configuration from an existing backup file, or manually setup the system by going through the setup wizard. If you choose to restore the system, the backup file must be reachable from the management network. You can configure a Cisco UCS instance to use a single fabric interconnect in a standalone configuration or to use a redundant pair of fabric interconnects in a cluster configuration. A cluster configuration provides high availability. If one fabric interconnect becomes unavailable, the other takes over. Only one management port (Mgmt0) connection is required to support a cluster configuration; however, both Mgmt0 ports should be connected to provide link-level redundancy. Note The cluster configuration only provides redundancy for the management plane. Data redundancy is dependent on the user configuration and may require a third-party tool to support data redundancy. To use the cluster configuration, the two fabric interconnects must be directly connected together using Ethernet cables between the L1 (L1-to-L1) and L2 (L2-to-L2) high availability ports, with no other fabric interconnects in between. This allows the two fabric interconnects to continuously monitor the status of each other and quickly know when one has failed. Both fabric interconnects in a cluster configuration must go through the initial setup process. The first fabric interconnect to be setup must be enabled for a cluster configuration, then when the second fabric interconnect is setup, it detects the first fabric interconnect as a peer fabric interconnect in the cluster. For more information, refer to the Cisco UCS 6100 Series Fabric Interconnect Hardware Installation Guide. Management Port IP Address In a standalone configuration, you must specify only one IP address and the subnet mask for the single management port on the fabric interconnect. In a cluster configuration, you must specify the following three IP addresses in the same subnet: Management port IP address for fabric interconnect A Management port IP address for fabric interconnect B Cluster IP address Tip After the initial configuration, you can change the management IP port and the related subnet mask in the Cisco UCS Manager CLI. You cannot make this change in the Cisco UCS Manager GUI. 2 OL-21677-02

Configuring the Fabric Interconnects Performing an Initial System Setup for a Standalone Configuration Performing an Initial System Setup for a Standalone Configuration Before You Begin 1 Verify the following physical connections on the fabric interconnect: The console port is physically connected to a computer terminal or console server The management Ethernet port (mgmt0) is connected to an external hub, switch, or router For more information, refer to the Cisco UCS Hardware Installation Guide for your fabric interconnect. 2 Verify that the console port parameters on the computer terminal (or console server) attached to the console port are as follows: 9600 baud 8 data bits No parity 1 stop bit 3 Collect the following information that you will need to supply during the initial setup: System name. Password for the admin account. Choose a strong password with at least one capital letter and one number. This password cannot be blank. Management port IP address and subnet mask. Default gateway IP address. DNS server IP address (optional). Domain name for the system (optional). Connect to the console port. Power on the fabric interconnect. OL-21677-02 3

Performing an Initial System Setup for a Standalone Configuration Configuring the Fabric Interconnects You will see the power on self-test messages as the fabric interconnect boots. Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 0 1 2 3 4 5 6 7 When the unconfigured system boots, it prompts you for the setup method to be used. Enter console to continue the initial setup using the console CLI. Enter setup to continue as an initial system setup. Enter y to confirm that you want to continue the initial setup. Enter the password for the admin account. To confirm, re-enter the password for the admin account. Enter no to continue the initial setup for a standalone configuration. Enter the system name. Enter the IP address for the management port on the fabric interconnect. Enter the subnet mask for the management port on the fabric interconnect. Enter the IP address for the default gateway. Enter yes if you want to specify the IP address for the DNS server, or no if you do not. (Optional) Enter the IP address for the DNS server. Enter yes if you want to specify the default domain name, or no if you do not. (Optional) Enter the default domain name. Review the setup summary and enter yes to save and apply the settings, or enter no to go through the setup wizard again to change some of the settings. If you choose to go through the setup wizard again, it provides the values you previously entered, and the values appear in brackets. To accept previously entered values, press the Enter key. The following example sets up a standalone configuration using the console: Enter the installation method (console/gui)? console Enter the setup mode (restore from backup or initial setup) [restore/setup]? setup You have chosen to setup a new switch. Continue? (y/n): y Enter the password for "admin": adminpassword%958 Confirm the password for "admin": adminpassword%958 Do you want to create a new cluster on this switch (select 'no' for standalone setup or if you want this switch to be added to an existing cluster)? (yes/no) [n]: no Enter the system name: foo Mgmt0 IPv4 address: 192.168.10.10 Mgmt0 IPv4 netmask: 255.255.255.0 IPv4 address of the default gateway: 192.168.10.1 Configure the DNS Server IPv4 address? (yes/no) [n]: yes DNS IPv4 address: 20.10.20.10 Configure the default domain name? (yes/no) [n]: yes Default domain name: domainname.com Following configurations will be applied: Switch Fabric=A System Name=foo Management IP Address=192.168.10.10 Management IP Netmask=255.255.255.0 Default Gateway=192.168.10.1 DNS Server=20.10.20.10 Domain Name=domainname.com Apply and save the configuration (select 'no' if you want to re-enter)? (yes/no): yes 4 OL-21677-02

Performing an Initial System Setup for the First Fabric Interconnect Initial System Setup for a Cluster Configuration Initial System Setup for a Cluster Configuration Performing an Initial System Setup for the First Fabric Interconnect Before You Begin 1 Verify the following physical connections on the fabric interconnect: A console port on the first fabric interconnect is physically connected to a computer terminal or console server The management Ethernet port (mgmt0) is connected to an external hub, switch, or router The L1 ports on both fabric interconnects are directly connected to each other The L2 ports on both fabric interconnects are directly connected to each other For more information, refer to the Cisco UCS Hardware Installation Guide for your fabric interconnect. 2 Verify that the console port parameters on the computer terminal (or console server) attached to the console port are as follows: 9600 baud 8 data bits No parity 1 stop bit 3 Collect the following information that you will need to supply during the initial setup: System name. Password for the admin account. Choose a strong password with at least one capital letter and one number. This password cannot be blank. Three static IP addresses: two for the management port on both fabric interconnects (one per fabric interconnect), and one for the cluster IP address used by Cisco UCS Manager. Subnet mask for the three static IP addresses. Default gateway IP address. DNS server IP address (optional). Domain name for the system (optional). Connect to the console port. Power on the fabric interconnect. OL-21677-02 5

Initial System Setup for a Cluster Configuration Configuring the Fabric Interconnects You will see the power on self-test messages as the fabric interconnect boots. Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 0 1 2 3 4 5 6 7 8 9 When the unconfigured system boots, it prompts you for the setup method to be used. Enter console to continue the initial setup using the console CLI. Enter setup to continue as an initial system setup. Enter y to confirm that you want to continue the initial setup. Enter the password for the admin account. To confirm, re-enter the password for the admin account. Enter yes to continue the initial setup for a cluster configuration. Enter the fabric interconnect fabric (either A or B). Enter the system name. Enter the IP address for the management port on the fabric interconnect. Enter the subnet mask for the management port on the fabric interconnect. Enter the IP address for the default gateway. Enter the virtual IP address. Enter yes if you want to specify the IP address for the DNS server, or no if you do not. (Optional) Enter the IP address for the DNS server. Enter yes if you want to specify the default domain name, or no if you do not. (Optional) Enter the default domain name. Review the setup summary and enter yes to save and apply the settings, or enter no to go through the setup wizard again to change some of the settings. If you choose to go through the setup wizard again, it provides the values you previously entered, and the values appear in brackets. To accept previously entered values, press the Enter key. The following example sets up the first fabric interconnect for a cluster configuration using the console: Enter the installation method (console/gui)? console Enter the setup mode (restore from backup or initial setup) [restore/setup]? setup You have chosen to setup a new switch. Continue? (y/n): y Enter the password for "admin": adminpassword%958 Confirm the password for "admin": adminpassword%958 Do you want to create a new cluster on this switch (select 'no' for standalone setup or if you want this switch to be added to an existing cluster)? (yes/no) [n]: yes Enter the switch fabric (A/B): A Enter the system name: foo Mgmt0 IPv4 address: 192.168.10.10 Mgmt0 IPv4 netmask: 255.255.255.0 IPv4 address of the default gateway: 192.168.10.1 Virtual IPv4 address : 192.168.10.12 Configure the DNS Server IPv4 address? (yes/no) [n]: yes DNS IPv4 address: 20.10.20.10 Configure the default domain name? (yes/no) [n]: yes Default domain name: domainname.com Following configurations will be applied: Switch Fabric=A System Name=foo Management IP Address=192.168.10.10 Management IP Netmask=255.255.255.0 Default Gateway=192.168.10.1 Cluster Enabled=yes Virtual Ip Address=192.168.10.12 DNS Server=20.10.20.10 Domain Name=domainname.com Apply and save the configuration (select 'no' if you want to re-enter)? (yes/no): yes 6 OL-21677-02

Performing an Initial System Setup for the Second Fabric Interconnect Initial System Setup for a Cluster Configuration Performing an Initial System Setup for the Second Fabric Interconnect Before You Begin 1 Verify the following physical connections on the fabric interconnect: A console port on the second fabric interconnect is physically connected to a computer terminal or console server The management Ethernet port (mgmt0) is connected to an external hub, switch, or router The L1 ports on both fabric interconnects are directly connected to each other The L2 ports on both fabric interconnects are directly connected to each other For more information, refer to the Cisco UCS Hardware Installation Guide for your fabric interconnect. 2 Verify that the console port parameters on the computer terminal (or console server) attached to the console port are as follows: 9600 baud 8 data bits No parity 1 stop bit 3 Collect the following information that you will need to supply during the initial setup: Password for the admin account of the peer fabric interconnect Management port IP address in the same subnet as the peer fabric interconnect Step 3 Step 4 Step 5 Step 6 Step 7 Connect to the console port. Power on the fabric interconnect. You will see the power on self-test messages as the fabric interconnect boots. When the unconfigured system boots, it prompts you for the setup method to be used. Enter console to continue the initial setup using the console CLI. Note The fabric interconnect should detect the peer fabric interconnect in the cluster. If it does not, check the physical connections between the L1 and L2 ports, and verify that the peer fabric interconnect has been enabled for a cluster configuration. Enter y to add the subordinate fabric interconnect to the cluster. Enter the admin password of the peer fabric interconnect. Enter the IP address for the management port on the subordinate fabric interconnect. Review the setup summary and enter yes to save and apply the settings, or enter no to go through the setup wizard again to change some of the settings. If you choose to go through the setup wizard again, it provides the values you previously entered, and the values appear in brackets. To accept previously entered values, press the Enter key. OL-21677-02 7

Enabling a Standalone Fabric Interconnect for Cluster Configuration Configuring the Fabric Interconnects The following example sets up the second fabric interconnect for a cluster configuration using the console: Enter the installation method (console/gui)? console Installer has detected the presence of a peer switch. This switch will be added to the cluster. Continue?[y/n] y Enter the admin password of the peer switch: adminpassword%958 Mgmt0 IPv4 address: 192.168.10.11 Management Ip Address=192.168.10.11 Apply and save the configuration (select 'no' if you want to re-enter)? (yes/no): yes Enabling a Standalone Fabric Interconnect for Cluster Configuration You can add a second fabric interconnect to an existing Cisco UCS instance that uses a single standalone fabric interconnect. To do this, you must enable the standalone fabric interconnect for cluster operation, and then add the second fabric interconnect to the cluster. Command or Action UCS-A# connect local-mgmt UCS-A(local-mgmt) # enable cluster ip-addr Purpose Enters local management mode. Enables cluster operation on the standalone fabric interconnect with the specified IP address. When you enter this command, you are prompted to confirm that you want to enable cluster operation. Type yes to confirm. The following example enables a standalone fabric interconnect with IP address 192.168.1.101 for cluster operation: UCS-A# connect local-mgmt UCS-A(local-mgmt)# enable cluster 192.168.1.101 This command will enable cluster mode on this setup. You cannot change it back to stand-alone. Are you sure you want to continue? (yes/no): yes UCS-A(local-mgmt)# What to Do Next Add the second fabric interconnect to the cluster. Ethernet Switching Mode The Ethernet switching mode determines how the fabric interconnect behaves as a switching device between the servers and the network. The fabric interconnect operates in either of the following Ethernet switching modes: End-Host Mode End-host mode allows the fabric interconnect to act as an end host to the network, representing all server (hosts) connected to it through vnics. This is achieved by pinning (either dynamically pinned or hard pinned) vnics to uplink ports, which provides redundancy toward the network, and makes the uplink ports appear as 8 OL-21677-02

Configuring the Fabric Interconnects Configuring Ethernet Switching Mode server ports to the rest of the fabric. When in end-host mode, the fabric interconnect does not run the Spanning Tree Protocol (STP) and avoids loops by denying uplink ports from forwarding traffic to each other, and by denying egress server traffic on more than one uplink port at a time. End-host mode is the default Ethernet switching mode and should be used if either of the following are used upstream: Layer 2 switching for L2 Aggregation Virtual Switching System (VSS) aggregation layer Note When end-host mode is enabled, if a vnic is hard pinned to an uplink port and this uplink port goes down, the system cannot re-pin the vnic, and the vnic remains down. Switch Mode Switch mode is the traditional Ethernet switching mode. The fabric interconnect runs STP to avoid loops, and broadcast and multicast packets are handled in the traditional way. Switch mode is not the default Ethernet switching mode, and should be used only if the fabric interconnect is directly connected to a router, or if either of the following are used upstream: Layer 3 aggregation VLAN in a box Note For both Ethernet switching modes, even when vnics are hard pinned to uplink ports, all server-to-server unicast traffic in the server array is sent only through the fabric interconnect and is never sent through uplink ports. Server-to-server multicast and broadcast traffic is sent through all uplink ports in the same VLAN. Configuring Ethernet Switching Mode Important When you change the Ethernet switching mode, Cisco UCS Manager logs you out and restarts the fabric interconnect. For a cluster configuration, Cisco UCS Manager restarts both fabric interconnects sequentially. The second fabric interconnect can take several minutes to complete the change in Ethernet switching mode and become system ready. Command or Action UCS-A# scope eth-uplink UCS-A /eth-uplink # set mode {end-host switch} Purpose Enters Ethernet uplink mode. Sets the fabric interconnect to the specified switching mode. OL-21677-02 9

Aging Time for the MAC Address Table Configuring the Fabric Interconnects Step 3 Command or Action UCS-A /eth-uplink # commit-buffer Purpose Commits the transaction to the system configuration. The following example sets the fabric interconnect to end-host mode and commits the transaction: UCS-A# scope eth-uplink UCS-A /eth-uplink # set mode end-host Warning: When committed, this change will cause the switch to reboot UCS-A /eth-uplink* # commit-buffer UCS-A /eth-uplink # Aging Time for the MAC Address Table To efficiently switch packets between ports, the fabric interconnect maintains a MAC address table. It dynamically builds the MAC address table by using the MAC source address from the packets received and the associated port on which the packets were learned. The fabric interconnect uses an aging mechanism, defined by a configurable aging timer, to determine how long an entry remains in the MAC address table. If an address remains inactive for a specified number of seconds, it is removed from the MAC address table. You can configure the amount of time (age) that a MAC address entry (MAC address and associated port) remains in the MAC address table. Configuring the Aging Time for the MAC Address Table Step 3 Command or Action UCS-A# scope eth-uplink UCS-A /eth-uplink # set mac-aging {seconds mode-default never} UCS-A /eth-uplink # commit-buffer Purpose Enters Ethernet uplink mode. Specifies the aging time for the MAC address table. Use the mode-default keyword to set the aging time to a default value dependent on the configured Ethernet switching mode. For end-host mode, the default aging time is 7,200 seconds; for switch mode, the default aging time is 300 seconds. Use the never keyword to never remove MAC addresses from the table regardless of how long they have been idle. Commits the transaction to the system configuration. The following example sets the aging time for the MAC address table to 10,000 seconds and commits the transaction: UCS-A# scope eth-uplink UCS-A /eth-uplink # set mac-aging 10000 UCS-A /eth-uplink* # commit-buffer UCS-A /eth-uplink # 10 OL-21677-02