Make a more confident glaucoma risk assessment with Corneal Hysteresis, a superior predictor of glaucoma progression.



Similar documents
Managing glaucoma is a. Glaucoma Management Edited by Kuldev Singh, MD, MPH, and Peter A. Netland, MD, PhD. Thickness and Hysteresis

How do you adjust for IOP in a LASIK patient?

Measure of Confidence. Glaucoma Module Premium Edition

Using Biomechanics to Advance Glaucoma Care

LOCSU Enhanced Services

Phoroptor VRx Digital Refraction System

CORNEAL HYSTERESIS AND INTRAOCULAR PRESSURE MEASUREMENT

CORNEAL HYSTERESIS AND INTRAOCULAR PRESSURE MEASUREMENT

11/11/2015. Glaucoma: Diagnosis and Treatment. Financial disclosures. Glaucoma: the problem. Joshua J. Ney, M.D. No disclosures to report

Archive of SID. Primary Open Angle Glaucoma and Post-LASIK Keratectasia. Challenging Case

Contact Lens & Anterior Eye

Guidance for Industry and FDA Staff Tonometers - Premarket Notification [510(k)] Submissions

LOCSU / WOPEC courses to support local service development

Glaucoma. OET: Reading Part A. Reading Sub-test. Complete the following summary using the information in the four texts provided.

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

Abstract. Received 13 March 2014; revised 15 April 2014; accepted 6 May 2014

September 17, Keeler Instruments Inc. Mr. Eugene R. Van Arsdale Marketing Manager 459 Parkway Broomall, PA 19008

femtosecond laser platform Exceptional versatility without compromise

Framingham Cardiovascular Risk Calculator 1998

Unilateral Corneal Ectasia after Bilateral LASIK: The Thick Flap Counts

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

A new level of insight and accuracy

ALL-IN-ONE Optical Biometry, Dual Scheimpflug Tomography and Placido Topography

Trends in Ophthalmology a Market Perspective. Matthias Karl, Michael Kempe

Optic Nerve Imaging. Management of Glaucoma

Glaucoma. Quick reference guide. Issue date: April Diagnosis and management of chronic open angle glaucoma and ocular hypertension

Evaluation of the Orssengo-Pye IOP corrective algorithm in LASIK patients with thick corneas

Tonometry after Laser in Situ Keratomileusis Treatment: A Preliminary Study in Thai Patients

Underestimation of Intraocular Pressure in Eyes After Laser In Situ Keratomileusis

T O N O M E T E R. Transpalpebral scleral tonometry COLLECTED ARTICLES. edition 4

Evaluation of the ICare Rebound Tonometer as a Home Intraocular Pressure Monitoring Device

Visual Field Analyzers from Carl Zeiss. Expanding your field of vision

SLIT LAMP BQ 900 Sophisticated microscopy

D Gentle for the newborn, efficient for you. DRÄGER JAUNDICE METER JM-105

Contact Lens & Anterior Eye

COMPARISON OF DYNAMIC CONTOUR TONOMETRY (PASCAL ) WITH PNEUMOTONOMETRY AND GOLDMANN TONOMETRY

Reduction in Intraocular Pressure after Cataract Extraction: The Ocular Hypertension Treatment Study

Tonometry Past, Present and Future

Glaucoma: diagnosis and management of chronic open angle glaucoma and ocular hypertension

Ziemer GALILEI Experts Meeting. American Academy of Ophthalmology Orlando, Florida 1

IOLMaster 500. Excellence in Biometry. Precision. Simplicity. Outcomes.

Tono-Pen AVIA Tonometer

Comparison of Retinal Image Quality between SBK and PRK. Allen Boghossian, D.O. Durrie Vision Overland Park, KS

Reliability of Corneal Dynamic Scheimpflug Analyser Measurements in Virgin and Post-PRK Eyes

Short-term variation in central corneal thickness and intraocular pressure using the Tono- Pachymeter NT530P (Tonopachy )

INFLUENCE OF WOUND HEALING PROCESS AT THE FLAP EDGE ON THE BIOMECHANICAL PROPERTIES OF THE CORNEA AFTER LASIK. ORA AND CONFOCAL STUDY

Assessing the Accuracy of the Technology-based Eye Care Services (TECS) Protocol to a Standard Clinical Ophthalmic Exam

LIVING WITH GLAUCOMA Volume 29, Number 1

INTRODUCTION. Ş. BAYRAKTAR 1 ' 2, Z. BAYRAKTAR 2 Istanbul Surgery Hospital, Istanbul 2. BeyogIu Eye Education and Research Hospital, Istanbul - Turkey

Dynamic Contour Tonometry

Smallest design. Biggest impression. Impressively thin. Retractability. See more of your patient. See more patients. Thinnest Phoroptor yet.

~Contributing to Eye Health~

SCHWIND eye-tech-solutions installs the 1,000 th eye laser

Do You STILL Need Technology? DO YOU STILL TECHNOLOGY? The Challenges in The Challenges in FEC s Production Reports 2012

Clinical Characteristics of Glaucomatous Subjects Treated with Refractive Corneal Ablation Surgery

GENERAL CODING INFORMATION. Use of Modifiers for Identifying Specific Eye

BSM Connection elearning Course

OCTOPUS 300 Perimetry you can trust

Tonometric Changes of Latanoprost-Induced Intraocular Pressure Reduction after Photorefractive Keratectomy MATERIALS AND METHODS.

Early Transient Visual Acuity Loss After LASIK Due to Steroid-induced Elevation of Intraocular Pressure

Glaucoma. The sneak thief of sight

JON MARTIN RUDERMAN CURRICULUM VITAE

Curriculum for the Glaucoma EBO-EGS Subspecialty exam/diploma (Glaucoma-medical)

Goldmann applanation tonometry (GAT) is the standard for

ABrand New Refraction Meas urement Instrument

Eye and Vision Care in the Patient-Centered Medical Home

Epi-LASIK Surgery. The procedure of choice for surface ablation.

MODERN CLINICAL OPTOMETRY BILLING & CODING THE MEDICAL EYE EXAMINATION. Definitions of Eye Examinations. Federal Government Definition

Product Information Sheet UH36 Hi Pot Tester

The «three-in-one» Microkeratome for traditional LASIK, EPI-LASIK, and anterior and posterior Lamellar Keratoplasty

Understanding Visual Fields, Part III; Which Field Should Be Performed?

Different Clinical Parameters to Diagnose Glaucoma Disease: A Review

Medico-Legal Considerations and Coding and Billing of Laser Procedures. Marcus G. Piccolo, OD

Principles of Ophthalmic Nursing Unit Outline

DISTANCE LEARNING COURSE. Anatomy of the Patient Exam , BSM Consulting All rights reserved.

Initial clinical experience with the FS200 Femto and EX500 excimer

Patient s Guide to Choosing Your Refractive Surgeon

Ectasia Risk Scoring System (ERSS): Limitations and Variability in Predictive Value

Complications of Combined Topography-Guided Photorefractive Keratectomy and Corneal Collagen Crosslinking in Keratoconus

Consumer s Guide to Choosing Your Refractive Surgeon

NC DIVISION OF SERVICES FOR THE BLIND POLICIES AND PROCEDURES VOCATIONAL REHABILITATION

One Focus: Ophthalmology

BACHELOR OF SCIENCE IN OPTOMETRY

T he assessment of precise intraocular pressure (IOP) is of

istent Trabecular Micro-Bypass Stent Reimbursement Guide

Diego Fernando Suárez Sierra, MD Fellow Cornea and Refractive Surgery Fellow Lens and Ocular Surface Vejarano Laser Vision Center

Tono-Pen XL Tonometer

Glaucoma - Visual Fields

Bascom Palmer Eye Institute

On behalf of the Vanderbilt University School of Medicine

The Big Data mining to improve medical diagnostics quality

CODE OF PRACTICE FOR THE SUPPLY OF CONTACT LENSES AND CONTACT LENS CARE PRODUCTS

RVG Full range imaging for diagnostic confidence ROBUST DESIGN SUPERIOR ERGONOMICS NEW IMAGE PROCESSING TOOLS ENHANCED WORKFLOW

POSITION PAPER November 2011 IMPROVING ACCESS TO MODERN CATARACT SURGERY IN EUROPE THROUGH EXPANDING PATIENT CHOICE. Page 1 of 8

Welcome to our Office!

FIRST EXPERIENCE WITH THE ZEISS FEMTOSECOND SYSTEM IN CONJUNC- TION WITH THE MEL 80 IN THE US

Veraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.

Professional CAD System

How To Understand The Current Of An Optic Nerve Fiber Layer

Experience and Quality Assurance MES Vision Provider Network nationwide Four

Transcription:

Make a more confident glaucoma risk assessment with Corneal Hysteresis, a superior predictor of glaucoma progression. Advancing Eye Care. American Innovation.

Reichert Ocular Response Analyzer G3. Make a more confident glaucoma risk assessment, with Corneal Hysteresis. Ocular Response Analyzer (ORA) is the only tonometer that measures Corneal Hysteresis (CH), a superior predictor of glaucoma progression. Corneal Hysteresis is an indication of the biomechanical properties of the cornea differing from thickness or topography, which are geometrical attributes. CH measurements were significantly associated with risk of glaucoma progression. Eyes with lower CH had faster rates of visual field loss than those with higher CH. 1 In addition to Corneal Hysteresis, Ocular Response Analyzer provides Corneal Compensated Intraocular Pressure (IOPcc), a better indication of the true pressure, proven to be less influenced by corneal properties than Goldmann or other methods of tonometry. 2 Effective January 1, 2015, CPT Code 92145, was published specifically for the Corneal Hysteresis measurement provided by Ocular Response Analyzer.

Ocular Response Analyzer G3

Corneal Hysteresis (CH): An indispensable tool in the glaucoma decision making process. Corneal Hysteresis has consistently shown to be predictive of, or strongly associated with, glaucoma progression, and more powerfully so, than key indicators such as IOP and CCT, making it an indispensable tool in the glaucoma decision making process. Glaucoma is the second leading cause of irreversible blindness in the world. Despite the fact that there are a variety of wellknown risk factors, it can be difficult to diagnose. Beyond diagnosing, predicting an individual patient s rate of future glaucoma progression is often extremely challenging for clinicians. The Ocular Hypertension Treatment Study (OHTS), and similar studies, have brought to light the relevance of central corneal thickness (CCT) in glaucoma. Numerous studies utilizing the Ocular Response Analyzer have confirmed the importance of the cornea in glaucoma decision making and, in fact, demonstrated that Corneal Hysteresis is of far greater significance than CCT. A comparison between the effects of CH and CCT revealed that although CH explained 17.4% of the variation in the rates of progression, CCT explained only 5.2%. 1

Corneal Compensated IOP (IOPcc): Less affected by corneal properties. Ocular Response Analyzer takes corneal biomechanical properties into consideration, providing Corneal Compensated IOP (IOPcc). The patented bi-directional applanation system enables the measurement of Corneal Hysteresis and IOPcc. Intraocular pressure (IOP) is the only modifiable risk factor for glaucoma. As such, accurate measurement of IOP is critical for proper diagnosis and management. However, it is widely recognized that Goldmann and other tonometers are influenced by corneal properties. While corneal thickness has been accepted as an important factor contributing to the accuracy of IOP measurements, it has been shown that attempting to adjust IOP values by means of a corneal thickness correction formula does not add any value to the glaucoma decision making process. It is biomechanics, not thickness, that predominantly influence the accuracy of IOP measurements. Corneal biomechanical properties can affect the accuracy of measured IOP values by as much as 17 mmhg in normal eyes 3 and more than 20 mmhg in eyes with corneal pathology. 4 IOPcc effectively eliminates these influences on the pressure measurement. Correction nomograms that adjust GAT IOP based solely on CCT are neither valid nor useful in individual patients. 5 Bi-directional applanation system. Compensated IOP (IOPcc) - a pressure measurement that is less affected by the cornea than other methods of tonometry. IOPcc is patented technology, exclusive to Reichert. - IOPcc is less affected by corneal properties than Goldmann 2 - IOPcc is a better indicator of glaucomatous damage than Goldmann tonometry 6

How is Corneal Hysteresis measured? Corneal Hysteresis is the difference in the inward and outward pressure values obtained during the patented dynamic bi-directional applanation process utilized by the Ocular Response Analyzer. It is a characterization of the cornea s ability to absorb and dissipate energy, which is a function of visco-elastic biomechanical properties of the cornea. Unparalleled user experience. Measurements could not be quicker or simpler with Ocular Response Analyzer G3. A single touch of the intuitive user interface initiates a fully automated alignment and measurement, simultaneously displaying Corneal Compensated IOP (IOPcc), Corneal Hysteresis (CH), Goldmann correlated IOP (IOPg), and Waveform Score (WS). Confidence, reliability and efficiency. The advanced, patent-pending Waveform Score feature, combined with Reichert s unique intelligent averaging technique, enhances measurement reliability and repeatability so operators can be confident in the accuracy of the measurement results. Operators can easily access all functions through the integrated touch screen display, including export of patient data for effortless EMR integration. Delegate your tonometry and Corneal Hysteresis measurements to trained technicians with ease.

Non-contact saves time and money. Because the Ocular Response Analyzer G3 measurement is rapid and non-contact the use of topical anesthesia and/or fluorescein drops is not required, saving time and money. In addition, the risk of cross contamination is greatly reduced. The need for timeconsuming sterilization of tonometer prisms, costly replacement of prisms, or use of expensive disposables is eliminated. Unique design with patients in mind. Ocular Response Analyzer G3 is designed with no chinrest, which saves time by simplifying patient positioning. This unique design also makes patients more comfortable and less intimidated by not feeling confined in a chinrest. Patented air pulse, maximum comfort. Reichert s automatic, non-linear pressure ramp customizes the air pulse, in real time, for each eye being measured. This patented feature enables the softest possible air pulse, ensuring maximum patient comfort. In a pediatric study conducted on children between the ages of 4-18 years old found, Overall cooperation was much better with ORA (89.8%) than with Goldmann applanation (78.7%), and all the children we questioned preferred this (ORA) technique. 7

CPT Code 92145 published for Corneal Hysteresis. A new CPT code, 92145, has been published specifically for the Corneal Hysteresis measurement provided by the Reichert Ocular Response Analyzer. In the 2015 CPT handbook, a new, permanent, Category I CPT code, 92145 (Corneal hysteresis determination, by air impulse stimulation, unilateral or bilateral, with interpretation and report), replaces the prior temporary, Category III CPT code, 0181T. The new code took effect January 1, 2015. For more information regarding CPT Code 92145, please consult your medical billing specialist. Made in the USA. Ocular Response Analyzer G3 is proudly made in the USA at our stateof-the-art world headquarters in Buffalo, New York.

Decades of Glaucoma Care Innovation. In 1959 Dr. Bernard Bernie Grolman flipped on the radio during his morning commute to American Optical, now Reichert Technologies, and heard a public service announcement about the prevalence of glaucoma. Being familiar with tonometry due to his industry experience he thought, What if I could create an instrument that eye doctors could use to help diagnose a leading cause of blindness, without touching the cornea? The need for a non-contact tonometer was so obvious, said Grolman, who would spend the next 10 years of his life designing and testing the original AO Non-Contact Tonometer. Using an air pulse with electro-optical detection to provide Goldmann-like measurements, the non-contact tonometer enabled user-friendly measurement of IOP without the need for topical anesthesia or corneal contact. Unveiled in 1971, the NCT I was the buzz of the entire industry. American Optical, now Reichert Technologies, continued to innovate on the concept, introducing generation after generation of non-contact tonometer. Fast forward to 2001, when David Luce, Ph.D., developed an advanced process capable of extracting information about corneal biomechanics from the NCT measurement signal. The Corneal Hysteresis measurement was born and the instrument that became known as the Ocular Response Analyzer was made available for sale in 2005. At long last, the topic of corneal biomechanics moved out of the laboratory and into the clinic, spawning entire new sections on conference programs and launching the subject to the forefront of the ophthalmic publication landscape. Reichert remains the world-leader in tonometry products and has become the pioneering innovator behind Corneal Hysteresis. Dr. Bernard Bernie Grolman, NCT I historical display. David Luce, Ph.D.

Ocular Response Analyzer G3 Specifications Catalog Number 16170 Dimensions 26.7 W x 50.2 H x 35.6 D cm (10.5 x 19.8 x 14 in.) Weight 10.4 kg (23 lbs) Voltage 100/240 VAC Frequency 50/60 Hz Measurement Range 7-60 mmhg (ISO 8612 tonometer standard) Communication Port RS-232 1 - Medeiros FA, Meira-Freitas D, Lisboa R, Kuang TM, Zangwill LM, Weinreb RN. Corneal hysteresis as a risk factor for glaucoma progression: a prospective longitudinal study. Ophthalmology. 2013 Aug;120(8):1533-40. 2 - Felipe A. Medeiros, MD and Robert N. Weinreb, MD. Evaluation of the Influence of Corneal Biomechanical Properties on Intraocular Pressure Measurements Using the Ocular Response Analyzer. J Glaucoma 2006;15:364 370. 3 - Liu J, Roberts CJ. Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J Cataract Refract Surg. 2005 Jan;31(1):146-55. 4 - Herbert E. Kaufman, MD. Pressure Measurement: Which Tonometer? Symposium on Glaucoma. Vol 11, number 2. 5 - Robert N. Weinreb, James D. Brandt, David Garway-Heath and Felipe Medeiros World Glaucoma Association on Intraocular Pressure; Consensus Series 4; May 5, 2007, Pg 18. 6 - Aashish Anand, MD, Carlos Gustavo De Moraes, MD, Christopher C Teng, MD, Celso Tello, MD, Jeffrey M Liebmann, MD Robert Ritch, MD. Lower Corneal Hysteresis Predicts Laterality in Asymmetric Open Angle Glaucoma, IOVS Papers in Press. Published on June 23, 2010 as Manuscript iovs.10-5580. 7 - Morita T, Shoji N, Kamiya K, Hagishima M, Fujimura F, Shimizu K. Intraocular pressure measured by dynamic contour tonometer and ocular response analyzer in normal tension glaucoma. Graefes Arch Clin Exp Ophthalmol DOI 10.1007/s00417-009-1169-4. Reichert, Reichert Technologies, and Ocular Response Analyzer are registered trademarks of Reichert, Inc. AMETEK is a registered trademark of AMETEK, Inc. CPT is a registered trademark of the American Medical Association.

Ocular Response Analyzer G3 Auto Tonometer + Corneal Hysteresis www.reichert.com/ora www.reichert.com Call Reichert at +1 716-686-4500, toll-free 1-888-849-8955, or contact your Authorized Reichert Technologies Distributor. 3362 Walden Avenue, Depew, NY 14043 USA 2015 AMETEK, Inc. & Reichert, Inc. 16170-110-Rev B