EL-USB-1-LCD Temperature Data Logger with LCD

Similar documents
EL-USB-TC-LCD Thermocouple Data Logger with LCD and USB Interface

EL-USB mA Current Loop USB Data Logger


EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

USB-500 Series Stand-Alone, Low-Cost Data Loggers

USB-500 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories

Data Logging Solutions from Lascar Electronics

DataView DVTH Data Logger for Temperature and Humidity

USER S GUIDE Humidity and Temperature USB Datalogger

SupcoLog Logger Interface Software

Data Loggers for Real Time Temperature Monitoring - WiFi

Current Monitoring Kit

Temperature Datalogger Users Manual

S P E C I F I C A T I O N F O R L I T H I U M B A T T E R Y. M o d e l : C R

User Guide. Temperature and Humidity Datalogger. Model 42280

Current Monitoring Kit QUICK START GUIDE

HOBO Single Channel Thermocouple Data Logger (UX M) Manual

Datalogger Graph Software Help

4-Channel Thermometer / Datalogger

USB-Based Temperature & Humidity Sensor

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

This datalogger is ideal for the Food Industry where process profiling is crucial to production efficiency and energy use optimisation.

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

RS DIGITAL THERMOMETER

TFA. KlimaLogg Pro. User Manual. Revision: 0.1

SNMP Web Management. User s Manual For SNMP Web Card/Box

FT-1000/GPS-N. System of remote monitoring and control of physical

PTR/DTR. Printing Thermometer Software. Software User Manual

Ron 3025 Crane Scale with 1"/25mm Display

1. SAFETY INFORMATION

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Instruction Manual. T3111 T3111L T3111P T3111Ex

Single Use USB Data Logger EBI 330-T30 / EBI 330-T85. User Manual

HOBO U14 Data Logger User Manual

Dual Laser InfraRed (IR) Thermometer

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

User Manual for CH-PFC76810

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

Wireless Data Logger Monitoring Systems

Temperature & Humidity SMS Alert Controller

User's Guide. Integrating Sound Level Datalogger. Model Introduction

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

User Manual. Humidity-Temperature Chart Recorder. Model RH520

SoundLAB Software Download Software from the Bogen website:

SMS GSM Alarm Messenger

Wireless Data Logger. Collect, Manage and Monitor Your Valuable Data via Wireless Communication. Register and Manage Remote Units by Groups

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

GX-2009 Data Logger Management Program Operator s Manual

5000V Graphical Megohmmeter Model 5070

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

HT580 User Reference Guide. Version 1.0

SA-9600 Surface Area Software Manual

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

HWg-STE HWg-STE PoE MANUAL

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Mini InfraRed Thermometer with Laser Pointer

Quick start guide smart.power smart.power smart.power

MicroLite II Release Notes

ExStik TM ph Waterproof Meters

GSM HOME SECURITY SYSTEM

Preparing Log-ic 360 USB Loggers for Use

User's Guide DylosLogger Software Version 1.6

Table of Contents Appendix 4-9

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

T0118 T2118 T3118. Instruction Manual

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

MIT510/2, MIT520/2 and MIT1020/2

Manual. CANcaseXL CANcaseXL log. Version 5.1 English

DC Electronic Loads 8500 series

GPS Vehicle and personal location tracker. User manual

3½ DIGIT VOLTMETER MODULE LED- / LCD- SERIES

Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station І

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

Drayton Digistat +2RF/+3RF

WD-AMX Water Detection Controllers

Changers Kalhuohfummi User Manual

Data Logger Basics For VFC Providers. Montana Immunization Program

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

This document is intended to make you familiar with the ServersCheck Monitoring Appliance

Solar Controller / Battery Charger User s Manual

ATL Fuel Level Sender Probes

Model UT201/202: OPERATING MANUAL. Table of Contents

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

ACR880 GPRS Portable Smart Card Terminal

SHENZHEN JUNSI ELECTRONIC CO.,LTD

USER MANUAL V5.0 ST100

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

Integrating Sound Level Meter and Datalogger

USB Smart Power Sensor

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Manual Ranging MultiMeter

Transcription:

Temperature Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery EL-USB-1-LCD BAT 3V6 1/2AA FEATURES measurement range USB interface for set-up and data download User-programmable alarm thresholds Status indication via red, green and orange LEDs High contrast LCD, with two and a half digit temperature display function Immediate, delayed and push-to-start logging Supplied with replaceable internal lithium battery and Windows control software This standalone data logger measures and stores up to 16,378 temperature readings over a range. The user can easily set up the logging rate and start-time, and download the stored data by plugging the data logger into a PC s USB port and running the purpose designed software under Windows 2000, XP, Vista, and 7. Data can then be graphed, printed and exported to other applications. The high contrast LCD can show a variety of temperature information. At the touch of a button, the user can cycle between the current, maximum and minimum stored temperatures. The data logger is supplied complete with a long-life lithium battery, which can typically allow logging for up to 1 year. The data logger is protected against moisture to IP67 standard when the protective cap is fitted. Specifications Minimum Typical Maximum Unit Measurement range -35 (-31) +80 (+176) C ( F) Internal resolution 0.5 (1) C ( F) Accuracy (overall error) ±0.5 (±1) ±1.5 (±3) C ( F) Logging rate every 10s every 12hr - Operating temperature range -35 (-31) +80 (+176) C ( F) 1/2AA 3.6V Lithium Battery life 1* Year * At 25 C and 1 minute logging rate EL-WIN-USB (CONTROL SOFTWARE) Lascar s EasyLog USB control software is supplied free of charge with each data logger. Easy to install and use, the control software runs under Windows 2000, XP, Vista & 7. The software is used to set-up the data logger as well as download, graph and export data to Excel. The software allows the following parameters to be configured: Logger name C, F Logging rate (10s, 1m, 5m, 30m, 1hr, 6hr, 12hr) High and low alarms Immediate, delayed and push-to-start logging Display off, on for 30 seconds after button press, or permanently on Data rollover (allows unlimited logging periods by overwriting the oldest data when the memory is full) The latest version of the control software may be downloaded free of charge from Specifications liable to change without prior warning Issue 4 07/2012 S.L Applies to EL-USB-1-LCD Page 1 of 5

DISPLAY AND STATUS FUNCTIONS The EL-USB-1-LCD features a high contrast LCD and two LEDs. The LCD shows logged temperature values and can also show information regarding the logging status. Maximum logged value symbol Negative symbol Minimum logged value symbol Reading Temperature scale The LCD shows three different recorded readings, which can be cycled through using the built-in push button. The most recent logged temperature, maximum logged temperature and minimum logged temperature can be displayed. In addition, logging and alarm status is shown using two high intensity LEDs. LCD INDICATION Display Logger Status Explanation Delayed Start This is shown when the logger is set to start at a specific data and time* Push to Start This is shown when the logger is setup for Push to start logging Logging This is shown when the logger is running in LCD off mode, and the button is pressed. The display clears again after three seconds Stopped If the logger has not been set to log and the button is pressed, three dashes are displayed for three seconds * If the logger is set to LCD off or LCD on for 30 seconds mode, then this will only be shown after the button is pressed. Otherwise the display will remain blank. Specifications liable to change without prior warning Issue 4 07/2012 S.L Applies to EL-USB-1-LCD Page 2 of 5

LED FLASHING MODES EL-USB-1-LCD features two LEDs that indicate the logging, battery and alarm status: The first LED flashes red (R) to indicate that the EL-USB-1-LCD is in an alarm condition. It will flash when the logged temperature has exceeded a Low or High alarm level. The second LED flashes green (G) to indicate that the EL-USB-1-LCD is not in an alarm condition. Hold is enabled by default, which forces the logger to continue flashing the red LED after an alarm, even when the temperature has returned to normal. This feature ensures that the user is notified that an alarm level has been exceeded, without the need to download the data from the logger. Hold can be turned off via the control software. The red LED will then only flash whilst the logger is in an alarm condition. When the temperature returns to normal, the green LED will flash. Additional LED modes are explained below: Green single flash (10 seconds) The data logger is currently logging. No alarm. Green single flash (20 seconds) The data logger is currently logging. No alarm. However, the battery is low and should be replaced before Green single flash (30 seconds) The data logger is not currently logging, but is primed to start at a later date and time (delayed start). Green double flash (20 seconds) The data logger is full and has stopped logging. No alarm. Red single flash (10 seconds) The data logger is currently logging. Low alarm. Red single flash (20 seconds) The data logger is currently logging. Low alarm. However, the battery is low and should be replaced before Red LED Green LED Red double flash (10 seconds) The data logger is currently logging. High alarm. Red double flash (20 seconds) The data logger is currently logging. High alarm. However, the battery is low and should be replaced before Red/Green single flash (20 seconds) The data logger is full and has stopped logging. Alarm (high, low or both). No LEDs flash The data logger is stopped, the battery is empty or there is no battery fitted. Specifications liable to change without prior warning Issue 4 07/2012 S.L Applies to EL-USB-1-LCD Page 3 of 5

DIMENSIONS All dimensions in mm (inches) 25.3 (1.04) 119.5 (4.7) 22.1 (0.87) MEASUREMENT ACCURACY EL-USB-2-LCD ± 2.0 Accuracy ( C) -40-20 0 20 40 60 80 Temperature ( C) -35 0 50 80 BATTERY REPLACEMENT We recommend that you replace the battery every 12 months, or prior to logging critical data. The EL-USB-1-LCD does not lose its stored readings when the battery is discharged or when the battery is replaced; however, the data logging process will be stopped and cannot be re-started until the battery has been replaced and the logged data has been downloaded to a PC. Only use 3.6V 1/2AA lithium batteries. Check with your supplier that the battery you are ordering is press fit and is not fitted with solder tags. Before replacing the battery, remove the EL-USB-1-LCD from the PC. Note: Leaving the EL-USB-1-LCD plugged into the USB port for longer than necessary will cause some of the battery capacity to be lost. EL-USB-2+ EL-USB-2-LCD+ WARNING ± 10 ± 3.0 Handle ± lithium 8 batteries carefully, observe warnings on battery casing. ± 2.5Dispose of in accordance with local regulations. RH (%RH) ± 6 ± 4 ± 2 ± 0 0 10 20 30 40 50 60 70 80 90 100 Relative Humidity (%RH) T ( C) ± 2.0-40 -20 0 20 40 60 80 Temperature ( C) Maximal RH-accuracy at 25 C per sensor type Maximal T-accuracy per sensor type Specifications liable to change without prior warning Issue 4 07/2012 S.L Applies to EL-USB-1-LCD Page 4 of 5

THE EASYLOG USB RANGE Each EL-USB data logger features the direct-to-usb connection and easy-to-use functionality that the range is known for. The range comprises of the following data loggers: Part No Function Range Accuracy (overall error) Typ. Max. Readings Battery Battery Life* EL-USB-1 Temperature ±1ºC (±2ºF) 16,382 3.6V ½AA 1 Year EL-USB-1-LCD Temperature with LCD ±0.5ºC (±1ºF) ±1.5ºC (±3ºF) 16,382 3.6V ½AA 1 Year EL-USB-1-PRO High Temperature -40 to +125 C (-40 to +257 F) ±0.2ºC (±0.4ºF) ±0.5ºC (±1ºF) 32,510 3.6V ⅔AA 3 years EL-USB-1-RCG EL-USB-2 EL-USB-2+ EL-USB-2-LCD Temperature with rechargeable battery Temperature, humidity & dew point Increased accuracy temperature, humidity & dew point Temperature, humidity & dew point with LCD -20 to +60 C (-4 to +140 F) ±1ºC (±2ºF) 32,510 Lithium Ion ±0.5ºC (±1ºF) ±3%RH ±0.3ºC (±0.6ºF) ±2.0%RH ±0.5ºC (±1ºF) ±3.0%RH ±2ºC (±4ºF) ±6.0%RH ±1.5ºC (±3ºF) ±4.0%RH ±2ºC (±4ºF) ±6.0%RH 1 month (rechargeable) 16,382 3.6V ½AA 1 year 16,382 3.6V ½AA 1 year 16,379 3.6V ½AA 1 year Increased accuracy temperature, ±0.3ºC (±0.6ºF) ±1.5ºC (±3ºF) EL-USB-2-LCD+ humidity & dew 16,379 3.6V ½AA 1 year point with LCD ±2.0%RH ±4.0%RH EL-USB-3 Voltage 0 to 30V d.c. ±1% 32,510 3.6V ½AA 1 year EL-USB-4 Current loop 4 to 20mA ±1% 32,510 3.6V ½AA 1 year EL-USB-5 Counter, Event & State N/A ±3 secs/24 hrs 32,510 3.6V ½AA 1 year EL-USB-TC Thermocouple (J, K and T- type) K-type probe included -200 to +1350ºC (-328 to +2462ºF) (K-type) -200 to +1190ºC (-328 to +2174ºF) (J-type) -200 to +390ºC (-328 to +734ºF) (T-type) ±1ºC (±2ºF) 32,510 3.6V ½AA 6 months -200 to +1350ºC (-328 to +2462ºF) (K-type) EL-USB-TC-LCD Thermocouple with LCD (J, K and T-type) K-type probe -200 to +1190ºC (-328 to +2174ºF) (J-type) ±1ºC (±2ºF) 32,510 3.6V ½AA 6 months included -200 to +390ºC (-328 to +734ºF) (T-type) EL-USB-CO Carbon monoxide 0 to 1000ppm NOT A LIFE SAVING DEVICE ±6ppm 32,510 3.6V ½AA 3 months EL-USB-CO300 Carbon monoxide 0 to 300ppm NOT A LIFE SAVING DEVICE ±4ppm 32,510 3.6V ½AA 3 months EL-USB-LITE Low cost temperature -10 C to +50 C (+14 to +122 F) ±1ºC (±2ºF) 4,080 CR1620 Lithium coin cell 1 month EL-USB-RT Real-time temperature & humidity monitor -20 to +70 C (-4 to +158 F) *Depending on logging rate, ambient temperature, and use of alarm LED ±1.5ºC (±3ºF) ±4.5%RH 7 days N/A N/A Module House Whiteparish, Salisbury Wiltshire SP5 2SJ UK T +44 (1794) 884567 F +44 (1794) 884616 E sales@lascar.co.uk 4258 West 12th Street Erie PA 16505 USA T +1 (814) 835 0621 F +1 (814) 838 8141 E us-sales@lascarelectronics.com 8th Floor, China Aerospace Centre 143 Hoi Bun Road Kwun Tong, Kowloon HONG KONG T +852 2797 3219 F +852 2343 6187 E saleshk@lascar.com.hk Specifications liable to change without prior warning Issue 4 07/2012 S.L Applies to EL-USB-1-LCD Page 5 of 5