Using MLAG in Dell Networks



Similar documents
Virtual PortChannel Quick Configuration Guide

A Principled Technologies white paper commissioned by Dell Inc.

Link Aggregation Interoperability of the Dell PowerConnect 5316M with Cisco IOS or Cisco CatOS based Switches. By Bruce Holmes

LINK AGGREGATION INTEROPERABILITY OF THE DELL POWERCONNECT 6200 SERIES

Migrate from Cisco Catalyst 6500 Series Switches to Cisco Nexus 9000 Series Switches

Link Aggregation Interoperability of the Dell PowerConnect M6220 with Cisco IOS or Cisco CatOS Based Switches

Dell EqualLogic Best Practices Series. Dell EqualLogic PS Series Reference Architecture for Cisco Catalyst 3750X Two-Switch SAN Reference

Cisco Nexus 5548UP. Switch Configuration Guide for Dell PS Series SANs. A Dell Deployment and Configuration Guide

How To Configure Link Aggregation On Supermicro Switch 2 And 3 (Lan) On A Microsoft Vlan 2 And Vlan 3 (Vlan) (Lan 2) (Vlans) (Lummer) (Powerline) (

Chapter 4: Spanning Tree Design Guidelines for Cisco NX-OS Software and Virtual PortChannels

Configuring EtherChannels

What is VLAN Routing?

- EtherChannel - Port Aggregation

Efficient Video Distribution Networks with.multicast: IGMP Querier and PIM-DM

An Oracle White Paper October How to Connect Oracle Exadata to 10 G Networks Using Oracle s Ethernet Switches

Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance

Virtual PortChannels: Building Networks without Spanning Tree Protocol

How To Create A Web Server On A Zen Nlb (Networking) With A Web Browser On A Linux Server On An Ipad Or Ipad On A Raspberry Web 2.4 (

Abstract. MEP; Reviewed: GAK 10/17/2005. Solution & Interoperability Test Lab Application Notes 2005 Avaya Inc. All Rights Reserved.

A Dell Technical White Paper Dell Storage Engineering

Dell PowerVault MD Series Storage Arrays: IP SAN Best Practices

Chapter 2 Lab 2-2, Configuring EtherChannel Instructor Version

A Whitepaper on. Building Data Centers with Dell MXL Blade Switch

IP SAN Best Practices

A Dell Technical White Paper Dell PowerConnect Team

Dell Networking Campus Switching and Mobility Reference Architecture 2.0

HP Virtual Connect Ethernet Cookbook: Single and Multi Enclosure Domain (Stacked) Scenarios

VLAN Interoperability

Configuring LACP (802.3ad) Between a Catalyst 6500/6000 and a Catalyst 4500/4000

Design and Implementation Guide. Data Center Design Guide: Implement McAfee Next Generation Firewall for the Perimeter

Configuring IPS High Bandwidth Using EtherChannel Load Balancing

VOICE VLAN SUPPORT IN THE DELL POWERCONNECT 6200

How To Set Up A Virtual Network On Vsphere (Vsphere) On A 2Nd Generation Vmkernel (Vklan) On An Ipv5 Vklan (Vmklan)

Configuring EtherChannels

Chapter 3. Enterprise Campus Network Design

MLAG on Linux - Lessons Learned. Scott Emery, Wilson Kok Cumulus Networks Inc.

Deploying 10 Gigabit Ethernet on VMware vsphere 4.0 with Cisco Nexus 1000V and VMware vnetwork Standard and Distributed Switches - Version 1.

Dell Compellent Storage Center

16-PORT POWER OVER ETHERNET WEB SMART SWITCH

Cisco Catalyst 3750X. Rapid EqualLogic Configuration Series Implementation Guide. Dell Storage Engineering April 2014

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

Brocade Solution for EMC VSPEX Server Virtualization

Switch Quick Configuration CLI Guide for

hp ProLiant network adapter teaming

Configuring the Fabric Interconnects

Chapter 3: Cisco NX-OS Software Virtual PortChannel: Fundamental Concepts

Switching in an Enterprise Network

Configure IOS Catalyst Switches to Connect Cisco IP Phones Configuration Example

RESILIENT NETWORK DESIGN

Course. Contact us at: Information 1/8. Introducing Cisco Data Center Networking No. Days: 4. Course Code

Multi-Chassis Trunking for Resilient and High-Performance Network Architectures

6/8/2011. Document ID: Contents. Introduction. Prerequisites. Requirements. Components Used. Conventions. Introduction

Ethernet Storage Best Practices

LiveAction Application Note

Dell Wyse Datacenter for View RDS Desktops and Remote Applications

High Performance SQL Server with Storage Center 6.4 All Flash Array

STATE OF THE ART OF DATA CENTRE NETWORK TECHNOLOGIES CASE: COMPARISON BETWEEN ETHERNET FABRIC SOLUTIONS

Virtual Stacking. White Paper

Data Center Multi-Tier Model Design

VMDC 3.0 Design Overview

Abstract. Avaya Solution & Interoperability Test Lab

High Availability Failover Optimization Tuning HA Timers PAN-OS 6.0.0

High Performance Tier Implementation Guideline

Networking Solutions for Storage. Application Notes

Enhancing the Dell iscsi SAN with Dell PowerVault TM Tape Libraries and Chelsio Unified Storage Router iscsi Appliance

Juniper Networks EX Series/ Cisco Catalyst Interoperability Test Results. May 1, 2009

Configuring Switch Ports and VLAN Interfaces for the Cisco ASA 5505 Adaptive Security Appliance

Managing Web Server Certificates on idrac

Configuring the Device for Access Point Discovery

Meraki Stacking. White Paper

A Guide to Simple IP Camera Deployment Using ZyXEL Bandwidth Solutions

SIP Trunking with Microsoft Office Communication Server 2007 R2

ADVANCED NETWORK CONFIGURATION GUIDE

CHAPTER 10 LAN REDUNDANCY. Scaling Networks

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

Best Practices for Deploying SSDs in a Microsoft SQL Server 2008 OLTP Environment with Dell EqualLogic PS-Series Arrays

CCT vs. CCENT Skill Set Comparison

Design and Configuration Guide: Best Practices for Virtual Port Channels (vpc) on Cisco Nexus 7000 Series Switches

Dell PowerVault MD32xx Deployment Guide for VMware ESX4.1 Server

Cisco NetFlow Generation Appliance (NGA) 3140

Addressing Scaling Challenges in the Data Center

VMware ESX Server Q VLAN Solutions W H I T E P A P E R

Installing idrac Certificate Using RACADM Commands

Objectives. The Role of Redundancy in a Switched Network. Layer 2 Loops. Broadcast Storms. More problems with Layer 2 loops

VCE VBLOCK SYSTEMS DEPLOYMENT AND IMPLEMENTATION: NETWORK EXAM

How To Balance On A Cisco Catalyst Switch With The Etherchannel On A Fast Ipv2 (Powerline) On A Microsoft Ipv1 (Powergen) On An Ipv3 (Powergadget) On Ipv4

BLADE PVST+ Spanning Tree and Interoperability with Cisco

Configuring Cisco Nexus 5000 Switches Course DCNX5K v2.1; 5 Days, Instructor-led

Configuring Switch Ports and VLAN Interfaces for the Cisco ASA 5505 Adaptive Security Appliance

AT-S105 Version Management Software Release Notes AT-FS750/24POE and AT-FS750/48 Fast Ethernet WebSmart Switches

Load Balancing for Microsoft Office Communication Server 2007 Release 2

Intel Advanced Network Services Software Increases Network Reliability, Resilience and Bandwidth

SolarWinds Technical Reference

estpassport Bessere Qualität, bessere Dienstleistungen!

Network Virtualization and Data Center Networks Data Center Virtualization - Basics. Qin Yin Fall Semester 2013

Switching Basics and Intermediate Routing CCNA 3 Labs and Study Guide Allan Johnson

Data Center Server Access Solution Guide. NN Date: July 2010 Version: 1.1

Nutanix Hyperconverged Appliance with the Brocade VDX ToR Switch Deployment Guide

Expert Reference Series of White Papers. VMware vsphere Distributed Switches

Transcription:

dd version Using MLAG in Dell Networks A deployment guide for Dell Networking switches (version ) Dell Engineering March 04 January 04 A Dell Deployment and Configuration Guide

Revisions Date Description Author March, 04 includes limitation of partner switches, added clarification of types of ports that can be used in peer-links, and changes to topologies supported in new appendix Victor Teeter January, 04 0 Initial Release Victor Teeter PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND 04 Dell Inc All rights reserved Reproduction of this material in any manner whatsoever without the express written permission of Dell Inc is strictly forbidden For more information, contact Dell PRODUCT WARRANTIES APPLICABLE TO THE DELL PRODUCTS DESCRIBED IN THIS DOCUMENT MAY BE FOUND AT: http://wwwdellcom/learn/us/en/9/terms-of-sale-commercial-and-public-sector Performance of network reference architectures discussed in this document may vary with differing deployment conditions, network loads, and the like Third party products may be included in reference architectures for the convenience of the reader Inclusion of such third party products does not necessarily constitute Dell s recommendation of those products Please consult your Dell representative for additional information Trademarks used in this text: Dell, the Dell logo, PowerConnect, OpenManage, EqualLogic, Compellent, and Force0 are trademarks of Dell Inc Other Dell trademarks may be used in this document Cisco Nexus, Cisco MDS, Cisco NX-0S, and other Cisco Catalyst are registered trademarks of Cisco System Inc Microsoft, Windows, Windows Server, Internet Explorer, MS-DOS, Windows Vista and Active Directory are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries Broadcom and NetXtreme are registered trademarks of Broadcom Corporation Qlogic is a registered trademark of QLogic Corporation Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and/or names or their products and are the property of their respective owners Dell disclaims proprietary interest in the marks and names of others Using MLAG in Dell Networks

Table of Contents Revisions Executive Summary 4 Introduction 5 Caveats for Enabling MLAG 6 3 Supported Topologies 8 4 Single-Tier Example 9 5 Two-Tier Example 3 Appendix 9 A Unsupported Configurations 9 A Future support of MLAG with similar technologies 9 A3 Additional Resources 0 3 Using MLAG in Dell Networks

Executive Summary Multi-switch Link Aggregation or MLAG is a feature that allows two Dell Networking switches to act as a single switch, provides multiple paths across the network with benefits like: Failover in cases of failed cables or switches Increased bandwidth of up to double the bandwidth of a single switch Elimination of port blocking as well as reconvergence delays of spanning tree An MLAG domain is created by connecting a Dell Networking switch to another Dell Networking switch through Peer-Link ports to create MLAG peers (the two connected switches) Other switches directly connected to the MLAG peers are unaware that they are connecting to two switches Two switches appear as a single switch on the network All links in the MLAG can carry data traffic across many physically diverse topologies In the case of a link or switch failure, traffic continues to flow with minimal disruption MLAG optimnizes availability and bandwidth between attached devices in Dell s Datacenter and Campus networking solutions The following Dell Networking N-series switches support MLAG and may be used in building the configurations in this white paper: N04 N304 N403 N04P N304P N403F N048 N304F N4064 N048P N3048 N4064F N3048P 4 Using MLAG in Dell Networks

Introduction MLAGs provide an active-active split aggregation deployment across two switches acting as one MLAG creates a more resilient network with higher bandwidth capabilities This white paper discusses MLAGs, how and when they are used, caveats to look out for, and instructions on how to implement MLAG into your network Figure below shows two very basic examples of MLAG domains In both examples, peer switches are linked together with a special LAG (one or more cables as denoted by the red line in the pictures below), called a Peer-Link Any non-management port on the switch can be used in the Peer-Link With the Peer-Link configured, the two switches appear as a single switch to partner switches upstream and downstream Each partner switch contains MLAGs that are simply LAGs (link aggregation groups) whose cables are split between the two peers Primary and secondary peer roles are chosen automatically by the program when MLAG is enabled Simple L MLAG Primary MLAG peer MLAG domain Peer-Link Secondary MLAG peer MLAG Partner Switch MLAG domain appears as a single logical switch to partner switches on the network L3 MLAG with mulitple partner switches Primary MLAG peer MLAG domain Peer-Link Secondary MLAG peer Partner Switch MLAG MLAG Partner Switch Figure Two examples of a single-tier MLAG topology 5 Using MLAG in Dell Networks

Caveats for Enabling MLAG There are a few limitations in implementing MLAGs: Two identical switch models are required to create MLAG peers This means an N048 can only be peered with another N048, an N304 with another N304, and so on Peer devices must use the same expansion module type if ports from the expansion module are to be part of the MLAG interface Neither of the two switches used as MLAG peers may be stacked with other switches MLAG status using the show vpc brief command is only run from the primary MLAG peer when both the primary and secondary peer information is required See the switch User Guide for additional information Note: Run the show vpc brief command only from the Primary MLAG peer This provides information on both peer switches Consistency of MLAG Peers As mentioned in the section above, the two switches to be used as MLAG peers must be identical models, as well as any expansion module that is used in the MLAG peer-link setup There are also six areas in the software configuration that must be given special attention to ensure they contain identical information prior to enabling the MLAG These areas are reflected in Figure MLAG peer Link Aggregation Spanning Tree MLAG Port-channels Interfaces VLANs Firmware peer link = = = = = = MLAG peer Link Aggregation Spanning Tree MLAG Port-channels Interfaces VLANs Firmware Figure Consistent MLAG peer configurations 6 Using MLAG in Dell Networks

Change any settings mentioned below on both the MLAG peers when required Enable MLAG only after the above settings are configured on the two peer switches It is also recommended for MLAG to be temporarily disabled in order to make subsequent changes to the above settings Note: Be sure to schedule down time if making changes that impact traffic or cause data loss Note: Failure to make these areas identical may cause sporadic traffic issues on the network which are difficult to troubleshoot Option category Settings that need to match on both MLAG peers Link Aggregation Spanning Tree MLAG Port-channels Interfaces VLANs Firmware Misc Hashing mode Minimum links Static/dynamic LAG LACP parameters o Actor parameters o Admin key o Collector max-delay o Partner parameters Bpdufilter Bpduflood Auto-edge TCN-guard Cost Edgeport Root guard Loop guard STP Version STP MST VLAN configuration STP MST instance configuration (instance ID, port priority, port cost/mode) Port-channel mode Link speed Duplex mode MTU Bandwidth VLAN configuration PFC configuration CoS queue assignments MLAG VLANs must be configured on both MLAG peers, and connect to two partner LAGs Both peers require the same firmware version to operate correctly FDB entry aging timers Static MAC entries ACL configuration Table Specific configuration options to be equal among MLAG peers 7 Using MLAG in Dell Networks

Force0 S480P 5 60 QSFP+ 0 4 6 8 0 4 6 8 0 4 6 8 30 3 34 36 38 40 4 44 46 48 56 SFP+ SYS MASTER FAN PSU RS-3 ETHERNET Force0 S480P 5 60 QSFP+ 0 4 6 8 0 4 6 8 0 4 6 8 30 3 34 36 38 40 4 44 46 48 56 SFP+ SYS MASTER FAN PSU RS-3 ETHERNET 3 Supported Topologies MLAG topologies contain several options They can be a single layer (only one pair of MLAG peer switches) or two layers (two pair of MLAG peer switches) The peer-link between peers can have anywhere from to 8 active interfaces to create the link With these and other variables, there are dozens of ways to setup an MLAG Table lists all supported topology options Topological parameter Supported options # of MLAG domains per switch # of peer switches per MLAG domain # of interfaces per MLAG to 8 # of interfaces per Peer-Link to 8 # of MLAGs connecting to MLAG domain Limited only by number of ports available # of layers or Table Parameters for an MLAG topology Figure 3 shows just a few examples of MLAG topologies that can be built using the MLAG feature The red lines show the peer-lnks between the primary and secondary peer switches partner switch 3 partner switches tier ( layer, full mesh) partner switches VLTi VLTi layer (MLAG and VLT) Figure 3 Examples of MLAG topologies 8 Using MLAG in Dell Networks

4 Single-Tier Example This example shows the configuration of the two MLAG peers with two MLAG partners The default spanning tree configuration is used and spanning tree is disabled on the peer link Primary MLAG peer (47) (/0/) Peer-Link () Secondary MLAG peer N3048 (48) () N3048 (/0/) Partner Switch A (7) MLAG MLAG (9) Partner Switch B (8) (30) Figure 4 Single tier MLAG topology To configure the two MLAG peers in the basic configuration, follow the steps below: Enter the following commands on both peer switches before enabling MLAG (using the feature vpc command) on each one Each column below contains commands that can be cut and pasted into a CLI session Primary MLAG Peer (N3048) Secondary MLAG Peer N3048) Description of commands configure vlan 30 configure vlan 30 Create a VLAN for MLAG and all partner traffic interface port-channel spanning-tree disable vpc peer-link interface tengigabitethernet /0/ channel-group mode active interface port-channel 30 interface port-channel spanning-tree disable vpc peer-link interface tengigabitethernet /0/ channel-group mode active interface port-channel 30 Configure the port channel for the peer link - must be trunk mode Identify and configure the peer link interface Create a LAG for partner switch A to pass traffic 9 Using MLAG in Dell Networks

Primary MLAG Peer (N3048) Secondary MLAG Peer N3048) Description of commands vpc 30 vpc 30 Must use a native VLAN Assign a unique id for partner switch A interface port-channel 40 vpc 40 interface gigabitethernet /0/47 channel-group 30 mode active description "MLAG-Partner-link" interface gigabitethernet /0/48 channel-group 40 mode active interface range gi/0/xx-yy switchport mode access switchport access vlan 30 feature vpc vpc domain peer-keepalive enable interface port-channel 40 vpc 40 interface gigabitethernet /0/ channel-group 30 mode active interface gigabitethernet /0/ channel-group 40 mode active interface range gi/0/xx-yy switchport mode access switchport access vlan 30 feature vpc vpc domain peer-keepalive enable Create a LAG (port-channel) for partner switch B to pass traffic Assign a unique id for partner switch B Assign interfaces to connect to partner A LAG (channel-group) Assign interfaces to connect to partner B LAG (channel-group) Assign additional ports to the VLAN only for hosts that will be using the MLAG Enable the MLAG Partner Switch A Partner Switch B Description of commands configure vlan 30 configure vlan 30 create same VLAN on partners interface port-channel interface gi/0/7 channel-group mode active interface gi/0/8 channel-group mode active interface range gi/0/xx-yy switchport mode access switchport access vlan 30 interface port-channel interface gi/0/9 channel-group mode active interface gi/0/30 channel-group mode active interface range gi/0/xx-yy switchport mode access switchport access vlan 30 configure the port channel trunk for the partner link Assign interfaces to MLAG (channel-group) Assign interfaces to MLAG (channel-group) Assign additional ports to the VLAN only for hosts that will be using the MLAG 0 Using MLAG in Dell Networks

Note: Interfaces used to connect each peer to the partner switch LAG do not need to match on each peer For instance, in the example above, one partner LAG interface connects to /0/47 on the primary peer while the other interface connects to /0/ on the secondary peer Connect all cables as shown in Figure 4 3 Run the show vpc brief command on either of the two MLAG peers to see which peer is the primary MLAG peer 4 Run the show vpc brief command again from the primary switch to display all information for both peers Note: The partner switches must be configured with MLAGs and connected to the MLAG peers, or the Number of VPCs operational in the show vpc brief command shows 0 Primary MLAG Peer show vpc brief VPC admin status Enabled Keep-alive admin status Enabled VPC operational status Enabled Self role Primary Peer role Secondary Peer detection admin status Disabled Peer-Link details ------ Interface Po Peer-link admin status Enabled Peer-link STP admin status Disabled Configured VLANs,30 Egress tagged VLANs 30 VPC Details Number of VPCs configured Number of VPCs operational VPC id# 30 Interface Po30 Configured VLANs,30 VPC interface state Active Local Members Status ------ ------ Gi/0/47 Peer Members Status ----- ------ Gi/0/ VPC id# 40 Secondary MLAG Peer show vpc brief VPC admin status Enabled Keep-alive admin status Enabled VPC operational status Enabled Self role Secondary Peer role Primary Peer detection admin status Disabled Peer-Link details ------ Interface Po Peer-link admin status Enabled Peer-link STP admin status Disabled Configured VLANs,30 Egress tagged VLANs 30 VPC Details Number of VPCs configured Number of VPCs operational VPC id# 30 Interface Po30 Configured VLANs,30 VPC interface state Active Local Members Status ------ ------ Gi/0/ Peer Members Status ----- ------ < * run command from Primary for this information > VPC id# 40 Using MLAG in Dell Networks

Primary MLAG Peer Interface Po40 Configured VLANs,30 VPC interface state Active Local Members Status ------ ------ Gi/0/48 Peer Members Status ----- ------ Gi/0/ Secondary MLAG Peer Interface Po40 Configured VLANs,30 VPC interface state Active Local Members Status ------ ------ Gi/0/ Peer Members Status ----- ------ < * run command from Primary for this information > Note: Running the show vpc brief command on the primary shows the complete status of both peer switches Running the show vpc brief command on the secondary only shows the status of the secondary Results of the command should be the same as shown above All member ports must show UP, and the VPC interface state must show Active The show interface port-channel is another helpful tool to let you know if the configured LAG ports are up and running This command can be run on both the primary and secondary peers on a single layer MLAG topology If correctly configured, the port(s) in the LAG are listed with an Active status If there are any inactive ports, check for cabling or configuration issues Single-tier MLAG Peer show interface port-channel 40 Channel Ports Ch-Type Hash Type Min-links Local Prf ------- ------- -------- --------- --------- ---- Po40 Active: Gi/0/48 Dynamic 7 Disabled Hash Algorithm Type - Source MAC, VLAN, EtherType, source module and port Id - Destination MAC, VLAN, EtherType, source module and port Id 3 - Source IP and source TCP/UDP port 4 - Destination IP and destination TCP/UDP port 5 - Source/Destination MAC, VLAN, EtherType, source MODID/port 6 - Source/Destination IP and source/destination TCP/UDP port 7 - Enhanced hashing mode Using MLAG in Dell Networks

3 5 7 9 3 5 7 9 3 5 7 9 3 5 7 9 4 6 8 0 4 6 8 0 4 COMBO P 4 6 8 0 4 6 8 0 4 COMBO P Stack No SFP+ Stack No SFP+ 3 5 7 9 3 5 7 9 4 6 8 0 4 6 8 0 4 COMBO P 3 5 7 9 3 5 7 9 4 6 8 0 4 6 8 0 4 COMBO P Stack No Stack No SFP+ SFP+ 3 5 7 9 3 5 7 9 4 6 8 0 4 6 8 0 4 COMBO P 3 5 7 9 3 5 7 9 3 5 7 9 4 6 8 0 4 6 8 0 4 COMBO P 4 6 8 0 4 6 8 0 4 COMBO P 3 5 7 9 3 5 7 9 4 6 8 0 4 6 8 0 4 COMBO P 3 5 7 9 3 5 7 9 4 6 8 0 4 6 8 0 4 COMBO P 3 5 7 9 3 5 7 9 4 6 8 0 4 6 8 0 4 COMBO P 3 5 7 9 3 5 7 9 4 6 8 0 4 6 8 0 4 COMBO P 3 5 7 9 3 5 7 9 3 5 7 9 4 6 8 0 4 6 8 0 4 COMBO P Stack No SFP+ Stack No SFP+ Stack No SFP+ Stack No SFP+ Stack No SFP+ Stack No SFP+ Stack No SFP+ Stack No SFP+ 5 Two-Tier Example Figure 5 shows a logical topology for a -tier fully meshed MLAG, offering full redundancy across all four MLAG peers Six Dell N304s are used for the example, however the same principals apply and the same commands can be used on the N000 and N4000 series switches A = MLAG B Peer-Link C tier ( layer, full mesh) D Peer-Link E F Figure 5 Logical topology of a -tier full mesh configuration Figure 6 shows the physical layout of the same topology as it might appear in a rack, including cabling and attached hosts that need to communicate across the MLAG The same color scheme is used for the cables in Figure 6 that was used to show logical connections in Figure 5 (3-4) (3) Ports are denoted by the port # in parenthesis Example: gigabitethernet /0/3 is shown as (3) A B C (-) (-) (4) (3) (Te ) Server (Te ) D (-) (4) E (-) (3) (Te ) PC F (3-4) (Te ) (4) Figure 6 Physical cabling of a -tier full mesh configuration 3 Using MLAG in Dell Networks

In a full mesh, all eight ports joined together in the MLAG (four blue cables) are in the same port channel to achieve maximum redundancy To configure the -tier in a full mesh configuration, follow the steps below: Enter the commands below for each corresponding switch in the topology Cable the configuration as shown 3 Enable MLAG (using the feature vpc command) on each switch Similar commands are performed on all four MLAG peer switches MLAG peers B and C are required to be consistent in their configurations following the guidelines set in Consistency of MLAG peers MLAG peers D and E also follow the same requirements for consistency Though MLAG partner switches A and F may have similar configurations in this particular scenario, they have no such consistency requirements to each other or to the peer switches Each column below contains commands that can be cut and pasted into a CLI session if using the same topology as described in this example Command sections are color-coded to allow easier comparisons between the BC MLAG peers and the DE MLAG peers MLAG Peer B MLAG Peer C Description of commands configure vlan 30 interface port-channel spanning-tree disable vpc peer-link interface tengigabitethernet /0/ channel-group mode active interface port-channel 40 vpc 40 interface port-channel 50 vpc 50 configure vlan 30 interface port-channel spanning-tree disable vpc peer-link interface tengigabitethernet /0/ channel-group mode active interface port-channel 40 vpc 40 interface port-channel 50 vpc 50 Create a VLAN for MLAG and all partner traffic Configure the port channel for the BC peer link - must be trunk mode Identify and configure the BC peer link interfaces Create a LAG (port-channel) for partner switch DE to pass traffic Assign a unique id for partner switch DE Create a LAG (port-channel) for partner switch A to pass traffic Assign a unique id for partner switch A 4 Using MLAG in Dell Networks

MLAG Peer B MLAG Peer C Description of commands interface gigabitethernet /0/ channel-group 40 mode active interface gigabitethernet /0/ channel-group 40 mode active Assign interfaces to connect to partner E s half of full mesh LAG interface gigabitethernet /0/ channel-group 40 mode active interface gigabitethernet /0/4 channel-group 50 mode active switchport trunk allowed vlan 30 feature vpc vpc domain peer-keepalive enable interface gigabitethernet /0/ channel-group 40 mode active interface gigabitethernet /0/3 channel-group 50 mode active switchport trunk allowed vlan 30 feature vpc vpc domain peer-keepalive enable Assign interfaces to connect to partner D s half of full mesh LAG Assign interfaces to VLAN that will connect to partner A s LAG -put both 3 and 4 into same LAG 50 Enable the MLAG MLAG Peer D MLAG Peer E Description of commands configure vlan 30 interface port-channel spanning-tree disable vpc peer-link interface tengigabitethernet /0/ channel-group mode active interface port-channel 40 vpc 40 interface port-channel 60 vpc 60 interface gigabitethernet /0/ channel-group 40 mode active configure vlan 30 interface port-channel spanning-tree disable vpc peer-link interface tengigabitethernet /0/ channel-group mode active interface port-channel 40 vpc 40 interface port-channel 60 vpc 60 interface gigabitethernet /0/ channel-group 40 mode active Create a VLAN for MLAG and all partner traffic Configure the port channel for the DE peer link - must be trunk mode Identify and configure the DE peer link interfaces Create a LAG (port-channel) for partner switch BC to pass traffic Assign a unique id for partner switch BC Create a LAG (port-channel) for partner switch F to pass traffic Assign a unique id for partner switch F Assign interfaces to connect to partner B s half of full mesh 5 Using MLAG in Dell Networks

MLAG Peer D MLAG Peer E Description of commands MLAG interface gigabitethernet /0/ channel-group 40 mode active interface gigabitethernet /0/4 channel-group 60 mode active switchport trunk allowed vlan 30 feature vpc vpc domain peer-keepalive enable interface gigabitethernet /0/ channel-group 40 mode active interface gigabitethernet /0/3 channel-group 60 mode active switchport trunk allowed vlan 30 feature vpc vpc domain peer-keepalive enable Assign interfaces to connect to partner C s half of full mesh LAG Assign interfaces to VLAN that will connect to partner F s LAG -put both 3 and 4 into same LAG 60 Enable the MLAG Partner Switch A Partner Switch F Description of commands configure vlan 30 configure vlan 30 create same VLAN on partners interface port-channel interface gi/0/3 channel-group mode active interface gi/0/4 channel-group mode active interface gi/0/3 switchport mode access switchport access vlan 30 interface port-channel interface gi/0/3 channel-group mode active interface gi/0/4 channel-group mode active interface gi/0/4 switchport mode access switchport access vlan 30 configure the port channel trunks for the partner links Assign first interface to LAG (channel-group) Assign second interface to LAG (channel-group) Assign additional ports to the VLAN only for hosts that will be using the MLAG Port 3 in switch A connects to the Server, and port 4 in switch F connects to the PC client Connect all cables as shown in Figure 6 Run the show vpc brief command on either of the two MLAG peers to see which peer is the primary MLAG peer Run the show vpc brief command again from the primary switch to display all information for both peers 6 Using MLAG in Dell Networks

Note: Interfaces used to connect each peer to the partner switch LAG do not need to match on each peer For instance, in the example above, one partner LAG interface connects to /0/47 on the primary peer while the other interface connects to /0/ on the secondary peer Note: The partner switches must be configured with LAGs and connected to the MLAG peers, or the Number of VPCs operational in the show vpc brief command will show 0 MLAG Peer B (Primary Peer) show vpc brief VPC admin status Enabled Keep-alive admin status Enabled VPC operational status Enabled Self role Primary Peer role Secondary Peer detection admin status Disabled Peer-Link details ------ Interface Po Peer-link admin status Enabled Peer-link STP admin status Disabled Configured VLANs,30 Egress tagged VLANs 30 VPC Details Number of VPCs configured Number of VPCs operational VPC id# 40 Interface Po40 Configured VLANs,30 VPC interface state Active Local Members Status ------ ------ Gi/0/ Gi/0/ Peer Members Status ----- ------ Gi/0/ Gi/0/ VPC id# 50 Interface Po50 Configured VLANs,30 VPC interface state Active MLAG Peer C (Secondary Peer) show vpc brief VPC admin status Enabled Keep-alive admin status Enabled VPC operational status Enabled Self role Secondary Peer role Primary Peer detection admin status Disabled Peer-Link details ------ Interface Po Peer-link admin status Enabled Peer-link STP admin status Disabled Configured VLANs,30 Egress tagged VLANs 30 VPC Details Number of VPCs configured Number of VPCs operational VPC id# 40 Interface Po40 Configured VLANs,30 VPC interface state Active Local Members Status ------ ------ Gi/0/ Gi/0/ Peer Members Status ----- ------ < * run command from Primary for this information > VPC id# 50 Interface Po50 Configured VLANs,30 VPC interface state Active 7 Using MLAG in Dell Networks

Local Members Status ------ ------ Gi/0/4 Peer Members Status ----- ------ Gi/0/3 Local Members Status ------ ------ Gi/0/3 Peer Members Status ----- ------ < * run command from Primary for this information > Note: Running the show vpc brief command on the primary shows the complete status of both peer switches Running the show vpc brief command on the secondary shows status of the secondary only Results of the command should be the same as shown above All member ports must show UP, and the VPC interface state must show Active The show interface port-channel is another helpful tool to let you know if the configured LAGs are up and running This command must also only be run on the primary peer when used in a two-tier topology If correctly configured, ports in the primary LAG are listed with an Active status Inactive ports are usually a sign of a cabling or configuration issue MLAG Primary Peers only: B and D show interface port-channel 40 Channel Ports Ch-Type Hash Type Min-links Local Prf ------- ------- -------- --------- --------- ---- Po40 Active: Gi/0/, Gi/0/ Dynamic 7 Disabled Hash Algorithm Type - Source MAC, VLAN, EtherType, source module and port Id - Destination MAC, VLAN, EtherType, source module and port Id 3 - Source IP and source TCP/UDP port 4 - Destination IP and destination TCP/UDP port 5 - Source/Destination MAC, VLAN, EtherType, source MODID/port 6 - Source/Destination IP and source/destination TCP/UDP port 7 - Enhanced hashing mode Like the show vpc brief command, the show interfaces port-channel command must be run from the primary peer to receive information from both of the peer switches 8 Using MLAG in Dell Networks

Force0 S480P 5 60 QSFP+ 0 4 6 8 0 4 6 8 0 4 6 8 30 3 34 36 38 40 4 44 46 48 56 SFP+ Force0 S480P SYS MASTER FAN PSU RS-3 ETHERNET 5 60 QSFP+ 0 4 6 8 0 4 6 8 0 4 6 8 30 3 34 36 38 40 4 44 46 48 56 SFP+ SYS MASTER FAN PSU RS-3 ETHERNET Force0 S480P STAT ID CISCO NEXUS 3TP 0GE FABRIC EXTENDER 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 3 4 5 60 QSFP+ 0 4 6 8 0 4 6 8 0 4 6 8 30 3 34 36 38 40 4 44 46 48 56 SFP+ SYS MASTER FAN PSU RS-3 ETHERNET 5 6 7 8 9 30 3 3 3 4 5 6 7 8 Appendix A Unsupported Configurations Figure 7 shows examples of configurations that are not supported The first topology shows an MLAG peer attempting to connect with a Dell VLTi peer The second topology shows an MLAG peer attempting to connect with a Cisco vpc (or Cisco VSS) peer Neither peer configurations shown in these scenarios are supported S480 VLTi X Peer-Link N3048 Cisco vpc X Peer-Link N3048 LAG LAG Figure 7 Unsupported peer configurations A Future support of MLAG with similar technologies Figure 8 below shows MLAG peers on one layer and Dell VLT peers on the second layer, with a full-mesh LAG Results from preliminary testing of this configuration have not shown any major issues Official support for this configuration is planned for 04 LAG S480 VLTi S480 LAG N3048 Peer- Link N3048 MLAG Figure 8 Mixed LAG configuration 9 Using MLAG in Dell Networks

VLT is a feature similar to MLAG, but is available on the FTOS-based Dell Networking switches like the S480 Each peer pair must use the same multi-chassis lag feature This will provide the network with the same resiliency and improved bandwidth as when using MLAG in a multi-tier MLAG-only environment A3 Additional Resources Supportdellcom is focused on meeting your needs with proven services and support DellTechCentercom is an IT Community where you can connect with Dell Customers and Dell employees for the purpose of sharing knowledge, best practices, and information about Dell products and installations Referenced or recommended Dell publications: Dell Networking Support - http://wwwdellcom/support Dell TechCenter (community forums and blogs for Dell customers) - http://delltechcentercom Dell Networking Whitepapers - http://encommunitydellcom/techcenter/networking/w/wiki/580networkingwhitepapersaspx Dell Networking N000/N3000/N4000 User Guides and Firmware downloads - http://wwwdellcom/support/mysupport/us/en/04#04/products/ser_stor_net/networking?&_suid=38478460040069403 9436666 A4 Configuration details This paper was compiled using the following components and versions Component Description Dell Networking firmware versions D99, 600, 6004 Switch Dell Networking N000, N3000, and N4000 series 0 Using MLAG in Dell Networks

About Dell Dell is a worldwide leader in data center and campus solutions which includes the manufacturing and distribution of servers, network switches, storage devices, personal computers, and related hardware and software For more information on these and other products, please visit the Dell website at http://wwwdellcom Using MLAG in Dell Networks