Hemoglobin detection kit Catalog # ADI-907-034



Similar documents
Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma

Human Free Testosterone(F-TESTO) ELISA Kit

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

> IGF-1 (human) Table of Contents. Catalog # Well Enzyme Immunoassay Kit For use with human serum and plasma

Mouse glycated hemoglobin A1c(GHbA1c) ELISA Kit

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

Bovine Vitamin B12 (VB12) ELISA Kit

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

Mouse krebs von den lungen 6 (KL-6) ELISA

Canine Creatine Kinase MM isoenzyme(ck-mm) ELISA. kit

Human Luteinizing Hormone (LH) Custom Kit

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #:

ab Protein Sumoylation Assay Ultra Kit

Phosphate Assay Kit (Colorimetric)

Immunoglobulin E (IgE) concentrations in Human. Immunoglobulin E (IgE) Human ELISA Kit

Malondialdehyde (MDA) ELISA

Human IP-10 ELISA Kit, pink-one

Mouse glycated hemoglobin A1c (GHbA1c) ELISA Kit

Rat Creatine Kinase MB Isoenzyme (CKMB) ELISA

ab Albumin Human ELISA Kit

Testosterone high sensitivity ELISA kit

TOTAL PROTEIN FIBRINOGEN

IgE (Human) ELISA Kit

Uscn Life Science Inc. Wuhan

Testosterone EIA Kit User Manual

Reagents Quantity Reagents Quantity. Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4. Standard 2 Standard Diluent 1 20mL

ab Complement C1q Human ELISA Kit

For the rapid, sensitive and accurate measurement of ATP in various samples.

TECHNICAL BULLETIN. Angiotensin II EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0010 Storage Temperature 20 C

RayBio Human IL-8 ELISA Kit

TRIIODOTHYRONINE (T3) ELISA Kit Protocol

IP10 Human ELISA Kit

TECHNICAL BULLETIN. Glucagon EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0202 Storage Temperature 20 C

Creatine Kinase Activity Assay Kit (Colorimetric)

Intact PTH. system. Intact PTH /R5. Key to symbols used 8K25

Rat Fibronectin ELISA Kit

MULTI-ARRAY. 1-Plate Kit 5-Plate Kit 20-Plate Kit

Glycolysis Cell-Based Assay Kit

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

Creatine Kinase Microplate Assay Kit User Manual

ab83369 Alkaline Phosphatase Assay kit (Colorimetric)

INSTRUCTION Probemaker

OxiSelect Advanced Glycation End Product (AGE) Competitive ELISA Kit

Toxoplasma gondii IgM ELISA Kit Protocol

Mouse GLP-2 ELISA. For quantitative determination of mouse GLP-2 in serum or plasma samples.

For the development of sandwich ELISAs to measure phosphorylated Epidermal Growth Factor Receptor (EGF R) in cell lysates.

QuickZyme Soluble Collagen Assay

Escherichia coli Host Cell Proteins (E. coli HCP) Kit

Hydrogen Peroxide Cell-Based Assay Kit

UltraClean Soil DNA Isolation Kit

HBV Quantitative Real Time PCR Kit

Laboratory Procedure Manual

Testosterone (Pig) ELISA Kit

QuickTiter FeLV Core Antigen ELISA Kit (FeLV p27)

The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of PST in mouse tissue homogenates and other biological fluids.

Lab 2 Biochemistry. Learning Objectives. Introduction. Lipid Structure and Role in Food. The lab has the following learning objectives.

Creatine Kinase Activity Colorimetric Assay Kit ABE assays; Store at -20 C

Catalase Assay Kit. Catalog Number CAT100 Storage Temperature 2 8 C TECHNICAL BULLETIN

MTT Cell Proliferation Assay

RayBio Human TNF-alpha

IP-10 ELISA KIT INTENDED USE

Creating Standard Curves with Genomic DNA or Plasmid DNA Templates for Use in Quantitative PCR

LAB 14 ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA)

TECHNICAL BULLETIN. Cholecystokinin (CCK) EIA Kit for serum, plasma, culture supernatant, and cell lysates

Human Testosterone EIA Kit

Cell Cycle Phase Determination Kit

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

TECHNICAL BULLETIN. Brain Natriuretic Peptide EIA Kit for serum, plasma, culture supernatant, and cell lysates

Chem 405 Biochemistry Lab I Experiment 2 Quantitation of an unknown protein solution.

RayBio Creatine Kinase (CK) Activity Colorimetric Assay Kit

Cancer Antigen CA125 Human ELISA Kit

Data Sheet. PD-L1:B7-1[Biotinylated] Inhibitor Screening Assay Kit Catalog # Size: 96 reactions

QuickTiter Hepatitis B Surface Antigen (HBsAg) ELISA Kit

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

P i Per Pyrophosphate Assay Kit

Catalase Assay Kit. Item No Customer Service Technical Support

Catalase. ***You will be working with hot water, acids and bases in this laboratory*** ****Use Extreme Caution!!!****

How Does a Doctor Test for AIDS?

Enzymes: Amylase Activity in Starch-degrading Soil Isolates

PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

ProteoMiner Protein Enrichment Kits

ELISA-VIDITEST-MICROCYSTIN LR Lot: XX

Free Testosterone Cat# 2924Z

Epinephrine/Norepinephrine ELISA Kit

UNIT: Total and Direct Bilirubin

Human Parathyroid Hormone (PTH) ELISA Kit

Lipid Extraction Kit (Chloroform Free), Trial Size

Lipid Extraction Kit (Chloroform Free)

PRODUCT INFORMATION...

Malachite Green Phosphate Assay Kit

Rat Anti-KLH Rat IgM ELISA Kit

Annexin V-FITC Apoptosis Detection Kit

The fastest spin-column based procedure for purifying up to 10 mg of ultra-pure endotoxin-free transfection-grade plasmid DNA.

Qualification Study CHO 360-HCP ELISA (Type A to D)

Transcription:

New Dual Range! Hemoglobin detection kit Catalog # ADI-907-034 2x96 wells For use with blood samples Store at 4 C. Check our website for additional protocols, technical notes and FAQs. For proper performance, use the insert provided with each individual kit received. Table of Contents 2 Introduction 2 Principle 3 Materials Supplied 3 Storage 3 Materials Needed but Not Supplied 4 Sample Handling 5 Reagent Preparation 6 Assay Procedure 6 Calculation of Results 7 Typical Results 8 Performance Characteristics 10 References 11 Plate Layout 12 Limited Warranty Patent Pending FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES. 1 07-07-10

Introduction The Hemoglobin Detection kit uses a single reaction solution that is stable at room temperature, not light sensitive and does not contain dangerous chemicals. All forms of hemoglobin are rapidly converted to a single stable form that is measured photometrically. Many samples can be measured without dilution in this safe, simple assay. Hemoglobin (Hgb) is an erythrocyte protein complex comprised of two sets of identical pairs of subunits, each of which bind an iron-prophyrin group commonly called heme. Generally containing two alpha or alphalike globulin chains, the remaining subunits may be beta, gamma, delta or epsilon, or in the case of infants, fetal hemoglobin that is replaced during the first year of life. Heme binds and releases oxygen or carbon dioxide in response to slight changes in local gas tension. 1 Free oxygen or carbon dioxide bound by one heme group facilitates subsequent binding by the other heme groups in a given hemoglobin molecule. 2 Subtle changes in ph also regulate hemoglobin affinity for free gases, resulting in a high level of hemostatic control. Hemoglobin values are associated with a variety of conditions ranging from anemias (low Hgb), erythrocytosis (high Hgb), thalassemias (aberrant chain synthesis), and sickling disorders (abnormal complex shape). 1 The universal reference procedure for hemoglobin determination in blood has been the cyanmethemoblobin method as determined by the Clinical and Laboratory Standards Institute TM and the International Council for Standardization in Haematology 3-5. In this method, ferricyanide and potassium cyanide convert hemoglobin to a more stable cyanmethemoglobin form that is measured photometrically. While this method is straightforward and uses a single reaction solution, not all forms of hemoglobin are converted to cyanmethemoglobin at the same rate or even to completion. In addition to the safety issues surrounding cyanide, the reagent itself is not stable, so extra care needs to be taken to ensure the quality of any measurement. Principle 1. Samples and standards are added to the wells of a microtiter plate. 2. Hemoglobin Detection Reagent is added to each well. 3. The plate is incubated at room temperature. 4. Optical density is measured at 570 nm. 2 07-07-10

Materials Supplied Do not mix components from different kit lots or use reagents beyond the kit s expiration date. The standard should be handled with care due to the known and unknown effects of the antigen. The physical, chemical, and toxicological properties of the reagents in this kit may not have been fully investi-gated. Therefore, we recommend the use of gloves, lab coats, and eye protection while using any of these reagents. 1. Microtiter Plate Two plates of 96 wells, Catalog No. 80-2268 The plate is ready to use. 2. Hemoglobin Sample Diluent 50 ml, Catalog No. 80-2270 Sample Diluent containing detergent and 0.09% sodium azide. 3. Hemoglobin Standard 300 µl, Catalog No. 80-2269 A stock solution of human hemoglobin at 16 g/dl. CAUTION: From human origin; potentially infectious. 4. Hemoglobin Detection Reagent 20 ml, Catalog No. 80-2271 Special formulation of reagents to detect hemoglobin. CAUTION: Caustic. Storage The kit should be stored at 4 C. All kit components are stable at their recommended storage temperatures until the kit expiration date. Recommended storage temperatures do not necessarily reflect shipping conditions. Materials Needed but Not Supplied 1. Deionized or distilled water. 2. Precision pipets for volumes between 5 μl and 1,000 μl. 3. Disposable beakers for diluting buffer concentrates. 4. Graduated cylinders. 5. Disposable glass tubes. 6. Microplate reader capable of measuring optical density between 560-580 nm. 7. Software for converting optical density readings from the plate reader and carrying out four parameter logistic curve (4PL) fitting. 3 07-07-10

Sample Handling This assay has been validated for whole blood, hemolyzed serum, EDTA plasma, and heparin plasma samples from multiple species. Samples containing visible particulate should be centrifuged prior to using. Any samples with hemoglobin concentrations above the standard curve range should be diluted further with Hemoglobin Sample Diluent to obtain readings within the standard curve. Use all samples within 2 hours of preparation. Regular Assay Format Whole blood must be diluted 1:2 with Hemoglobin Sample Diluent prior to running in the kit. Red blood cells should be lysed with the supplied sample diluent prior to use in this kit. Hemolyzed serum may be used without dilution. High Sensitivity Assay Format Serum and plasma samples may be run without any dilution. Sample Values Five human whole blood and four human erythrocyte lysates were tested in the assay. Whole blood values ranged from 21.36 to 13.95 g/dl with an average of 15.77 g/dl and erythrocyte lysates ranged from 21.58 to 40.21 g/dl with and average of 32.23 g/dl, not corrected for hemocrits. Normal reference range for human whole blood is 12.0 17.0 g/dl. 6 4 07-07-10

Reagent Preparation Bring all reagents to room temperature for at least 30 minutes prior to opening. Standard Preparation - Regular Format Label six glass test tubes as #2 through #7. Briefly vortex and spin the vial of standard in a microcentrifuge to ensure contents are at bottom of vial. The Hemoglobin Standard supplied in the kit is standard 1. Pipet 50 μl of Hemoglobin Sample Diluent into tubes #2 to #7. Carefully add 50 μl of the Hemoglobin Standard in the Standard vial provided to tube #2 and vortex completely. Take 50 μl of the Hemoglobin solution in tube #2 and add it to tube #3 and vortex completely. Repeat the serial dilutions for tubes #4 through #7. The concentration of Hemoglobin in the Hemoglobin Standard vial and tubes #2 through #7 will be 16, 8, 4, 2, 1, 0.5 and 0.25 g/dl. Standard Preparation - High Sensitivity Format Label six glass test tubes as #1 through #7. Briefly vortex and spin the vial of standard in a microcentrifuge to ensure contents are at bottom of vial. Pipet 525 μl of Hemoglobin Sample Diluent into tube #1, and 250 μl into tubes #2 to #7. Carefully add 75 μl of the Hemoglobin Standard provided to tube #1 and vortex completely. Take 250 μl of the Hemoglobin solution in tube #1 and add it to tube #2 and vortex completely. Repeat the serial dilutions for tubes #3 through #7. The concentration of Hemoglobin in tubes #1 through #7 will be 20, 10, 5, 2.5, 1.25, 0.625 and 0.313 mg/ml. Use all prepared standards within 2 hours of preparation. 5 07-07-10

Bring all reagents to room temperature for at least 30 minutes prior to opening. Assay Procedure Refer to the plate layout at the end of this document to determine the number of wells to be used. Cover unused wells tightly with a plate sealer. DO NOT REUSE WELLS! Regular Format 1. Pipet 10 μl of Sample Diluent into the zero standard wells. 2. Pipet 10 μl of standards or samples into the duplicate wells in the plate. 3. Pipet 100 μl of Hemoglobin Detection Reagent into each well. Gently tap the plate to mix. 4. Incubate for 30 minutes at room temperature. 5. Read fluorescence at 560-590 nm. High Sensitivity Format 1. Pipet 100 μl of Sample Diluent into the zero standard wells. 2. Pipet 100 μl of standards or samples into the duplicate wells in the plate. 3. Pipet 100 μl of Hemoglobin Detection Reagent into each well. Gently tap the plate to mix. 4. Incubate for 30 minutes at room temperature. 5. Read fluorescence at 560-590 nm. Calculation of Results Average the duplicate OD readings for each standard and sample. Subtract the mean OD of the zero standard wells from each standard and sample to get the net OD. Create a standard curve by reducing the net OD using 4PL curve fitting software, such as the Assay Blaster! assay analysis software (Cat. #ADI-28-0002). 6 07-07-10

Typical Results This data is for illustration purposes only and should not be used to calculate the results of your experiment. Typical data - Regular Format Sample Net OD Hemoglobin Conc. (g/dl) Zero 0 0 Standard 1 1.993 16 Standard 2 0.870 8 Standard 3 0.426 4 Standard 4 0.199 2 Standard 5 0.113 1 Standard 6 0.057 0.5 Standard 7 0.028 0.25 Sample 1 0.844 7.64 Sample 2 0.133 1.35 2.0 1.5 1.0 0.5 0.0 0 2 4 6 8 10 12 14 16 Hemoglobin Conc. (g/dl) 7 07-07-10

Typical data - High Sensitivity Format Sample Net OD Hemoglobin Conc. (mg/ml) Zero 0 0 Standard 1 1.978 20 Standard 2 1.019 10 Standard 3 0.508 5 Standard 4 0.264 2.5 Standard 5 0.131 1.25 Standard 6 0.068 0.625 Standard 7 0.032 0.313 Sample 1 1.074 10.56 Sample 2 0.083 0.079 8 07-07-10

Performance Characteristics Sensitivity Sensitivity was calculated by comparing the OD s for twenty wells run for each of the zero and standard #7. The detection limit was determined at two (2) standard deviations from the zero along the standard curve Sensitivity was determined as 0.0214 g/dl for the Regular Format and 0.0033 g/dl for the High Sensitivity Format. Limit of Detection The Limit of Detection for the assay was determined in a similar manner by comparing the OD s for twenty replicates for each of the zero standard and a low concentration diluted human sample. Limit of Detection was determined as 0.021 g/dl for the Regular format and 0.0033 g/dl for the High Sensitivity format. Linearity Serum linearity was determined by taking a human EDTA plasma sample with a low Hgb level of 0.46 g/dl diluted 1:2 with water and a sheep serum spiked with RBCs with a high level of 9.45 g/dl diluted 1:2 with water and mixing them in the ratios given below. The measured concentrations were compared to the expected values based on the ratios used. Low Sam- High Sam- Expected Conc Observed Conc % Recov- ple ple (g/dl) (g/dl) ery 100% 0% 0.46 --- --- 80% 20% 2.26 2.26 100.3 60% 40% 4.05 4.14 102.0 40% 60% 5.85 5.62 96.0 20% 80% 7.65 7.49 97.9 0% 100% 9.45 --- --- Mean Recovery 99.1% 9 07-07-10

Intra Assay Precision Three mammalian samples were diluted with Hemoglobin Sample Diluent and run in replicates of 20 in an assay. The mean and precision of the calculated hemoglobin concentrations were: Sample Hemoglobin Conc. (g/dl) %CV 1 7.63 1.7 2 4.73 3.1 3 1.34 2.2 Inter Assay Precision Three mammalian samples were diluted with Hemoglobin Sample Diluent and run in duplicates in ten assays run over multiple days by three operators. The mean and precision of the calculated hemoglobin concentrations were: Sample Hemoglobin Conc. (g/dl) %CV 1 7.48 2.9 2 4.69 3.6 3 1.34 7.9 Interference Data A whole blood sample was serially diluted with 40 g/dl BSA to test for protein interference and tested in the assay. No significant change in the measured hemoglobin level was observed over five two-fold dilutions. To test for glucose interference a whole blood sample was serially diluted with 2 g/dl glucose and tested in the assay. No significant change in the measured hemoglobin level was observed over five twofold dilutions. For lipid interference a whole blood sample was serially diluted with a mixture containing 0.8 g/dl cholesterol and 11.2 g/dl triglycerides and tested in the assay. No significant change in the measured hemoglobin level was observed over five two-fold dilutions. A whole blood sample was serially diluted with 2 mg/dl of bilirubin and tested in the assay. A 0.7% change in the measured hemoglobin level was observed. Bilirubin at 2 mg/dl in normal adults would be considered jaundiced. Newborns can have bilirubin levels above 5 mg/dl. 10 07-07-10

Assay Comparison 15 RBC lysate samples were tested in this kit and in a competitors kit. The correlation result is shown below. 12 10 8 6 y = 1.0249x - 0.5655 4 R 2 = 0.9928 2 0 0 2 4 6 8 10 12 Other Hemoglobin Assay (g/dl) 11 07-07-10

References 1. Tietz, NW, Textbook of Clinical Chemistry, WB Saunders Company, Philadelphia. 2. Manning, JM et al., Normal and abnormal protein subunit interactions, 1998, J Biol Chem. 273(13):19359-62. 3. Drabkin, DL and JH Austin, Spectrophotometric Studies: II. Preparations from washed blood cells; nitric oxide hemoglobin and sulfhemoglobin, 1935, J Biol Chem, 112(1):51-65. 4. Bull, BS, et al., Reference and selected procedures for the quantitative determination of hemoglobin in blood; approved standard third edition, NCCLS Vol. 20 No. 28. NCCLS document H15-A3. 5. Rowan, RM, Recommendations for reference method for haemoglobinometry in human blood (ICSH standard 1995) and specifications for international haemiglobincyanide standard (4 th edition), 1996, J Clin Pathol, 49:271-74. 6. Hemoglobin test; Results. MayoClinic.com. 13 July 2009 http://www.mayoclinic.com/health/hemoglobintest/my00529/dsection=results 12 07-07-10

Plate Layout 13 07-07-10

Notes 14 07-07-10

Notes 15 07-07-10

Use of Product This product contains research chemicals. As such, they should be used and handled only by or under the supervision of technically qualified individuals. This product is not intended for diagnostic or human use. Warranty Enzo Life Sciences International, Inc. makes no warranty of any kind, expressed or implied, which extends beyond the description of the product in this brochure, except that the material will meet our specifications at the time of delivery. Enzo Life Sciences International, Inc. makes no guarantee of results and assumes no liability for injuries, damages or penalties resulting from product use, since the conditions of handling and use are beyond our control. www.enzolifesciences.com Enabling Discovery in Life Science www.enzolifesciences.com North/South America Germany UK & Ireland ENZO LIFE SCIENCES INT L, INC. ENZO LIFE SCIENCES GmbH ENZO LIFE SCIENCES (UK) LTD. 5120 Butler Pike Marie-Curie-Strasse 8 Palatine House Plymouth Meeting, PA 19462-1202/USA DE-79539 Lorrach / Germany Matford Court Tel. 1-800-942-0430/(610)941-0430 Tel. +49/0 7621 5500 526 Exeter EX2 8NL / UK Fax (610) 941-9252 Toll Free 0800 664 9518 Tel. 0845 601 1488 (UK customers) info-usa@enzolifesciences.com Fax +49/0 7621 5500 527 Tel. +44/0 1392 825900 (overseas) info-de@enzolifesciences.com Fax +44/0 1392 825910 info-uk@enzolifesciences.com Switzerland & Rest of Europe Benelux France ENZO LIFE SCIENCES AG ENZO LIFE SCIENCES BVBA ENZO LIFE SCIENCES Industriestrasse 17, Postfach Melkerijweg 3 c/o Covalab s.a.s. CH-4415 Lausen / Switzerland BE-2240 Zandhoven / Belgium 13, Avenue Albert Einstein Tel. +41/0 61 926 89 89 Tel. +32/0 3 466 04 20 FR-69100 Villeurbanne / France Fax +41/0 61 926 89 79 Fax +32/0 3 466 04 29 Tel. +33 472 440 655 Inf-ch@enzolifesciences.com info-be@enzolifesciences.com Fax +33 437 484 239 Info-fr@enzolifesciences.com 16 07-07-10