General Home Inspection

Similar documents
Real Estate Inspection Report

Home Inspection Report

Home Inspection Report

Home Inspection Report

Home Inspection Report

Home Inspection Report

Home Inspection Report

Strickland Home Inspections, LLC th Ct N Plymouth, MN Inspection Report. xxxx St Clair Ave St Paul, MN 55105

Vari Inspection Services

Peak Home Inspection Services

Home Inspection Report

A.C.E. Home Inspection Service St. Peters, MO (636)

Inspection Tech. (330) Inspected By: Aaron Westerburg

Table of Contents. Definitions General Information Lots and Grounds Exterior Surface and Components Garage/Carport Electrical

Inspecton Report. Property Address:

Aztec Property Inspections 2719 Mission Blvd San Diego, CA (858) Some Road San Diego, CA 92114

PROPERTY INSPECTION REPORT

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES

Georgia Home Inspection Services

Building Condition Assessment Report

Clouse Inspection Services 5512 Harvard Road Lawrence, Kansas Easy Street Anytown, USA

Crawford Inspection Services C.C.B. #

Home Inspection SW 19th Avenue;Rd Ocala, Fl Prepared for: Pauline Humper Prepared by: Amerispec Home Inspection Service

Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado

SWF Home Inspections

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS

Printed Monday, August 27, 2007 Inspected By: Michelle Teague. Client Information: Inspection, Condo City Lane Chicago, IL. Inspected 8/22/07 8:00 AM

Accurate Home Inspection of Illinois. Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave., Westmont, Illinois

G.Warren, Inc. Home Inspection

Vision Home Inspection

Propery Inspection Report

Home Inspection Report

October 5, 2015 Dear Client,

Inspection Report Atlanta Strip Mall Commercial Building Property Address:

Inspection Report. provided by: Delaware Property Inspection. Inspector: Richard Hiddemen (302)

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

South Carolina Home Inspector Standards of Practice

Terry Jenkins, Owner Member, American Society of Home Inspectors Virginia Certified Home Inspector Certificate # , expires 1/2010

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space)

Total Home Inspection Checklist

COMPREHENSIVE PROPERTY INSPECTIONS

A-Pro Building Inspections

INVOICE. DATE: May 11, DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl.

Orlando Home Inspection Services

PROPERTY INSPECTION REPORT Property Address:

SNS Home Inspections LLC

Pre-Drywall Inspection Report

Does Wall Township require an inspection by the building department on resale of a home?

HOME INSPECTION CHECKLIST

159 Morningside Avenue, Toronto

Inspection Report. Prepared For: Sampath Sample. Property Address: Waterside Drive. Alpharetta, GA Atlanta Home Inspections

Self-Home Inspection Checklist

Home Inspection Report

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME

Recommend that the dryer vent be cleaned annually to remove lint that may cause a fire.

HOME INSPECTION REPORT

The Uniform Building Inspection Report Condensed

Inspection Report. Prepared For: Atlanta Commercial Customer. Property Address: xxx Sandy Plains Road. Building 5 Marietta, GA 30066

A and S Property Inspector

A comfortable house is a great source of happiness. - Sydney Smith. Home Maintenance Guide

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE:

If there are any further questions with regards to the report or inspection, please call.

Estimating Database Checklist

Home Systems Data Inc E. Peakview Ave. Centennial CO

GARR HOME INSPECTIONS, LLC

Summit Series Single Section and Double Section Homes

Home. Safe. Home. home inspection report

GeorgiaHomePros.com Yellow Creek Road Ball Ground, GA Inspected By: Scott Webb

I NI NP R Inspected Items

Home Inspection Report

SNS Home Inspections LLC

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

Property Inspection Report

Inspection Report. Jacksonville Krystals Inspection. Property Address: Downtown. Jacksonville FL South East Building Consultants

ROCK-SOLID Inspections

Inspection Report. Joe Smith. Property Address: 2222 SW 20 St Miramar FL Coast to Coast Property Inspections

OC Home Inspect. 333 S Crest Rd Orange, CA (714) guybrianadams@gmail.com Inspected By: Brian Adams

Inspection Report 95 Old Stage Road East Brunswick NJ Scott Frederick

BUILDING ANALYSIS REPORT. John Doe 1234 Smith Road Atlanta, Georgia 30396

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

Burns Home Services SUMMARY REPORT. 7/18/2006 Start: 9:00 am End: 12:30 pm

Inspection Report. Dream Home Inspections Second Ave. Frisco CO (970)

November 18, Customer Name Customer Address. Inspection Address Seattle, WA Inspection #: Dear Customer:

Building Condition Assessment Report

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check

BUILDING INSPECTION REPORT

ink Home Inspections, LLC

RUSS L. ROBINSON ATLANTA COMMUNITIES (770)

VIRGINIA HOME INSPECTIONS P.O.BOX 586 CHINCOTEAGUE ISLAND, VA PHONE

API America s Property Inspections

The BrickKicker is pleased to present this professional home inspection report for the property located at: 123 Main St. Happy Town, IL 65432

Code Enforcement Inspection Manual. City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division

South Carolina Home Inspector Standards of Practice

Inspection Report. Prepared for: William Smith 2700 New Street Plano, TX 75025

License Requirements for Persons Engaging in the Business of Inspection Practice:

Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10

Latigos Trail 911 Latigos Trail ~ Des Peres, Missouri $428,500

2. What building projects are exempted? (permit not required)

Transcription:

General Home Inspection Your New City, Ohio 12345 Prepared for: John and Jane Homebuyer Prepared by: General Home Inspection

Page 1 of 18 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior 3 Garage/Carport 5 Air Conditioning 5 Roof 6 Electrical 6 Basement 7 Plumbing 8 Heating System 8 Laundry Room/Area 9 Structure 9 Fireplace/Wood Stove 10 Bathroom 10 Kitchen 12 Bedroom 13 Living Space 14 Summary 15

Page 2 of 18 Definitions NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection Functional with no obvious signs of defect. Needs Maintenance Item needs maintenance Needs Repair Item is not fully functional and requires repair or servicing. Defective Item needs immediate repair or replacement. It is unable to perform its intended function. Not Inspected Item was unable to be inspected for safety reasons or due to lack of power, inaccessible, or disconnected at time of inspection. Property Address City Your New City State Ohio Zip 12345 Contact Name John and Jane Homebuyer Phone 216-555-1234 Client Name John and Jane Homebuyer Client Address 456 New House Rd. City New City State Ohio Zip 45678 Phone 216-555-1234 Inspector Name Jay Brzezinski Company Name General Home Inspection Company WebSite www.generalhomeinspection.com E-Mail jay@generalhomeinspection.com Company Phone 216-554-7272 File Number 123AnyStreet Amount Received $275.00 General Information Property Information Client Information Inspection Company Conditions Others Present Buyer's Agent and Buyer Property Occupied Occupied Inspection Date 09-15-2013 Start Time 9:00 am End Time 12:00 pm Electric On Yes Gas/Oil On Yes Water On Yes Temperature 60 Weather Partly sunny Soil Conditions Dry Space Below Grade Basement Building Type Single family Garage Attached Sewage Disposal City How Verified Visual Inspection Water Source City How Verified Visual Inspection Additions/Modifications Finished basement

Page 3 of 18 Lots and Grounds Driveway: Concrete Needs Maintenance Walks: Concrete - Crack in concrete, recommend filling to avoid further damage Needs Repair Steps/Stoops: Concrete Porch: Concrete Patio: Concrete - Crack in concrete, recommend filling to avoid further damage, Heavily cracked and unevenly settled causing trip hazard Deck: Treated wood Grading: Moderate slope, Minor slope Swale: Adequate slope and depth for drainage Vegetation: Shrubs, Trees Northwest Exterior Surface Type: Vinyl siding Trim: Aluminum Fascia: Aluminum Soffits: Aluminum Door Bell: Hard wired Entry Doors: Metal Patio Door: Vinyl sliding Exterior

Page 4 of 18 Needs Repair Exterior (Continued) Windows: Wood double hung - Rotted wood on exterior window sash Needs Repair Window Screens: Vinyl mesh Basement Windows: Wood casement Exterior Lighting: Surface mount Exterior Electric Outlets: 110 VAC - Non-GFCI outlet, Exposed wiring present, Inoperative at time of inspection, Recommend installing a GFCI outlet in all exterior outlets Needs Repair Hose Bibs: Gate - Signs of past or present leakage, A licensed plumber is recommended to evaluate and estimate repairs Gas Meter: Exterior surface mount at side of home Main Gas Valve: Located at gas meter

Page 5 of 18 Garage/Carport Attached Garage Type of Structure: Attached Car Spaces: 2 Garage Doors: Insulated aluminum Door Operation: Mechanized Door Opener: Genie Exterior Surface: Vinyl siding Roof: Asphalt shingle Roof Structure: 2x4 Truss Ceiling: Texture paint Walls: Drywall Floor/Foundation: Poured concrete Hose Bibs: Rotary Needs Repair Electrical: 110 VAC - Protect exposed surface mounted wiring running along garage ceiling, Missing outlet/switch cover plates Smoke Detector: None Heating: None Windows: None Gutters: Aluminum Downspouts: Aluminum Air Conditioning Main AC System A/C System Operation: Functional Condensate Removal: PVC Exterior Unit: Pad mounted Manufacturer: Carrier Model Number: CA362013R Serial Number: 2013CA4759 Area Served: Whole building Approximate Age: New Fuel Type: 220 VAC Temperature Differential: Type: Central A/C Capacity: 3 Ton Visible Coil: Copper core with aluminum fins Refrigerant Lines: Suction line and liquid line Electrical Disconnect: Blade disconnect Exposed Ductwork: Metal Blower Fan/Filters: Direct drive with disposable filter

Page 6 of 18 Air Conditioning (Continued) Thermostats: Programmable Main Roof Surface Method of Inspection: Ladder at eaves Material: Asphalt shingle Type: Gable Approximate Age: New Flashing: Aluminum Plumbing Vents: PVC Electrical Mast: Surface mount Gutters: Aluminum Downspouts: Aluminum East Chimney Chimney: Brick Flue/Flue Cap: Clay, Metal Chimney Flashing: Aluminum Roof Electrical Service Size Amps: 100 Volts: 110-240 VAC Service: Aluminum 120 VAC Branch Circuits: Copper 240 VAC Branch Circuits: Copper Conductor Type: Romex, Non-metallic sheathed cable Needs Repair Ground: No ground present in panel - Grounds should be located from panel to ground rod outside of home and to the water main, where they should be affixed to the home side and service side, from the street. Smoke Detectors: Battery operated Basement Electric Panel Manufacturer: General Electric Maximum Capacity: 100 Amps Main Breaker Size: 100 Amps Needs Repair Breakers: Copper - Double taps are present at breakers. These circuits need to be moved to their own circuit breaker and cannot share a breaker. It is recommended that a qualified electrician inspect the new circuits and properly connect the new circuits to an individual breaker for each circuit

Page 7 of 18 Electrical (Continued) GFCI: Kitchen and bathrooms Is the panel bonded? Yes Needs Repair Sub Panel: Sub panel has open "knock-out" hole- insert "blank-out" cap to close off opening Main Basement Needs Repair Basement Ceiling: Texture paint, Exposed framing Walls: Paint Floor: Carpet Floor Drain: Surface drain Doors: Hollow wood Windows: Wood casement - Hard operation, Will not open Electrical: 110 VAC - Outlets should not be located above baseboard electric heaters. Remove outlet, terminate wires and install blank cover plate. Install cover plates on open work boxes. Smoke Detector: Battery operated HVAC Source: Heating system register Insulation: Fiberglass Ventilation: Windows Basement Stairs/Railings: Wood stairs with wood handrails

Page 8 of 18 Plumbing The inspection of furnaces/boilers/heat pumps/air conditioners is limited to a visual inspection and basic operation to verify operating condition. Service Line: Copper Main Water Shutoff: Basement Water Lines: Copper Drain Pipes: PVC Service Caps: Accessible Vent Pipes: PVC Gas Service Lines: Cast iron Basement Water Heater Water Heater Operation: Adequate Manufacturer: Craftmaster Model Number: EE2H40RD045V Serial Number: 0304161475 Type: Electric Capacity: 40 Gal. Approximate Age: 2008 Area Served: Whole building Flue Pipe: Single wall Needs Repair TPRV and Drain Tube: Copper - TPRV Drain tube opening should be located within six inches of the floor, Drain tube opening is not within six inches of the floor Heating System The inspection of furnaces/boilers/heat pumps/air conditioners is limited to a visual inspection and basic operation to verify operating condition. Main Heating System Heating System Operation: Adequate Manufacturer: Bryant Model Number: 912SB48060S17 Serial Number: 1514A50299 Type: Forced air Capacity: 60,000 BTUHR Area Served: Whole building Approximate Age: New Electrical: 110 VAC Fuel Type: Natural gas Heat Exchanger: 3 Burner Blower Fan/Filter: Direct drive with disposable filter Distribution: Metal duct Flue Pipe: PVC

Page 9 of 18 Humidifier: April-Aire Thermostats: Programmable Suspected Asbestos: No Heating System (Continued) Laundry Room/Area 1st Floor Laundry Room/Area Closet: None Ceiling: Texture paint Walls: Paint Floor: Ceramic tile Doors: Bi-fold Windows: None Electrical: 110 VAC, 220 VAC Smoke Detector: None HVAC Source: None Laundry Tub Drain: PVC Washer: None Washer Hose Bib: Rotary Washer and Dryer Electrical: 110-240 VAC Dryer: None Needs Repair Dryer Vent: Metal flex - Possible loose connection of dryer vent flex line, evidenced by duct tape Dryer Gas Line: Cast iron Washer Drain: Wall mounted drain Structure Structure Type: Wood frame Foundation: Block Beams: Steel I-Beam Bearing Walls: Block Joists/Trusses: 2x8 Piers/Posts: Steel posts Floor/Slab: Poured slab Stairs/Handrails: Wood stairs with wood handrails Subfloor: Plywood

Page 10 of 18 Fireplace/Wood Stove Living Room Fireplace Needs Maintenance Freestanding Stove: Wood burning - Recommend cleaning and inspection by a certified chimney professional, prior to use Fireplace Construction: Brick Type: Wood burning Smoke Chamber: Brick Flue: Tile Damper: Metal Hearth: Raised Master Bathroom Defective Bathroom Closet: None Ceiling: Texture paint Walls: Paint Floor: Ceramic tile Doors: Hollow wood Windows: Wood double hung Electrical: 110 VAC GFCI - Faulty GFCI outlet-replace Counter/Cabinet: Granite, Wood Sink/Basin: Porcelain Faucets/Traps: Delta fixtures with a PVC trap Shower/Surround: Fiberglass pan and fiberglass surround

Page 11 of 18 Needs Repair Bathroom (Continued) Toilets: 1 1/2 Gallon Tank - Toilet does not flush properly, Missing caps exposed flange bolts Needs Repair HVAC Source: Heating system register - Register cover not installed properly to opening Ventilation: Electric ventilation fan and window 2nd floor main Bathroom Closet: None Ceiling: Texture paint Walls: Paint Floor: Ceramic tile Doors: Hollow wood Windows: None Needs Repair Electrical: 110 VAC GFCI - Missing outlet/switch cover plates Counter/Cabinet: Granite, Wood Sink/Basin: Porcelain Faucets/Traps: Delta fixtures with a PVC trap Tub/Surround: Fiberglass tub and ceramic tile surround Toilets: 1 1/2 Gallon Tank HVAC Source: Heating system register Ventilation: Electric ventilation fan

Page 12 of 18 Kitchen Note: Kitchen appliances that are installed or otherwise noted are tested for basic operation, ie. a dishwasher will be run on a normal or short cycle etc. This is not a comprehensive test of every function. 1st Floor Kitchen Needs Repair Cooking Appliances: Whirlpool, Westinghouse Ventilator: Non-vented /non-ducted, re circulating exhaust fan Disposal: In-Sinkerator Dishwasher: Frigidaire Microwave: General Electric Sink: Stainless Steel Electrical: 110 VAC GFCI Plumbing/Fixtures: Chrome - The faucet is loose. Counter Tops: Granite Cabinets: Wood Pantry: Small & Walk-in Needs Maintenance Ceiling: Texture paint - Evidence of past or present water staining. Area is right below master bathroom shower. Recommend a qualified contractor or plumber to evaluate possible leaking. Walls: Paint Floor: Ceramic tile Doors: Hollow wood Windows: Wood casement HVAC Source: Heating system register

Page 13 of 18 Bedroom 2nd Floor Master Bedroom Closet: Small & Walk-in Ceiling: Texture paint Walls: Paint Floor: Carpet Doors: Hollow wood Needs Repair Windows: Wood double hung - Repair faulty operating hardware Rear Bedroom Needs Repair Electrical: 110 VAC HVAC Source: Heating system register Smoke Detector: Battery operated Closet: Small Ceiling: Texture paint Walls: Paint Floor: Carpet Doors: Hollow wood Windows: Wood double hung Electrical: 110 VAC - Open grounds noted at 3 prong outlets, Grounded receptacles should be replaced with non-grounded receptacles, where non grounded wiring is present. Front Bedroom HVAC Source: Heating system register Smoke Detector: Battery operated Closet: Small Ceiling: Texture paint Walls: Paint Floor: Carpet Doors: Hollow wood Windows: Wood double hung

Page 14 of 18 Bedroom (Continued) Electrical: 110 VAC HVAC Source: Heating system register Smoke Detector: Battery operated Living Space The testing of smoke and Carbon Monoxide (CO) detectors is outside the scope of the general home inspection. The US Fire administration and FEMA recommend the replacement of smoke and carbon monoxide detectors at minimum every 8-10 years. Follow detector manufacturer recommendations regarding replacement schedule which may call or more frequent replacement. If detector age is unknown, it is recommended that new detectors be installed following manufacturer guidelines. For additional information please visit: http://www.usfa.fema.gov/citizens/home_fire_prev/alarm Note: The general home inspection can not verify with certainty if materials are hazardous. Further testing by a qualified/licensed contractor/lab(s) may be necessary. 1. Lead Paint If you are purchasing a home that was built prior to 1978, paint used in the home may contain lead. Lead is considered a health hazard. For additional information regarding lead paint visit www.epa.gov/lead/. Family Room Living Space Closet: None Ceiling: Texture paint Walls: Paint Floor: Carpet Doors: Hollow wood Windows: Wood double hung Electrical: 110 VAC HVAC Source: Heating system register Smoke Detector: Battery operated

Page 15 of 18 Needs Maintenance Summary Lots and Grounds 1. Walks: Concrete - Crack in concrete, recommend filling to avoid further damage Fireplace/Wood Stove 2. Living Room Fireplace Freestanding Stove: Wood burning - Recommend cleaning and inspection by a certified chimney professional, prior to use Kitchen 3. 1st Floor Kitchen Ceiling: Texture paint - Evidence of past or present water staining. Area is right below master bathroom shower. Recommend a qualified contractor or plumber to evaluate possible leaking.

Page 16 of 18 Needs Repair Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. Lots and Grounds 1. Patio: Concrete - Crack in concrete, recommend filling to avoid further damage, Heavily cracked and unevenly settled causing trip hazard Exterior 2. Windows: Wood double hung - Rotted wood on exterior window sash 3. Exterior Electric Outlets: 110 VAC - Non-GFCI outlet, Exposed wiring present, Inoperative at time of inspection, Recommend installing a GFCI outlet in all exterior outlets 4. Hose Bibs: Gate - Signs of past or present leakage, A licensed plumber is recommended to evaluate and estimate repairs Garage/Carport 5. Attached Garage Electrical: 110 VAC - Protect exposed surface mounted wiring running along garage ceiling, Missing outlet/switch cover plates Electrical 6. Ground: No ground present in panel - Grounds should be located from panel to ground rod outside of home and to the water main, where they should be affixed to the home side and service side, from the street. 7. Basement Electric Panel Breakers: Copper - Double taps are present at breakers. These circuits need to be moved to their own circuit breaker and cannot share a breaker. It is recommended that a qualified electrician inspect the new circuits and properly connect the new circuits to an individual breaker for each circuit 8. Basement Electric Panel Sub Panel: Sub panel has open "knock-out" hole- insert "blank-out" cap to close off opening Basement 9. Main Basement Electrical: 110 VAC - Outlets should not be located above baseboard electric heaters. Remove outlet, terminate wires and install blank cover plate. Install cover plates on open work boxes. Plumbing 10. Basement Water Heater TPRV and Drain Tube: Copper - TPRV Drain tube opening should be located within six inches of the floor, Drain tube opening is not within six inches of the floor Laundry Room/Area 11. 1st Floor Laundry Room/Area Dryer Vent: Metal flex - Possible loose connection of dryer vent flex line, evidenced by duct tape Bathroom 12. Master Bathroom Toilets: 1 1/2 Gallon Tank - Toilet does not flush properly, Missing caps exposed flange bolts 13. Master Bathroom HVAC Source: Heating system register - Register cover not installed properly to opening 14. 2nd floor main Bathroom Electrical: 110 VAC GFCI - Missing outlet/switch cover plates

Page 17 of 18 Needs Repair Summary (Continued) Kitchen 15. 1st Floor Kitchen Plumbing/Fixtures: Chrome - The faucet is loose. Bedroom 16. 2nd Floor Master Bedroom Windows: Wood double hung - Repair faulty operating hardware 17. Rear Bedroom Electrical: 110 VAC - Open grounds noted at 3 prong outlets, Grounded receptacles should be replaced with non-grounded receptacles, where non grounded wiring is present.

Page 18 of 18 Defective Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. Bathroom 1. Master Bathroom Electrical: 110 VAC GFCI - Faulty GFCI outlet-replace