The Implant System The Implant System was developed in Germany by Dr. xel Kirsch in the early 1970 s. is the only major implant system using a shock absorbing intermobile element designed to simulate the periodontal ligament. Two types of implants were made the Original nonhex and the Hex Head external hex (ranemark RP compatible). Original & non-hex Hex Head & external hex - Original - Hex Head Original The original implant was manufactured in two diameters mm and mm. The internal thread of the mm implant is 2.3mm and the mm implant has a 3.0mm internal thread. The external implant body is either titanium plasma sprayed or H coated with hydroxalappetite. The implant body is no longer sold, however, restorative components, such as the IME, IMC, and UM are still available from ttachments International. Hex Head - ranemark RP Compatible The Hex Head implant also manufactured in two diameters mm and mm was added in 1991. oth are restoratively compatible with the ranemark Regular Platform implant. For restorative compatible components refer to the ranemark section of this manual. Compatible components made by ttachments International are available for: Implants Original & non-hex Restoratively Compatible To none Hex Head & external hex ranemark, Regular Platform 4.1 Refer to ranemark RP Section for 3i Minimplant & Standard Osseotite compatible Hex Head Implamed RP components Innova Entegra 3.25 & REmark-ST RP Steri-Oss Hex-Loc 3.8 & 4.5 Restore RD & Sustain RD Taper-Lock ømm 2.3mm Thread Diameter ømm 3.0mm Thread Diameter ø4.1mm Platform 2.0mm Thread Diameter 2.7mm 3.4mm External Hex 2.7mm 2.3mm Thread 3.0mm Thread 2.0mm Thread Original Original Hex Head Non-Hex Non-Hex ranemark RP Implant Diameter Implant Diameter Compatible Implant Diameters & ll product names referenced herein are trademarks of their Copyright 2007 ttachments International, Inc., San Mateo, C 249
Terminology of Components & Page Header Sample Guide Direct To The Implant Healing Caps Implant nalog Components listed on page Compatible Implant Name Direct To The Implant Indirect Components - Original Restoration Connection Restorative Components: For ease in selecting components, the ranemark Section is divided by Restoration Connection: Direct To The Implant or Indirect To n Intermediate Component (Tissue Extensions/butments). Overdenture ttachments, ar Systems, Indirect Individual Parts and Tools are found following in the Indirect Section. NEW: 7 REFERENCE CHRTS are found at end of this section to illustrate the complex relationship of the - IME - IMC components. The Direct Restorative Components are the elements used to fabricate a restoration that will be connected directly to the implant(s). The Indirect / Intermediate Restorative Components fit to an intermediate tissue extension (abutment) which in turn is connected to the implant(s). Implant ody: The implant body is surgically placed into the bone. One surgical method traditionally involved a two-stage surgery, leaving the implant unloaded in the bone to allow for osseointegration, followed by tissue surgery to uncover the implant before the restorative components are added. nother method, called Immediate Loading, is a one-stage surgery where the abutment and restoration are attached to the implant at the time of implant placement. IME & TIE UM Intermediate Connector / Tissue Extension / IME / TIE: The TE (Tissue Extension) is the intermediate connector between the implant and the restoration, it may extend above the tissue. In some instances, a TE extension is subgingival, to provide a more esthetic restoration. The original tissue extension was the plastic IME (Inter Mobile Element) with the metal TIE. Implant Standardization: The UM tissue extension was developed to standardize the components and instruments for many different implant allowing for an economical inventory and for simplicity of restorative procedures. Its tapered/hexagon fitting surface is identical, regardless of the size or type of implant employed, while its screw-in base is implant specific. Compatibility: Implants Original & non-hex Restoratively Compatible To none Hex Head & external hex ranemark, Regular Platform 4.1 Refer to NOELranemark RP Section 3i Minimplant & Standard Osseotite for compatible Hex Head Implamed RP components Innova Entegra 3.25 & REmark-ST RP Steri-Oss Hex-Loc 3.8 & 4.5 Taper-Lock ll product names referenced herein are trademarks of their respective companies. Copyright 2006 ttachments International, Inc., San Mateo, C 248
Non-Hex & Direct To The Implant Healing Caps Impression Copings nalogs HELING CPS Healing caps are used to maintain access through tissue during healing phase. They are available in various heights to accommodate tissue depth and require the.050" hex driver. Small Implant Diameter Medium Implant Diameter Description Dimensions Order # Order # Healing Caps To Fit Implant Implant Healing Cap H=2.0mm 56-302120 56-402120 Implant Healing Cap H=mm 56-302140 56-402140 Implant Healing Cap H=6.0mm 56-302160 56-402160 TOOLS DDS Hex Driver.050" 11-000007 11-000007 IMPRESSION COPINGS Impression copings are used to take an impression of the implant body. The Impression Copings which fit the implant bodies are made of titanium and transfer the thread timing. For the -Hex Head implant, refer to the ranemark RP compatible section. Small Implant Diameter Medium Implant Diameter Description Order # Order # Impression Copings To Fit Implant Impression Coping for 56-300080 56-400080 NLOGS nalogs are used for the fabrication of a master model. They are replicas of the implant body. Description Order # Order # nalogs To Fit Implant Implant ody nalog to fit, rass 56-300015 56-400015 ll product names referenced herein are trademarks of their Copyright 2007 ttachments International, Inc., San Mateo, C 251 dditional Information: www.attachments.com
Non-Hex & Direct To The Implant Titanium Posts Ti-locs TITNIUM POSTS The direct titanium abutment posts screw into the implant body and are indicated for ridge Restorations only. They may be secured with Teflon tape or thread adhesive. The titanium tapered posts can be altered like a preparation. Fabricate a soft tissue model whenever preparations are made in the laboratory. Small Implant Diameter Medium Implant Diameter Description Order # Order # Direct Titanium Posts () 56-301200 56-401200 USE WITH: Impression Coping 56-300080 56-400080 Implant ody nalog 56-300015 56-400015 REQUIRES.050" HEX DRIVER: DDS.050" Hex Driver 11-000007 Lab.050" Driver 11-000006 IO-TORQ Tip Hex.050", Short (Use with io-torq Wrench) 59-100120 IO-TORQ Tip Hex.050", Long (Use with io-torq Wrench) 59-100125 TI-LOC The titanium bloc screws into the non-hexed implant body and may be secured with Teflon tape or thread adhesive. The Ti-loc requires more preparation as it is a true cylindrical bloc. However, the Ti-loc can be prepared like a posterior prep, thereby increasing the esthetics and comfort. It can also be prepared to correct for divergency. Insertion requires.050" hex driver..050" hex.050" hex Description Dimensions Order # Order # Ti-loc small () ø=4.7mm 56-301210 Ti-loc small () ø=5.0mm 56-401210 USE WITH: Impression Coping 56-300080 56-400080 Implant ody nalog 56-300015 56-400015 REQUIRES.050" HEX DRIVER: DDS.050" Hex Driver 11-000007 Lab.050" Driver 11-000006 IO-TORQ Tip Hex.050", Short (Use with io-torq Wrench) 59-100120 IO-TORQ Tip Hex.050", Long (Use with io-torq Wrench) 59-100125 ll product names referenced herein are trademarks of their Copyright 2010 ttachments International, Inc., urlingame, C 256 dditional Information: www.attachments.com
Non-Hex & Indirect IME butments Titanium Plastic IME with TIE IME COMPONENTS Titanium Plastic Modified IME IME UTMENT IME butments (tissue extensions) are intermediate components made to fit between the implant and the restoration. The IME, in plastic or Titanium, requires the Titanium TIE. The Modified IME, in plastic or Titanium, fits directly to the implant. Restorations can be made on the abutment using abutment cylinders. The UM Healing Cap protects the IME until restoration is delivered. The Impression Coping takes an impression of the abutment and transfers abutment position and thread timing. The nalog is a replica of the abutment and is used for fabrication of a master model. The CSP (Cylinder, Screw & Plug) is used for crown & bridge and bar restorations. SEE REFERENCE CHRTS #1 & #2 (at end of section) Reference UM Indirect page for Healing Caps to fit IME. Tapered C 2 Pc C 2 Pc C D E E Impression Coping Imp Coping 2pc Imp Coping 2pc nalog CSP mm CSP mm Description Dimensions Intended Use Order # Order # C D E IME (Intramobile Element) Tissue Extension Height Tissue Extension / butment IME, Plastic (requires TIE) 2.0mm 57-8270U 57-8280U IME, Plastic (requires TIE) mm N/ 57-8285U IME, Titanium (requires TIE) 2.0mm 57-8273TU 57-8283TU IME, Titanium (requires TIE) mm N/ 57-8288TU TIE (Transmucosal Implant Extension) Collar Extension TIE, Titanium (not for Mod. IME) 1.0mm 57-8258 TIE, Titanium (not for Mod. IME) 2.0mm 57-8250 57-8260 TIE, Titanium (not for Mod. IME) mm 57-8255 Modified IME (Modified Intramobile Element) Tissue Extension / butment IME, Plastic (direct to implant) 57-8270MU 57-8280MU IME, Titanium (direct to implant) 57-8273MU 57-8283MU Components To Fit IME and Modified IME/ Tissue Extension Impression Coping Impression Taking / Transfer Timing Tapered Impression coping, transfer thread timing (closed tray) 56-000080 56-000080 Impression coping, 2 piece, transfer thread timing (open tray) 56-300095 56-400095 nalog Model Fabrication IME / nalog, rass (Replicates both IME & Modified IME) 56-000015 56-000015 CSP (Cylinder, Screw & Plug) Crown & ridge / ar Restorations IME CSP, Non-Engaging Cylinder,.050" Hex Screw and Plug 56-300252 56-400252 PRTS Plastic Cylinder Only, Long for or (also fits the IMC & ) 56-000250 56-000250 Plastic Cylinder Only, Short for or (also fits the IMC & ) 56-000270 56-000270 Ti Hex.050" Screw Only (To fit IME and Complete butment) 56-300052 56-400052 TOOLS Reamer, UM butment Carbide.0880" (requires Pin Vise 40-000150) 11-000150 11-000150 Pin Vise for Carbide Reamers.002 -.130" 40-000150 40-000150 UM, Lapping Tool and Guide Pin Reamer 11-000155 11-000155 Friction Grip Driver (for plastic IME) Pin Vise 11-000004 11-000004 IO-TORQ Tip, UM, Short (for Titanium IME only) 59-100150 59-100150 IO-TORQ Wrench 30 N/cm 59-100030 59-100030 ll product names referenced herein are trademarks of their Copyright 2007 ttachments International, Inc., San Mateo, C 253
Non-Hex & Indirect IMC butment Titanium IMC Connector IMC UTMENTS (Intramobile Connector) The original IMC (Intramobile Connector) consists of a titanium insert and a plastic element (donut). The Ti IMC is a onepiece titanium abutment that replaces the original titanium insert and plastic element. The IMC two-piece impression coping connects to the original plastic IMC or the Ti IMC. The Plastic IMC Element C IMC analog is used to fabricate a working model. Castablemachined plastic cylinders are used in the fabrication of the screw-retained framework. SEE REFERENCE CHRTS #1 - #4 (end of section) IMC Titanium Insert Ti IMC Connector IMC COMPONENTS Note: Thread is only in lower portion of both the IMC Connector and the IMC nalog, requiring the longer IMC screw. Original IMC Ti Insert & IMC Plastic Element Fits: IME & IMC & Fits: IME & IMC & D Impression Coping E nalog Thread in lower portion F Description Dimensions Intended Use Order # Order # Long F Short C D E F IMC Titanium Connector IMC Ht Overall Ht Tissue Extension / butment Ti IMC, Titanium 1.0mm 1.8mm 57-8310CU Ti IMC, Titanium 2.0mm 2.8mm 57-8317CU 57-8311CU Ti IMC, Titanium Conversion 3.5mm 57-8318CU Ti IMC, Titanium 3.0mm 3.8mm 57-8319CU 57-8312CU Ti IMC, Titanium mm 4.8mm 57-8320CU 57-8313CU IMC Titanium Insert Insert & Element IMC Ti Insert (requires IMC Element) 1.0mm 1.8mm 57-8162C IMC Ti Insert (requires IMC Element) 2.0mm 2.8mm 57-8170C 57-8163C IMC Ti Insert (requires IMC Element) Conversion 3.5mm 57-8175C IMC Ti Insert (requires IMC Element) 3.0mm 3.8mm 57-8171C 57-8164C IMC Ti Insert (requires IMC Element) mm 4.8mm 57-8165C IMC Plastic Element Insert with butment IMC, Intramobile Element, Plastic ushing ("donut") 57-8104C 57-8104C Components To Fit IMC Connector and IMC Insert Impression Coping, 2 Piece Impression Taking / Transfer Timing IMC 2 Piece Impression coping, transfers thread timing 57-300090 57-400090 nalog Model Fabrication IMC nalog, rass 57-300016 57-400016 PRTS Plastic Cylinder Only, Non-Engaging, Long for or (also fits the IME & ) 56-000250 56-000250 Plastic Cylinder Only, Non-Engaging, Short for or (also fits the IME & ) 56-000270 56-000270 NOTE: Screws indicated depend on initial restoration. See Flow Charts #5 & #6 for complete list of available screws. Contact Technical Support for further information, 650-340-1426. TOOLS Reamer, UM butment Carbide.0880" (requires Pin Vise 40-000150) 11-000150 11-000150 Pin Vise for Carbide Reamers.002 -.130" 40-000150 40-000150 UM, Lapping Tool and Guide Pin 11-000155 11-000155 IO-TORQ Tip / IMC, Short 59-100171 59-100172 IO-TORQ Wrench 30 N/cm 59-100030 59-100030 ll product names referenced herein are trademarks of their Copyright 2007 ttachments International, Inc., San Mateo, C 254
Non-Hex & Compatible Indirect UM butment UM COMPONENTS UM UTMENT The UM butment (tissue extension) is an intermediate component made to fit between the implant and the restoration. The UM has a standardized fitting surface, which allows the UM restorative components to be interchangeable regardless of the implant type. The UM Healing Cap protects the UM until the restoration is delivered. The ridge Tapered UM Impression Coping transfers the UM position while the Hex UM Impression Coping transfers the hex orientation of the UM butment. The UM nalog replicates the UM for the model. The UM Hex or Non-Hex Plastic Cylinders are used to make frameworks for bridges or bars. The UM CL System is used for a passive fit technique. For restorations the fit directly to the implant refer to the UCL System for the specific implant type. C C D E E Healing Cap Impression Coping Impression Coping nalog CSP CSP CL Cylinder Tapered 1 piece Hex 2 piece rass Hex Cyl, Hex screw Non-Hex Cyl, Hex Screw Description Dimensions Intended Use Order # Order # C D E F UM butment Tissue Extension Height Tissue Extension / butment UM, butment H=0.5mm N/ 11-001405 UM, butment H=1.0mm N/ 11-001410 UM, butment H=2.0mm 11-001320 11-001420 UM, butment H=3.0mm 11-001330 11-001430 UM, butment H=mm 11-001340 11-001440 UM, butment H=5.0mm 11-001350 11-001450 UM, butment H=6.0mm 11-001360 11-001460 UM, butment H=7.0mm 11-001370 11-001470 Components To Fit UM butment / Tissue Extension Healing Cap Tissue Healing / Management One Thread Size Fits ll UMs UM Healing Cap H=2.0mm ø=4.5mm 11-002120 UM Healing Cap H=mm ø=4.5mm 11-002140 UM Healing Cap H=6.0mm ø=4.5mm 11-002160 Impression Coping Impression Taking / Transfer Timing UM Impression Coping Tapered, one piece 11-000080 UM Impression Coping Hex with.050" Hex Guide Pin, two piece 11-000090 nalog Model Fabrication UM nalog, rass 11-000015 CSP (Cylinder, Screw & Plug) Crown & ridge / ar Restorations UM Hex Cylinder (blue), Ti.050" Hex Screw & Occlusal Plug 11-000202 UM Hex Cylinder (blue), Ti Slot Screw & Occlusal Plug 11-000201 UM Non-Hex Cylinder (yellow), Ti.050" Hex Screw & Occlusal Plug 11-000252 UM Non-Hex Cylinder (yellow), Ti Slot Screw & Occlusal Plug 11-000251 CL Cylinder (Passive Fit) ars / Fixed Detachable UM CL Cylinder, Ti.050" Hex Screw, Waxing Sleeve & Spacer 11-000452 NOTE: Slot Screws (#11-000051) may be ordered separately. PRTS UM.050" Hex Titanium Screw, only 11-000052 UM, Short ar Cylinder only, Red 11-000270 FOR INDIVIDUL UM PRTS & TOOLS Refer to the UM Section of this Manual. ll product names referenced herein are trademarks of their respective companies. Copyright 2006 ttachments International, Inc., San Mateo, C 253 dditional Information: www.attachments.com
Non-Hex & Overdenture ttachments OVERDENTURE STUD TYPE TTCHMENTS Three types of overdenture attachments are most commonly used to directly screw into the implant the Dalla ona, the ORS, (O-Ring system) and the Locator. Connectors are made of titanium. Dalla ona male, ORS male and Locator female are sold separately by tissue height. The D Female Kit includes 1 adjustable female, 1 spacer and 1 brass analog. The ORS Female Kit includes 1 gold plated retainer ring, 3 white final & 3 red processing O-Rings and 1 brass analog. The Locator Male Complete includes 3 plastic color coded males, a metal housing with black processing male and spacer. D D ORS ORS Locator Locator or C C D D llegro Implant Female Kit Optional for D Small Implant Diameter Medium Implant Diameter Description Dimensions Order # Order # Dalla ona System () Dalla ona, male only H=1mm 56-343013 56-443013 Dalla ona, male only H=2mm 56-343023 56-443023 Dalla ona, male only H=3mm 56-343033 56-443033 Dalla ona, male only H=4mm 56-343043 56-443043 H Dalla ona, male only H=5mm 56-343053 56-443053 Dalla ona, male only H=6mm 56-343063 56-443063 Dalla ona, male only H=7mm 56-343073 56-443073 Dalla ona, Implant Ti Female: Fe, Spacer & nalog Fø=3.4mm 40-430002 40-430002 llegro, Implant Female Kit (option for Dalla ona female) () 40-730002 40-730002 includes Metal Housing, 4 Females, Implant Spacer & rass nalog ORS, O-Ring System (C) ORS, male only H=1mm 56-344013 56-444013 ORS, male only H=2mm 56-344023 56-444023 ORS, male only H=3mm 56-344033 56-444033 ORS, male only H=4mm H 56-344043 56-444043 ORS, male only H=5mm 56-344053 56-444053 ORS, male only H=6mm 56-344063 56-444063 ORS, male only H=7mm 56-344073 56-444073 ORS, Implant Female Kit, includes Retainer Ring, nalog & O-Rings (6) 40-440002 40-440002 Locator System (D) Locator Implant Female only H=0mm 63-008820 63-008830 Locator Implant Female only H=1mm 63-008820-1 63-008830-1 Locator Implant Female only H=2mm H 63-008820-2 63-008830-2 Locator Implant Female only H=3mm 63-008820-3 63-008830-3 Locator Implant Female only H=4mm 63-008820-4 63-008830-4 Locator Implant Female only H=5mm 63-008820-5 63-008830-5 Locator Male Complete 63-008519 63-008519 Locator Extended Range Male Complete 63-008540 63-008540 Locator Extended Range Replacement Male, 3 lbs retention, green (4) 63-008547 63-008547 Locator Extended Range Replacement Male, 2 lbs retention, orange (4) 63-008915 63-008915 Locator Extended Range Replacement Male, 1.5 lbs retention, red (4) 63-008548 63-008548 PRTS & TOOLS For Dalla ona, llegro, ORS & Locator Parts and Tools, refer to next page. For Hex Head & External Hex compatible components, refer to the ranemark RP / Direct section of this manual. ll product names referenced herein are trademarks of their Copyright 2007 ttachments International, Inc., San Mateo, C 256
Non-Hex & Compatible Dalla ona, ORS, Locator Parts & Tools for Overdenture Stud Type ttachments OVERDENTURE STUD TYPE TTCHMENTS PRTS & TOOLS PRTS: Description Dimensions Order # DLL ON FOR IMPLNTS Dalla ona, Implant Female Kit: includes Female, Spacer & rass nalog 40-430002 Dalla ona, Resilient Female, Gold FH=3.1mm 97-430282 Dalla ona, Resilient Female, Titanium FH=3.4mm 99-451012 Dalla ona, Resilient Female, Plastic (4) FH=3.5mm 99-430282 Dalla ona Hex nalog, rass (2) 40-430017 Dalla ona Hex Spacer, rass (2) 40-430016 PVC Ring (6), replacement ring for Dalla ona female 97-430200 ORS FOR IMPLNTS ORS, Retainer Rings (6) H=2.0mm ø=5.1mm 99-440044 ORS, Combo O-Rings: 6 blue, 6 red (processing), 6 wt, 6 blk Outside ø=4.5mm Inside ø=1.4mm 99-443037 ORS, Implant Female Kit: includes Retainer Ring, rass nalog and 3 red processing & 3 white final O-Rings 40-440002 O-Ring Hex nalog, rass (2) 40-440017 LOCTOR FOR IMPLNTS Locator Male Complete 63-008519 Includes 1 metal housing with a black nylon processing male, spacer, 3 final nylon males: 1 clear 5lbs, 1 pink 3lbs & 1 blue 1.5lbs retention Locator Male Extended Range Complete 63-008540 Includes 1 metal housing with a black nylon processing male, spacer, green nylon ex range male 3 lbs retention, orange nylon ex range male 2 lbs retention and red ex range male 1.5 lbs retention Locator Replacement Males Inserts, retention 5 lbs, clear (4) 63-008524 Locator Replacement Males Inserts, retention 3 lbs, pink (4) 63-008527 Locator Replacement Males Inserts, retention 1.5 lbs, blue (4) 63-008529 Locator Extended Range Replacement Male, 3 lbs retention, green (4) 63-008547 Locator Extended Range Replacement Male, 2 lbs retention, orange (4) 63-008915 Locator Extended Range Replacement Male, 1.5 lbs retention, red (4) 63-008548 Locator Impression Male 63-008505 Locator Female nalog Standard 4mm 63-008530 Locator Female nalog Wide Platform 5-6mm 63-008516 Male Removal Tool In Position Locator Core Insertion/ Removal Tool Out Position Male Seating Tool Interior.050" hex for insertion ll product names referenced herein are trademarks of their Copyright 2007 ttachments International, Inc., San Mateo, C Female Triangular Seating Tool Replacement Males Male Retention Sequence Least to Most: lue - Pink - Clear 5 lbs. 3 lbs. 1.5 lbs. Dalla ona ctivating Tool Dalla ona Deactivating Tool 257 dditional Information: www.attachments.com Extended Range Males Extended Male Retention Sequence Least to Most: Red - Orange - Green TOOLS IO-TORQ Wrenches, Socket & Driver IO-TORQ Wrench 10 N/cm 59-100010 IO-TORQ Wrench 20 N/cm 59-100020 IO-TORQ Wrench 30 N/cm 59-100030 IO-TORQ Wrench 35 N/cm 59-100035 IO-TORQ Socket 59-100190 IO-TORQ Extension 59-100195 IO-TORQ ORS / Dalla ona Tip/Driver 59-100140 IO-TORQ Locator Tip/Driver 59-100146 short 59-100147 long LT/R DRIVER LT/R R Hand Driver 58-100000 LT/R R Handle / Socket 58-100190 LT/ R ORS / Dalla ona Tip 58-100140 LT/R Locator Tip/Driver 58-100146 short 58-100147 long Dalla ona ctivating Tool, lue 99-451017 Dalla ona Deactivating Tool, Yellow 99-451018 Locator Core Insertion/ Removal Tool 63-008393 Locator Male Removal Tool only 63-008397 Locator Parallel Posts (4) 63-008517 LLEGRO (for replacement parts see llegro OD section page 99) llegro OD/DE Micro/Regular Insertion Tool 73-410162 3 lbs. 2 lbs. 1.5 lbs.
Non-Hex & Compatible Overdenture ar Restorations IDEL R RESTORTIONS There are numerous options for implant bar restorations available today. To simplify your search, we have selected the most proven and popular systems on this page. For a complete listing of all bar system components, refer to the ar and Clip Quick Reference Charts. Most implant bar restorations involve from 2 to 5 implants. The ideal implant bar system incorporates a bar and retentive clips in the anterior section and locking pin attachments distally for support and stability. The Hader-EDS ar Master kit is the preferred choice. The CM Gold Clips may be used as an alternative. The locking SwissLoc NG ttachment is the preferred distal attachment to prevent lift-off and still provide resiliency. The Lew ttachment is a viable alternative. For Laser Welding Technique, use only titanium bars and posts. Recommended parts needed for a successful bar restoration: PPM ar 0 degree SwissLoc ttachments Hader-EDS Clips Hader-EDS ar Description Order # HDER-EDS R MSTER KIT 99-531005 Master Kit includes 6 yellow plastic clips, 6 metal housings, 2 seating tools and 2 short plastic bars (50mm) TOOLS: Hader-EDS ar nalog 50mm, aluminum (1) 99-531015 Hader-EDS Fabricating Rider / Clip (6) Green 99-531020 Hader-EDS Impression Clip (6) lue 99-531080 CM HDER-EDS R KIT 99-532000 CM Kit includes 6 CM gold riders (clips) with spacers and 2 short plastic Hader-EDS bars (50mm) TOOLS: CM djusting Tool (can be used with all metal riders / sleeves) 97-510125 CM ar nalog 50mm (aka Hader-EDS ar nalog), aluminum 99-531015 PRTS Hader-EDS Combo Clips (18) 6 white, 6 yellow, 6 red and 1 seating instrument 99-531009 Hader-EDS ar, short plastic (6) Green 99-531030 Hader-EDS Metal Housings (6) Gold 99-531060 SWISSLOC NG TTCHMENT SwissLoc NG mm *L=4.5mm Housingø=3.4mm Plungerø=1.5mm X 89-600040 SwissLoc NG 6.0 mm *L=6.8mm Housingø=3.4mm Plungerø=1.5mm X 89-600060 SwissLoc NG 7.5 mm *L=8.0mm Housingø=3.4mm Plungerø=1.5mm X 89-600075 *Note: SwissLoc NG 7.5 can be reduced to 4mm. Length is measured in closed position from head of plunger to end of housing. TOOLS: SwissLoc NG Screwdriver 89-600010 SwissLoc NG Processing Jigs (2) 89-600015 SwissLoc NG 1.5mm Drill (1) 74-600615 PPM PLSTIC R PTTERNS (50mm) PPM ar 0 degree (3 short 3.7mm, 3 tall 8.0mm), blue 99-560000 PPM ar 2 degree (3 short 3.7mm, 3 tall 8.0mm), red 99-562000 PPM ar 4 degree (3 short 3.7mm, 3 tall 8.0mm), yellow 99-564000 TOOLS: PPM ar Mandrel 0 degree (for plastic or titanium bar) 99-560001 PPM ar Mandrel 2 degree (for plastic or titanium bar) 99-562001 PPM ar Mandrel 4 degree 99-564001 Hader-EDS Housing REPLCEMENT R CLIP WITH SCREWS & CKPLTE White ar Clip & Screw (2) ssembly and ackplate 57-8510 Fits original 2mm diameter bar. Used for overdenture bar restorations. Includes: 1 white clip, 2 screws and 1 backplate. PRTS White ar Clip only 57-8511 Screw only 57-8512 ackplate only 57-8513 ll product names referenced herein are trademarks of their respective companies. Copyright 2006 ttachments International, Inc., San Mateo, C 256 dditional Information: www.attachments.com
Non-Hex & Insertion Drivers Tools INSERTION DRIVERS The IO-TORQ (-T) and LT / R Systems were designed to facilitate the insertion of implant components. The IO- TORQ insertion tips may be utilized with the IO-TORQ hand held socket or the IO-TORQ wrenches. The LT / R (latch type) tips are used with right angle handpiece type drivers. IO-TORQ LT / R C D F G H J Socket Extension Slot Hex IMC IMC UM sht UM long C D E H Handle Slot Hex Complete UM Description Order # Order # io-torq LT/R Driver Hand Held Socket / Handle () 59-100190 58-100190 IO-TORQ Extension () 59-100195 N/ Slot Tip Short 59-100110 58-100110 Slot Tip Long (C) 59-100115 58-100115.050" Hex Tip Short 59-100120 58-100120.050" Hex Tip Long (D) 59-100125 58-100125.048" Hex Tip Short 59-100130 58-100130.048" Hex Tip Long 59-100135 58-100135 Dalla ona / ORS Hex Tip 59-100140 58-100140 Locator Tip, short 59-100146 58-100146 Locator Tip, long 59-100147 58-100147 Complete butment LT / R Tip (E) N/ 58-100170 IO-TORQ Tip / IMC, Short (F) 59-100171 N/ IO-TORQ Tip / IMC, Short (G) 59-100172 N/ UM Tip Short (H) 59-100150 58-100150 UM Tip Long (J) 59-100155 N/.9mm CS Hex Tip Short 59-100200 N/ STNDRD DRIVERS, -T WRENCHES & LT / R DRIVER Note: For Slot Screws do not exceed 10 N/cm of torque. C D Description Order # Standard Drivers and FG Drivers DDS.050" Hex Driver () 11-000007 DDS Slot Screwdriver () 11-000005 Lab.050" Driver (C) 11-000006 Friction Grip Driver (D) 11-000004 IO-TORQ Wrenches & LT / R Driver IO-TORQ Wrench 10 N/cm 59-100010 IO-TORQ Wrench 20 N/cm 59-100020 IO-TORQ Wrench 30 N/cm 59-100030 IO-TORQ Wrench 35 N/cm 59-100035 LT / R Driver 58-100000 ll product names referenced herein are trademarks of their Copyright 2007 ttachments International, Inc., San Mateo, C 259
Non-Hex & Compatible Reamers Lapping Tools REMERS The carbide reamers are used to refine the internal access hole of a castable cylinder. They also refine the seat for the head of the screw. Each carbide reamer and Pin Vise are sold separately. The Pin Vise will fit all carbide reamers. The Reamer fits all UM and IME European new style cylinders. Pin Vise Reamer Description Order # Reamer, UM butment Carbide.0880" (also fits & Paragon UCL Cylinders) (requires Pin Vise 40-000150) 11-000150 Pin Vise for Carbide Reamers.002 -.130" 40-000150 LPPING TOOLS The Lapping tools are used with diamond polishing paste to refine the fitting surface of the cast cylinder. We recommend that you use it not more than 5-6 times. For superior restorations, you may want to use the 1 micron white diamond lapping paste. The lapping tool fits the cylinders for the Complete butment, IME and UM. Description Order # UM, Lapping Tool and Guide Pin 11-000155 ll product names referenced herein are trademarks of their respective companies. Copyright 2006 ttachments International, Inc., San Mateo, C 258 dditional Information: www.attachments.com
Non-Hex & Screws for Original Parts SCREWS FOR ORIGINL COMPONENTS & & Hex Hex Hex C D E F G H IMC Conversion IMC Coping Screw IME Coping Screw IMC Fastening IMC Fastening IME Fastening Screw Securing Screw Hex Head Screw for Plastic Cylinder for Gold Cylinder for Gold Cylinders ar Clip to & ack Plate Implant Screw LL SCREWS HVE.050" HEX except ack Plate Screw (slot) Description Order # Order # mm mm IMC Conversion Screw,.050" Hex () 57-8198C 57-8197C Used when converting from IME to IMC butment. Threads must be shortened to appropriate length. mm ONLY fits IMC butment mm Fits both IMC & IME butments. 2.2mm ø head. IMC Coping Screw,.050" Hex () 57-8158C 57-8157C Used for overdenture bars. Screw has 2.8mm diameter head. IME Coping Screw,.050" Hex (C) 57-8534 57-8535 Used for overdenture bars. Screw has 2.8mm diameter head. IMC Fastening Screw for Plastic Cylinder,.050" Hex (D) 57-8146C 57-8144C Screw has 2.4mm diameter head. IMC Fastening Screw for Gold Cylinder,.050" Hex (E) 57-8196C 57-8199C Screw has 2.2mm diameter head. IME Fastening Screw for Gold Cylinder,.050" Hex (F) 57-8905 57-8906 Hex is in base of screw head allowing screw head to be shortened if necessary. 2.2mm ø head. Screw to Secure ar Clip to ack Plate &, slot (G) 57-8510 57-8510 For securing plastic clip to the ack Plate ONLY. Screw for & Hex Head Implant,.050" Hex (H) 57-440052 57-440052 For Hex Head & Implant ONLY. Note: For detailed dimensions of screws see Reference Charts immediately following this page. ll screws have.050" hex. IME butment Inner thread is located in TOP portion of abutment IMC butment Inner thread is located in OTTOM portion of abutment Note the difference in placement of screw threads in the abutments. IME threads are located at the top, IMC threads are located at the bottom. ll product names referenced herein are trademarks of their Copyright 2007 ttachments International, Inc., San Mateo, C 261 dditional Information: www.attachments.com