Thermostatic Mixing Valves

Similar documents
ASSE 1016, 1069 & 1070

See Mixing Valve Catalog (PHBRMIX) for more detailed information about the products in this section.

CERT. TO ASSE STD 1016 AND AND AND 1017 WT. LBS.

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

AMX300 DirectConnect Mixing Valve Kits

Understanding Potential

Pressure Drop Basics & Valve Sizing

Domestic Hot Water Systems and Plumbing Products

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

WATER PRESSURE REDUCING VALVES

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m.

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

HL Series - Commercial Heaters Tankless Water Heating Solutions

SECTION Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters)

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

Controlling Legionella in Plumbing Systems. Presented by: Julius Ballanco, P.E. President, JB Engineering and Code Consulting, P.C.

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Plumbing Identification and Damage Assessment Guide

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

PLUMBING SUBMITTAL

High kw Electric Tankless Water Heater Troubleshooting Guide

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

Float and Thermostatic Traps Series H, C and X

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

Therm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV

FIRING RANGE PHASE 1 DESIGN

Effective Date: January 1, 2009

Tepid Water Solutions for you and your customers

When Should Examination Preparation Begin?

How To Fix A Leaky Water Heater

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

Georgia State Amendments to the International Plumbing Code

STABITHERM INSTALLATION & SERVICE BOOKLET

GOLD Plus 30/40/60/80

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Water Heater Sizing TS Saturday 2:15pm 5:15pm J. Joe Scott CPD, FASPE, LEED

Design Utility Lever Thermostatic Bath Shower Mixer

What to Expect From the Examination. How to Study the Plumbing Codes

TMV3 THERMOSTATIC MIXING VALVES

PRESSURE REDUCING CONTROL VALVE

INSTALLATION GUIDE AND OWNER S MANUAL

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Indirect-fired Steam & Boiler Water Heaters

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

B. Shop Drawings: Diagram power, signal, and control wiring.

Electric Water Heater

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

SHOWERS SHOWERS

Chill 4 Hole Bath Shower Mixer

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

Commercial Electric Water Heater

EMERGENCY PLUMBING FIXTURES

WATER. Water Management Protect your building from water damage. Intent. Information & Tips

SIZING OF WATER PIPING SYSTEM

Water Pressure Reducing Valves

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Trin & Stor Model Numbers: ST Series Version Date:

REGULATORS 175/153 Series

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Frequently Asked Questions

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM

DECONTAMINATION PRODUCTS

Indirect-Fired Water Heaters

AIR LINE VALVES AND GAUGES

ANSI / ISEA Z Compliance Checklist

15430 SAFETY SHOWERS AND EYEWASHES

Code Reference Competitive Comparison

Introduction. Kitchens

Why Chicago Faucets Cartridges?

Artisan Thermostatic Bath Shower Mixer

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

WATER HEATERS. If your water heater tank is leaking, then your course is clear: buy a new unit. But if it isn t, your answer is less obvious.

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Element D Services Plumbing

2012 British Columbia Plumbing Code Update

stainless steel pre-assembled manifolds

Guidance Note on Flushing

Heating Water by Direct Steam Injection

Rexroth Hydraulic Pump A10VO Series User Manual

Controlling Scalding Risks from Bathing and Showering

INSTALLATION, OPERATING, AND SERVICE INSTRUCTIONS

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Custom Shower Design Guide

MAC FAUCETS. Owner s Manual. Models: FA444

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

NITROUS TRANSFER PUMP INSTRUCTIONS

Dominic i Barbato Dpt. Of Building and Safety (818) domenico.barbato@lacity.org

Transcription:

Thermostatic Mixing Valves Reliable, ASSE-listed valves from a recognized leader in flow-control products W atts.com

The Trusted Choice for Thermostatic Mixing Valves Watts provides a complete thermostatic mixing valve (TMV) line. Reliable products for safe, accurate control of water temperature from point-of source to point-of-use Products tested and listed to relevant ASSE standards (1017, 1069 & 1070) LavSafe tempering faucet, the only ASSE 1070-listed faucet available in North America One-of-a kind products include LavSafe and USG-B under-sink guardian, which reduce installation time by up to 50% Extensive distribution network ensures product availability Provided by a stable, industry leader with more than 140 years in the business Common Applications for Thermostatic Mixing Valves Residential Homes, apartments, and dormitories Commercial Businesses, hotels, and office buildings Institutional Healthcare facilities, military facilities, universities, schools and correctional institutions

Mixing Valve Overview Addressing The Dangers of Hot Water Every year, thousands of people suffer injury or become ill as the result of water stored or used at inappropriate temperatures, leading to the potential for: Serious thermal shock and scalding injuries suffered in bathtubs, sinks, and showers Illness caused by water-borne bacteria such as Legionella Thermal Shock One source of injuries in the shower is slips and falls in reaction to a sudden increase or decrease in water temperature, known as thermal shock. If the supply of cold or hot water is lost, the water flow should be shut down immediately. Termination of the flow reduces the risk of instinctive reaction to quickly move away from a too-hot or too-cold water stream. Scalding Scalding incidents can occur in the home and in commercial or institutional facilities. The tender skin of very young children and the slow reaction time of the elderly and the handicapped make them particularly vulnerable to serious hot water burns. 1 Other causes include faulty water heater thermostats and water temperatures set too high. Also, temperature valves at the domestic hot water source can malfunction or be missing altogether. Water heaters are typically set to temperatures above 131 F (55 C) to prevent development of harmful bacteria in the water supply, however, at that temperature scalding can occur. 131 F The temperature that is required to kill Legionella bacteria in a water heater Legionella Bacteria Legionella bacteria are responsible for Legionnaires' Disease and Pontiac Fever, a less severe, non-pneumonia, flu-like disease associated with and likely caused by Legionella. In a domestic water system Legionella can find an ideal host environment of warm water temperatures (95-115 F) and rapidly colonize, forming dangerous concentrations. A widely accepted and preferred method of maintaining Legionella is to maintain the hot water system storage temperature continually at or above 140 F. 2 1 Understanding Potential Water Heater Scald Hazards, American Society of Sanitary Engineering (ASSE) Scald Awareness Task Group, http://www.asse-plumbing.org/waterheaterscaldhazards.pdf, March 2012. 2 David Kahane Legionnaires Disease in Hospitality, A New Face on a Familiar Problem, Forensic Analytical, 2013.

Mixing Valve Overview Advantages of Watts Thermostatic Mixing Valves Since 1874 Watts has set the standard for valve technology. Watts thermostatic mixing valves: Maintain and limit mixed hot water to a desired, selectable temperature Provide a way to control outlet temperatures to help mitigate the risk posed by unmonitored, untempered water Enable safe, accurate control of hot water from its source through to its final use, regardless of how the supply temperatures or pressures vary over time Provide more precise control than pressure balancing mixing valves, which do not automatically control outlet temperatures or limit them should supply temperatures dramatically increase or decrease Union inlets for easy maintenance Temperature locking mechanism prevents unauthorized adjustment of set temperature Integral checks prevent cross-flow Integral screens keep debris away from the valve Advanced thermal actuator provides near-instantaneous response American Society of Sanitary Engineering (ASSE) Standards 1016, 1017, 1069, and 1070 ASSE 1016 covers the delivery of water at the individual fixtures that are adjusted and controlled by the user, addressing very precise and immediate temperature regulation requirements. It pertains to three types of valves: pressure balancing, thermostatic, and combined pressure balancing/thermostatic. ASSE 1017 is concerned with valves used at the source of hot water for distribution to the supply system. ASSE 1017 listed devices should never be used to deliver water directly to the user. These valves should be used in combination with an ASSE 1016, ASSE 1069, and/or ASSE 1070 listed device. ASSE 1069 was developed for applications such as gang showers and sitz baths, that supply water at a preset temperature through a single pipe supply. Mixing water downstream of an ASSE 1069 listed device is not allowed. ASSE 1070 addresses control of maximum water temperature delivered to a fixture or group of fixtures, such as sinks, lavatories or bathtubs. An ASSE 1070 device may perform the final temperature regulation or water may be further tempered downstream with the addition of cold water. For more information, visit ASSE-plumbing.org.

Mixing Valve Overview How Watts Mixing Valves Work Once tempered water is in use, a thermostat in the mixing chamber of the valve senses the outlet temperature and automatically positions a seat assembly, which controls the flow of hot and cold water supplied to the mixing chamber. If the mixed outlet temperature increases, the thermostat will expand, moving the seat assembly to allow the cold water inlet port to open more fully and at the same time restrict the hot water inlet port. Conversely, if the mixed outlet temperature decreases, the thermostat will contract, moving the seat assembly to allow the hot water inlet port to open more fully and at the same time restrict the cold water inlet port. In both cases the mixed outlet water temperature is automatically and continually maintained at the preset temperature within the tolerances of the valve. In the event of a cold or hot water supply failure, the seat assembly moves to an extreme position, shutting off the hot or cold inlet water port. A mechanical adjustment permits selection of the desired outlet water temperature within range of the valve. End Connections To facilitate installation and servicing of a Thermostatic Mixing Valve, Watts offers a variety of end fitting configurations, including union fittings (female threaded, solder, CPVC, PEX, and Quick-Connect end connections). Please refer to valve models for specific availability of end connection options. Solder Check Module Stem Assembly Hot Inlet Cold Inlet Threaded Thermostat Funnel Spring Plunger Seat CPVC Mixed Outlet PEX Quick-Connect

At the Fixture Heat loss in the system piping can result in varying temperatures of the hot and cold water supplied to fixtures. The use of thermostatic mixing valves helps ensure the selected mixed-water temperature at the point of delivery to the fixture. In Supply Systems The water temperature discharged directly from a water heater can vary by ±10 F or more. This can be attributed to tolerance of control devices, inlet water temperature changes, and/or stacking (higher water temperatures at the top of the water heater). Using a thermostatic mixing valve helps ensure constant outlet water temperature even with variations in hot or cold water supply temperature. 3 If a water heater is used at lower temperatures, high-flow demand situations can cause the hot water temperature to drop if the recovery time of the water heater is not sufficient for the flow demand. Using a hot water extender or mixing valve allows the water heater to operate at higher temperatures, extending the effective system flow rate and helping prevent the growth of Legionella bacteria. Supplying peak demands for domestic hot water often requires high capacity water heaters with high recovery rates. Using a hot water extender can reduce the size/btu requirements needed to provide capacity for peak system demands. 3 Please refer to specification for the selected model to determine the allowable inlet temperature range to maintain a desired outlet temperature.

Solutions Point-of-Source Solutions For use at the source of hot water in commercial and institutional settings, Watts mixing valves provide reliable temperature control of domestic and hydronic hot water distribution systems. In this way, they extend the capacity of water heater storage tanks and tankless water heaters. LF1170 Point-of-Use Solutions Watts mixing valves are used to provide tempered water in sinks, showers, and lavatories in commercial, educational, and institutional environments such as restaurants, schools and universities, hospitals, nursing homes, and public restrooms. LFUSG-B Innovation LavSafe Thermostatic Faucets With integrated thermostatic control, these faucets meet the temperature protection requirements of ASSE 1070 to safely deliver hot water. All key components are above the sink level, providing easy access that streamlines installation and maintenance of these stylish faucets. P1070 NOTICE The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product.

Point-of-Use Series 1070, P1070, G1070 and GP1070 LavSafe Thermostatic Faucets P1070 GP1070 Sizes: 3 /8" (10mm) Eliminates installation of under-the-counter thermostatic valve Watts' Advanced Thermal Actuator quickly compensates for pressure and temperature fluctuations Mixes hot and cold water to deliver tempered water within specified range Heavy duty Lead Free 4 brass body for durability and to comply with Lead Free 4 installation requirements Copper supplies feature integrated check valves Self-contained cartridge installs in a minute to simplify repairs Virtually shuts off hot water flow in the event of cold water failure ASSE 1070, IAPMO cupc, NSF-ANSI 61 Section 9 Annex G, WaterSense RT, and Handicapped Accessible approved Series LFUSG Under Sink Guardian Thermostatic Mixing Valves LFUSG-B-M2 Sizes: 3 /8" (10mm) Lead Free 4 brass body construction Installs easily between the stop valves and faucet Includes tamper-resistant locking nut to prevent accidental mis-adjustment Built-in check valves prevent migration of hot water to cold and cold water to hot water piping Provided with cap for three-port application Integral strainer with 40 mesh stainless steel screens to filter out debris ASSE 1070, cupc approved LFMMV-M1 LFMMV-QC-M1 Series LFMMV Thermostatic Mixing Valves Sizes: 1 /2" - 1" (15 25mm) Solid wax hydraulic principle thermostat ensures dependable mixing of hot and cold water Thermostat controls both hot and cold water Solder, threaded, PEX or CPVC, Quick-Connect end connection models available Adjustment cap with locking feature ASSE 1017, 1069, 1070 listed IAPMO cupc listed Integral filter washers and check v alves 4 The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.

Point-of-Source Series LF1170 and LFL1170 Thermostatic Mixing Valves Sizes: 1 /2" - 1" (15 25mm) Solid wax hydraulic principle thermostat ensures dependable mixing of hot and cold water Thermostat controls both hot and cold water Models available with solder, thread, PEX, Quick-Connect or CPVC end connections Integral filter washers and check valves Adjustment cap with locking feature CSA B125 Certified ASSE 1017 listed 5 and IAPMO UPC LF1170-M2 Series LFN170 Hot Water Master Mixing Valves Sizes: 3 /4" - 2" (20 50mm) Lead Free 6 cast copper silicon alloy Paraffin-based thermostat to sense and adjust outlet temperature Dirt and lime resistant poppet and seat design Virtual shutoff if supply pressure fails Vandal-resistant locking mechanism to secure temperature setting Available with or without checkstops ASSE 1017 listed 5, cupc approved LFN170-M3-CSUT Series LF70A and LFL70A Hot Water Extender Mixing Valves Sizes: 1 /2" - 3 /4" (15 20mm) Hydraulically operated thermostat that opens a spring-loaded check in cold water inlet Simple maintenance thermostat assembly is easily removed and replaceable as a unit Finger Tip Dial adjustment cap Sweat or threaded connections Stainless steel springs LF70A 5 ASSE 1017 listing is for valves used in hot water source applications. 6 The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.

ASSE Standards A Comparison of ASSE 1069, 1070 and 1071 with revised 1016 and 1017 standards Standard ASSE 1017-2009 ASSE 1069-2005 ASSE 1070-2004 Watts Applicable Products LFL1170, LF1170, LFMMV, LFN170 LFMMV LFMMV, LFUSG-B, LavSafe faucets Title Temperature Activated Mixing Valves for hot water distribution systems Automatic Temperature Control Mixing Valves Water Temperature Limiting Devices Category Tempered water distribution Point-of-use distribution adjustment by installer Application Hot water source/boiler Gang showers, sitz baths, spas, gang lavatories Point-of-use or distribution Sinks, lavatories, baths Types Thermostatic only Thermostatic only Thermostatic only Valve Temp Range - Outlet Temperature Tolerance Pressure Change Test (Hot & Cold) Minimum adjustable range 105 F - 120 F 100 F - 115 F 105 F - 110 F + - 3 F to + - 7 F (depending on valve size/capacity) + 5 F lasting more than 1.5 seconds within first 5 seconds - 9 F lasting more than 1 second within first five seconds No pressure change test 20% up and down for cold & hot supply 20% up and down for cold & hot supply + - 7 F Temperature Change Test (Hot) 25 F hot water increase 25 F hot water increase 25 F hot water increase Flow Test Not applicable Must be 90% of manufacturer s published flow Must be 90% of manufacturer s published flow Minimum Tested Flow to Provide Control 50% of flow @ 10psid 2.5 gpm or less Manufacturer s minimum stated flow Cold Water Failure Allowance Not applicable 0.5 gpm for 1 2 and 3 4 devices 1.0 gpm for 1 and larger devices Life Cycle Not applicable 100,000 cycles 100,000 cycles 0.2 gpm or 20% of minimum flow, whichever is greater before 120 F

ASSE 1016-2011 ASSE 1062-2006 ASSE 1071-2012 For applicable products, see Powers, A Watts Water Technologies Company at PowersControls.com Automatic Compensating valves for individual showers and tub-shower combinations Point-of use, bather or bather attendant interface Shower or tub/shower combination only Type P - Pressure Balancing Type T - Thermostatic Type T/P - Combination Full cold to 105 F minimum, 120 F maximum T/P and P = + - 3.6 F T = +5.4 F, -9.0 F Temperature Actuated, Flow Reduction valves for individual fixture fittings (TAFR) In-line high temperature limit devices Faucets, shower heads, tub spouts dramatically reduce flow when temperature exceeds actuation point Thermostatic only Not applicable Maximum actuation temperature 120 F or less Temperature Activated Mixing valves for plumbed emergency equipment Point-of-use or distribution Eye washers, eye/face washes, drench showers and combination units Thermostatic only 65 F - 95 F Varies depending on capacity. Also, hot water control has a tighter tolerance than cold water control. P = 50% up/down T = 20% up/down T/P = 50% up/down P = Does not test for temperature change T = 25 F hot water increase T/P = 25 F hot water increase Minimum 2.25 gpm Not applicable Not applicable 0.25 gpm within five seconds when temperature exceeds 120 F and one second once actuation temperature exceeds 129 F Not applicable 25 F hot water increase HW Failure, CW flow = manufacturer s rated by-pass flow @ 30 psid 2.5 gpm Not applicable 3.0 gpm or manufacturer s stated minimum P, T, T/P < 0.5 gpm within 5 seconds before 120 F Not applicable CW failure, HW flow gpm not to exceed 0.5 100,000 cycles all 125,000 cycles Not applicable

Represented by: A Watts Water Technologies Company USA: Tel: (978) 689-6066 Fax: (978) 975-8350 Watts.com Canada: Tel: (905) 332-4090 Fax: (905) 332-7068 Watts.ca Latin America: Tel: (52) 81-1001-8600 Fax: (52) 81-8000-7091 Watts.com F-MXV 1540 MF10630 2015 Watts