USER'S GUIDE. Vaisala HUMICAP Humidity Transmitter Series HMP140A U175EN15



Similar documents
Duct Humidity Transmitter

T0118 T2118 T3118. Instruction Manual

Pressure transmitter For general industrial applications Model A-10

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Digital inductive conductivity transmitter

Contents. Document information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Digital input modules

400 Series - Mini USB Buccaneer

Instruction Manual. T3111 T3111L T3111P T3111Ex

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Vaisala Weather Transmitter WXT510 The Most Essential of Weather

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Hand-held thermometer Model CTH7000

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

T7560A,B,C Digital Wall Module

TC-9102 Series Surface Mount Temperature Controllers

How To Use A Ds340 (Dsp)

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

HMI display Installation Guide

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Features. Picture. Specifications

Standard Buccaneer - Ethernet

GREISINGER electronic GmbH

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

HARTING Ethernet Cabling 8-poles Overview

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

ATL Fuel Level Sender Probes

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

PART 1 - INTRODUCTION...

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

J TB/TW Temperature limiter, temperature monitor

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

A99B Series Temperature Sensors

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

How To Read A Pipe From A Sensor

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ALARMLINE ANALOGUE Linear Heat Detection System

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Humidity Sensor. Model HU-224/225

Processor. Installation Guide

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Modular I/O System Analog and Digital Interface Modules

Product and functional description

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Redundancy Module QUINT-DIODE/40

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

MP-4000 Alarm List (Software version or later)

Description. Dimensions. Features. precision works better

Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.

LUT Luminescence scanners: Seeing what no-one else can

W 36: Mastering complex tasks reliably

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

HARTING Ethernet Cabling 4-poles Overview

Combustible Gas Transmitter RK-05

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Wind Sensor W-RS485 with RS485 Interface

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

PD 100A. Printing data system

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

08. SEK IDC CONNECTORS

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Standard Buccaneer - USB

Manual Ranging MultiMeter

Toroidal Conductivity Sensor

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

STRATO LED Drivers 70W, Single output

Operating Instructions

Original instructions Tina 3A/Aps Adaptor unit

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

Transcription:

USER'S GUIDE Vaisala HUMICAP Humidity Transmitter Series HMP140A U175EN15

PUBLISHED BY Vaisala Oyj Phone (int.): +358 9 8949 1 P.O. Box 26 Fax: +358 9 8949 2227 FIN-00421 Helsinki Finland Visit our Internet pages at http://www.vaisala.com/ Vaisala 2006 No part of this manual may be reproduced in any form or by any means, electronic or mechanical (including photocopying), nor may its contents be communicated to a third party without prior written permission of the copyright holder. The contents are subject to change without prior notice. Please observe that this manual does not create any legally binding obligations for Vaisala towards the customer or end user. All legally binding commitments and agreements are included exclusively in the applicable supply contract or Conditions of Sale.

U175en-1.5 HMP140A SERIES Contents 1. PRODUCT DESCRIPTION...1 2. TO BE NOTED WHEN MEASURING HUMIDITY...2 3. INSTALLATION...3 3.1 Selecting the place of installation...3 3.2 Mounting...3 3.2.1 Mounting the HMP141A...4 3.2.2 Mounting the HMP142A...4 3.2.3 Mounting the HMP143A...5 3.3 Electrical connections...6 3.4 Connectors and potentiometers on the main PCB...7 3.5 Selecting the outputs...7 3.6 Connection to an AC supply...8 4. CALIBRATION...9 4.1 One-point humidity calibration...9 4.2 Two-point humidity calibration...9 4.2.1 Two-point humidity calibration procedure...9 4.3 Temperature calibration...10 4.4 Calibration table...11 5. MAINTENANCE... 11 5.1 Replacing the HUMICAP 180 sensor and the filter...11 6. TECHNICAL DATA...12 6.1 Relative humidity...12 6.2 Temperature...12 6.3 General...13 6.4 Electromagnetic compatibility...14 6.4.1 Emissions...14 6.4.2 Interference...14 7. SPARE PARTS AND ACCESSORIES...14 APPENDIX 1: CURRENT OUTPUT MODULE APPENDIX 2: SETTINGS OF THE LOCAL DISPLAY APPENDIX 3: HMP143A PROBE CABLE EXTENSION TECHNICAL DATA 1999-12-08 i

HMP140A SERIES U175en-1.5 This page intentionally left blank. ii 1999-12-08

U175en-1.5 HMP140A SERIES 1. PRODUCT DESCRIPTION The HMP140A series transmitters are reliable and easy to use instruments for the measurement of relative humidity and temperature. The series consists of three different types of transmitters to be chosen according to the requirements of the application: HMP141A for wall installations HMP142A for duct installations HMP143A for installation in tight places The configuration can be chosen from various possibilities to meet the specific requirements of the customer. The transmitters can be ordered with a blank cover or a cover with a local display which outputs relative humidity and temperature readings. The reading to be displayed is chosen with a pushbutton on the cover and the desired temperature unit (Celsius or Fahrenheit) can be chosen with a jumper (see Appendix 2). All HMP140A transmitters measure relative humidity in the range of 0...100 %RH and temperature from -40 to +60 C; the measurement is temperature compensated. The HMP140A transmitters have four different analogue outputs: 0...20 ma (4...20 ma), 0...1 V, 0...5 V and 0...10 V. The outputs are also scalable if necessary, e.g. 4...20 ma from 0...20 ma. The durable plastic cover provides IP65 protection from dust and sprayed water. The HMP140A transmitters are therefore suitable for most indoor and outdoor applications, including those with high humidities like indoor swimming pools etc. These versatile transmitters are also easy to install and to use. When necessary, they can be recalibrated on site with Vaisala s HMI41 indicator equipped with an appropriate probe and optional calibration cable (19116ZZ). The HMP140A series transmitters incorporate the HUMICAP 180 sensor, the operation of which is based on the changes in its capacitance as the thin polymer film absorbs water molecules. The sensor is immune to most chemicals and has an excellent long-term stability. The temperature is measured with a Pt 1000 sensor. 1999-12-08 1

HMP140A SERIES U175en-1.5 2. TO BE NOTED WHEN MEASURING HUMIDITY In the measurement of humidity and especially in calibration, it is essential that the temperature equilibrium is reached. Even a slight difference in the temperature between the measured object and the sensor causes an error. For example, at +20 C (+ 68 F) and 50 %RH, a temperature difference of +1 C between the measured object and the sensor causes an error of +3 %RH. If relative humidity is 90 %RH, the error is about +5.4 %RH. The error is at its greatest when the temperature of the sensor differs from that of the surroundings and the humidity is high. A few degrees difference in temperature may cause water to condense on sensor surface. Efficient ventilation accelerates evaporation whereas in an unventilated space, it may take hours. The HUMICAP 180 sensor returns to its normal functioning as soon as water has evaporated. Any contaminated water condensing on the sensor may shorten its life span and change the calibration. drh (%RH) 10 9 8 7 6 5 4 3 2 1 0-40 -20 0 20 40 60 80 100 Temperature ( C) Figure 2.1 Measurement error at 100 %RH when the temperature difference between the ambient and the sensor is 1 C 2 1999-12-08

U175en-1.5 HMP140A SERIES 3. INSTALLATION 3.1 Selecting the place of installation Select a place that gives a true picture of the environment or process and is as clean as possible. Air should circulate freely around the sensor. A rapid air flow is recommended as it ensures the same temperature for the ambient air and the sensor head. Install the transmitter in a place where no cold or hot spot can develop. If the sensor head is installed in a duct or channel where the temperature is different from the ambient temperature, insulate the point of entry; this is particularly important if the transmitter is installed with the sensor head pointing downwards. Vertical installation of the HMP142A and HMP143A is not recommended; they should be mounted with the sensor head horizontally whenever possible. An uninsulated installation might lead to condensation on the sensor head and even if no condensation occurs, the resultant air flow may change the temperature near the sensor head and distort the readings. 3.2 Mounting The electronics of the HMP140A series can be disconnected for ease of installation and service. The housing can be conveniently installed and the electronics then consequently mounted. For service and maintenance purposes the electronics can be disconnected without disconnecting the cabling, and taken to an appropriate environment for necessary adjustments. 60 6.5 83.5 60 4.2 Figure 3 Drilling dimensions (in mm) 1999-12-08 3

HMP140A SERIES U175en-1.5 3.2.1 Mounting the HMP141A The optimal installation of the HMP141A is with the sensor head pointing downwards. Upward mounting should be avoided due to internal heat transfer. 1. Mounting and wiring: cable feedthrough on the surface or in the connection box. 1 2. Mount the protection lid to the connection box. 3. Push the sensor head through the protection lid as in figure and connect the electronics housing to the connection box. Make sure that the pins at the bottom of the electronics housing are in contact with the screw terminal. 4. Fasten the four connecting screws of the electronics housing. 5. Place the sensor head into the protection lid. 6. Close the cover and fasten the two connection screws. 3 4 4 2 6 4 4 5 Figure 3.2.1 Mounting of the HMP141A 3.2.2 Mounting the HMP142A The HMP142A transmitter should be mounted with the sensor head horizontally whenever possible. This way, any water that might condense on the tube cannot flow on to the sensors. When there is no alternative but to install the sensor head in the process vertically, the point of entry must be carefully insulated. 4 1999-12-08

U175en-1.5 HMP140A SERIES 225 Ø 15 Ø 12 Figure 3.2.2 Dimensions of the HMP142A (in mm) 3.2.3 Mounting the HMP143A The cable model HMP143A should also be mounted with the sensor head horizontally whenever possible. This model is provided with two plastic nuts and a gasket. Mount the nuts on the sensor head: disconnect the cable from the transmitter, insert the nuts and fasten them on the sensor head. Then reconnect the cable. A mounting flange is also available (see Fig. 3.2.3). The cable can also be extended up to 100 metres; see Appendix 3 for details. duct wall sealing a plugged hole for reference measurements flange M12x1 Ø 12 69 supporting bar Figure 3.2.3 Dimensions of the HMP143A probe (in mm) and installation in a channel with the help of flange (part no. HMP233FA) and supporting bar 1999-12-08 5

HMP140A SERIES U175en-1.5 3.3 Electrical connections The wiring can be done in either of the two ways shown in Figure 3.3. mounting on a juction box surface mount GND Tout SHIELD RHout Vs (OHFWULFDOÃFRQQHFWLRQVÃÃP$ÃRXWSXW *1' (OHFWULFDOÃFRQQHFWLRQVÃÃ9ÃRXWSXW *1' 9V $ $ 7 RXW 6+,(/' 5+ RXW 9V 9 9 7 RXW 6+,(/' 5+ RXW 9V 9V Figure 3.3 Electrical connections Outputs 0...20 ma (4...20 ma) 20...35 VDC 17...24 VAC min. R ( ohm) 12 + L VDC 50 0...1 V 9...35 VDC 9...24 VAC 0...5 V 15...35 VDC 12...24 VAC 0...10 V 20...35 VDC 16...24 VAC Current consumption Electrical connections 6...10 ma + output currents screw terminals for 0.5-1.5 mm 2 wires (AWG 15...20), stranded wires recommended 6 1999-12-08

U175en-1.5 HMP140A SERIES 3.4 Connectors and potentiometers on the main PCB DISPLAY CONNECTOR Test connector for factory use; leave the jumper as indicated here Test connector for one point calibration Connectors for the current module PROBE CONNECTOR VIO SHIELD GRN YEL BRN X15 Toffset RHoffset RHgain Tgain Spare jumpers Toutput selection X16 RHoutput selection Figure 3.4 Connectors and potentiometers on the main PCB 3.5 Selecting the outputs The HMP140A series transmitters can be ordered with the desired output signals already selected. If the outputs are changed, the jumpers have to be moved to corresponding places (see Figure 3.5). For current outputs, see Appendix 1. Jumper changes may change the output < ±0.15 %FS within the chosen range; this usually does not give cause to recalibration. DISPLAY CONNECTOR PROBE CONNECTOR VIO SHIELD GRN YEL BRN Test connector for one point calibration Toutput selection Voltage Toutput selection 0-1V RHoutput selection 0-5V 0-10V Voltage RHoutput selection 0-1V 0-10V 0-5V Figure 3.5 Jumper positions for voltage outputs 1999-12-08 7

HMP140A SERIES U175en-1.5 3.6 Connection to an AC supply The HMP140A transmitters can also be connected to an AC supply without an external rectifier. However, when two or more transmitters are connected to one 24 VAC transformer, a common loop is formed and there is an increased risk of a short-circuit. To avoid this, always use separate floating supply for each transmitter (see Figure 3.6 A). However, if several transmitters have to share one transformer, always connect the phase ( ) to + connector in each transmitter (see Figure 3.6 B). A) NO COMMON LOOP FORMED - RECOMMENDED HMP140 transmitter Controller HMP140 transmitter B) COMMON LOOP FORMED - NOT RECOMMENDED! HMP140 transmitter Controller supply voltage signal output supply voltage signal output supply voltage signal output supply voltage signal output shared common line HMP140 transmitter Figure 3.6 Connecting the transmitters to a 24 VAC supply 8 1999-12-08

U175en-1.5 HMP140A SERIES 4. CALIBRATION 4.1 One-point humidity calibration The HMP140A series transmitters should be recalibrated approximately once a year. The interval depends on the operating conditions and the required accuracy. One-point calibration can be done with Vaisala s portable HMI41 indicator equipped with an appropriate probe and optional calibration cable (19116ZZ). The cable is connected to a test connector either on the main component board of the HMP140A or, if a current output module is installed, on the module (see Figure 4.1). For more detailed instructions, see the operating manual of the calibration cable (U218en). DISPLAY CONNECTOR PROBE CONNECTOR VIO SHIELD GRN YEL BRN Test connector for one point calibration on the main PCB Test connector for one point calibration on the current module X15 Current Module Figure 4.1 X16 Location of the test connectors 4.2 Two-point humidity calibration The calibration can also be done with the HMK11 or the HMK13B Calibrator, or the instrument can be sent to Vaisala or a Vaisala representative. 4.2.1 Two-point humidity calibration procedure Leave the calibrator and the transmitter for at least 30 minutes in the same space so that their temperatures have time to equalize. Place the probe into the calibration hole of the LiCl bottle in the humidity calibrator. Wait for 10 minutes. 1999-12-08 9

HMP140A SERIES U175en-1.5 Use the RH offset potentiometer (see Figure 4.2) to adjust the output signal to the value given in the calibration table (Chapter 4.4). Place the probe into the calibration hole of the NaCl bottle in the calibrator. Wait for 10 minutes. Check that the reading corresponds within the desired accuracy to the reading given in the calibration table. If not, adjust the reading with the RH gain potentiometer (see Figure 4.2). Check again the reading at the first point and adjust if necessary. DISPLAY CONNECTOR PROBE CONNECTOR Tgain Toffset RHoffset RHgain Figure 4.2 Calibration potentiometers 4.3 Temperature calibration One point temperature calibration can be performed with the HMI41 equipped with an appropriate probe and optional calibration cable if the accuracy of +0.5 C is sufficient. For further details, see the operating manual of the HMI41 and calibration option. 10 1999-12-08

U175en-1.5 HMP140A SERIES 4.4 Calibration table Temperature C 15 20 25 30 35 F 59 68 77 86 95 LiCl %RH *) 11.3 11.3 11.3 11.3 4...20 ma ma 5.81 5.81 5.81 5.81 0...20 ma ma 2.26 2.26 2.26 2.26 0...1 V V 0.113 0.113 0.113 0.113 0...5 V V 0.565 0.565 0.565 0.565 0...10 V V 1.13 1.13 1.13 1.13 NaCl %RH 75.6 75.5 75.3 75.1 74.9 4...20 ma ma 16.10 16.08 16.05 16.02 15.98 0...20 ma ma 15.12 15.10 15.06 15.02 14.98 0...1 V V 0.756 0.755 0.753 0.751 0.749 0...5 V V 3.780 3.775 3.765 3.755 3.745 0...10 V V 7.56 7.55 7.53 7.51 7.49 *) LiCl solution must not be used or stored in temperatures below +18 C (+64 F); otherwise the equilibrium humidity of the salt solution changes permanently Table 1 Greenspan s calibration table with output values according to the chosen scale 5. MAINTENANCE 5.1 Replacing the HUMICAP 180 sensor and the filter Remove the damaged sensor and insert a new one. Handle the sensor by the plastic socket. DO NOT TOUCH THE SENSOR PLATE. Check the output after sensor change. If it deviates too much from the reference value, recalibrate the transmitter. Note that even after sensor change, the accuracy is still +7 %RH. Replace a dirty filter to ensure a maximum lifetime for the sensor. Do not try to clean the filter. The sensor can be cleaned with distilled water; if this does not help, replace the sensor. Do not use any mechanical methods. 1999-12-08 11

HMP140A SERIES U175en-1.5 6. TECHNICAL DATA 6.1 Relative humidity Measurement range 0...100 %RH Accuracy (including non-linearity and repeatibility) when calibrated against salt solutions (ASTM E104-85): 0...90 %RH +2 %RH 90...100 %RH +3 %RH Temperature dependence: drh (%RH) 2 1.5 1 0.5 0-0.5-1 -1.5-2 -20-10 0 10 20 30 40 50 60 T ( C) Response time (90%) 15 s at +20 C in still air (with sintered filter) Maximum error between the display and the outputs 0.2 %RH Humidity sensor HUMICAP 180 6.2 Temperature Measurement range -20...+60 C Typical accuracy at: +20 C +0.2 C -10...+40 C +0.3 C -20...+60 C +0.4 C Temperature sensor Pt 1000 IEC 751 Class B 12 1999-12-08

U175en-1.5 HMP140A SERIES 6.3 General Power supply current outputs: 20...35 VDC 17...24 VAC min. 12 + R (ohm) L 50 0...1 V 9...35 VDC 9...24 VAC 0...5 V 15...35 VDC 12...24 VAC 0...10 V 20...35 VDC 16...24 VAC Current consumption Electrical connections 6...10 ma + output currents screw terminals for 0.5-1.5 mm 2 wires (AWG 15...20), stranded wires recommended Alternative analogue output signals (scalable) 0...20 ma (4...20 ma) 0...1 V, 0...5 V, 0...10 V NOTE! Output scales correspond to 0 100 %RH and -40 +60 C. External loads for current outputs < 500 Ω 0...1 V > 1 kω (to ground) 0...5 V > 5 kω (to ground) 0...10 V >10 kω (to ground) Operating temperature range for electronics -20...+60 C with display option 0...+50 C Storage temperature range -40...+80 C Operating humidity range Bushing 0...100 %RH for 7...10 mm cables Sensor protection standard membrane filter, part no. 17039HM option plastic grid, part no. 17038 Cable length of HMP143A standard 2.5 m maximum 100 m (user extendable, see Appendix 3) Housing material ABS plastic Housing classification IP65 (NEMA 4) 1999-12-08 13

HMP140A SERIES U175en-1.5 6.4 Electromagnetic compatibility 6.4.1 Emissions Test: Setup according to: Radiated interference EN55022 (class B) 6.4.2 Interference Test: Setup according to: Performance: Electrostatic discharge IEC 801-2 criteria B RF-radiated fields IEC 801-3 criteria A (allowed temporary effect ±1 C in temperature) Electrical fast transients IEC 801-4 criteria B 7. SPARE PARTS AND ACCESSORIES Order code Description HMP233FA mounting flange for the HMP143A 19326 junction box for the HMP143A cable extension (seeapp.3) 1535 extension cable for the HMP143A (see Appendix 3) 17039HM membrane filter 17038 plastic grid HUMICAP 180 humidity sensor GUARANTEE Vaisala issues a guarantee for the material and workmanship of this product under normal operating conditions for one (1) year from the date of delivery. 14 1999-12-08

U175en-1.5 HMP140A SERIES Exceptional operating conditions, damage due to careless handling and misapplication will void the guarantee. 1999-12-08 15

HMP140A SERIES U175en-1.5 Appendix 1 APPENDIX 1: CURRENT OUTPUT MODULE Current module X15 Spare jumpers X16 RH output selection T output selection Figure 1 The current module is available only for HMP142A and HMP143A transmitters. To install the current module to connectors X15 and X16, first disconnect the jumpers (4 pcs). Insert them to the connector for spare jumpers (see Figure 1) and install the current module. Note that the module must be installed exactly as indicated in Figure 1. The jumpers for RH and T output selections must be connected in two middle pins of the connectors (Figure 1). Recalibrate the transmitter after having installed the current module. The maximum error in output without recalibration is ± 0.5 %FS. 1999-12-08 1

HMP140A SERIES U175en-1.5 Appendix 2 APPENDIX 2: SETTINGS OF THE LOCAL DISPLAY RH/T F C Figure 1 Location of the RH/T button and the C/ F jumpers The reading on the local display (relative humidity or temperature) can be chosen by pressing the RH/T button beside the display. At power-up, the display always shows the relative humidity reading. This can be changed to temperature reading by pressing the RH/T button once. Further pressings will change the reading between RH and T. The temperature unit ( Celsius or Fahrenheit) is chosen with the jumper on back of the local display unit. For C, the jumper is connected to the lower position and for F, it is connected to the upper position (see Figure 1). NOTE! The HMP140A series transmitters with the local display and current output cannot be re-scaled. 1999-12-08 1

HMI41 Appendix 2 HMI41-Uxxxen-1.1 2 1999-12-08

HMP140A SERIES U175en-1.5 Appendix 3 APPENDIX 3: HMP143A PROBE CABLE EXTENSION The cable of the HMP143A probe can be extended up to 100 metres with the help of the extension set including a junction box (part no. 19326) and a shielded six wire extension cable (part no. 1535). The junction box has a 5-pole terminal block and two PG9 lead-throughs. The extension cable is a shielded 6 x 0.22 mm 2 copper wire cable. This cable enables the extension without the need for transmitter adjustments. The user can also use some other cable for this purpose provided that it is a shielded copper wire cable. A shielded cable is recommended as it ensures the best possible EMC protection. The diameter of the cable should not exceed 7 mm as larger cables do not fit to the lead-through of the transmitter. The HMP143A probe head uses a combined signal ground and supply voltage ground. Ground wire resistance R c causes an offset type error to the transmitter output. The error is -0.11 x R c both in %RH and in C. This means that if maximum error allowed is e.g. -0.3 %RH or -0.3 C, the ground wire resistance should not exceed 2.7Ω. The resistance of the cable 1535 is minimized by connecting three wires as a ground conductor (see Figure 1). Possible error can also be leveled out by readjusting the transmitter offset (RH offset and T offset). PROBE CONNECTOR ON THE HMP143 PCB; THE COLOURS SHOW THE DIRECT CONNECTION OF THE HMP143 PROBE HEAD PROBE CONNECTOR VIO SHIELD GRN YEL BRN HMP143 PROBE CONNECTOR EXTENSION CABLE CABLE SHIELD JUNCTION BOX BLU GREY YEL BLK HMP143 CABLES VIO SHIELD GRN (ground) YEL BRN THREE WIRES CONNECTED TOGETHER (WHT, GRN, RED) Figure 1 Schematic of the extension set connections 1999-12-08 1

HMP140A Appendix 3 U175en-1.5 TECHNICAL DATA Junction box (part no. 19326) Housing: material ABS plastic dimensions 65 x 50 x 35 mm (l x w x h) classification IP 65 temperature range -40...+80 C Lead-throughs: size PG 9 cable diameter 4...7 mm housing classification IP 68 Terminal block: max. wire area 1.5 mm 2 Extension cable (part no. 1535) Type PFSK 6 x 0.22 mm 2 Wire resistance 80 Ω / km Covering braided, tinned copper wire Cross-sectional area of the wires 0.22 mm 2 Cover PVC, light grey Temperature range -30...+70 C Wire colours red, blue, green, yellow, white, black (DEF-STAN 61-12) 2 1999-12-08

www.vaisala.com