A Potentiometric Analysis of Fluoride Ion in Toothpaste



Similar documents
Chemistry 119: Experiment 7. Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets

Electrochemistry Revised 04/29/15

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Figure 1. A voltaic cell Cu,Cu 2+ Ag +, Ag. gas is, by convention, assigned a reduction potential of 0.00 V.

Electrical Conductivity of Aqueous Solutions

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide below. HF (aq) + NaOH (aq) H2O (l) + NaF (aq)

Experiment 9 Electrochemistry I Galvanic Cell

Acid Dissociation Constants and the Titration of a Weak Acid

Building Electrochemical Cells

CHAPTER 21 ELECTROCHEMISTRY

Ion Selective Electrodes

18 Conductometric Titration

Summer 2003 CHEMISTRY 115 EXAM 3(A)

Ch 20 Electrochemistry: the study of the relationships between electricity and chemical reactions.

Galvanic Cells and the Nernst Equation

Electrochemical Half Cells and Reactions

9. Analysis of an Acid-Base Titration Curve: The Gran Plot

Chapter 13: Electrochemistry. Electrochemistry. The study of the interchange of chemical and electrical energy.

ph: Measurement and Uses

ph Measurement and Control

To determine the equivalence points of two titrations from plots of ph versus ml of titrant added.

Electrochemistry Voltaic Cells

The Electrical Control of Chemical Reactions E3-1

Chem 1B Saddleback College Dr. White 1. Experiment 8 Titration Curve for a Monoprotic Acid

Phenolphthalein-NaOH Kinetics

Name Electrochemical Cells Practice Exam Date:

EXPERIMENT 7 Electrochemical Cells: A Discovery Exercise 1. Introduction. Discussion

Experiment 6 Titration II Acid Dissociation Constant

2. Write the chemical formula(s) of the product(s) and balance the following spontaneous reactions.

Experiment 4 (Future - Lab needs an unknown)

Solubility Product Constants

6 H2O + 6 CO 2 (g) + energy

Measurement by Ion Selective Electrodes

Determining the Identity of an Unknown Weak Acid

This value, called the ionic product of water, Kw, is related to the equilibrium constant of water

Determiniation of Flouride Ion in Well Waters of Eastwood School District, Wood, County, Ohio

User Guide Dissolved Oxygen Probes

Galvanic cell and Nernst equation

POTENTIOMETRIC TITRATION OF A WEAK ACID

PROCEDURE: Part A. Activity Series and Simple Galvanic Cells

Experiment 17: Potentiometric Titration

Discovering Electrochemical Cells

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Experiment 18: ph Measurements of Common Substances. Experiment 17: Reactions of Acids with Common Substances

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Determination of sodium with the ion-selective

1332 CHAPTER 18 Sample Questions

Chapter 1. Introduction of Electrochemical Concepts

ELECTROCHEMICAL CELLS

ELECTROCHEMICAL CELLS LAB

TITRIMETRIC ANALYSIS OF CHLORIDE

Acid Base Titration: ph Titration Curve

Acid Base Titrations

AIRMoN, ph and Conductivity Field Measurement

GA/7 Potentiometric Titration

Determining Equivalent Weight by Copper Electrolysis

Properties of Acids and Bases

Chemistry 122 Mines, Spring 2014

Redox and Electrochemistry

Neutralization Reactions. Evaluation copy

ELECTROCHEMISTRY. Theory and Practice

K + Cl - Metal M. Zinc 1.0 M M(NO

The Synthesis of trans-dichlorobis(ethylenediamine)cobalt(iii) Chloride

Name AP CHEM / / Collected Essays Chapter 17 Answers

ph Measurements of Common Substances

Experiment 6 Coffee-cup Calorimetry

Electrochemistry - ANSWERS

Chapter 10 Acid-Base titrations Problems 1, 2, 5, 7, 13, 16, 18, 21, 25

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Chemistry Laboratory Chemistry THE POTENTIOMETRIC TITRATION OF AN ACID MIXTURE 1

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

The Determination of an Equilibrium Constant

CHM1 Review Exam 12. Topics REDOX

ph and Acidity in Tomato Sauce

o Electrons are written in half reactions but not in net ionic equations. Why? Well, let s see.

Acid-Base Titrations Using ph Measurements

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

ph and Acidity in Wine and Fruit Juice

Evaluation copy. Titration of a Diprotic Acid: Identifying an Unknown. Computer

Electrochemistry. Pre-Lab Assignment. Purpose. Background. Experiment 12

5.111 Principles of Chemical Science

DISSOLVED OXYGEN PROBE

The Empirical Formula of a Compound

FAJANS DETERMINATION OF CHLORIDE

Chapter 16: Tests for ions and gases

Appendix C. Vernier Tutorial

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

ph units constitute a scale which allows scientists to determine the acid or base content of a substance or solution. The ph 0

Question Bank Electrolysis

CONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor

TITRATION CURVES, INDICATORS, AND ACID DISSOCIATION CONSTANTS

Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC

Review: Balancing Redox Reactions. Review: Balancing Redox Reactions

5.111 Principles of Chemical Science

Potentiometry: The ph Electrode and Potentiometric Titrations

Review for Solving ph Problems:

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Preliminary Concepts. Preliminary Concepts. Class 8.3 Oxidation/Reduction Reactions and Electrochemistry I. Friday, October 15 Chem 462 T.

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Useful charge on one mole of electrons: 9.64 x 10 4 coulombs/mol e - = F F is the Faraday constant

Transcription:

CHEM 311L Quantitative Analysis Laboratory Revision 2.0 A Potentiometric Analysis of Fluoride Ion in Toothpaste In this laboratory exercise, we will analyze a toothpaste sample for its Fluoride Ion (F - ) content. This analysis will be performed potentiometrically (ε; think voltage) using a Fluoride Ion selective membrane electrode (ISE). A Nernst-like relationship is expected to exist between the Fluoride Ion concentration [F - ] and the Potential of the ISE. This relationship, which must be established via calibration, will allow us to determine the desired Fluoride Ion concentration from the measured Potential of the ISE. Potentiometry involves the use of two electrodes, a Reference Electrode and an Indicator Electrode, to measure the Electric Potential (ε cell ) of an Electrochemical Cell constructed to include the Analyte Solution. A Cell Diagram for the system is: Reference Electrode Salt Bridge Analyte Solution Indicator Electrode Schematically this can be pictured as:

P a g e 2 The Cell Potential ε cell is measured using a typical Voltmeter in the limit of zero current flow. ε cell = V in the limit (I ~ 0) (Eq. 1) This limiting condition is fairly easily realized if a meter with an internal resistance of greater than 10 11 Ω is used. Modern ph meters are simply high internal resistance voltmeters meeting this requirement. Therefore, ph meters are capable of making the needed voltage measurements such that the Cell Potential can be determined. A simple example of this type of measurement involves the use of a Calomel reference electrode (Hg(l) Hg 2 Cl 2 (s) KCl(aq)) connected via a salt bridge to a cathode consisting of a Cu 2+ analyte solution and a Cu(s) indicator electrode. The oxidation reaction occurring at the Calomel reference electrode is: 2 Hg(l) + 2 Cl - (aq) Hg 2 Cl 2 (s) + 2 e - (Eq. 2) whereas the cathodic reduction is: Cu 2+ (aq) + 2 e - Cu(s) (Eq. 3) The Cu indicator electrode is a metal electrode of the first kind: an indicating electrode used to determine the concentration of an ion derived from the electrode material. Ideally, the Cell Potential is related to the Cu 2+ concentration via the Nernst Equation: ε cell = ε Cu2+ Cu o + (0.0592/2) log (1 / a Cu2+ ) - ε Calomel (Eq. 4)

P a g e 3 where a Cu2+ represents the Activity of the Cupric Ion: a Cu2+ = γ Cu2+ [Cu 2+ ] (Eq. 5) Thus, the Nernst equation forms the basis of the relationship between the analyte concentration and the measured cell potential. In our laboratory exercise we will be using a Flouride Ion Selective Membrane Double-Junction Electrode, in which the Indicator and Reference Electrodes are built into a single probe, to construct the needed electrochemical cell. (See Diagram on Next Page.) The built-in Reference is a Ag AgCl electrode which operates according to the following oxidation half-reaction: Ag(s) + Cl - (aq) AgCl(s) + e - (Eq. 6) The Indicator Electrode is constructed from another AgCl Ag electrode and a Flouride Ion Selective Membrane which is inserted into the analyte solution. The Flouride Ion (F - ) Membrane selectively binds Fluoride Ion to both its surfaces; the exterior surface being in contact with the Analyte Solution and the interior surface in contact with a reference Electrode Solution. Both the Analyte and Electrode solutions contain Fluoride Ion. However, because the Activity of the F - in the analyte solution (a a ) on the outside of the membrane is distinctly different than that in the membrane s interior solution (a e ), different concentrations of F - bind to the membrane s two surfaces. This gives rise to a Potential Difference across the membrane. In our Fluoride Ion Selective Electrode, the active membrane is a single crystal of LaF 3 doped with Europium (II) Ions to lower its electrical resistance and to facilitate ionic charge transport. F - ions bind to this crystalline surface according to: LaF 3 (s) + F - (aq) LaF 4 - (s)

P a g e 4

P a g e 5 The LaF 3 crystal, sealed into the end of a plastic tube, is in contact with the external F - analyte solution. Internal to the electrode is a solution that is 0.1M in both NaCl and NaF. The internal F - activity controls the Potential on the inner surface of the crystal. To complete the Indicator, the internal Cl - activity controls the Potential of the AgCl Ag electrode, operating reductively; in the reverse of that at the Reference. AgCl(s) + e - Ag(s) + Cl - (aq) (Eq. 7) Diagrammatically, the entire Cell (Reference, Analyte, Indicator) can be represented as: The Potential of the Cell can be written as a composite of the Potentials of the Reference and Indicator: ε cell = ε ind - ε ref + ε jnc (Eq. 8) where ε jnc is the Potential which builds at the junctions between the Cell s chambers and is the single largest source of error in most Potentiometric measurements. (Note the sign used for each contribution. This is done by convention.) The response of the Indicator Electrode to the Fluoride Ion in the analyte soltion is described by a Nernst Like equation: ε ind = L - 0.0592 log a F- (Eq. 9) where L is a constant specific to the cell in question. Inserting (Eq. 9) into (Eq. 8) and rearranging, we obtain: pf = - log a F- = (ε cell - ε jnc - ε ref L) / 0.0592 = (ε cell K) / 0.0592 (Eq. 10) where K is a Cell constant that must be determined by calibration. If interfering ions, like Hydroxide Ion (OH - ), can bind to the Indicator s membrane surface, these must also be included in the relevant activity:

P a g e 6 ε ind == L - 0.0592 log (a F- + k F-,OH- a PH- ) (Eq. 11) where k F-,OH- is the Selectivity Coefficient for the electrode toward interference by OH -. Our ISE is somewhat sensitive to Hydroxide Ion (OH - ) and this must therefore be controlled with a buffer. The recommended buffer is TISAB (Total Ionic Strength Buffer) which not only controls the OH - levels, it provides a constant Ionic Strength environment and a complexing ligand. For the LaF 3 crystal, OH - becomes a problem when its concentration becomes greater than 10% of the F - present. TISAB helps control the ph of the analyte solution so this does not occur. Additionally, the buffering action of TISAB also prevents the ph of the solution from dropping below ph = 5, where F - can protonate to form the weak acid HF (pk a = 3.17): F - (aq) + H + (aq) HF(aq) Secondly, TISAB controls the Ionic Strength of the Analyte solution. This is important because (Eq. 10) relates the cell potential ε cell to the Fluoride Ion activity a F-. However, we are most interested in the Flouride Ion concentration [F - ]. Because the activity coefficient γ F- is typically not determinable, the electrode must instead be calibrated against solutions of known concentration and not known activity. This only works if the ionic strength of the calibration standards and the analyte solution are the same. The TISAB buffer controls the ionic strengths of these solutions such that this is the case. Finally, TISAB provides Complexing Agents for possible contaminants. Aluminium Ion (Al 3+ ) and Ferric Ion (Fe 3+ ) contaminants can complex with Fluoride Ions and therefore interfere with the potentiometric measurement: Al 3+ (aq) + 4 F - (aq) AlF 4 - (aq) (Eq. 12) TISAB contains the complexing agent CDTA (trans-1,2-cyclohexanedinitrilotetraacetic acid) which combines with Al 3+ and Fe 3+ up to concentrations of 5 ppm and renders them inert. Thus, we will use a series of Standard Fluoride Ion solutions prepared using TISAB so as to generate a Calibration Curve of:

P a g e 7 ε cell vs. log [F - ] (Eq. 13) which according to (Eq. 13) should be linear. The Cell Potential will be measured using a Fluoride Ion Selective Electrode attached to a ph meter. The resulting calibration curve can then be used to determine the F - concentration in a solution prepared from a commercial toothpaste preparation.

P a g e 8 Pre-Lab Calculations 1. TISAB buffers at ph = 5.25. What is the OH - concentration in this buffer? 2. If 10 ml of the NaF Stock solution is to be diluted to prepare 100 ml a 0.01M Standard solution, what must be the concentration of the Stock solution?

P a g e 9 Procedure 1. Fluoride Ione (F - ) can adsorb onto the surface of glassware, reducing its solution concentration. This is especially problematic at low concentrations. Since we will need to work at low concentrations to determine the Fluoride Ion in our toothpaste sample, make sure all handling of the Fluoride Ion solutions is conducted using plastic labware. 2. You are provided with a 0.1M NaF stock solution in 10% TISAB. Dilute the stock solution to make standards with the following concentrations: 0.01M 0.001M 0.0001M 0.00001M All these solutions are prepared in 10% TISAB buffer. (You may want to collaborate with your neighbors on preparing these calibration solutions.) 3. You should prepare a solution of Toothpaste by dissolving 5.00g of Toothpaste in 50.00 ml of 10% TISAB buffer. Record the concentration of Fluoride Ion in the Toothpaste as reported by the manufacturer. 4. All the standards and the toothpaste sample should be at the same temperature for precise measurements. A 1 o C difference in the temperature will result in a 2% measurement error. 5. Caution: The electrode is rather expensive and fragile. Please do not drop it or knock the tip against the countertop, or with the stir bar. Also, do not rub the tip with anything, such as with a Kimwipe during drying. Scratches can damage the LaF 3 crystal. Attach the BNC connector of the Electrode to the input on the ph Meter. 6. Measure the Electrochemical Potential of each of the Sodium Fluoride standards and solutions. Try to work from the lowest to highest concentration and analyze the Toothpaste sample last. To make a measurement, place the electrode in a beaker containing the solution. Use a stir plate and stir bar to gently stir the solution. (Magnetic stirrers can generate sufficient heat to change the solution temperature. To counteract this effect, place a piece of insulating material, such as a styrofoam sheet, between the stirrer and the beaker. ) Wait for the Potential to stabilize (~1-3 minutes) and record the reading in millivolts (mv). Rinse the electrode between each measurement. 7. Using a software package such as Excel, plot ε cell vs. pf for the Standard Solutions. Here, pf is defined as: pf = - log [F - ]

P a g e 10 Add a Linear Least Squares trendline and determine the slope and intercept as well as their associated uncertainties. 8. Use your calibration curve to determine the Fluoride Ion concentration in the Toothpaste. Report this as the wt% NaF in the Toothpaste. Be sure to determine the associated uncertainty in this measurement. Compare your result with that reported by the manufacturer. Be careful here.