PROFIBUS Links & Coupler



Similar documents
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

S-series SQ Controller

MANUAL Advanced Diagnostics

S-series Mass Connection Solutions

PROCESS AUTOMATION. System Manual CREST. Fieldbus Power Hub

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

SYSTEM DESCRIPTION Termination Boards

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

PCS0100en Persy Control Services B.V. Netherlands

Modular I/O System Analog and Digital Interface Modules

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Digital input modules

Electronic overload relay EF19 and EF45

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

Power Supplies 3. SDN-P DIN Rail Series

Three-phase monitoring relay CM-PFE

Technical Information RIA14

Telephone- and leased line modem for industrial applications TD-36

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Rack mounted telephone- and leased line modem for industrial applications

Pluggable interface relays CR-P Pcb relays

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic overload relay EF65, EF96 and EF146

Inductive sensor NI10-M18-Y1X-H1141

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

MNS is Switchgear System Technical Overview

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Waveguide Access Point WGA631. Product Guide

M-series Virtual I/O Module 2

TX OPEN RS232/485 module

Redundancy Module QUINT-DIODE/40

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Permissible ambient temperature Operation Storage, transport

R60 USB to CAN interface Manual (1.5 EN)

Type testing

HARTING mcon 1000 Introduction and features

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Technical Data. Dimensions

Analog signal converters CC-E I/I Current / current isolators

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

SAFETY MANUAL SIL RELAY MODULE

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

MINI MCR-SL-R-UI(-SP)

M-series MD Plus Controller

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

M-series FOUNDATION Fieldbus I/O

Foxboro Evo Process Automation System

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

USB-to-CAN V2 compact

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

CompactLogix Power Supplies Specifications

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Solenoid Valve Island Type 3965

ABB Drives. User s Manual HTL Encoder Interface FEN-31

L5354 ControlNet Communications Interface

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

5SV Residual Current Protective Devices

Software and Display instruments

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

SAFETY MANUAL SIL Switch Amplifier

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

Quick Connect. quick - simple - efficient.

TEIP11 I/P signal converter for standard signals. Measurement made easy

3500/93 System Display

S-series DeviceNet Interface Card

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

PHOENIX CONTACT Features

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

is then retained absolutely without interruption.

Transcription:

Data Sheet DS/NDL-EN Rev. A PROFIBUS Links & Coupler Measurement made easy PROFIBUS DP/PA Segment coupler Segment coupler (compact) Motherboard for Gateways (simplex) Motherboard for Gateways (redundant) PROFIBUS DP/PA Gateway Power supply for PROFIBUS PA segments Motherboard for Power supply (simplex) Motherboard for Power supply (redundant) Power supply modules Accessories Diagnostic for PROFIBUS PA segments Diagnostic module basic Diagnostic module advanced DTM Professional

Change from two to one column Change from two to one column PROFIBUS Links & Coupler NDL300 Segment coupler (compact) 2 segments, simplex, individual modules per segment High-Power Trunk: Live work on devices in any hazardous area Connection to PROFIBUS DP Transparent, configuration free For PROFIBUS PA Optimized for size and quality, low heat dissipation Automatically adapts speed on DP - up to 12 Mbit/s The power supply consists of 1 Motherboard as mounting base and wiring interface, 2 Power Modules - 1 per segment, and 1 gateway module for connection to PROFIBUS DP. Communication is transparent between DP and PA: The gateway Segment Coupler makes each PA device appear as if it was connected to DP. This includes cyclic/acyclic data exchange and transmission speed. Segment design is clear and easy to understand without subnetworks. The PROFIBUS Power Hub Gateway Module itself is configuration-free all reducing engineering work. Availability and a long service life are achieved through: only 1 passive impedance filter per segment, optimized design for low-power dissipation, high-availability fieldbus termination, and plug-in connectors with retaining screws. 2 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

NDL300 Segment coupler (compact) Technical data Directive conformity Electromagnetic compatibility Directive 2004/108/EC EN 61326-1:2006 Supply Rated voltage 19.2... 35 V DC Rated current 1.46... 0.77 A Power loss typ. 6.7 W Fieldbus interface Number of segments 2 Rated voltage 25... 28 V Rated current 360... 10 ma Short-circuit current typ. 400 ma PROFIBUS DP Connection 9-pin Sub-D socket Protocol PROFIBUS DP/DP V1 Terminating resistor 100 Ω integrated Indicators / operating means LED ERR red flashing: overload error at output LED Seg 1...2 red 2 Hz flashing: PA error, red and LED DP/ERR red: MAU error LED PWR Power LED: green if U out > 25 V LED DP/ERR red 2 Hz flashing: DP error, red: Hardware error Electrical isolation CH/PROFIBUS DP functional insulation acc. to IEC 62103, Standard conformity Electrical isolation IEC 62103 Electromagnetic compatibility NE 21 Degree of protection IEC 60529 Fieldbus standard IEC 61158-2 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Ambient conditions Ambient temperature -40... 60 C (-40... 140 F) Storage temperature -40... 85 C (-40... 185 F) Relative humidity < 95 % non-condensing Shock resistance 15 g 11 ms Vibration resistance 1 g, 10... 150 Hz Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Housing material Polycarbonate Housing width see dimensions Housing height see dimensions Housing depth see dimensions Protection degree IP20 Mass approx. 0.9 kg Mounting DIN rail, system M36 rated insulation voltage 50 V eff PROFIBUS DP/Supply functional insulation acc. to IEC 62103, rated insulation voltage 50 V eff CH/CH functional insulation acc. to IEC 62103, rated insulation voltage 50 V eff All circuits/fe functional insulation acc. to IEC 62103, rated insulation voltage 50 V eff Fieldbus segment/supply functional insulation acc. to IEC 62103, rated insulation voltage 50 V eff PROFIBUS Links & Coupler DS/NDL-EN Rev. A 3

PROFIBUS Links & Coupler Change from two to one column NDL300 Segment coupler (compact) Mounting dimensions All dimensions in millimeters and inches (values in brackets) and without tolerance indication. 1 PROFIBUS DP/PA Gateway 2 Motherboard 3 Power supply connection d Power supply module e Ground connection clamp f PA-Trunk connection g PROFIBUS DP connection h Quick-Lok bar Electrical connections G: Gateway P: Power Supply Module Based on 199493-0007_ENG.xml / RD 2014-07-25 4 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

Change from two to one column Change from two to one column NDL300 Motherboard for Gateways (simplex) For one PROFIBUS Gateway Module Connection to PROFIBUS DP Part of Segment Coupler 3 For PROFIBUS PA The Motherboard is the mounting base and wiring interface for 1 PROFIBUS Power Hub Gateway Module. It connects to any Power Supply Motherboard via system cable (included). Communication is transparent between DP and PA: The gateway Segment Coupler makes each PA device appear as if it was connected to DP. This includes cyclic/acyclic data exchange and transmission speed. Segment design is clear and easy to understand without subnetworks. The PROFIBUS Power Hub Gateway Module itself is configuration-free all reducing engineering work. PROFIBUS Links & Coupler DS/NDL-EN Rev. A 5

PROFIBUS Links & Coupler NDL300 Motherboard for Gateways (simplex) Technical data Supply Rated voltage Rated current 19.2... 35 V SELV/PELV 2... 3 A Indicators/operating means Fault signal VFC alarm output via connectors DIP-switch address 0... 125 Directive conformity Electromagnetic compatibility Directive 2004/108/EC EN 61326-1:2013 Standard conformity Electrical isolation IEC 62103 Electromagnetic compatibility NE 21:2011 Degree of protection IEC 60529 Fieldbus standard IEC 61158-2 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 Ambient conditions Ambient temperature -40... 60 C (-40... 140 F) Storage temperature -40... 85 C (-40... 185 F) Relative humidity < 95 % non-condensing Shock resistance 15 g 11 ms Vibration resistance 1 g, 10... 150 Hz Pollution Degree max. 2, according to IEC 60664 Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Housing material Housing width Housing height Housing depth Degree of protection Mass Mounting Coating Polycarbonate 50 mm 220 mm 65 mm IP20 approx. 150 g DIN mounting rail conformal coated Data for application in connection with Ex-areas Statement of conformity Group, category, type of protection, temperature classification Directive conformity TÜV 04 ATEX 2500 X II 3 G Ex na IIC T4 Gc Directive 94/9/EC EN 60079-0:2012, EN 60079-11:2012, EN 60079-15:2010 International approvals FM approval CoC 3024816, CoC 3024816C Approved for Class I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex na IIC T4 IECEx approval IECEx TUN 13.0038X Approved for Ex na IIC T4 Gc Supplementary information Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. 6 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

Change from two to one column NDL300 Motherboard for Gateways (simplex) Mounting dimensions a Gateway, see separate data sheets b DIP-Switch for BIS address c Mounting slot for DIN rail d Motherboard e Connections for alarm voltage free contact and diagnostics bus Diagnostics link cable, optional accessory f SUB-D interface for the connection of Power Hub motherboards Electrical connections Based on 183285_ENG.xml / RD 2014-07-25 PROFIBUS Links & Coupler DS/NDL-EN Rev. A 7

Change from two to one column Change from two to one column PROFIBUS Links & Coupler NDL300 Motherboard for Gateways (redundant) For two PROFIBUS Gateway Modules Redundant configuration Connection to PROFIBUS DP For PROFIBUS PA The PROFIBUS Gateway Motherboard is a system component of the Power Hub system. The Motherboard is the mounting base and wiring interface for 2 PROFIBUS Power Hub Gateway Modules. It connects to any *.GEN Power Supply Motherboard via system cable (included). Communication is transparent between DP and PA: The gateway Segment Coupler makes each PA device appear as if it was connected to DP. This includes cyclic/acyclic data exchange and transmission speed. Segment design is clear and easy to understand without subnetworks The PROFIBUS Power Hub Gateway Module itself is configuration-free all reducing engineering work. PROFIBUS Power Hub Gateway Modules operate in redundant configuration with handshake between each communication. During redundancy transfer between modules communication is seamless for DP Master and field devices, ensuring continued plant operation. PROFIBUS Power Hub Gateways indicate their internal status via voltagefree contact and via diagnostic telegram on PROFIBUS DP. 8 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

NDL300 Motherboard for Gateways (redundant) Technical data Supply Rated voltage Rated current 19.2... 35 V SELV/PELV 2... 3 A Indicators/operating means Fault signal VFC alarm output via connectors DIP-switch address 0... 61 Directive conformity Electromagnetic compatibility Directive 2004/108/EC EN 61326-1:2013 Standard conformity Electrical isolation IEC 62103 Electromagnetic compatibility NE 21:2011 Degree of protection IEC 60529 Fieldbus standard IEC 61158-2 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 Ambient conditions Ambient temperature -40... 60 C (-40... 140 F) Storage temperature -40... 85 C (-40... 185 F) Relative humidity < 95 % non-condensing Shock resistance 15 g 11 ms Vibration resistance 1 g, 10... 150 Hz Pollution Degree max. 2, according to IEC 60664 Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Housing material Housing width Housing height Housing depth Degree of protection Mass Mounting Coating Polycarbonate 95 mm 220 mm 65 mm IP20 approx. 300 g DIN mounting rail conformal coated Data for application in connection with Ex-areas Statement of conformity Group, category, type of protection, temperature classification Directive conformity TÜV 04 ATEX 2500 X II 3 G Ex na IIC T4 Gc Directive 94/9/EC EN 60079-0:2012, EN 60079-11:2012, EN 60079-15:2010 International approvals FM approval CoC 3024816, CoC 3024816C Approved for Class I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex na IIC T4 IECEx approval IECEx TUN 13.0038X Approved for Ex na IIC T4 Gc Supplementary information Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. PROFIBUS Links & Coupler DS/NDL-EN Rev. A 9

PROFIBUS Links & Coupler Change from two to one column NDL300 Motherboard for Gateways (redundant) Mounting dimensions 1 Gateway, see separate data sheets b DIP-Switch for BIS address c Mounting slot for DIN rail d Motherboard e Connections for alarm voltage free contact and diagnostics bus Diagnostics link cable, optional accessory f SUB-D interface for the connection of Power Hub motherboards Electrical connections Based on 183286_ENG.xml / RD 2014-07-25 10 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

Change from two to one column Change from two to one column NDL300 PROFIBUS DP/PA Gateway PROFIBUS DP V1 / For 4 segments PA Connects PA transparently to PROFIBUS DP Optional redundant configuration Installation in Zone 2/Class I, Div. 2 For PROFIBUS PA Up to 12 Mbit/s, auto adapting For redundant and non-redundant masters Supports Flying Redundancy (FR) Cyclic/acyclic data exchange The fieldbus gateway is a system component of the Power Hub and plugs into the gateway motherboard. It transparently connects PROFIBUS DP with up to four PROFIBUS PA segments. It operates in conjunction with power supply modules connected to a separate motherboard. Transparent coupling means that each PA slave is directly addressed and configured from the PROFIBUS DP master. The gateway itself is configuration free. A DTM enables setup of communication and offers several status and diagnostic functionalities. Used in connection with the corresponding motherboard, two gateways provide redundant coupling. The Gateway supports PROFIBUS Flying Redundancy (FR) and all nonredundant master. PROFIBUS Links & Coupler DS/NDL-EN Rev. A 11

PROFIBUS Links & Coupler NDL300 PROFIBUS DP/PA Gateway Technical data Supply Rated voltage Rated current Power loss Fieldbus interface PROFIBUS DP Connection Protocol Indicators / operating means LED Seg 1...4 LED PWR LED DP/ERR LED Red. 19.2... 35 V DC 160... 90 ma 3 W 9-pin Sub-D socket PROFIBUS DP V1 red 2 Hz flashing: PA error, red and LED DP/ERR red: MAU error green: Power on red 2 Hz flashing: DP error, red: Hardware error yellow: redundant operation primary device, yellow 2 Hz flashing: synchronization or redundancy not available Electrical isolation CH/PROFIBUS DP functional insulation acc. to IEC 62103, rated insulation voltage 50 V rms PROFIBUS DP/Supply functional insulation acc. to IEC 62103, rated insulation voltage 50 V rms CH/CH functional insulation acc. to IEC 62103, rated insulation voltage 50 V rms All circuits/fe functional insulation acc. to IEC 62103, rated insulation voltage 50 V rms Directive conformity Electromagnetic compatibility Directive 2004/108/EC EN 61326-1:2013 Low voltage Directive 73/23/EEC EN 50178 (identical to EN 62103) Standard conformity Electrical isolation IEC 62103 Electromagnetic compatibility NE 21:2011 Degree of protection IEC 60529 Fieldbus standard IEC 61158-2 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Ambient conditions Ambient temperature -40... 60 C (-40... 140 F) Storage temperature -40... 85 C (-40... 185 F) Relative humidity < 95 % non-condensing Shock resistance 15 g 11 ms Vibration resistance 1 g, 10... 150 Hz Pollution Degree max. 2, according to IEC 60664 Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Housing material Polycarbonate Housing width 128 mm Housing height 106 mm Housing depth 40 mm Degree of protection IP20 Mass 250 g Mounting motherboard mounting Data for application in connection with Ex-areas Statement of conformity TÜV 04 ATEX 2500 X Group, category, type of II 3 G Ex na IIC T4 Gc protection, temperature classification Directive conformity Directive 94/9/EC EN 60079-0:2012, EN 60079-11:2012, EN 60079-15:2010 International approvals FM approval CoC 3024816, CoC 3024816C Approved for Class I, Div 2, Groups ABCD, T4 / Class I, Zone 2, AEx/Ex na IIC T4 IECEx approval IECEx TUN 13.0038X Approved for IECEx TUN 13.0038X Supplementary information Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. 12 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

Change from two to one column NDL300 PROFIBUS DP/PA Gateway Mounting dimensions 1 Plug connections to Motherboard b PROFIBUS DP interface c LED Seg 1... Seg 4: red flashing with 2 Hz: PA error: double slave address d LED Redundancy: yellow constant: redundancy operation primary device; yellow flashing: synchronization e LED DP/Error: red flashing with 2 Hz: DP error; red constant: hardware error f LED Power: green: Power on Electrical connections Based on 180563_ENG.xml / RD 2014-07-25 PROFIBUS Links & Coupler DS/NDL-EN Rev. A 13

Change from two to one column Change from two to one column PROFIBUS Links & Coupler NPP310 PROFIBUS PA Motherboard for Power supply (simplex) 4 segments, individual modules per segment Customizable for any host system High-Power Trunk: Live work on devices in any hazardous area Features for best signal quality, low heat dissipation Optional Advanced Diagnostics Passive impedance and CREST technology for high reliability Supports Ex ic/nl voltage limitation Installation in Zone 2/Div. 2 The modular fieldbus power supply, providing the most options for most reliable communication. It supports explosion protection e.g. the High-Power Trunk for longest cable run and highest device count. The Power Hub supports optional Advanced Diagnostics for fast fieldbus commissioning and online monitoring. The motherboard is the wiring interface and mounting plate with a DB-25 connector for PROFIBUS PA gateway or customizable cable connections to any DCS. Sockets for individual power modules enable simple installation and can be replaced without tools. Certain motherboards enable power redundancy with seamless transfer. Pairs of modules feed each segment. Availability and a long service life are achieved through: only one passive impedance filter per segment with CREST for superior signal transmission, optimized design for low power dissipation and high-availability fieldbus termination. Any mounting direction allows optimized and space-saving cabinet layout. M10964 14 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

NPP310 PROFIBUS PA Motherboard for Power supply (simplex) Technical data Supply Connection Rated voltage Rated current Fieldbus interface Number of segments Terminating resistor Indicators / operating means Fault signal Directive conformity Electromagnetic compatibility redundant 19.2... 35 V SELV/PELV 16 A 4 simplex selectable 100 Ω VFC alarm output via connectors Directive 2004/108/EC EN 61326-1:2013 Standard conformity Electrical isolation IEC 62103 Electromagnetic compatibility NE 21:2011 Degree of protection IEC 60529 Fieldbus standard IEC 61158-2 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 Ambient conditions Ambient temperature -40... 60 C (-40... 140 F) Storage temperature -40... 85 C (-40... 185 F) Relative humidity < 95 % non-condensing Shock resistance 15 g, 11 ms Vibration resistance 1 g, 10... 150 Hz Pollution Degree max. 2, according to IEC 60664 Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Connection type screw terminals Core cross-section 2.5 mm 2 Housing material Housing width Housing height Housing depth Degree of protection Protection degree Mass Mounting Coating Polycarbonate 125 mm 220 mm 65 mm IP20 approx. 850 g DIN mounting rail conformal coated Data for application in connection with Ex-areas Statement of conformity TÜV 04 ATEX 2500 X Group, category, type of II 3 G Ex na IIC T4 Gc protection, temperature classification Directive conformity Directive 94/9/EC EN 60079-0:2012, EN 60079-11:2012, EN 60079-15:2010 International approvals FM approval CoC 3024816, CoC 3024816C Approved for Class I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex na IIC T4 IECEx approval IECEx TUN 13.0038X Approved for Ex na IIC T4 Gc Supplementary information Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. PROFIBUS Links & Coupler DS/NDL-EN Rev. A 15

PROFIBUS Links & Coupler Change from two to one column NPP310 PROFIBUS PA Motherboard for Power supply (simplex) Mounting dimensions 1 Power Modules, see separate data sheets b Diagnostic Module, see separate data sheet c Connections for fieldbus trunk, terminator switch d Screening / earthing kit for trunk cables shield, optional accessory e Mounting slot for DIN rail f Motherboard g Connections for alarm voltage free contact and diagnostics bus Diagnostics link cable, optional accessory h SUB-D Host/Gateway-Interface i Connections for redundant bulk power supply Based on 180565_ENG.xml / RD 2014-07-25 16 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

Change from two to one column Change from two to one column NPP310 PROFIBUS PA Motherboard for Power supply (redundant) 4 segments, redundant, individual modules per segment Customizable for any host system High-Power Trunk: Live work on devices in any hazardous area Features for best signal quality, low heat dissipation Optional Advanced Diagnostics Passive impedance and CREST technology for high reliability Supports Ex ic/nl voltage limitation Installation in Zone 2/Div. 2 The modular fieldbus power supply, providing the most options for most reliable communication. It supports explosion protection e.g. the High-Power Trunk for longest cable run and highest device count. The Power Hub supports optional Advanced Diagnostics for fast fieldbus commissioning and online monitoring. The motherboard is the wiring interface and mounting plate with a DB-25 connector for PROFIBUS PA gateway or customizable cable connections to any DCS. Sockets for individual power modules enable simple installation and can be replaced without tools. Certain motherboards enable power redundancy with seamless transfer. Pairs of modules feed each segment. Availability and a long service life are achieved through: only one passive impedance filter per segment with CREST for superior signal transmission, optimized design for low power dissipation and high-availability fieldbus termination. Any mounting direction allows optimized and space-saving cabinet layout. M10965 PROFIBUS Links & Coupler DS/NDL-EN Rev. A 17

PROFIBUS Links & Coupler NPP310 PROFIBUS PA Motherboard for Power supply (redundant) Technical data Supply Connection Rated voltage Rated current Fieldbus interface Number of segments Terminating resistor Indicators / operating means Fault signal Directive conformity Electromagnetic compatibility redundant 19.2... 35 V SELV/PELV 16 A 4 redundant selectable 100 Ω VFC alarm output via connectors Directive 2004/108/EC EN 61326-1:2013 Mechanical specifications Connection type screw terminals Core cross-section 2.5 mm 2 Housing material Polycarbonate Housing width 221 mm Housing height 220 mm Housing depth 65 mm Degree of protection IP20 Mass approx. 1.3 kg Mounting DIN mounting rail Coating conformal coated Data for application in connection with Ex-areas Statement of conformity TÜV 04 ATEX 2500 X Group, category, type of II 3 G Ex na IIC T4 Gc protection, temperature classification Directive conformity Directive 94/9/EC EN 60079-0:2012, EN 60079-11:2012, EN 60079-15:2010 Standard conformity Electrical isolation IEC 62103 Electromagnetic compatibility NE 21:2011 Degree of protection IEC 60529 Fieldbus standard IEC 61158-2 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 Ambient conditions Ambient temperature -40... 60 C (-40... 140 F) Storage temperature -40... 85 C (-40... 185 F) Relative humidity < 95 % non-condensing Shock resistance 15 g 11 ms Vibration resistance 1 g, 10... 150 Hz Pollution Degree max. 2, according to IEC 60664 Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 International approvals FM approval CoC 3024816, CoC 3024816C Approved for Class I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex na IIC T4 IECEx approval IECEx TUN 13.0038X Approved for Ex na IIC T4 Gc Supplementary information Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. 18 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

Change from two to one column NPP310 PROFIBUS PA Motherboard for Power supply (redundant) Mounting dimensions 1 Power Modules, see separate data sheets b Diagnostic Module, see separate data sheet c Connections for Fieldbus trunk, terminator switch d Screening / earthing kit for trunk cables shield, optional accessory e Mounting slot for DIN rail f Motherboard g Connections for alarm voltage free contact and diagnostics bus Diagnostics link cable, optional accessory h SUB-D Host / Gateway-Interface i Connections for redundant bulk power supply Based on 180564_ENG.xml / RD 2014-07-25 PROFIBUS Links & Coupler DS/NDL-EN Rev. A 19

Change from two to one column PROFIBUS Links & Coupler NGP310 Power supply module (L0150) Output: 28... 30 V/500 ma High-Power Trunk for high device count and long cable runs With galvanic isolation Installation in Zone 2/Class I, Div. 2 For PROFIBUS PA and FOUNDATION fieldbus H1 High efficiency, low heat dissipation for high packing density Hot swappable in redundant configuration Module exchange without tools during operation This Power Supply Module is a system component for the Power Hub and can be plugged into the motherboard. It adapts current and voltage for the supply of fieldbus segments and field devices. This power supply features the highest output power and allows for maximum cable lengths and highest number of devices in hazardous areas with the High-Power Trunk concept. Reliability of communication is enhanced through galvanic isolation between segment and bulk power supply. Two LEDs indicate power and status. In redundant configuration two modules are connected in parallel via simple circuits ensuring seamless operation. 20 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

NGP310 Power supply module (L0150) Technical data Supply Rated voltage 19.2... 35 V DC Rated current 910... 490 ma Power loss typ. 1.8 W Fieldbus interface Rated voltage 28... 30 V Rated current 500... 10 ma Short-circuit current 550 ma Terminating impedance motherboard specific Indicators / operating means LED ERR red flashing: short-circuit or undervoltage at output LED PWR green if U out > 28 V Electrical isolation Fieldbus segment / Supply functional insulation acc. to IEC 62103, rated insulation voltage 250 V AC Directive conformity Electromagnetic compatibility Directive 2004/108/EC EN 61326-1:2013 Standard conformity Electromagnetic compatibility NE 21:2011 Degree of protection IEC 60529 Fieldbus standard IEC 61158-2 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Ambient conditions Ambient temperature -40... 70 C (-40... 158 F) Storage temperature -40... 85 C (-40... 185 F) Relative humidity < 95 % non-condensing Shock resistance 15 g 11 ms Vibration resistance 1 g, 10... 150 Hz Pollution Degree max. 2, according to IEC 60664 Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Connection type Core cross-section Housing material Housing width Housing height Housing depth Degree of protection Mass Mounting motherboard specific motherboard specific Polycarbonate 18 mm 106 mm 128 mm IP20 approx. 150 g motherboard mounting Data for application in connection with Ex-areas Outputs Voltage Uo 32 V Statement of conformity TÜV 04 ATEX 2500 X Group, category, type of II 3 G Ex na IIC T4 Gc protection, temperature classification Directive conformity Directive 94/9/EC EN 60079-0:2012, EN 60079-11:2012, EN 60079-15:2010 International approvals FM approval pending Approved for Class I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex na IIC T4 IECEx approval IECEx TUN 13.0038X Approved for Certificates and approvals Marine approval Ex na IIC T4 Gc pending Supplementary information Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. PROFIBUS Links & Coupler DS/NDL-EN Rev. A 21

PROFIBUS Links & Coupler Change from two to one column NGP310 Power supply module (L0150) Electrical connections Based on 255742_ENG.xml / RD 2014-08-07 22 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

Change from two to one column NGP310 Power supply module (L0152) Output: 25... 28 V/360 ma Universal power supply for most applications With galvanic isolation Installation in Zone 2/Class I, Div. 2 For PROFIBUS PA and FOUNDATION fieldbus H1 High efficiency, low heat dissipation for high packing density Hot swappable in redundant configuration Module exchange without tools during operation This Power Supply Module is a system component for the Power Hub and can be plugged into the motherboard. It adapts current and voltage for the supply of fieldbus segments and field devices. This power supply satisfies the needs of most fieldbus applications with regards to cable lengths and number of devices. Reliability of communication is enhanced through galvanic isolation between segment and bulk power supply. Two LEDs indicate power and status. In redundant configuration two modules are connected in parallel via simple circuits ensuring seamless operation. PROFIBUS Links & Coupler DS/NDL-EN Rev. A 23

PROFIBUS Links & Coupler NGP310 Power supply module (L0152) Technical data Supply Rated voltage 19.2... 35 V DC Rated current 670... 360 ma Power loss typ. 2 W Fieldbus interface Rated voltage 25... 28 V Rated current 360... 10 ma Short-circuit current typ. 400 ma Terminating impedance motherboard specific Indicators / operating means LED ERR red flashing: overload error at output LED PWR Power LED: green if U out > 25 V Electrical isolation Fieldbus segment / Supply functional insulation acc. to IEC 62103, rated insulation voltage 250 V eff Directive conformity Electromagnetic compatibility Directive 2004/108/EC EN 61326-1:2006 Standard conformity Electromagnetic compatibility NE 21:2006 Protection degree IEC 60529 Fieldbus standard IEC 61158-2 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Connection type Core cross-section Housing material Housing width Housing height Housing depth Protection degree Mass Mounting motherboard specific motherboard specific Polycarbonate 18 mm 106 mm 128 mm IP20 approx. 150 g motherboard mounting Data for application in connection with Ex-areas Statement of conformity TÜV 06 ATEX 553229 X Group, category, type of II 3 G Ex na II T4 protection, temperature classification Directive conformity Directive 94/9/EC EN 60079-15:2005, EN 60079-0:2004 International approvals FM approval CoC 3024816, CoC 3024816C Approved for Class I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex na IIC T4 Certificates and approvals Marine approval DNV A-10798 Supplementary information Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. Ambient conditions Ambient temperature Storage temperature Relative humidity Shock resistance Vibration resistance -40... 60 C (-40... 140 F) -40... 85 C (-40... 185 F) < 95 % non-condensing 15 g 11 ms 1 g, 10... 150 Hz 24 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

Change from two to one column NGP310 Power supply module (L0152) Electrical connections Based on 189516_ENG.xml / RD 2013-02-15 PROFIBUS Links & Coupler DS/NDL-EN Rev. A 25

Change from two to one column Change from two to one column PROFIBUS Links & Coupler NGP312 Diagnostic module basic Basic monitoring for power supply output and health Plug-in Module for the Power Hub Plug and play - no engineering required For online monitoring For FOUNDATION fieldbus-h1 and PROFIBUS PA Installation in Zone 2/Class I, Div. 2 System state and fault indication via LEDs Designed as a plug-in module for the Power Hub, the Basic Diagnostic Module provides basic system diagnostics. It checks for proper operation of bulk power supplies and monitors the connected trunks for overload or short-circuit conditions. All Power Hub modules are checked for proper function. On redundant power modules it indicates missmatching pairs. The module indicates a fault condition via voltage-free contact. It provides monitoring "plug-and-play" without additional engineering. LED signals indicate a fault for easy detection. 26 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

NGP312 Diagnostic module basic Technical data Supply Rated voltage 19.2... 35 V Rated current 20 ma Power loss max. 0.5 W Indicators / operating means LED PRI PWR green: on, primary bulk power supply connected LED SEC PWR green: on, secondary bulk power supply connected LED ERR red: 2 Hz flashing, power supply fault (short-circuit, undervoltage), redundancy fault Fault signal VFC alarm 1 A, 50 V DC, normally closed Mechanical specifications Connection type motherboard specific Core cross-section motherboard specific Housing material Polycarbonate Housing width 18 mm Housing height 106 mm Housing depth 128 mm Degree of protection IP20 Mass approx. 70 g Mounting motherboard mounting Data for application in connection with Ex-areas Statement of conformity TÜV 04 ATEX 2500 X Group, category, type of II 3 G Ex na nc IIC T4 Gc protection, temperature classification Directive conformity Directive 94/9/EC EN 60079-0:2012, EN 60079-11:2012, EN 60079-15:2010 Electrical isolation Fieldbus segment / Fieldbus segment functional insulation acc. to IEC 62103, rated insulation voltage 50 V eff Directive conformity Electromagnetic compatibility Directive 2004/108/EC EN 61326-1:2013 Standard conformity Electromagnetic compatibility NE 21:2011 Degree of protection IEC 60529 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Ambient conditions Ambient temperature -40... 70 C (-40... 158 F) Storage temperature -40... 85 C (-40... 185 F) Relative humidity < 95 % non-condensing Shock resistance 15 g 11 ms Vibration resistance 1 g, 10... 150 Hz Pollution Degree max. 2, according to IEC 60664 Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 International approvals FM approval CoC 3024816, CoC 3024816C Approved for Class I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex nc IIC T4 IECEx approval IECEx TUN 13.0038X Approved for Ex na nc IIC T4 Gc Certificates and approvals Marine approval DNV A-10798 Supplementary information Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. PROFIBUS Links & Coupler DS/NDL-EN Rev. A 27

PROFIBUS Links & Coupler Change from two to one column NGP312 Diagnostic module basic Mounting dimensions Dimensions Diagnostics Module 1 Power Supply Modules, see separate data sheets b Diagnostics Module c Connections for fieldbus trunk, terminator switch d Screening / earthing kit for trunk cables shield, optional accessory e Mounting slot for DIN rail f Motherboard, see separate data sheets g Connections for alarm, voltage free contact and diagnostics bus h Connections for redundant host i Connections for redundant bulk power supply j Plug connections to Motherboard k State and fault indication LEDs Dimensions complete redundant system Electrical connections Based on 131001_ENG.xml / RD 2014-08-05 28 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

Change from two to one column Change from two to one column NGP312 Diagnostic module advanced Comprehensive diagnostics for fieldbus physical layer and power supply Plug-in Module for the Power Hub Precise measurements through passive circuits For commissioning, online monitoring and troubleshooting For FOUNDATION fieldbus-h1 and PROFIBUS PA Installation in Zone 2/Class I, Div. 2 System state and fault indication via LEDs Display of data in the safety of the control room Automatic setup of diagnostic system Full software integration into DCS and PAM possible Designed as a plug-in module for the Power Hub, this Advanced Diagnostic Module (ADM) is a comprehensive measurement tool for the physical layer of up to four fieldbus segments. It's passive input circuits leave the physical layer untouched for exact data. The ADM detects gradual or sudden changes and helps trace even intermittent malfunctions. The ADM supports commissioning, online monitoring and troubleshooting. It can be integrated tightly into the DCS and PAM via a separate diagnostic bus, making the fieldbus physical layer itself a managable asset. Configuration tools automate setup of the ADM and of selected DCS. The Diagnostic Manager is the software for display and operation from the safety of the control room. The Professional Edition provides powerful functions and wizards simplifying and automating work procedures: Embedded expert system data historian and a built-in oscilloscope are included. M10967 PROFIBUS Links & Coupler DS/NDL-EN Rev. A 29

PROFIBUS Links & Coupler NGP312 Diagnostic module advanced Technical data Supply Rated voltage 19.2... 35 V Rated current 110... 30 ma Power loss max. 2 W Fieldbus interface Number of segments 4 Fieldbus type FOUNDATION fieldbus-h1 / PROFIBUS PA Rated voltage 9... 32 V Indicators / operating means LED PRI PWR green: on, primary bulk power supply connected LED SEC PWR green: on, secondary bulk power supply connected LED Seg 1...4 yellow: bus activity; red 2 Hz flashing: alarm; red: hardware error Fault signal VFC alarm 1 A, 50 V DC, normally closed DIP-switch diagnostic address 1...247, binary coded Interface Interface type diagnostic bus: RS 485 Ambient conditions Ambient temperature -40... 70 C (-40... 158 F) Storage temperature -40... 85 C (-40... 185 F) Relative humidity < 95 % non-condensing Shock resistance 15 g 11 ms Vibration resistance 1 g, 10... 150 Hz Pollution Degree max. 2, according to IEC 60664 Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Connection type motherboard specific Core cross-section motherboard specific Housing material Polycarbonate Housing width 18 mm Housing height 106 mm Housing depth 128 mm Degree of protection IP20 Mass approx. 100 g Mounting motherboard mounting Mating cycles 100 Data for application in connection with Ex-areas Statement of conformity TÜV 04 ATEX 2500 X Group, category, type of II 3 G Ex na IIC T4 Gc protection, temperature classification Directive conformity Directive 94/9/EC EN 60079-0:2012, EN 60079-11:2012, EN 60079-15:2010 Electrical isolation Fieldbus segment / Fieldbus functional insulation acc. to IEC 62103, segment rated insulation voltage 50 V eff Fieldbus segment / Supply functional insulation acc. to IEC 62103, rated insulation voltage 50 V eff Directive conformity Electromagnetic compatibility Directive 2004/108/EC EN 61326-1:2013 Standard conformity Electromagnetic compatibility NE 21:2011 Degree of protection IEC 60529 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 International approvals FM approval CoC 3024816, CoC 3024816C Approved for Class I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex na IIC T4 IECEx approval IECEx TUN 13.0038X Approved for Ex na IIC T4 Gc Certificates and approvals Marine approval DNV A-10798 Supplementary information Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. 30 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

Change from two to one column NGP312 Diagnostic module advanced Dimensions Advanced Diagnostic Module* Dimensions complete redundant system* *all dimensions without tolerance indication 1 Power Supply Modules, see separate data sheets b Advanced Diagnostic Module c Connections for fieldbus trunk, terminator switch d Screening / earthing kit for trunk cables shield, optional accessory e Mounting slot for DIN rail f Motherboard, see separate data sheets g Connections for alarm, voltage free contact and diagnostics bus h Connections for redundant host i Connections for redundant bulk power supply j Plug connections to Motherboard k LED Seg 1... Seg 4 l LED green SEC Power m LED green PRI Power n Dip-Switch-Array for diagnostic address or address on the diagnostics bus o Address selection overview PROFIBUS Links & Coupler DS/NDL-EN Rev. A 31

PROFIBUS Links & Coupler NGP312 Diagnostic module advanced Electrical connections Installation note 32 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

NGP312 Diagnostic module advanced Accessories Software User Interface for monitoring up to or including 100 fieldbus segments: Diagnostic Manager, Professional Edition Software User Interface for monitoring more than 100 fieldbus segments: Diagnostic Manager, Professional Edition Diagnostic Gateway Functional overview Expert system Built-in expert system interprets behavior of each segment based on rules and gives pointed information in clear text. Precisely diagnosis causes and suggests remedies, which are easy to understand. Supply input voltage The supply voltage of the primary and secondary input is measured in a range of 0 V... 40 V. Segment power redundancy integrity The health of the primary and backup fieldbus power supply is monitored. Mismatch of redundancy pairs is detected and causes an alarm. Fieldbus voltage The segment voltage is measured in a range of 0 V... 35 V. Fieldbus current The current feed into a fieldbus segment is measured in a range of 0 A... 1 A depending on the used power supply. Unbalance detection A capacitive or resistive short between any fieldbus wire and shield is measured and given in a range between -100 %... +100 %. (-100% = short against - wire, +100 % = short against +wire) Termination Over- and Undertermination are detected and reported. Signal level Node specific signal levels are measured in a range of 0 V... 2.5 V. Jitter Jitter is a measurement for the timing of each bit. Each component connected (power supply, field instrument, cable,...) to the segment influences jitter. It is an excellent indicator for segment health. The jitter is either segment- or device-specifically measured in a range of 0 μsec... 8 μsec. Signal polarity For each node the polarity of the signal modulation is given. Noise measurement Noise is measured in a frequency range between 100 Hz... 140 khz. Noise measurement is node-addressspecific in order to detect device-specific noise. Communication errors statistics Segment-specific error counters, e. g. for CRC errors, framing errors. Oscilloscope function The built-in oscilloscope is a powerful tool for signal voltage behavior analysis. It allows for analysis of specific frames and occurring communication errors. Trigger conditions, as e. g. different frame types, CRC errors, framing errors are either node-address-specific or unspecific. The frame contents detected in the sampled period are analyzed and shown. Live list generation A list of all connected devices and additional status information is generated. The ADM detects initial connection of a device to a segment in operation. A message reminds the user to re-run the commissioning wizard. Alarm management For all measured values, either segment- or node-specific, alarm limits exist. In addition, warning limits can be defined. When these limits are violated, alarms are generated. History / trending function For up to 2 years, segment- and node-specific physical layer values can be stored and time stamped in the Diagnostic Module, so trending analyses are possible over longer periods of time. Based on 131000_ENG.xml / RD 2014-08-05 PROFIBUS Links & Coupler DS/NDL-EN Rev. A 33

Change from two to one column PROFIBUS Links & Coupler NGP312 DTM Professional Software user interface for Advanced Diagnostic Modules Simultaneous access to all ADM of a plant Embedded expert system gives pointed advice in clear text Includes Commissioning Wizard, data historian, oscilloscope... For FOUNDATION fieldbus H1 and PROFIBUS PA Automatic setup of diagnostic system The Diagnostic Manager displays measurements of Advanced Diagnostic Modules (ADM). It commissions and configures the ADMs and receives data and alarms in realtime. An Expert System learns values and characteristics of each segment and translates them into concise descriptions of causes in clear text. Maintenance or repair work can be scheduled proactively while the plant still operates. The Diagnostic Manager and ADM ensure best possible quality of the physical layer, higher plant availability and reduced troubleshooting effort. 34 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

NGP312 DTM Professional Technical data Software Hardware PC with 1 GHz processor and at least 512 MByte requirements RAM Operating Windows 7, VISTA and XP, each with system.net framework 1.1 and PACTware TM 3.6 /4.0 Languages English Licensing New plant licenses: DTM-FC-AD for production process plants with up to 100 segments DTM-FC-AD.1 for more than 100 segments Upgrade licenses: DTM-FC-AD.UPG upgrade of existing DTMFC-AD DTM-FC-AD.1.UPG upgrade of existing DTM-FC-AD.1 Expert System Built-in expert system interprets behavior of each segment based on rules and gives pointed information in clear text. Precisely diagnosis causes and suggests remedies, which are easy to understand. Physical Layer Bulk power health, segment voltage and current, Diagnostics unbalance, noise, signal level, signal polarity, jitter Software Commissioning Wizard Snapshot Explorer History Data Export Segment Focus Mode Integrated oscilloscope OPC Server Interface Remote diagnostics Generates reports on physical layer and communications data per device or segment. Automates repetitive tasks during commissioning. User interface to review the history of Physical Layer Measurement Reports stored. Export of long-term history data to Excel and the file formats comma-separated (CSV) or binary for graphic analysis and diagram creation Fast update of detailed measurements for a single segment Displays fieldbus signals in waveform giving greatest detail. To aid troubleshooting activities, even seldom occuring events can be captured using the oscilloscope's many selectable trigger functions. The open OPC server interface can easily be adapted to any OPC client. It provides as a Data Access Server (Version 2.05) Summarized State information and basic diagnostic data such as the operating status of the diagnostic module and of the segments. Fieldbus experts and maintenance contractors are enabled to review Physical Layer diagnostics from offsite. Change from two to one column Electrical connections Based on T33373_ENG.xml / RD 2010-08-09 PROFIBUS Links & Coupler DS/NDL-EN Rev. A 35

PROFIBUS Links & Coupler Ordering Information DP / PA Segment coupler NDL300 Segment Coupler (compact) IP 20, comprises the following components: 1x Motherboard compact, DIN rail, system M36 1x PROFIBUS DP / PA gateway, DP bus up to 12 Mbit/s, transparent 2x Power supply modules, PA bus fixed at 31.25 kbit/s, PA power feed: U S = 25... 28 V DC, I S 360 ma, incl. fixed bus termination Order number (199493-0007) 3KXN635300L0001 Motherboard for Gateways (simplex) For 1x DP / PA gateway modules, DIN top-hat rail, IP 20, II 3G Ex na IIC T4 Gc, Zone 2/Class I, Div. 2. Includes SUB-D cable, 25-pin, for connecting the motherboards Includes DIP switch for address assignment (optional for diagnostic transmission) (183285) 3KXN635300L0110 Motherboard for Gateways (redundant) For 2x DP / PA gateway modules (redundant), DIN top-hat rail, IP 20, II 3G Ex na IIC T4 Gc, Zone 2/Class I, Div. 2. Includes SUB-D cable, 25-pin, for connecting the motherboards Includes DIP switch for address assignment (optional for diagnostic transmission) (183286) 3KXN635300L0120 PROFIBUS DP/PA Gateway DP bus up to 12 Mbit/s, transparent, for 4x power supply modules, IP 20, II 3G Ex na IIC T4 Gc, Zone 2/Class I, Div. 2. (180563) 3KXN635300L0150 Power supply for PA segments NPP310 PROFIBUS PA Motherboard for power supply (simplex) For 4 power supply modules and for 1x diagnostic module, 4x switchable PA bus terminators, DIN top-hat rail, IP 20, II 3G Ex na IIC T4 Gc, Zone 2/Class I, Div. 2. (180565) 3KXN636310L0110 PROFIBUS PA Motherboard for Power supply (redundant) For 2x4 power supply modules (redundant) and for 1x diagnostic module, 4x switchable PA bus terminators, DIN top-hat rail, IP 20, II 3G Ex na IIC T4 Gc, Zone 2/Class I, Div. 2. (180564) 3KXN636310L0120 NGP310 PROFIBUS PA / FOUNDATION Fieldbus-H1 Grounding connection set for motherboards For large-surface connection of the trunk cable shields. (133733) 3KXN617310L0100 Power supply module PA / H1 bus fixed at 31.25 kbit/s, IP 20, IP 20, II 3 G Ex na IIC T4 Gc, Zone 2/Class I, Div. 2. PA / H1 power feed: U S = 28...30 V DC, I S 500 ma, elec. isolation. (255742) 3KXN617310L0150 Power supply module PA / H1 bus fixed at 31.25 kbit/s, IP 20, II 3G Ex na II T4, Zone 2/Class I, Div. 2. PA / H1 power feed: U S = 25...28 V DC, I S 360 ma, elec. isolation. (189516) 3KXN617310L0152 36 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

Diagnostic for PA segments NGP312 PROFIBUS PA / FOUNDATION Fieldbus-H1 Diagnostic module basic For supply & PA / H1 bus, IP 20, Zone 2/Class I, Div. 2., II 3G Ex na nc IIC T4 Gc Check power sources, power supply modules, and PA / H1 for overload and short circuit, etc. Messages only transmitted by means of relay contact. Order number (131001) 3KXN617312L0160 Diagnostic module advanced For supply & PA / H1 bus, IP 20, Zone 2/Class I, Div. 2., II 3G Ex na IIC T4 Gc Check power sources, power supply modules, and PA / H1 for overload and short circuit, etc. Physical layer checks. Diagnostic DTM Professional is required (& Diagnostic gateway module for H1 lines) ATTENTION: Check first the release of the DTMs for your frame application! (131000) 3KXN617312L0161 DTM Professional for the diagnostic module advanced 100 segments, for Windows 7, Vista and XP (32/64-bit versions), dialog in English Free-of-charge Gateway DTM is required ATTENTION: Check first the release of the DTMs for your frame application! (192767) 3KXN617312L0170 DTM Professional for the diagnostic module advanced > 100 segments, for Windows 7, Vista and XP (32/64-bit versions), dialog in English Free-of-charge Gateway DTM is required ATTENTION: Check first the release of the DTMs for your frame application! (192911) 3KXN617312L0171 PROFIBUS Links & Coupler DS/NDL-EN Rev. A 37

Notes Notes 38 DS/NDL-EN Rev. A PROFIBUS Links & Coupler

Notes Notes PROFIBUS Links & Coupler DS/NDL-EN Rev. A 39

Contact us ABB Automation GmbH Service Instrumentation Kallstadter Straße 1 68309 Mannheim Germany Customer service center: +49 180 5 222 580 * E-Mail: automation.service@de.abb.com www.abb.com/measurement * 14 cents/minute from German landlines, Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts is forbidden without prior written consent of ABB. DS/NDL-EN Rev. A 01.2015 max. 42 cents/minute from mobiles. Copyright 2015 ABB All rights reserved 3KXN635000R1001 Sales Service