Data Sheet SS/MAG/WW Issue 2 Electromagnetic Flowmeter MagMaster Water & Waste Water Version Industry-specific design suitable for all applications found in the water and waste water industries Widest flow range, highest accuracy diameters from 5mm to 22mm (.5 to 84 in.) Submersible sensor suitable for flooded chambers and pits Buriable sensor eliminates chambers and ensures fast, low-cost installation Hazardous area approvals FM, CSA, ATEX ideal for waste water treatment works Built-in earthing (grounding) electrode eliminates the need for earthing (grounding) flanges 2-year warranty as standard high-quality product guarantees reliable maintenance-free operation CalMaster compatible in situ verification of flow meter calibration Remote communications including Profibus DP v MagMaster bringing unsurpassed flowmetering performance to the Water and Waste Water industries
Setting the Standard Designed specifically to target the diverse applications found in the supply and treatment of both potable and waste water, MagMaster sets new levels of accuracy, reliability and low cost of ownership. MagMaster's ground-breaking design guarantees long-term calibration stability, coupled with the wide range of sizes, 5 to 26mm (.5 to 2 in.), choice of lining and electrode material quickly established MagMaster as the de facto industry standard electromagnetic flow meter. Calibration Verification CalMaster is the world's first in situ calibration verification system. The system allows the calibration of MagMaster electromagnetic flow meters to be verified without the need for 'wet calibration'. The complex series of tests automatically performed by CalMaster is completed and a certificate produced without costly excavation of the sensor or disruption to the water supply. A complete solution to the regulatory requirement for routine verification and traceability of electromagnetic flow meters. Class-leading Flow Performance The combination of sensors with ultra-linear magnetics, proven technology, signal processing and sensor drive results in unsurpassed accuracy and an operable flow range of 5:. MagMaster's class-leading performance ensures reliable and accurate measurement over the widely varying flow rates, including minimal night flows, which occur in typical water and waste water systems. Assured Quality MagMaster is designed and manufactured in accordance with international quality procedures (ISO 9) and all flowmeters are calibrated on nationally-traceable calibration rigs to provide the end user with complete assurance of both quality and performance of the meter. For further information on CalMaster refer to the brochure PB/CALMASTER ABB operated national and internationally accredited flow calibration facilities in the UK, USA, Australia, Germany and India. 2
Electronic Display Unit Comprehensive display Forward, reverse and net totals 4 digital outputs: forward pulse, reverse pulse, alarm and alarm 2 2 analog outputs (output 2 optional) Communications: serial data (RS232), HART and Profibus DP v MagMaster is available with integral or remote transmitters, configuration is achieved either with a configurator of via the optional integral keypad. The software features multi-level password protection to prevent unauthorized configuration changes. In the 2-line display only variant, display data can only be changed using a magnetic wand, no operational parameters can be changed without the use of a configurator and appropriate passwords. Wallmount Version 2-Line Display Version 32-Character Super-Twist Display Keypad Version >43567 Ltr 2.328Ltr/s Forward flow total Reverse flow total Net flow total Alarms Flow Velocity in m/s or ft/s Flow Rate % of Range 2.328 Ltr/s >43567Ltr Alarm/Flowrate units Flow rate Magnetic switches for totalizer reset & to scroll through all parameters Membrane keys for access, adjustment of all parameters, totalizer reset and to scroll through all parameters Programming Options Local hand-held configurator (for example Psion Workabout) Integral keypad HART Personal computer 3
Easy, Low-cost Installation MagMaster sensors' rugged and robust construction ensure a long, maintenance-free life under the arduous conditions experienced in the water and waste water industry. The sensors are fully submersible, meeting the requirements of IP68 (NEMA6P) enabling installation in flooded chambers or metering pits. MagMaster sensors in all sizes are buriable. Installation merely involves excavating to the underground pipe, fitting the sensor, cabling back to the transmitter and then backfilling the hole. No metering chambers or pits are required so the installation is simple, fast and low cost. International Approvals Alternative versions of MagMaster are available for general locations with FM Approval and for Hazardous Area locations to ATEX, FM and CSA Standards. A brief summary of these Hazardous Area versions is given below, covering the safety designation inside the pipe. No external safety barriers are required. Underground Installation of MagMaster SENSOR INSIDE PIPE TRANSMITTER LOCATION FM & CSA HAZARDOUS AREA APPROVAL CLASS, DIV. 2, GROUPS A B C D FM APPROVED CSA CERTIFIED INTRINSICALLY SAFE ELECTRODES REMOTE ONLY IN HAZARDOUS AREA REMOTE ONLY IN HAZARDOUS AREA CSA CERTIFIED NON INCENDIVE INTEGRAL AND REMOTE IN HAZARDOUS AREA ATEX II 2 (i) G EEx e m ia IIC T4 ZONE ZONE REMOTE TRANSMITTER IN SAFE AREA 4
Specification Sensor Sizes Sizes mm (in.) Flow Range Minimum Maximum* m 3 /h (US g/min) m 3 /h (US g/min) Accuracy (under forward flow reference conditions) 5. 4. 5 (.6).5 (.2) 6 (28) 2 (.8).9 (.38) (5) 25 ().4 (.59) 7 (77) 4 (.6).35 (.5) 45 (97) 5 (2).53 (.23) 7 (3) 65 (2.5).89 (.4) 9 (525) 8 (3).36 (.59) 8 (796) (4).2 (.94) 283 (243) 5 (6).47 (2.) 64 (2797) 2 (8).84 (3.73) 3 (4974) 25 ().32 (5.83) 77 (777) 3 (2).9 (8.4) 254 (9) 35 (4) 2.6 () 346 (523) 4 (6) 3.39 (5) 452 (989) Accuracy % 3. 2...2.5..2.3.4.5 Velocity m/s (ft/s) Sizes > 7mm (27 in.) ±mm/s (.33ft/s) for velocities below.5m/s (.64ft/s) Sizes < 6mm (24 in.) ±.75mm/s (.25ft/s) for velocities below.5m/s (.64ft/s). 5. Analog output Additional < ±.8mA Temperature effect Transmitter <±.8% of reading/ C Analog output Additional <±.8% of reading/ C Power supply variation Negligible Pressure effect <.5% over the operating range of the equipment 45 (8) 4.29 (9) 573 (258) 5 (2) 5.3 (23) 77 (39) 6 (24) 7.6 (33) 8 (4476) 7 (28) 4 (46) 385 (692) 76 (3) 6 (52) 59 (6993) 8 (3) 8 (6) 8 (7956) 9 (35) 23 (75) 229 (7) (39) 28 (93) 283 (243) 5 (4) 3 (2) 342 (54) 2 (47) 4 (34) 47 (79) 4 (55) 55 (82) 554 (2437) 5 (59) 64 (28) 636 (2797) 6 (63) 72 (238) 724 (383) 8 (7) 92 (32) 96 (428) 2 (79) 3 (372) 3 (4974) 22 (87) 36 (45) 37 (62) * Based on ms (33fts ), but instrument capability in excess of 5ms (5fts ) 5
Wetted Material Lining Suitable for potable water and waste water (all materials UKWFBS listed and compliant to WRC Water Bye-laws Scheme BS 692) Contact factory for non-standard materials Electrodes Stainless steel 36 Contact factory for non-standard materials Flanges Carbon steel Pressure limitations 6mm as flange rating 7mm 6, or 6 bar Environmental protection IP68 (NEMA6P) Buriable to 5m (6 ft) depth Pressure equipment directive 97/23/EC This product is applicable in networks for the supply, distribution and discharge of water and associated equipment and is therefore exempt. Conductivity 5µS/cm End connections PN6 ANSI B6.5 Class 5 PN ANSI/AWWA C27 Class B and D PN6 AS229 Table C or BS/AS229 Table D and E Electronic Display Unit Mounting Integral with sensor OR Remote up to m (325 ft) Longer lengths available on request Housing IP65 (NEMA4) Glass-loaded polypropylene, polycarbonate window ULVO rated Electrical connections 2mm glands, or accepts /2 in. NPT connections Sensor cable ABB cable supplied as standard Armored version available on request Power supply* Voltage Type Voltage Range (V) Absolute rating Liquid Sensing Drives output to zero with an empty pipe Frequency (Hz) AC 85 to 265 47 to 44 <2 DC to 4 <2 *Power supply fully isolated VA Languages Operation in English, French, German, Spanish, Italian, Dutch plus others on application Temperature Ranges Process Ambient Storage 7ºC (58ºF) 6ºC (4ºF) 75ºC (67ºC) ºC (4ºF) 2ºC ( 4ºF) 2ºC ( 4ºF) 6
Output/Inputs Common ma Forward Reverse <2mA, 6V <8Hz, <35V open collector square wave, or fixed pulse width <2.5s, 25mA Mounting 45 maximum Choice of 9 alarms <35V, >25mA open collector Totalizer reset Dual range selection Output hold Drive to zero RS232 (local only) Optional (For blind & 2-line display units) Dual ma Profibus DP v Contact closure or logic input 9-pin D-connector (PC compatible) Dual analog (optional) Non-active output is 4mA or ma Pipe Connections Sensor Electrodes >5 x pipe dia. >2 x pipe dia. minimum minimum HART Optional (For keypad units) Flow Direction Dual ma Dual analog Non-active output is 4mA or ma Galvanic isolation to 5V DC between analog pulse/alarm and earth/ground 7
Sensor Specification (nominal dimensions) 5 to 22mm (.5 to 84 in.) Meter Size mm Flange Size Metric Flanges (DN) BS Flanges (in.) AWWA C27 Flanges (NPS) Length A mm (in.) Approximate Weight kg (lb) 5 5 /2 /2 2 2 3 /4 25 25 4 4 /2 /2 2 (7.9)* 9 (2) 5 5 2 2 (23) 65 65 2 /2 2 /2 8 (4) 8 8 3 3 8 (4) 4 4 25 (9.8)* 24 (54) 5 5 6 6 3 (.8)* 38 (84) 2 2 8 8 35 (3.8)** 55 (2) 25 25 45 (7.7)** 88 (94) 3 3 2 2 5 (9.7)** 28 (282) 35 35 4 4 55 (2.7)** (22) 4 4 6 6 6 (23.6)** 5 (253) 45 45 8 8 698 (27.5)** 6 (352) 5 5 2 2 768 (3.2)** 27 (455) 6 6 24 24 98 (36.)** 35 (693) 7 7 27 28 7 (27.6)*** 76 76 3 3 762 (3)*** 43 (945) 8 8 8 (3.5)*** 9 9 36 36 9 (35.4)*** 54 (9) 39 39 (39.4)*** 72 (585) 5 5 42 42 67 (42)*** 88 (93) 2 2 48 48 2 (47.2)*** (26) 4 4 54 54 4 (55.)*** 45 (39) 5 5 6 6 524 (59)*** 37 (3) 6 6 66 66 6 (63)*** 2 (44) 8 8 72 72 225 (88.6)*** 24 (528) 2 2 78 78 25 (98.4)*** 32 (74) 22 22 84 84 275 ()*** 42 (93) *Typical tolerance +/ 3mm **Typical tolerance +/ 5mm ***Typical tolerance +/ mm 3 /4 7 (5) A 8
Overall Dimensions Terminal Box Sensor Mounted Dimensions in mm (in.) 95 (3.75) 8 (3.5) M2 Cable Gland shown 6 (2.4) 3 (.2) IP65/NEMA4 Remote Electronic Display Unit Dimensions in mm (in.) 6.5 (6.36) ø6.5 (.25) (3 POSN) 24 (8.43) 232 (9.3) 29 (.4) 34.5 34.5 34.5 = 69 = = (2.72) = Unit Depth = 7 (2.75) 34.5mm =.36 in 9
Integral Electronic Display Unit (mounted on Sensor) Dimensions in mm (in.) 242.5 (9.55) 24 (8.43) 29 (.4) 34.5 (.36) 34.5 (.36) 6.5 (6.36) 33.5 (.32) Unit Depth = 7 (2.75)
Electrical Connections Supply Fuse N ( ) L (+) BLK3 TRANSMITTER PULSE/ ALARMS INPUT ALARM FOUTA / FWD ALARM2 FOUTB / REV PLSV PLSV EXTI/P+ EXTI/P 22R 22R 5V SENSOR CONNECTIONS CD IC2 /DUAL I IC+ CD IC CD2 BLK2 HART CD2 SIGGND BLK SIGGND DS DS SIG SIG Optional SIG2 SIG2 ESCRN DS2 * *ABB cable DS2 Note: Remove any exposed black conductive layer from the inner insulation of both coaxial cables.
Ordering Information Sensor Ordering Code MF XXXX X X X X X XX X XX Calibrated Bore No sensor (Transmitter only) 5mm ( /2 in.) 2mm ( 3 /4 in.) 25mm ( in.) 4mm ( /2 in.) 5mm (2 in.) 65mm (2 /2 in.) 8mm (3 in.) mm (4 in.) 5mm (6 in.) 2mm (8 in.) 25mm ( in.) 3mm (2 in.) 35mm (4 in.) 4mm (6 in.) 45mm (8 in.) 5mm (2 in.) 6mm (24 in.) 7mm (28 in.) 76mm (3 in.) 8mm (3 in.) 9mm (35 in.) mm (39 in.) 5mm (4 in.) 2mm (47 in.) 4mm (55 in.) 5mm (59 in.) 6mm (63 in.) 8mm (7 in.) 2mm (79 in.) 22mm (87 in.) 24mm (94 in.) apply to Sales Office E E5 E2 E25 E4 E5 E65 F8 F F5 F2 F25 F3 F35 F4 F45 F5 F6 F7 F76 F8 F9 F2 F2 F22 F42 F52 F62 E82 E22 E222 End Connections Flanged None (Transmitter only) PN6, fully rated PN6, bar rated 7mm to 22mm PN6, 6 bar rated 7mm to 22mm PN, fully rated PN6, fully rated 7mm to 22mm ANSI B 6.5 class 5, fully rated 24 in. ANSI/AWWA C27 class B fully rated 27 in. to 66 in. ANSI/AWWA C27 class D fully rated 27 in. to 66 in. AS229 Table C fully rated 24 in. AS229 Table D fully rated 66 in. BS/AS229 Table E, fully rated 48 in. BS Table D fully rated 66 in. AS487 Class 6 C B 5 8 3 U V F L 7 K Z 2
Sensor Ordering Code MF XXXX X X X X X XX X XX Lining Material None (Transmitter only) Elastomer suitable for potable water and waste water WRAS (UK) Listed Elastomer suitable for potable water and waste water ACS (France) Approved Others on application 4 F Electrodes None (Transmitter only) 36 Stainless Steel (suitable for water and waste water) Others on application Sensor Build Standard Transmitter only General FM GENERAL 8 Calibration Transmitter only Standard 3-point, with pressure test 8-point, with pressure test UKAS, with pressure test Standard 3-point, no pressure test 8-point, no pressure test UKAS, no pressure test Standard 3-point; CalMaster Fingerprint & disk; No pressure test Standard 3-point; CalMaster Fingerprint & disk; With pressure test 2 5 A B D I J Cable Length User-specified length in m increments (9m max.) (Must be '' for glanding digit 4) XX Glanding None (Transmitter only) 2mm plastic gland (sensor cable fitted and potted) Conduit entry: /2 in. NPT (Blanked) all North American versions (cable length to be '') 2mm plastic. Cable not fitted. 2mm armor. Cable not fitted. 4 5 7 Transmitter Sensor-mounted MagMaster Transmitter, 4mm (6 in.) only Remote MagMaster Transmitter EH ER 3
Transmitter Ordering Code X X X X X X X Power Supply None - Sensor only 95V to 24V AC nominal, 47 to 44Hz V to 4V DC (Max) 3 Display None (or sensor only) 2-Line Display 3-Line Display with keypad (no HART) 3 4 Output Options Standard outputs (or sensor only) Dual current output HART communications Profibus DP v 2 8 Transmitter Build Standard Transmitter only General FM GENERAL 3 Display Orientation None (or sensor only) Standard Other please enquire Language None (or sensor only) English French German Spanish Italian Dutch 2 3 4 5 6 Labelling Factory allocated (internal only) X 4
5
MagMaster Water & Waste Water Version ABB has Sales & Customer Support expertise in over countries worldwide www.abb.com The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in UK (4.9) ABB 29 SS/MAG/WW Issue 2 ABB Limited Oldends Lane, Stonehouse Gloucestershire GL 3TA UK Tel: +44 ()453 82666 Fax: +44 ()453 82967 ABB Inc. 25 E. County Line Road Warminster PA 8974 USA Tel: + 25 674 6 Fax: + 25 674 783