Bluelab Soil ph Meter Instruction Manual



Similar documents
Care and use guide. soil ph meter. Contents. page

Care and use guide. Contents. page

Care and use guide. Contents. a handy solution made easy. page

Care and use guide. Contents. a handy solution made easy. page

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

ExStik TM ph Waterproof Meters

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Instruction Manual Temp 4/5/6 Temperature Meter Series

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

el-720 Carbon Dioxide Gas Leak Detector User s Guide

For all turfgrass areas. Now you can test soil reaction at different levels in the soil profile. Check Soil ph on:

Milwaukee USER MANUAL

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

Enzyme Pre-Lab. Using the Enzyme worksheet and Enzyme lab handout answer the Pre-Lab questions the pre-lab must be complete before beginning the lab.

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

LAB 5 - PLANT NUTRITION. Chemical Ionic forms Approximate dry Element symbol Atomic weight Absorbed by plants tissue concentration

The Determination of an Equilibrium Constant

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

INSTRUCTIONS FOR ANALOGUE QUARTZ AND MECHANICAL WATCHES

USEPA Electrode Method Method 8156

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Hygro-Thermometer + InfraRed Thermometer Model RH101

Relative Humidity Calibration Kit

Thermistor Thermometer MODEL NO

AutoRanging Digital MultiMeter

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

Refer to page 6 to page 19 for detailed instructions.

Instruction Manual HI Refractometer for Sucrose Measurements

UltraBasic Benchtop ph Meter Operation Manual

The Influence of Carbon Dioxide on Algae Growth

Private Water Supplies Sampling Manual. A Field Guide

PART I SIEVE ANALYSIS OF MATERIAL RETAINED ON THE 425 M (NO. 40) SIEVE

SINGLE RANGE DS METERS Operation Instructions

Please read and keep these instructions. Run water through your machine before first use

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Electrical Stability Tester, Model 23E Instruction Manual Manual No , Revision B Instrument No

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

digital fever alert ear thermometer suitable from birth instruction manual

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

User's Guide. Pinless Moisture Meter. Model MO257

Forehead. Use and Care Manual. Thermometer IMPORTANT! READ AND SAVE THESE INSTRUCTIONS. Model V977

Standard Test Procedures Manual

ph Measurements of Common Substances

Optical Power Meter. Specification & User Manual

DR/4000 PROCEDURE. CHLORINE, Free

ph Measurement and Control

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Thermocouple Thermometer Models

AIRMoN, ph and Conductivity Field Measurement

SAVE THESE INSTRUCTIONS QUICK SETUP INSTRUCTIONS ACCLIMATING YOUR CAT HOW THE LITTERMAID SELF-CLEANING LITTER BOX WORKS:

SenTix 950 SenTix 980

Instruction manual. VWR unstirred water baths

Dissolved Oxygen Sensors

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

RBS detergents for laboratories

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

Standard Operating Procedure for Cleaning Nylon Filters Used for the Collection of PM 2. 5 Material

Manual Ranging MultiMeter

My Weigh Ultraship Series User Manual

HEART RATE + CALORIE MONITOR

PR 50 Frymaster Universal Holding Cabinet (UHC)

Lab 7 Soil ph and Salinity OBJECTIVE INTRODUCTION Soil ph active

WHAT IS IN FERTILIZER OTHER THAN NUTRIENTS?

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

Tympanic Thermometer

ThermoScan Instant Thermometer IRT 1020 Type 6005 Home Model

Recovery of Elemental Copper from Copper (II) Nitrate

YSI Meter Protocol: Specific Conductivity, ph, & Dissolved Oxygen

Instant Ear Thermometer

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

BODY FAT & HYDRATION % MONITOR SCALE

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

LCD BacPac. User Manual + Warranty Info

TS1200 Intelligent Lead Free Soldering Station. Operation Manual

You have just purchased the most portable and economical spray chrome system in the world!

PART 1 - INTRODUCTION...

FARMEX HT-PRO OPERATING INSTRUCTIONS PORTABLE MOISTURE AND TEMPERATURE TESTER FOR BALED HAY

Chlorine, Total. DPD Method 1 Method to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

For safety information, see the ABI PRISM 310 Genetic Analyzer User s Manual (PN or ).

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

Instruction Manual ph 5+ ph 6+ Ion 6+ Technology Made Easy...

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Experiment 12- Classification of Matter Experiment

Treasure Cove Metal Detector

Soil Sensor Reader PRODUCT MANUAL

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Metal Rescue Rust Remover Technical Data

Mixtures and Pure Substances

DISSOLVED OXYGEN PROBE

body fat scale + Instruction Manual complete body analysis scale HEALTH

Periodic Verification System Model 775PVS

INSTRUCTION MANUAL. Handy Polaris

Transcription:

Instruction Manual www.getbluelab.com

Table of Contents 1.0 Information about measuring the ph of soils/media. 2 2.0 Introduction to Bluelab Soil ph Meter 4 3.0 Preparing the Bluelab Soil ph Meter for Use 5 4.0 Calibrating Meter 6 5.0 Measure Soil ph Value 7 6.0 Measure Soil Solution ph value 8 7.0 Cleaning and Maintenance 9 8.0 Error Messages 9 9.0 Troubleshooting Guide 10 10.0 Technical Specifications 11 Copyright, all rights reserved 1 Version:010709/00236sc

1.0 Information about measuring the ph of soils/media ph is the measurement of the hydrogen ion concentration (H+) - acidity and its opposite, alkalinity. Neutral ph is 7.0 ph. Acidity measures below seven ph (7.0 ph) with alkalinity measuring above it (7.0 ph). Very acid (ph 5.0 to 5.8) Moderately acid (ph 5.5 to 6.8) Slightly acid (ph 6.0 to 6.8) Very alkaline (ph 7.0 to 8.0) In soils or growing media, ph strongly influences the availability of nutrients and the presence of microorganisms and plants in the soil. Certain plants require a particular ph range to enable the required nutrients to be consistently available to the plant. If the solution is too acidic or too alkaline it can cause lock up a situation which restricts certain elements essential for growth from being absorbed by the root structure. This in turn reduces plant health and performance. Deficiencies in the required elements become apparent in plant growth and can lead to crop failure. Low soil ph causes aluminium and manganese toxicity in plants and reduces the availability of soil phosphorus. High soil ph also reduces soil phosphorus availability and reduces micronutrients such as zinc and boron to plants. The chart below shows how nutrient ph levels influence the uptake of certain elements. how nutrient ph affects availability of plant nutrients the width of the bands indicates the relative availability of each plant food element at various ph levels strongly acid medium acid slightly acid very slightly acid very slightly alkaline slightly alkaline medium alkaline strongly alkaline nitrogen phosphorus potassium sulphur calcium magnesium iron manganese boron copper and zinc molybdenum 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 Copyright, all rights reserved 2 Version:010709/00236sc

1.0 Information about measuring the ph of soils/media cont... Taking ph measurements of soils with an electronic meter is indicative rather than absolute. The following factors are outside the control of any Soil ph Meter, so to minimise their effect on the accuracy of the ph measurement you should consider the following precautions: Moisture Level/Raw water - If the sample you are wishing to measure is dry, add distilled water to moisten. If you add tap water, you may influence the ph reading based on the ph of the raw water. Calibration of the ph Meter and cleanliness of the probe tip Calibrating the ph meter at least monthly will ensure accurate readings. Cleaning the soil residue from the probe tip and storing the probe in a clean state will also help to provide reliable readings as well as prolonging the probes life. Sample Selection For feild testing, samples are taken approximately 20 cm / 8 in down into the substrate and from various areas, then an average of the readings is used. For container grown plants, it is recommended to check the ph level of the substrate prior to planting. Factors affecting ph in the soil or media: Soil Type - Soils formed under high rainfall conditions (E.g. Eastern USA) are more acidic than those formed under dry conditions (E.g. Western USA). Growth Stage of the plant Uptake and requirements of particular elements change as the plant progresses through it s growing cycle. Recording ph level data to create a history is valuable. Applications and types of fertilizers This can alter the ph level significantly. The time at which you take the reading is important. Evaluate the brand of fertilizer to see if it is altering the ph in the wrong direction. Applications of Sprays As these can soak into the soil/media a change to the ph level could result. Soil/Media Temperature High temperature soils may have a high concenrtration of CO 2 The higher the concenrtration of Carbon dioxide pressure results in more carbonic acid which lowers ph. Copyright, all rights reserved 3 Version:010709/00236sc

2.0 Introduction to the Bluelab Soil ph Meter The battery operated ph meter measures soil ph levels by using a soil ph probe connected to the electronic meter. The meter has a liquid crystal display (LCD) digital readout. 2.1 Basic Operation 1 Figure 1 shows each functioning part of the Soil ph Meter. The Soil ph probe has a removable wetting cap. It is important that the probe tip is not allowed to dry out. The wetting cap must be placed back onto the probe tip for storage. The meter automatically turns off after approximately four minutes if no buttons are pressed. If the meter turns off during use, a short press of the ON/OFF button will turn the meter on again. Probe Connection Socket (BNC fitting) Reading Display ON/OFF Button Dibber/ Auger ph Probe ph 7.0 Calibration Button ph 4/10 Calibration Button Figure 1. Soil ph Meter Wetting Cap 2.2 Meter Calibration 1 Calibrate the meter before the first use to ensure reading accuracy. Ensure solutions used for calibration are stored to prevent any evapoation and replaced three months after opening. ph reading accuracy is dependent on the accuracy of these calibration solutions and also on age, use and cleanliness of the probe. If measuring a ph below 7.0 is expected, the meter is calibrated using ph 7.0 and ph 4.0 calibrations solutions. If measuring a ph above 7.0 is expected, ph 7.0 and ph 10.0 solutions are used. 2.3 Storage of Meter 4 The meter should be kept out of direct sunlight to prevent irreparable damage to the LCD display; this includes storing in a cool, dry and clean place when not in use. The meter unit is not waterproof but will withstand occasional water splashes. If the meter does get splashed, it is wiped dry as soon as possible. Place a small amount of ph 4.0 solution or fresh water into the probe wetting cap. Replace the wetting cap and store the probe in a secure place. The probe should never be stored in de-ionized or distilled water as this will permanently damage it. Batteries should be removed if the unit is to be stored for a prolonged period. Copyright, all rights reserved 4 Version:010709/00236sc

3.0 Preparing the Soil ph Meter for first time use Preparing the meter for use involves, inserting the supplied 2 x AAA batteries, connecting the probe and calibration. If the probe tip has become dry it will require hydration again before use. 1 Hydrate ph probe if dry Carefully remove probe wetting cap ensuring the body does not bend. Bending the body of the probe can break the glass tube inside. Soak the probe tip in fresh water for at least one hour. Soaking the tip for 24 hours will improve the probe s activity and is recommended. When the probe is not in use, place a small amount of ph 4.0 solution or fresh water into the wetting cap. Place the cap onto the probe tip and store the probe in a secure place. CAUTION: Do not use de-ionized or distilled water. 2 Insert Batteries Open battery compartment by sliding the back cover down and insert 2 x AAA batteries as shown on the battery holder. Slide cover back on. NOTE: Alkaline batteries are recommended. OPEN Figure 2. Battery Cover 3 Connect ph probe Connect the probe to the meter by lining up the meter lugs of the BNC fitting. Fasten securely by pushing probe connector on and twisting one quarter turn. Inserting Twisting Attached Figure 3. Probe Attachment 4 Calibrate the ph Calibrate the meter before use begins by following the instructions in Section 4.0. Copyright, all rights reserved 5 Version:010709/00236sc

4.0 Calibrating Meter For accurate readings the probe must be clean and recently calibrated. Calibration is recommended when: The reading you were expecting is different The probe is replaced with a new one It has been one month since the last calibration Typically more than 30 readings have taken place The meter is reset after an error message ph calibration involves cleaning the probe and then calibrating in TWO SOLUTIONS. If a reading below 7.0 is expected, use ph 7.0 and ph 4.0 calibration solutions. If a reading above 7.0 is expected, use ph 7.0 and ph 10.0 calibration solutions. 1 Clean soil ph probe (not required for initial calibration) Clean probe as described in Section 7.0. 2 ph 7.0 Calibration Turn meter on. Rinse probe thoroughly in fresh water, shake off excess water and place probe in a ph 7.0 calibration solution for at least one minute for reading to stabilize. Press and hold the CAL7 button. When the display starts flashing release the button. If calibration is accepted it will display CAL then 7.0 ph. NOTE: If a message appears during the calibration process, such as E2:PH, the calibration was unreliable. See Section 8.0. Display Stabilized ph 7.0 Calibration Solution Figure 4. Reading Stabilized 3 Rinse Probe Rinse completely in fresh water and shake off excess. 4 ph 4.0/pH 10.0 Calibration Place probe into ph 4.0 or ph 10.0 calibration solution and wait for at least one minute for reading to stabilize. Press and hold CAL 4/10 button. Once the display starts flashing release the button. It will display CAL then 4.0 ph or CAL then 10.0 ph if calibration is accepted, otherwise refer to error messages section 8.0. The meter is now calibrated and ready for use. Copyright, all rights reserved 6 Version:010709/00236sc

5.0 Measure Soil ph Value Once the meter has been set up and calibrated, using it to measure a ph value involves the probe, the green dibber/auger, a soil/media sample and button functions. NOTE: The probe tip must not have dried out. If it has dried, soak the probe in tap water for one hour prior to taking a measurement. 1 Remove the top 5 cm / 2 in. from the surface of the sample area. 2 Insert the dibber/auger into the sample to a depth of about 20 cm / 8 in. and remove. 3 If the soil/media is dry, moisten with a small amount of distilled water. 4 Insert probe to the same depth ensuring it makes proper contact with the soil. 5 Turn the meter on. 6 Wait for the reading displayed on the meter to stablize. This can take up to four minutes. Record the reading. 7 Remove the probe from the soil/media and wash with probe tip under fresh running water (not distilled) to remove any remaining soil residue. 8 Repeat the procedure in different locations and take the average of the measured data as the ph level is representitive of the sample area. 9 Turn Meter off or allow instrument to turn off automatically (after four minutes). If the meter turns off while taking a measurement, simply press the ON/OFF button to turn the meter back on and continue with your measurement. 10 Store Probe Between Measurements Place the wetting cap back on the probe tip with a small amount of fresh water or ph 4.0 solution in it or store probe tip in a container of fresh water between uses. CAUTION: The Soil ph probe is never stored in de-ionized or distilled water as this will permanently damage it. Copyright, all rights reserved 7 Version:010709/00236sc

6.0 Measure soil solution ph value The greatest source of error in soil analysis comes during sample collection. An effort should be made to ensure each sample properly represents the area being sampled. NOTE: The readings taken with this method could be higher than those taken by other methods Consistency of the method used is important to be able to compare sets of results The accuracy of this method cannot be guaranteed because of the variables involved The results should be viewed as 'indicative' rather than 'absolute' 6.1 Collection of Sample 1 Sample in a zig-zag pattern across the required area. 2 Remove 15 mm / in. of top soil before sampling at a depth of 150 mm / 6 in. 3 Mix all collected samples together thoroughly. 4 Allow to dry in the air or in an oven at 40 C / 104 F. 5 Weigh out 20 g / 0.7 oz of the collected soil into a 150 ml / 5 fl oz plastic sample jar. 6.2 Sample Preparation 1 Add 100 ml / 3 fl oz of distilled or deionised water, screw lid on tightly. 2 Shake continuously for 5 minutes. Leave overnight and shake again the next morning. 3 Allow to settle for 15 minutes after shaking and strain sample into clean measuring cup. 6.2 Take ph readings as follows: 1 Insert probe into the soil solution sample. 2 Turn the meter on. 3 Wait for the reading displayed on the meter to stablize. This can take up to four minutes. Record the reading. 4 Remove the probe from the soil solution and wash with probe tip under fresh running water (not distilled) to remove any possible soil residue. 5 Turn Meter off or allow instrument to turn off automatically (after four minutes). If the meter turns off while taking a measurement, simply press the ON/OFF button to turn the meter back on and continue with your measurement. 6.3 Store probe between measurements 1 Place wetting cap back on probe tip with a small amount of fresh water or ph 4.0 solution in it or store probe tip in a container of fresh water between uses. Copyright, all rights reserved 8 Version:010709/00236sc

7.0 Cleaning and Maintenance 7.1 Clean Soil ph Probe 1 Preparation Rinse the probe tip under fresh running water. Fill a small container with clean water and add a small amount of mild detergent. 2 Clean Glassware Place the probe tip into the container and slowly stir it through the liquid several times. If the probe is heavily contaminated, gently brush around the glassware with a few drops of detergent and a soft toothbrush. 3 Rinse Glassware Rinse well under fresh running water to remove all traces of detergent. CAUTION: Do not touch probe glassware with fingers. This will contaminate the probe and affect performance. Do not use excessive force on glassware or the probe body as they are easily damaged. 7.2 Battery Replacement 1 Batteries are replaced in the unit when the message LO BAT appears in top left-hand corner of LCD display. See Section 3.2. NOTE: Batteries should be checked at least once every six months for signs of deterioration, leakage, rusting or swelling. If signs of deterioration are found, the battery holder contacts should be cleaned and the batteries replaced. 8.0 Error Messages Error messages will only appear following ph calibration failure. Error messages are described below. To clear a calibration error message press any button once. The meter will reset to the factory set calibration and will need to be recalibrated successfully before use. Error display Indicates Possible causes E1: PH E2 : PH E3 : PH E4 : PH Not enough difference between ph 7.0 and ph 4.0 readings. Not enough difference between ph 7.0 and ph 10.0 readings. Not enough difference between the readings. ph 7.0 calibration unreliable. ph 4.0 calibration solution contaminated or wrong solution used. Probe contaminated, not properly connected, worn out or damaged. ph 10.0 calibration solution contaminated or wrong solution used. Probe contaminated, not properly connected, worn out or damaged. Calibrate to ph 7.0 FIRST, then to ph 4.0/10.0. ph 7.0 calibration solution contaminated or wrong solution used. Probe contaminated, not properly connected, worn out or damaged. Copyright, all rights reserved 9 Version:010709/00236sc

9.0 Troubleshooting Guide The following table describes problems that can occur with the Soil ph Meter, the possible reasons and explains possible solutions. Trouble Possible reason Possible solution ph readings inaccurate Contaminated probe. Incorrect calibration. Broken glass bulb, stem or connector. Clean ph probe as described in section 7.0. Ensure calibration solutions are accurate. Replace if in doubt. Wait longer for readings to stabilize before calibrating. Check soil ph probe for damage. Display shows LO BAT in top left hand corner Insufficient power to take a reliable reading. Replace the batteries. DO NOT use rechargeable batteries. Meter will not turn on Batteries dead or inserted incorrectly. Check batteries are inserted correctly. Replace if necessary. Display shows E2 : PH or similar Problem with ph calibration or the meter is damaged. See error messages in Section 8.0. orph urph Over range ph Under range ph Solution > 14.0pH Solution < 0.0pH Check ph probe connection. ph probe could be faulty. Meter could be wet inside. Copyright, all rights reserved 10 Version:010709/00236sc

10.0 Technical Specifications Bluelab Soil ph Meter Range 0-14 ph Resolution 0.1 ph Accuracy (at 25 C) + - 0.1 ph Temperature Compensation Not applicable Operating Temperature Range 0-45 C 32-113 F Power Source 2 x AAA Alkaline batteries Calibration Manual calibration Other Features Low battery warning Auto turn off function Over range and under range indicators Contact Details, 43 Burrows Street, PO Box 949, Tauranga, New Zealand Ph +64 7 578 0849 Fax +64 7 578 0847 Email support@getbluelab.com www.getbluelab.com Limitation of Liability: Under no circumstances shall be liable for any claims, losses, costs and damages of any nature whatsoever (including any consequential loss) that result from the use of, or the inability to use, these instructions / and or equipment. Copyright, all rights reserved 9 Version:010709/00236sc