Step 6 Buckling/Slenderness Considerations



Similar documents
Figure A-1. Figure A-2. continued on next page... HPM-1. Grout Reservoir. Neat Cement Grout (Very Flowable) Extension Displacement Plate

Comprehensive Design Example 2: Foundations for Bulk Storage Facility

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

Step 11 Static Load Testing

Laterally Loaded Piles

Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur

Buckling of Micropiles

How to Design Helical Piles per the 2009 International Building Code

Outline MICROPILES SUBJECT TO LATERAL LOADING. Dr. Jesús Gómez, P.E.

Stability. Security. Integrity.

How To Model A Shallow Foundation

III. Compression Members. Design of Steel Structures. Introduction. Compression Members (cont.)

Module 5 (Lectures 17 to 19) MAT FOUNDATIONS

Design of reinforced concrete columns. Type of columns. Failure of reinforced concrete columns. Short column. Long column

vulcanhammer.net This document downloaded from

System. Stability. Security. Integrity. 150 Helical Anchor

APPENDIX A PRESSUREMETER TEST INTERPRETATION

Underpinning Systems 14.1 FOUNDATION REPAIR. Helical Piles

ALLOWABLE LOADS ON A SINGLE PILE

Helical Pier Foundation System U.S. Patents 5,011,336; 5,120,163; 5,213,448

Type of Force 1 Axial (tension / compression) Shear. 3 Bending 4 Torsion 5 Images 6 Symbol (+ -)

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

New construction Repairing failed or old foundations Retrofit foundations Permanent battered piers Machinery/equipment foundations

Page B-1 Hubbell Power Systems, Inc. All Rights Reserved Copyright 2014 LOAD TESTS

Instrumentations, Pile Group Load Testing, and Data Analysis Part II: Design & Analysis of Lateral Load Test. Murad Abu-Farsakh, Ph.D., P.E.

USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch

DESIGN, INSTALLATION AND TESTING OF HELICAL PILES & ANCHORS. Presented by: Donald A. Deardorff, P.E. CHANCE Civil Construction Centralia, MO USA

load on the soil. For this article s examples, load bearing values given by the following table will be assumed.

c. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc.

EXAMPLE 1 DESIGN OF CANTILEVERED WALL, GRANULAR SOIL

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

Lymon C. Reese & Associates LCR&A Consulting Services Tests of Piles Under Axial Load

LATERAL LOAD TESTS ON DRILLED PIERS IN SAN DIEGO AREA RESIDUAL AND FORMATIONAL SOILS

CHAPTER 9 FEM MODELING OF SOIL-SHEET PILE WALL INTERACTION

MODULE E: BEAM-COLUMNS

Foundation Underpinning Process and Relationship with Groundwater in West- Central Florida

PILE FOUNDATIONS FM 5-134

ATLAS RESISTANCE Pier Foundation Systems

PVC PIPE PERFORMANCE FACTORS

product manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer

PDCA Driven-Pile Terms and Definitions

Design Analysis and Review of Stresses at a Point

Dynamic Load Testing of Helical Piles

CEEN Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests

GUIDELINE FOR HAND HELD SHEAR VANE TEST

EFFECTS ON NUMBER OF CABLES FOR MODAL ANALYSIS OF CABLE-STAYED BRIDGES

Transmission Foundations. helical piles and guy anchors for transmission structures.

Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.

The elements used in commercial codes can be classified in two basic categories:

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: HUBBELL POWER SYSTEMS, INC.

In-situ Load Testing to Evaluate New Repair Techniques

5/1/2013. Topics. The challenge is to better maintain native characteristics of soils during and after construction

USE OF CONE PENETRATION TEST IN PILE DESIGN

Tutorial for Assignment #2 Gantry Crane Analysis By ANSYS (Mechanical APDL) V.13.0

SECTION 5 ANALYSIS OF CONTINUOUS SPANS DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE LEAD AUTHOR: BRYAN ALLRED

METHOD OF STATEMENT FOR STATIC LOADING TEST

GEOTECHNICAL ENGINEERING FORMULAS. A handy reference for use in geotechnical analysis and design

Structural Axial, Shear and Bending Moments

Stability Of Structures: Additional Topics

Numerical Analysis of Texas Cone Penetration Test

ENCE 4610 Foundation Analysis and Design

Appendix A Sub surface displacements around excavations Data presented in Xdisp sample file

KWANG SING ENGINEERING PTE LTD

New approaches in Eurocode 3 efficient global structural design

HELICAL SCREW PILES (HSP) CAPACITY FOR AXIAL CYCLIC LOADINGS IN COHESIVE SOILS

INTRODUCTION TO SOIL MODULI. Jean-Louis BRIAUD 1

Introduction to Solid Modeling Using SolidWorks 2012 SolidWorks Simulation Tutorial Page 1

Designed and Engineered to Perform

DESIGNING STRUCTURES IN EXPANSIVE CLAY

Deflections. Question: What are Structural Deflections?

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

Green Thread Product Data

CLASSIFICATION BOUNDARIES FOR STIFFNESS OF BEAM-TO- COLUMN JOINTS AND COLUMN BASES

Helical Piles. A Practical Guide to Design and Installation

The International Workshop on Micropiles, 2007

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

Estimation of Adjacent Building Settlement During Drilling of Urban Tunnels

TYPES OF PIERS USED IN NORTH AND EAST TEXAS RESIDENTIAL FOUNDATION REPAIR

DESIGN OF PILES AND PILE GROUPS CONSIDERING CAPACITY, SETTLEMENT, AND NEGATIVE SKIN FRICTION

Formwork for Concrete

NEW DEVELOPMENTS AND IMPORTANT CONSIDERATIONS FOR STANDARD PENETRATION TESTING FOR LIQUEFACTION EVALUATIONS. Jeffrey A Farrar M.S.

Technical Notes 3B - Brick Masonry Section Properties May 1993

Design of pile foundations following Eurocode 7-Section 7

INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!

High Capacity Helical Piles Limited Access Projects

Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils

Tower Cross Arm Numerical Analysis

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives

PRODUCT DRAWINGS AND RATINGS Section 7

Geotechnical Investigation Test Report

CITY OF LOS ANGELES CALIFORNIA

The Stabilizer TM. Benefits. Supplemental support system for sagging beams and floor joists within a crawl space

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination

ITEM # OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT

DIRT DWELLING. and your. Pin Foundations Inc., 2008

A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil

Figure CPT Equipment

Transcription:

Step 6 Buckling/Slenderness Considerations Introduction Buckling of slender foundation elements is a common concern among designers and structural engineers. The literature shows that several researchers have addressed buckling of piles and micropiles over the years (Bjerrum 1957, Davisson 1963, Mascardi 1970, Gouvenot 1975). Their results generally support the conclusion that buckling is likely to occur only in soils with very poor strength properties such as peat, very loose sands, and soft clay. However, it cannot be inferred that buckling of helical screw foundations will never occur. Buckling of helical screw foundations in soil is a complex problem best analyzed using numerical methods on a desktop computer. It involves parameters such as the shaft section and elastic properties, coupling strength and stiffness, soil strength and stiffness, and the eccentricity of the applied load. This section of the design manual presents a summarized description of the procedures available to study the question of buckling of helical screw foundations, and recommendations that aid the systematic performance of buckling analysis. Background Buckling of columns most often refers to the allowable compression load for a given unsupported length. The mathematician Leonhard Euler solved the question of critical compression load in the 18 th century with a basic equation included in most strength of materials textbooks. P crit = π 2 EI/(KL u ) 2 (Equation 6.1) where: E = Modulus of Elasticity I = Moment of Inertia K = End Condition Parameter L u = Unsupported Length It is obvious that helical screw foundations have slender shafts - which can lead to very high slenderness ratios (Kl/r), depending on the length of the foundation shaft. This condition would be a concern if the screw foundation were in air or water and subjected to a compressive load. For this case, the critical buckling load could be estimated using the well-known Euler equation above. However, helical screw foundations are not supported by air or water, but by soil. This is the reason screw foundations can be loaded in compression well beyond the critical buckling loads predicted by Equation 6.1. As a practical guideline, soil with Standard Penetration Test (SPT) blow count per ASTM D-1586 greater than 4 along the entire embedded length of the screw foundation shaft has been found to provide adequate support to resist buckling - provided there are no horizontal (shear) loads or bending moments applied to the top of the foundation. Only the very weak soils are of practical concern. For soils with 4 blows/ft or less, buckling calculations can be done by hand using the Davisson (1963) method or by computer solution using the finite-difference technique as implemented in the program LPILE PLUS (ENSOFT, Austin, TX). In addition, the engineers at Hubbell Power Systems/ Chance have developed a macro-based computer solution using the finite-element technique with the analysis software ANSYS. If required, the application engineers at Hubbell Power Systems/Chance can provide project specific buckling calculations - given sufficient data relating to the applied loads and the soil 6-1

profile. If you need engineering assistance, please contact the Hubbell/Chance Civil Construction Distributor in your area. Contact information for Hubbell/Chance Civil Construction Distributors can be found at www.abchance.com. These professionals will help you to collect the data required to perform buckling analysis. Buckling Analysis by Davisson Method A number of solutions have been developed for various combinations of pile head and tip boundary conditions and for the cases of constant modulus of subgrade reaction (k h ) with depth. One of these solutions is the Davisson (1963) method as described below. Solutions for various boundary conditions are presented by Davisson in Figure 6.1. the axial load is assumed to be constant in the pile that is no load transfer due to skin friction occurs and the pile initially is perfectly straight. The solutions shown in Figure 6.1 are in dimensionless form, as a plot of U cr versus I max. U cr = P cr R 2 /E p I p Or P cr = U cr E p I p /R 2 (Equation 6.2) R = 4 E p I p /k h d (Equation 6.3) I max = L/R (Equation 6.4) where: P cr = Critical Buckling Load E p = Modulus of Elasticity of Foundation Shaft I p = Moment of Inertia of Foundation Shaft k h = Modulus of Subgrade Reaction d = Foundation Shaft Diameter L = Foundation Shaft Length over which k h is taken as Constant U cr = Dimensionless ratio By assuming a constant modulus of subgrade reaction (k h ) for a given soil profile to determine R, and using Figure 6.1 to determine U cr, Equation 6.2 can be solved for the critical Figure 6.1 Poulos and Davis (1980) buckling load. Typical values for k h are shown in Table 6.1. Table 6.1 Modulus of Subgrade Reaction Typical Values Soil Description Modulus of Subgrade Reaction (k h ) (pci) Very soft clay Soft clay Loose sand 15-20 30-75 20 Figure 6.1 shows that the boundary conditions at the pile head and tip exert a controlling influence on U cr, with the lowest buckling loads occurring for piles with free (unrestrained) ends. 6-2

Design Example 6.1 Determining Critical Buckling Load, P cr, by Davisson Method P cr P cr Model As Foundation 3' Soft Clay N=3 K h=15pci 12' K h=15pci 15' Stiff Clay N 5 A three-helix Type SS150 1 1 / 2 " square shaft helical screw foundation is to be installed into the soil profile as shown above. The top 3 feet is uncontrolled fill and is assumed to be soft clay. The majority of the shaft length (12 feet) is confined by soft clay with a k h = 15 pci. The helix plates will be located in stiff clay below 15 feet. What is the critical buckling load per the Davisson Method? The buckling model above assumes a pinned-pinned end condition for the pile head and tip. The foundation length is 15 feet, which is the shaft length in the soft clay. Physical Properties - Hubbell/Chance Type SS150 Square Shaft Foundations Modulus of Elasticity (E p ) 30 x 10 6 psi Moment of Inertia (I p ) Shaft Diameter (d) 0.396 in 4 1.5 in Assumptions: 1. k h is constant, i.e. it does vary with depth. This is conservative because k h usually does vary with depth, and in most cases it increases with depth. 2. Pinned-pinned end conditions assumed. In reality, end conditions are more nearly fixed than pinned, thus results are generally conservative. R = 4 (30 x 10 6 x 0.396)/(15 x 1.5) = 26.96 I max = (15 x 12)/26.96 = 6.7 From Figure 6.1, U cr 2 P cr = (2 x 30 x 10 6 x 0.396)/26.96 2 = 32.69 kips 6-3

Buckling Analysis by Finite Differences Another way to determine the buckling load of a helical screw foundation in soil is to model it based on the classical Winkler (a mathematician, circa 1867) concept of a beamcolumn on an elastic foundation. The finite difference technique can then be used to solve the governing differential equation for successively greater loads until, at or near the buckling load, failure to converge to a solution occurs. The derivation for the differential equation for the beam-column on an elastic foundation was given by Hetenyi (1946). The assumption is made that a shaft on an elastic foundation is subjected not only to lateral loading, but also to compressive force acting at the center of the gravity of the end crosssections of the shaft, leading to the differential equation: EI(d 4 y/dx 4 ) + Q(d 2 y/dx 2 ) + E s y = 0 (Equation 6.5) where: y = lateral deflection of the shaft at a point x along the length of the shaft x = distance along the axis, i.e. along the shaft EI = flexural rigidity of the foundation shaft Q = axial compressive load on the helical screw foundation E s y = soil reaction per unit length E s = secant modulus of the soil response curve The first term of the equation corresponds to the equation for beams subject to transverse loading. The second term represents the effect of the axial compressive load. The third term represents the effect of the reaction from the soil. For soil properties varying with depth, it is convenient to solve this equation using numerical procedures such as the finite element or finite difference methods. Reese et al. (1997) outlines the process to solve Equation 6.5 using a finite difference approach. Several computer programs are commercially available that are applicable to piles subject to axial and lateral loads as well as bending moments. Such programs allow the introduction of soil and foundation shaft properties that vary with depth, and can be used advantageously for design of micropiles subject to centered or eccentric loads. To define the critical load for a particular structure using the finite difference technique, it is necessary to analyze the structure under successively increasing loads. This is necessary because the solution algorithm becomes unstable at loads above the critical. This instability may be seen as a convergence to a physically illogical configuration or failure to converge to any solution. Since physically illogical configurations are not always easily recognized, it is best to build up a context of correct solutions at low loads with which any new solution can be compared. 6-4

Design Example 6.2 Determining Critical Buckling Load by Finite Difference P cr 5' 50' Layer 1 FILL N=20, C=0 φ=30, γ =48 pcf e 50 =0, K s =60 pci Layer 2 very soft CLAY w/ silt, trace sand N=0, C=15 psf φ=0, γ =25 pcf e 50 =0.06, K s =10 pci A four-helix square shaft helical screw foundation is to be installed into the soil profile as shown above. The top five feet is compacted granular fill and is considered adequate to support lightly loaded slabs and shallow foundations. The majority of the shaft length (50 feet) is confined by very soft clay described by the borings as weight of hammer (WOH) or weight of rod (WOR) material. WOH or WOR material means the weight of the 130-lb drop hammer or the weight of the drill rod used to extend the sampler down the borehole during the standard penetration test is enough to push the sampler down 18+ inches. As a result, a low cohesion value (15 psf) is assumed. The helix plates will be located in dense sand below 55 feet. What is the critical buckling load of Type SS175 1 3 4 " square shaft and Type HS 3 1 2 " pipe shaft foundations using LPILE PLUS 3.0 for Windows (ENSOFT, Austin, TX)? Design Example 6.2 continues, next page Layer 3 silty SAND N=30, C=0 φ=35.5, γ =58 pcf e 50 =0, K s =91pci 6-5

Design Example 6.2 continued Once the computer model is completed, the solution becomes an iterative process of applying successively increasing loads until a physically logical solution converges. At or near the critical buckling Figure 6.2 load, very small Plot of Deflection vs. Depth LPILE PLUS Output increasing increments of for Design Example 6.2 axial load will result in significant changes in lateral deflection which is a good indication of elastic buckling. Figure 6.2 is an LPILE PLUS output plot of lateral shaft deflection vs. depth. As can be seen by the plot, an axial load of 14,561 lb is the critical buckling load for Type SS175 1 3 4 " square shaft because of the dramatic increase in lateral deflection at that load compared to previous lesser loads. Figure 6.3 indicates a critical buckling load of 69,492 lb for Type HS 3 1 2 " pipe shaft. Note that over the same 50-foot length of very soft clay, the well-known Euler equation predicts a critical buckling load for Type SS175 of 614 lb with pinned-pinned end conditions and 2,454 lb with fixed-fixed end conditions. Euler critical buckling load for Type HS is 3,200 lb for pinnedpinned and 12,800 lb for fixed-fixed. This is a good indication that shaft confinement provided by the soil will significantly increase the buckling load of helical screw foundations. This also indicates that even the softest materials will provide significant resistance to buckling. 6-6

All extendable helical screw foundations have couplings or joints - used to connect succeeding sections together in order to install the helix plates in bearing soil. One inherent disadvantage of using the finite difference method is its inability to model the Figure 6.3 Plot of Deflection vs. Depth LPILE PLUS Output for Design Example 6.2 effects of bolted couplings or joints that have zero joint stiffness until the coupling rotates enough to bring the shaft sides into contact with the coupling walls. This is analogous to saying the coupling or joint acts as a pin connection until it has rotated a specific amount, after which it acts as a rigid element with some flexural stiffness. All bolted couplings or joints, including square shaft and pipe shaft foundations, have a certain amount of rotational tolerance. This means the joint initially has no stiffness until it has rotated enough to act as a rigid element. In these cases, it is probably better to conduct buckling analysis using other means, such as finite element analysis, or other methods based on empirical experience as mentioned earlier. If couplings are completely rigid, i.e. some flexural stiffness even at zero joint rotation, axial load is transferred without the effects of a pin connection, and the finite difference method can be used. An easy way to accomplish rigid couplings with pipe shaft foundations is to pour concrete or grout down the ID of the pipe after installation. A better method is to install a grout column around the square or pipe shaft of the foundation using the HELICAL PULLDOWN Micropile (HPM) method. The HPM is a patented (U.S. Patent 5,707,180) installation method initially developed to install helical screw foundations in very weak soils where buckling may be anticipated. The HPM is discussed in the Appendix. 6-7

Buckling Analysis by Finite Elements Hubbell Power Systems/ has developed a design tool, integrated with ANSYS finite element software, to determine the load response and buckling of helical screw foundations. The method uses a limited non-linear model of the soil to simulate soil resistance response without increasing solution solve time inherent in a full nonlinear model. The model is still more sophisticated than a simple elastic foundation model, and allows for different soil layers and types. The screw foundation components are modeled as 3D beam elements assumed to have elastic response. Couplings are modeled from actual test data, which includes an initial zero stiffness, an elastic/rotation stiffness and a final failed condition which includes some residual stiffness. Macros are used to create soil property data sets, helical screw foundation component libraries, and load options w/ end conditions at the pile head. After the helical screw foundation has been configured and the soil and load conditions specified, the macros increment the load, solve for the current load and update the lateral resistance based on the lateral deflection. After each solution, the ANSYS post-processor extracts the lateral deflection and recalculates the lateral stiffness of the soil for each element. The macro then restarts the analysis for the next load increment. This incremental process continues until buckling occurs. Various output such as deflection and bending moment plots can be generated from the results. Design Example 6.3 Determining Critical Buckling Load by Finite Elements Foundation Loose sand N = 5 P cr 12' A three-helix Type SS5 1 1 / 2 " square shaft helical screw foundation is to be used to underpin an existing townhouse structure that has experienced settlement. The top 12 feet is loose sand fill, which probably contributed to the settlement problem. The majority of the shaft length (30 feet) is confined by very soft clay with an SPT blow count of 2. As a result, a cohesion value (250 psf) is assumed. The helix plates will be located in medium-dense sand below 42 feet. What is the critical buckling load using the ANSYS integrated finite element model? Design Example 6.3 continues, next page Soft Clay N = 2 30' Medium Sand N = 20 6-8

Design Example 6.3 continued Output indicates the Type SS5 1 1 / 2 " square shaft buckled at around 28 kip. Figure 6.4 shows the displaced shape of the shaft (exaggerated for clarity). The K0 in Figure 6.4 are the locations of the shaft couplings. Note that the deflection response is controlled by the couplings as would be expected. Also note that the shaft deflection occurs in the very soft clay above the medium-dense bearing stratum. Since the 28 kip buckling load is considerably less than the bearing capacity (55+ kip) it is recommended to install a grout column around the 1 1 / 2 " square shaft using the HELICAL PULLDOWN Micropile (HPM) method. Figure 6.4 Displaced Shape of Shaft ANSYS Output for Design Example 6.3 6-9

References 1. ASTM D 1586, Standard Test Method for Penetration Test and Split-Barrel Sampling of Soils. 2. Bjerrum, L., 1957, Norwegian experiences with steel piles to rock, Geotechnique, Vol.7, 1957. 3. Cadden, Allen and Jesus Gomez, Buckling of Micropiles, ADSC-IAF Micropile Committee, Dallas, TX, 2002. 4. Davisson, M.T., Estimating Buckling Loads for Piles, Proceedings, 2 nd Pan-American Conference on Soil Mechanics and Foundation Engineering, Brazil, Vol. 1, 1963. 5. Design Manual, DM7, NAVFAC, Soil Mechanics, Government Printing Office, 1986. 6. HeliCALC Micropile Design Assessment Program Theoretical and User s Manual, Hubbell Power Systems/A.B. Chance Co., 2001. 7. Hetenyi, M., Beams on Elastic Foundation, The University of Michigan Press, Ann Arbor, MI, 1946. 8. Hoyt, Robert M., Gary L. Seider and Lymon C. Reese, and Shin-Tower Wang, Buckling of Helical Anchors Used for Underpinning, Proceedings, ASCE National Convention, San Diego, CA, 1995. 9. Reese, L.C., The Analysis of Piles Under Lateral Loading, Proceedings, Symposium on the Interaction of Structure and Foundation, Midland Soil Mechanics and Foundation Engineering Society, University of Birmingham, England, 1971. 10. Reese, L.C., W.M Wang, J.A. Arrellaga and J. Hendrix, Computer program LPILE PLUS Version 3.0 Technical Manual, Ensoft, Inc., Austin, TX, 1997. 6-10