Laboratory Exercise: The Precision of Volume Measurements



Similar documents
Calibration of Volumetric Glassware

Measurement and Calibration

Density. mass m volume V

Calibration of Volumetric Glassware

Assessment of Accuracy and Precision

Experiment 1: Measurement and Density

Calibration of Glassware

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

The Molar Mass of a Gas

Density Determinations

The volume of a penny will be calculated from its mass and density.

Glassware Calibration Guidelines Laura B. Secor and Dwight R. Stoll, 02/01/2012 Adapted from National Bureau of Standards Document

Laboratory Exercise: Calibration of a Thermometer

The Composition of Metals and Alloys

COMMON LABORATORY APPARATUS

The Analytical Balance

Acid Base Titrations

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40

Calibration Certificate

thermometer as simple as a styrofoam cup and a thermometer. In a calorimeter the reactants are placed into the

Vitamin C Content of Fruit Juice

Understanding Analytical Chemistry (Weighing, Mixing, Measuring and Evaluating)

Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Chemicals Needed:

Standard Operating Procedure for the Determination of Total and Total Dissolved Solids CCAL 13A.2

STANDARDIZATION OF A SODIUM HYDROXIDE SOLUTION EXPERIMENT 14

Physical Properties of a Pure Substance, Water

EXPERIMENT 9 Evaluation of the Universal Gas Constant, R

Chem 131A: Absorbance of Riboflavin

THE LABORATORY NOTEBOOK

Mixtures and Pure Substances

PART I: PREPARATION OF SOLUTIONS AND STANDARDIZATION OF A BASE

Determination of Citric Acid in Powdered Drink Mixes

Experiment SURFACE TENSION OF LIQUIDS. Experiment 1, page 1 Version of June 17, 2016

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

Analyzing the Acid in Vinegar

Juice Titration. Background. Acid/Base Titration

EXPERIMENT 7 Reaction Stoichiometry and Percent Yield

The introduction of your report should be written on the on the topic of the role of indicators on acid base titrations.

MEASUREMENTS AND ERRORS

Lab 25. Acid-Base Titration and Neutralization Reactions: What Is the Concentration of Acetic Acid in Each Sample of Vinegar?

Density Determinations and Various Methods to Measure

Gravimetric determination of pipette errors

PERCENT ACETIC ACID IN VINEGAR EXPERIMENT 15

Catalytic Activity of Enzymes

KINETIC DETERMINATION OF SELENIUM BY VISIBLE SPECTROSCOPY (VERSION 1.8)

Where the exp subscripts refer to the experimental temperature and pressure acquired in the laboratory.

Standard Test Procedures Manual

experiment5 Understanding and applying the concept of limiting reagents. Learning how to perform a vacuum filtration.

Concentrations and Dilutions of Food Dyes

Neutralizing an Acid and a Base

Experiment 7: Titration of an Antacid

BLOWING UP BALLOONS, chemically

Distillation of Alcohol

Experiment 12- Classification of Matter Experiment

DETERMINING THE ENTHALPY OF FORMATION OF CaCO 3

Acid Base Titration: ph Titration Curve

DETERMINING THE DENSITY OF LIQUIDS & SOLIDS

FederalDemocratic RepublicofEthiopia

Apparatus error for each piece of equipment = 100 x margin of error quantity measured

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1

Experiment 4 The Relationship of Density and Molarity of an Aqueous Salt Solution

To measure the solubility of a salt in water over a range of temperatures and to construct a graph representing the salt solubility.

EXPERIMENT 4 THE DETERMINATION OF THE CALORIC CONTENT OF A CASHEW NUT

SYNTHESIS AND ANALYSIS OF A COORDINATION COMPOUND OF COPPER

Determination of Aspirin using Back Titration

Determination of a Chemical Formula

The Determination of an Equilibrium Constant

Safety and Laboratory Procedures from the CWU Department of Chemistry CHEM 101 Laboratory Manual

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

PHYSICAL AND PLASTICITY CHARACTERISTICS

Three Methods for Calculating the Buoyant Force Gleue: Physics

Apr 17, 2000 LAB MANUAL PARTICLE SIZE ANALYSIS OF SOILS AASHTO Designation T 88 (Mn/DOT Modified)

Percentage of Water in Popcorn

Ascorbic Acid Titration of Vitamin C Tablets This lab will be completed individually! Make sure you come prepared!

Agarose Gel Electrophoresis with Food Color- Teacher Guide

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE ABSORPTION OF CARBON DIOXIDE INTO WATER

Coordination Compounds with Copper (II) Prelab (Week 2)

EXPERIMENT 15: Ideal Gas Law: Molecular Weight of a Vapor

Esterification Method 1 Method to 2800 mg/l (as acetic acid) Reagent Solution

Factors Affecting Enzyme Activity

Partner: Jack 17 November Determination of the Molar Mass of Volatile Liquids

Using Freezing-Point Depression to Find Molecular Weight

AN EXPERIMENT IN ALCHEMY: COPPER TO SILVER TO GOLD 2005, 2000, 1996 by David A. Katz. All rights reserved

1. The Determination of Boiling Point

UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850

Molar Mass of Butane

How to prepare standard solutions

Determination of the Percentage Oxygen in Air

Millikan Oil Drop Experiment Matthew Norton, Jurasits Christopher, Heyduck William, Nick Chumbley. Norton 0

PREPARATION AND PROPERTIES OF A SOAP

Analytical Chemistry Lab Reports

Transfer of heat energy often occurs during chemical reactions. A reaction

Experiment #2: Determining Sugar Content of a Drink. Objective. Introduction

Dissolving of sodium hydroxide generates heat. Take care in handling the dilution container.

SOLID STATE CHEMISTRY - SURFACE ADSORPTION

Quality Assurance/Quality Control in Acid Deposition Monitoring

Students will be able to identify popping corn as a physical change.

Transcription:

CHEM 109 Introduction to Chemistry Revision 3.0 Laboratory Exercise: The Precision of Volume Measurements The accurate measurement of the volume of liquids tends to be difficult and chemists have a number of different types of devices for makin this measurement; beakers, raduated cylinders, volumetric flasks, etc. Each of these devices has a specific purpose and a distinct level of accuracy and precision associated with it. Beakers are used primarily for crudely measurin out lare volumes of liquids, mixin reaents and carryin out chemical reactions. The raduated markins on a beaker are only approximate, so a beaker should never be used for accurate volume measurements. Graduated cylinders are specifically desined to measure out liquid volumes. Their tall narrow desin makes for a more precise readin of the liquid level. If more precision is needed, a volumetric flask can be used. These flasks typically measure a sinle volume via a sinle mark on a tall narrow neck. These flasks are enerally used for solution preparation. Beaker Graduated Cylinder In accurate work it is never safe to assume that the volume delivered by or contained in any volumetric instrument is exactly the amount indicated by the calibration mark. Manufacturers only uarantee the device is manufactured to within some prescribed tolerance. Instead, recalibration is usually performed by weihin the amount of water delivered by or contained in the volumetric apparatus. The mass measurement is then converted into a volume measurement usin the known density of Water. Mass measurements can be made much more accurately and precisely than can volume measurements. Volume = Mass / Density

The density of Water is well known and tabulated values are provided in the Appendix. In addition to recalibratin the volumetric device for accuracy, we can make replicate measurements of the volume contained in or delivered by the device in order to ain an understandin of the precision of the device. The precision can be estimated as the Standard Deviation for the replicate measurements, althouh other more conventional measures, such as the Confidence Interval, based on the standard deviation determination, are more widely used. In our case, we will calibrate two raduated cylinders. The precision of these cylinders will then be compared.

Procedure 1. Obtain about 700 of Distilled Water in an 800 Beaker. This Water will be used to calibrate our Graduated Cylinders. In each case, we will measure the mass of Water, as measured by the device, five times. 2. Measure the temperature of the Water. This is needed because the density of Water is temperature dependent. 3. Obtain a 10 and a 50 Graduated Cylinder. Thorouhly clean each with a test tube brush and some Alconox cleanin solution. (Cleanliness of volumetric lassware is critical to ensure its correct performance.) Water will wet the sides of clean lassware but will not bead-up in drops. 4. Make a note as to whether the Cylinder is a To Contain (TC) or a To Deliver (TD) device. To Contain devices, as the name implies, contain the stated amount of liquid when filled to the mark. To Deliver devices deliver the stated amount of liquid into another container. Account is taken for any liquid remainin wetted on the walls of the device after the delivery. If the Cylinder is a To Contain device: 5. Completely dry the Cylinder and weih it empty usin an Analytical Balance. (Your laboratory instructor will demonstrate the use of the balance. Do not use the balance until you have been shown how to properly use it.) 6. Fill the Cylinder with Distilled Water to the top mark. Make sure no droplets of Water are stickin to the walls above the Water level. If this is the case, use a piece of paper towel to blot them up. Your laboratory instructor will demonstrate how to do this effectively. Make sure your eye is on a level with the mark. A Paralax Error will result, otherwise. This will lead to a readin that is either too hih or too low. Always read the meniscus from the bottom.

Measure the mass of the Cylinder filled with Water. 7. Completely dry the Cylinder and repeat the measurements four more times. 8. Determine the mass of Water contained in the Cylinder for each trial and then use the density to convert this to a volume readin. If the Cylinder is a To Deliver device: 5. Obtain and completely dry a 50 Plastic Beaker and weih it empty usin an Analytical Balance. (Your laboratory instructor will demonstrate the use of the balance. Do not use the balance until you have been shown how to properly use it.) 6. Fill the Cylinder with Distilled Water to the top mark. Make sure no droplets of Water are stickin to the walls above the Water level. If this is the case, use a piece of paper towel to blot them up. Your laboratory instructor will demonstrate how to do this effectively. Make sure your eye is on a level with the mark. A Paralax Error will result, otherwise. This will lead to a readin that is either too hih or too low. Always read the meniscus from the bottom. 7. Transfer the measured amount of Water from the Cylinder to the Plastic Beaker. Measure the mass of the Beaker filled with Water. 8. Completely dry the Cylinder and repeat the measurements four more times. 9. Determine the mass of Water delivered by the Cylinder for each trial and then use the density to convert this to a volume readin.

Appendix - Density of Water Temperature ( o C) Density (/) 10 0.9997026 11 0.9996084 12 0.9995004 13 0.9993801 14 0.9992474 15 0.9991026 16 0.9989460 17 0.9987779 18 0.9985986 19 0.9984082 20 0.9982071 21 0.9979955 22 0.9977735 23 0.9975415 24 0.9972995 25 0.9970479 26 0.9967867 27 0.9965162 28 0.9962365 29 0.9959478 30 0.9956502

Appendix - Tolerances for Class A Graduated Cylinders at 20 o C Capacity () Tolerances () 5 0.05 10 0.10 25 0.17 50 0.25 100 0.50 250 1.00 500 2.00 1000 3.00 The Tolerances for Class B cylinder is typically twice that of a Class A device. (ASTM E 1272-02)

Volume Measurements Water Temperature Water Density o C / 10 Graduated Cylinder TC or TD Class Mass Empty Trial 1 Trial 2 Trial 3 Trial 4 Trial 5 Mass Filled Mass Water Volume Averae Vol. Per. Error % Std. Dev.* Within Tol. 50 Graduated Cylinder TC or TD Class Mass Empty

Trial 1 Trial 2 Trial 3 Trial 4 Trial 5 Mass Filled Mass Water Volume Averae Vol. Per. Error % Std. Dev.* Within Tol. Name: Date: Sinature:

Additional Points to Consider You do not need to submit answers to these questions. However, you should seriously ponder the answers to these questions as they could reappear on an exam. If you are always readin from below the mark, will your volume measurements be infected with a systematic or random error? In this case, will the accuracy or the precision of your measurement suffer? Explain. Most precise volume measurin devices have markins alon a narrow neck? Why do you think this is important?