OUTPUT CABLE CONNECTIONS:



Similar documents
Table of Contents: DELTRAN BATTERY CHARGER GENERAL OPERATING INSTRUCTIONS & USER SAFETY INFORMATION

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

12 Volt 30 Amp Digital Solar Charge Controller

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

ST Series POWER SUPPLIES USER INSTRUCTIONS

User Manual for CH-PFC76810

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

Installation and Operation Back-UPS 1250, 1300, 1500

BATTERY CHARGER MULTI US 7000

750 WATT Power Inverter

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Portable Solar Kits Owner s Manual

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

Mobile Data Power Model: MDP-25

Powerware 5110 UPS User s manual

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

WD-AMX Water Detection Controllers

User s Manual Before using the inverter, you need to read and save the safety instructions.

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

MXS 3. MANUAL FULLY CHARGED PULSE, MAINTENANCE CHARGING EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT CHARGE CABLE ERROR LAMP MODE- BUTTON

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Installation and Operating Instructions (for chargers shown below)

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Handheld portable appliance testers

13 Watt PORTABLE SOLAR POWER KIT

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

SNMP Web Management. User s Manual For SNMP Web Card/Box

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

3000W Power Inverter

Owner's Manual and Installation Guide

Schauer 3210 Wasson Road Cincinnati, Ohio For More Information Or Call VOLT (8658).

Back-UPS Pro 1300/1500 Installation and Operation

Home Solar Kit Owner s Manual. Model: HS

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

POWER TO GET THE JOB DONE

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

Battery Power Inverters

MULTI XS 4003 Battery charger

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

User Manual HomeGrid 3000 Solar Generator

Solar Controller / Battery Charger User s Manual

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

NGSS Data Consolidator (DC)

Installation and Operation Guide for PD4100 Series Power Control Centers

MAJORSINE Power Inverter

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

DCS Series 1 kw, 1.2 kw, & 3 kw

Switch Mode, Automatic, Lead Acid Battery Charger 3 Stage (IUoU)

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

Thyristor-controlled power supplies and battery chargers

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

12-Volt 10-Amp Regulated Power Supply

Installation and Operation Guide for PD4000 Series Power Control Center

70-Series CAN Power Management System

Battery charger. Art.no Model CB5-5L-BS1 ENGLISH SVENSKA NORSK SUOMI. Ver Original instructions

Home Solar Kit Owner s Manual. Model: HS

Power your CPAP machine no matter where your world takes you!

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Manual. Solar Fountain Mobile Phone Charger

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

BATTERY CHARGER OWNER S MANUAL

Residential Gateway (RG) Battery Backup REV B

User s Manual AURORA 1.2K/2.2K

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

CHARGING SYSTEMS INTERNATIONAL

Constant Voltage Charger Selection for VRLA Batteries

XPower 1500 Portable Household Power

LOXONE 12 Channel Amplifier

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Mini Power Bank and Charger

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

If you accidentally get battery acid on your skin, flush it with lots of water

Product Specification instalert Rapid Messenger Variable Message Sign

ProTournament Series. Owner's Manual and Installation Guide. ProMariner. ProMariner. Professional Grade 3 Step Marine Battery Chargers WATERPROOF

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Charger Output AC Ripple Voltage and the affect on VRLA batteries

SOLAR POWER - THE NEW WAY TO RV!

UPS Applications and VRLA Battery Sizing

MODEL 2202IQ (1991-MSRP $549.00)

Cabela's Advanced Angler Prosport II Chargers. Set Number SKU

VLT Series 300 Watt True Sine Wave Inverter

Self Monitoring Power Supply (BPSM)

EGSTON Standard E2xFxWx 12W

Troubleshooting the Verizon MI424WR Router

TROUBLESHOOTING GUIDE

Transcription:

Tender Plus: Models: 12V1.25A and 6V1.25A The Tender Plus 12 Volt, 1.25 Amp 6 Volt, 1.25 Amp GENERAL DESCRIPTION: The Tender Plus battery charger is a desktop, portable, linear power converter that has a true DC output at a maximum power level of approximately 18 or 9 watts respectively for the 12V and 6V models. Both models have a maximum output charging current of 1.25 amps. NOTE: In recent years, the Sealed, GRT (Gas Recombinant Technology), AGM (Absorbed Glass Matte), Lead-Acid battery has enjoyed widespread acceptance in a variety of applications traditionally dominated by flooded battery technology. The Tender Plus battery charger circuitry provides a superior configuration to accommodate the more demanding recharge requirements of this superior battery technology. Although the original Tender battery charger will recharge AGM batteries, the full recharge time is longer than with the Tender Plus battery charger. This is because of the different implementation of the absorption charge mode between these two chargers. Those differences are spelled out in detail in other documents on the website. See Utility / Frequently Asked Questions. OUTPUT CABLE CONNECTIONS: The battery charger DC output cable has a molded, quick disconnect plug. The ring terminal, alligator clip, and cigarette adapter output cable accessories all contain the mating plug. STATUS INDICATOR LIGHTS: The following describes the operation of the status indicator lights: RED FLASHING - When the red light is flashing, the AC power is applied to the charger & the microprocessor circuitry is functioning properly, but the DC output cables are not connected correctly. RED - When the red light is on, the battery charger is in the process of fully charging the battery. In order to properly charge large capacity batteries, the charger may remain in this mode for several hours or even days. GREEN FLASHING - When the green light is flashing, and the red light is on, the battery is greater than 80% charged and may be removed from the charger and used if necessary. Leave the battery on charge until the green light is solid whenever possible. Once the green light begins to flash, it will remain flashing until either the battery charger output current drops below 0.1 amp, or until 6 to 8 hours has elapsed. Deltran Corporation, 801 U.S. Hwy 92 East, DeLand, FL 32724 Page 1 of 5

GREEN - When the green light is lit, the battery charger is in the storage mode of charge. In this mode the charger will maintain the battery at full charge. SPECIAL TROUBLESHOOTING INFORMATION: 1) NEITHER OF THE CHARGER STATUS INDICATOR LIGHTS TURN ON: a) Disconnect the charger AC power plug from the AC outlet and recheck that the battery charger alligator clips or ring terminals are connected to the correct polarity battery terminals and that they are making a clean, tight connection. b) Check to make sure that the AC outlet is supplying power by plugging in another appliance like a lamp, or check the outlet voltage with a voltmeter. 2) THE STORAGE/FLOAT MAINTENANCE STATUS INDICATOR LIGHT (GREEN LIGHT) GOES ON IMMEDIATELY WHEN CHARGING A BATTERY KNOWN TO BE DISCHARGED: a) The battery may be defective. Take the battery to the dealer to be tested. b) The electrical connections between the charger and the battery may not be completely secured. 3) AFTER THE STORAGE/FLOAT MAINTENANCE STATUS INDICATOR LIGHT (GREEN LIGHT) HAS BEEN ON, AND THE AC POWER IS REMOVED FROM THE CHARGER AND THEN IMMEDIATELY RECONNECTED, IT SEEMS TO TAKE TOO MUCH TIME FOR THE GREEN LIGHT TO COME ON AGAIN. a) This is NORMAL OPERATION for the Tender Plus. b) Whenever AC power is removed from the charger, including momentary AC power outages, the charge cycle resets. Therefore, the battery charge current either has to drop to below 0.1 amp or 6 to 8 must elapse before the green light stops flashing. 4) AFTER THE STORAGE/FLOAT MAINTENANCE STATUS INDICATOR LIGHT (GREEN LIGHT) HAS BEEN ON, THE RED LIGHT COMES ON. a) This is NORMAL OPERATION for the Tender Plus. b) There has been a momentary AC power outage that reset the charge cycle. c) There is some other load or appliance drawing power from the battery. When the battery voltage drops below 12.0V to 12.5V, the charge cycle resets. Deltran Corporation, 801 U.S. Hwy 92 East, DeLand, FL 32724 Page 2 of 5

Tender Plus (12 & 6 Volt) Charger Specification Summary Deltran Part Number: 021-0128-1 021-0128-2 021-0128-3 021-0128-4 021-0144 Nominal Output: : 12 Volts 12 Volts 12 Volts 12 Volts 6 Volts Current: 1.25 Amps 1.25 Amps 1.25 Amps 1.25 Amps 1.25 Amps Input : 115 VAC 220 VAC 230 VAC 240 VAC 115 VAC Input Frequency: 60 Hz 50 Hz 50 Hz 50 Hz 60 Hz Maximum Input Current: 0.36 Arms 0.19 Arms 0.18 Arms 0.17 Arms 0.18 Arms Nominal Efficiency: 55% 55% 55% 55% 55% Nominal Power Factor: 0.8 0.8 0.8 0.8 0.8 Charger Output: Maximum Power: (+/- 3%) @ 25 C 18 Watts 9 Watts Maximum Current: 1.25 Amps 1.25 Amps During Bulk Charge Absorption : 14.4 VDC = (2.4 vpc) 7.2 VDC = (2.4 vpc) Absorption to Float Transition: Charge Current drops: below 0.1 Amp or Absorption Charge Duration exceeds 6 Hours, or if battery voltage does not reach Absorption Charge level within 72 hours. Equalization : NA Float : 13.2 VDC = (2.2 vpc) 6.6 VDC = (2.2 vpc) Charge Reset: Threshold 12 to 12.5 VDC (2 to 2.08 vpc) Output Regulation: Line (Typical): Less than 1% at 120VAC Electrical Isolation: Input / Output: 1500 VAC Input / Chassis: 1500 VAC Output / Chassis: 500 VAC Operating Temp: -20 C to 50 C Dimensions: 4.875 in(124 mm)l x 3.25(83 mm)w x 2.875 in(73 mm)h Weight: 2.7 lbs. Carton Size: 6 in(153 mm)l x 6 in(153 mm)w x 6 in(153 mm)h Shipping Weight: 3 lbs. Enclosure: Powder Coated Aluminum Chassis Special Features: Short Circuit Protection: Reverse Polarity Protection: Spark Proof: Temperature Compensation: = -3.5mV/ C/Cell Agency Listings: UL, ETL, CSA, etc. 6 to 6.2 VDC (2 to 2.07 vpc) Selected models are listed to UL-1236 and CSA 22.2 Contact the office in DeLand, FL for information on agency listings. Phone: 386-736-7900 Table 1 Specification Sheet: Tender Plus (12V and 6V) Deltran Corporation, 801 U.S. Hwy 92 East, DeLand, FL 32724 Page 3 of 5

Tender Plus 6V1.25A: Stage 1) Bulk Charge: Red Light On, Green Light Off, Constant Current = 1.25 Amps, Transition to Stage 2, Absorption Charge when battery voltage reaches 7.25 VDC. Stage 2) Absorption Charge: Red Light On, Absorption = 7.25 VDC Transition to Float Charge when battery charging current drops below 0.1 amp or until 6 to 8 hours have elapses. Stage 3) There is no Equalization Charge, Go directly to stage 4. Stage 4) Float Charge: Red Light Off, Green Light On. Float = 6.6 VDC. If an external load is applied to the battery while the charger is in stage 4, Float Charge, and if the battery voltage drops below a range between 6.0 to 6.25 VDC, then the charge cycle restarts. Terminal (VOLTS) R Tender Plus Charger 6 Vdc 1.25 Adc Output Typical Charging Curve Charging Current (AMPS) 10.0 2.0 9.5 9.0 Approximately 80% Recharged 100% Recharged 1.8 1.6 8.5 8.0 7.5 1.25 Amps Bulk Charge Absorption (6 to 8 Hours Max) 1.4 1.25 1.2 1.0 7.0 6.5 7.25 Volts Float / Maintenance 6.6 Volts 0.8 0.6 6.0 5.5 5.0 0.1 Amp 0.4 0.2 0.1 0 0 1 2 3 4 5 6 7 Charging Time (Hours) 8 9 10 11 12 13 14 15 16 Figure 1 Charging Graph: Tender Plus 6V1.25A Deltran Corporation, 801 U.S. Hwy 92 East, DeLand, FL 32724 Page 4 of 5

Tender Plus 12V1.25A: Stage 1) Bulk Charge: Red Light On, Green Light Off, Constant Current = 1.25 Amps, Transition to Stage 2, Absorption Charge when battery voltage reaches 14.4 VDC. Stage 2) Absorption Charge: Red Light On, Absorption = 14.4 VDC Transition to Float Charge when battery charging current drops below 0.1 amp or until 6 to 8 hours have elapsed. Stage 3) There is no Equalization Charge, Go directly to stage 4. Stage 4) Float Charge: Red Light Off, Green Light On. Float = 13.2 VDC. If an external load is applied to the battery while the charger is in stage 4, Float Charge, and if the battery voltage drops below a range between 12.0 to 12.5 VDC, then the charge cycle restarts. Terminal (VOLTS) 16.0 R Tender Plus Charger 12 Vdc 1.25 Adc Output Typical Charging Curve Charging Current (AMPS) 2.0 15.5 15.0 Approximately 80% Recharged 100% Recharged 1.8 1.6 14.5 14.0 13.5 1.25 Amps Bulk Charge 14.4 Volts Absorption (6 to 8 Hours Max) Float / Maintenance 13.2 Volts 1.4 1.25 1.2 1.0 13.0 12.5 12.0 11.5 11.0 100% Charge 12.9 Volts Open Circuit Range 0% Charge 11.4 Volts 0.1 Amp 0.8 0.6 0.4 0.2 0.1 0 0 1 2 3 4 5 6 7 Charging Time (Hours) 8 9 10 11 12 13 14 15 16 Figure 2 Charging Graph: Tender Plus 12V1.25A Deltran Corporation, 801 U.S. Hwy 92 East, DeLand, FL 32724 Page 5 of 5