Wastewater Treatment Additives



Similar documents
ION EXCHANGE FOR DUMMIES. An introduction

Hardness ions also interfere with many chemical processes such as chemical compounding and aqueous cleaners.

Water Softening for Hardness Removal. Hardness in Water. Methods of Removing Hardness 5/1/15. WTRG18 Water Softening and Hardness

GUIDELINES FOR LEACHATE CONTROL

SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS

Chemistry at Work. How Chemistry is used in the Water Service

ECOAZUR BLUEWATER WATER PURIFICATION PLANTS

Best Practice in Boiler Water Treatment

BASIC WATER TREATMENT OF STEAM BOILERS

Case Study: Optimizing Scale Inhibition Costs in Reverse Osmosis Desalination Plants

The chemical components of detergents and their roles in the washing process

Wastewater Reuse. Typical treated wastewater is:

Development of Advanced Wastewater Treatment and Reclamation System

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

Factors Affecting Precipitation of Calcium Carbonate

Ion Exchange Softening

VIPCLEAN Via Goretta 96/A Mappano di Caselle (TO) Tel Fax

Reverse Osmosis Membranes for Wastewater Reclamation By Craig R. Bartels, PhD Hydranautics, 401 Jones Road, Oceanside California, USA 92054

Chapter 6. Solution, Acids and Bases

Water Treatment and Reverse Osmosis Systems

Organic Chemistry Lab Experiment 4 Preparation and Properties of Soap

WATER-SOLUBLE METALWORKING FLUIDS

WATER CHEMISTRY AND POOL WATER BALANCE

The National Board of Boiler and Pressure Vessel Inspectors 1055 Crupper Avenue Columbus, Ohio

Phosphorus Removal. Wastewater Treatment

HUBER Vacuum Rotation Membrane VRM Bioreactor

Phosphate Recovery from Municipal Wastewater through Crystallization of Calcium Phosphate

WATER TREATMENT GLOBAL PRODUCT SELECTION GUIDE

WASTEWATER TREATMENT OBJECTIVES

ION EXCHANGE RESINS INTRODUCTION

Pure Water. Isn t Hard to Find

The Grand Miramare Hotel Santa Margherita (Portofino) Italy March 19 22, Inspiring Innovation and Excellence

Feasibility study of crystallization process for water softening in a pellet reactor

Chapter 5 Student Reading

Chapter 16: Tests for ions and gases

Chapter 2. The Chemistry of Life Worksheets

Subject: Technical Letter 22 April 1977 Removal of Water Supply Contaminants -- Copper and Zinc

SARKOSYL O, an N-acyl sarcosine, is a corrosion inhibitor for lubricating oils, greases O R C N CH COOH CH 2 3

4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES

Silica Over-Saturation, Precipitation, Prevention and Remediation In Hot Water Systems Edited By Dave Peairs, Cal Water, Technical Director

THE USE OF OZONE IN COOLING TOWERS

PROPAK AquaBio Complete Water Restoration Systems

Brewery Wastewater: 2010 Water and Wastewater Conference Page 1

Troubleshooting Your RO

Chemistry B11 Chapter 6 Solutions and Colloids

Chapter 14 Solutions

Reuse of Alternative Water Sources for Cooling Tower Systems Two Case Studies Using Non-Traditional Water Sources

Environmental Technology March/April 1998

CHEMICAL PRECIPITATION: WATER SOFTENING

Ion Exchange Design Hand calculation. Brian Windsor (Purolite International Ltd)

Restoring bore pump performance

Dissolved Mineral Radioactivity in Drinking Water


7. A selectively permeable membrane only allows certain molecules to pass through.

1. Inspection and monitoring... 3

Syllabus OC18 Use litmus or a universal indicator to test a variety of solutions, and classify these as acidic, basic or neutral

CHAPTER 3: MATTER. Active Learning Questions: 1-6, 9, 13-14; End-of-Chapter Questions: 1-18, 20, 24-32, 38-42, 44, 49-52, 55-56, 61-64

Experiment #10: Liquids, Liquid Mixtures and Solutions

Experiment 8 - Double Displacement Reactions

CHAPTER 13: SOLUTIONS

IB Chemistry 1 Mole. One atom of C-12 has a mass of 12 amu. One mole of C-12 has a mass of 12 g. Grams we can use more easily.

Guidelines for Selecting and Maintaining Glycol Based Heat Transfer Fluids

TEACHER ACTIVITY GUIDE

Cleaning Fluids: Soaps and Detergents

Basics of Reverse Osmosis

Additional Lecture: TITRATION BASICS

Removing Heavy Metals from Wastewater

Lesson Plan: How Do We Clean Polluted Water?

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

ENE 806, Project Report 3 CHEMICAL PRECIPITATION: WATER SOFTENING. Grégoire Seyrig Wenqian Shan

Keystone Review Practice Test Module A Cells and Cell Processes. 1. Which characteristic is shared by all prokaryotes and eukaryotes?

Chapter 3: Separating Mixtures (pg )

TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES

5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS

DEPARTMENT OF ENVIRONMENTAL REGULATION. Technical Document DETERMINING REPRESENTATIVE GROUND WATER SAMPLES, FILTERED OR UNFILTERED

Coagulation and Flocculation

Teacher Demo: Turning Water into Wine into Milk into Beer

WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS )

Chemistry 51 Chapter 8 TYPES OF SOLUTIONS. A solution is a homogeneous mixture of two substances: a solute and a solvent.

Mixtures and Pure Substances

GEOL 414/514 CARBONATE CHEMISTRY

CHAPTER 7: REMEDIATION TECHNOLOGIES FOR CONTAMINATED GROUNDWATER

Irrigation Water Quality for Greenhouse Production

Unit 2: Quantities in Chemistry

The Use of Magnesium Hydroxide Slurry as a Safe and Cost Effective Solution for H 2

GE Power & Water Water & Process Technologies. Water and Process Solutions for the Refining Industry

Compounds vs mixtures. Physics and Chemistry IES Jaume Salvador i Pedrol February 2009

ph Measurements of Common Substances

Warm-Up 9/9. 1. Define the term matter. 2. Name something in this room that is not matter.

A. Types of Mixtures:

Separation by Solvent Extraction

Facility Classification Standards

How To Develop A Water Technology Business In Kemira

Honors Chemistry: Unit 6 Test Stoichiometry PRACTICE TEST ANSWER KEY Page 1. A chemical equation. (C-4.4)

WHEY PRODUCTS. Demineralised whey powder is made by removing dissolved salts and water.

Understanding ph management and plant nutrition Part 5: Choosing the best fertilizer

ROSS Technology Removal of Oil, Solids and Scale Formers

ANSWER KEY. Acids, Bases, and Solutions. Chapter Project Worksheet 1 1. Answers will vary. Sample: cherries, blueberries,

2 MATTER. 2.1 Physical and Chemical Properties and Changes

Case History Report The Dolphin Nonchemical Device Boilers and Cooling Tower

Transcription:

Chemicals BV for tomorrow s Technology Wastewater Treatment Additives for tomorrow s World

2

Contents 1. Introduction 2 2. Water treatment methods 3 2.1 Mechanical-chemical treatment 3 2.2 Biological treatment 3 3. Industrial sewage system set-up 3 4. Wastewater pre-treatment 3 5. Pre-settle 3 6. Biological stage 4 6.1 Surface aeration 4 6.2 Submerged aeration 4 6.3 Tower biology 4 6.4 Other aeration techniques 4 7. Final sedimentation 4 8. Foam Control Agents 5 8.1 Foam Control Agent usage 5 8.2 Selection of Foam Control Agents 5 9. Scaling and Anti-scalants 5 10. Conclusion 7 11. Selection guide 8 3

1. Introduction Natural Increasing living standard and consumption of goods is followed by the increase of waste products. This implies that water supply and wastewater treatment obtain high priority for all kind of industries. In order to keep up with fresh water supply, usage of wastewater treatment plants became a standard practise for the majority of the industries producing considerable amount of wastewater. During purification of the wastewater, there is an increasing tendency of foam-build up. Usage of Foam Control Agents is highly recommended in order to achieve an optimised wastewater treatment process. The increasing number of waste treatment plants and the very strict environmental restrictions for industrial waste leads to a strong increase in Foam Control Agents (FCA). The composition of wastewater varies dramatic and it is advised to split the wastewater in industrial applications. Industrial wastewater again, differs strongly from communal wastewater. Communal wastewater consists mainly of non-ionic and anionic surfactants. Because of the high diluting factor, the communal wastewater does show a high foam tendency. This in contrast to the industrial wastewater, which shows a high concentration of industrial waste, dissolved in the water. The increase in foam tendency of industrial wastewater can be found in: Larger wastewater quantities; Higher content of foaming substances in the wastewater; Biodegradation becomes more difficult; therefore more intensive treatment is required. The chemical industry consumes the highest amount of water (one third of the fresh water consumption). About 80% of this fresh water is used for cooling processes. The chemical process takes 16% of the used water in account and only 2% is used as boiling feed water and drinking water for employees. Chemical industries that produce and/or handle emulsions based systems and industries handling methyl cellulose do produce wastewater with a strong foam tendency. Running a wastewater treatment plant is not an easy task because of the different kind of chemicals dissolved in the wastewater. Adequate inoculums have to be selected enabling one to biodegrade the chemicals dissolved in the wastewater. The composition of the industrial wastewater also alters many times. This asks for a fast change in treatment of the wastewater. For this reason there are many different wastewater treatment processes available. A correct choice of the treatment leads to a very effective biodegradation of the chemicals. Below the most well known treatment processes are discussed in brief. 4

2. Water treatment methods 2.1 Mechanical-chemical treatment Solids have been removed from the wastewater and water was collected in large basins in order to allow solids to settle to the bottom. This was the version of a wastewater treatment plant. Later, flocculants were used in order to improve the settling of the solids and a better clarification was achieved. This (very simple) treatment of wastewater is still in use. 2.2 Biological treatment Majority of industries is using a so-called biological clarification in combination with the mechanicalchemical treatment. The biological treatment is a foam active process and requires Foam Control Agents. The principle is the same as applied in fresh water and seas: micro organism use the pollution as nutrient and produce by using oxygen (aerobic) cell substances and carbon dioxide or without oxygen (anaerobic) manure gas (methane). Water treatment plants apply the aerobic process. Sometime a combination of both methods is applied. The supply of oxygen can be achieved in different ways. The most convenient and easiest way is by stirring. The stir process adds also to the foam tendency. The presence of oxygen is, of course, the key to an optimised biodegradation process. 3. Industrial sewage system set-up The communal sewage plants are all similar because the wastewater composition from this source is more or less the same. Industrial sewage systems can differ because the wastewater composition often differs dramatic from each other, i.e. it depends what kind of industry is attached to the sewage system. In some cases the communal wastewater and industrial wastewater is pre-mixed with each other in order to keep the running cost low (no extra sewage system for the communal wastewater). In this case the composition of the wastewater is also kept uniform; this is an advantage for the micro organism used in the sewage systems (adaptation of the micro-organism). Industrial sewage systems consist of different treat stages: Pre-treatment; Pre-settle; Biological stage; Final sedimentation. 4. Wastewater pre-treatment Many chemical production processes include the usage of acids or lye. For this reason, the majority of the incoming wastewater has to be neutralised first. The neutralisation takes part after the settling of the rough dirt has been collected. 5. Pre-settle The dissolved heavy metal will separate as hydroxides after the neutralisation reaction. These hydroxides are collected together with other solids during the so-called pre-settle process. The pre-settle process is carried out in pre-clarification ponds. The process can be accelerated by the usage of flocculants. The pre-clarified water is now pumped into the biological pond. During this pump activity, the water passes different kind of sieves and filters in order to filter out more, small sized solids. 5

6. Biological stage The active sludge in the biological pond is responsible for the biodegradation. This biodegradation is mainly an aerobic process. There are many different ways to add oxygen to the biological pond in order to optimise the biodegradation. 6.1 Surface aeration This is the most widely used process. The water goes in to ponds with a 3 to 4 m. depth. At the surface there are large stirrers (aerators), which produce a high turbulence. The turbulence leads a high amount of oxygen into the biological pond. This process leads to a high foam activity. In order to prevent a strong foam activity, the operators use Foam Control Agents. The stirrers are responsible for a good distribution of the Foam Control Agent. The usage of an active Foam Control Agent is critical because the presence of foam decreases the air supply dramatically. 6.2 Submerged aeration The ponds have a depth of 6 to 8 meters. The air supply is achieved via large nozzles, which blow air in the liquid. The advantage of this technique that the air distribution is more effective as in the previous mentioned method (stirring). This method also asks for an effective Foam Control Agent. 6.3 Tower biology Tower-biology refers to the latest technology in wastewater treatment. The biodegradation takes place in steel containers, which measure 30 meters, height. The principle is similar to a fermentation tower for yeast production. Advantages of this technology are: Better oxygen utilisation; Space saving construction; Odourless process. The containers are closed. The produced gases and excess of oxygen are treated afterwards. 6.4 Other aeration techniques A few other systems are in use; however, they never became common systems in the wastewater treatment process such as: second aeration stage droppers (towers filled with so-called droppers where the wastewater is added from the top to the liquid stored in the wastewater tower. All the above systems deal with standard air. In very special cases, pure oxygen is added to the wastewater. It is obvious that these ponds are covered in order to keep the oxygen in the pond and a minimum will evaporate. 7. Final sedimentation The activated sludge and clarified wastewater have to be separated after the biodegradation. The water is transferred into the final sedimentation ponds. Flocculants are added to the waste in order to accelerate the sedimentation process. A part of the activated sludge transferred back to the biological pond, the remaining sludge is de-watered and treated together with the primary sludge. A problem can occur when the sludge floats on top of water ponds, i.e. the entrapped air prohibits the settling of the sludge. To prevent that the sludge will be carried away together with the water, the ponds do have a skimmer, which holds back the sludge, which floats on top of the water. However this is a problem, which finds its roots in the dissolved air in the water. The obvious solution is to use anti foam, which acts as deaerator as well. The lack of air in the water reduces the problem of floating sludge on the water. See the reference chart for suitable deaerator (Foamstop 150N; Foamstop 600N; Foamstop CC 11). 6

8. Foam Control Agents During the biodegradation process, many gases evaporate from the liquid. This leads to foam development. In order to control the foam activity Foam Control Agents are selected. 8.1 Foam Control Agent usage The majority of the dosage points are at the biological treatment ponds. These ponds do contain the micro organism as well, so it is extreme important that not all the air is taken from the liquid. A too low content on oxygen will lead to a reduced activity of the micro organism or even non-active micro organism. For this reason, the correct choice of Foam Control Agent, which leads to good anti foam properties and a balanced air content, is the key to a successful biodegradation. The Foam Control Agent should be very effective (low extra addition of organic material) and be biodegradable as well. Mineral and preferably biodegradable Vegetable oil based Silicone free Foam Control Agents are preferred. 8.2 Selection of Foam Control Agents The composition of the wastewater might vary over a period of time and most industrial sewage systems are different from each other, for this reason it is recommended to test the Foam Control Agent at small scale before it is used in larger scale. The evaluation should carry out with fresh wastewater. Wastewater, which has been biodegraded already at a certain stage, is not a good reference. The test can be carried out in the laboratory. 9. Scaling and Anti-scalants Scaling means the deposition of particles on a surface like for instance a membrane, causing it to plug. Without some means of scale inhibition, reverse osmosis (RO) membranes and flow passages within membrane elements will scale due to precipitation of sparingly soluble salts, such as calcium carbonate, calcium sulphate, barium sulphate and strontium sulphate. Crystallization of sparingly soluble salts such ascalcium carbonate and calcium sulphate dihydrate is known to occur when certain surface and ground waters are used as the water source in membrane desalination processes. Most natural waters contain relatively high concentrations of calcium, sulphate and bicarbonate ions. In membrane desalination operations at high recovery ratios, the solubility limits of gypsum and calcite exceed saturation levels leading to crystallization on membrane surfaces. The surface blockage of the scale results in permeate flux decline, reducing the efficiency of the process and increasing operating costs. To avoid scaling difficulties, it is essential to restrict the fractional recovery of purified water below a threshold limit at which there is a risk of scale precipitation. In view of the economic benefit of high water recovery, the effective solubility limits of scaling salts, and hence the allowable water recovery, are usually extended by anti-scalant treatment. There are three methods of scale control commonly employed: Acidification; Ion exchange softening; Anti-scalant addition. Acidification: acid addiction destroys carbonate ions, or removing one of the reactants necessary for calcium scale precipitation (sulphate). This is very effective in preventing the precipitation of calcium scale, but less effective in preventing other types of scale. Additional disadvantages include the corrosion by the acid, the cost of tanks and monitoring equipment and the fact that acid lowers the ph of the RO permeate. ADDAPT Chemicals BV offers Phosphate esters (PEX-080B and PEX- 106) which, when used neat, can be used against Calcium scale. Contrary to pure acids, they exhibit enhanced corrosion inhibition. 7

Ion exchange softening: this method utilizes the sodium which is exchanged for magnesium and calcium ions that are concentrated in the RO feed water, following the chemical equations: Ca 2+ + 2NaZ 2Na + + CaZ 2 Mg 2+ + 2NaZ 2Na + + MgZ 2 (NaZ represents the sodium exchange resin) When all the sodium ions have been replaces by calcium and magnesium, the resin must be regenerated with a brine solution. Ion exchange softening eliminates the need for continuous feed of either acid or anti-scalant. Anti-scalants: they are surface active materials that interfere with precipitation reactions in three primary ways: Threshold inhibition: it is the ability of an anti-scalant to keep supersaturated solutions of sparingly soluble salts. Crystal modification: it is the property of an anti-scalants to modify crystal morphology, resulting in soft non adherent scale. As a crystal begin to form at the sub microscopic level, negative groups located on the anti-scalant molecule attack the positive charges on scale nuclei interrupting the electronic balance necessary to propagate the crystal growth. When treated with crystal modifiers, scale crystals appear distorted, generally more oval in shape, and less compact. Dispersion: dispersing is the ability of some anti-scalants to adsorb on crystals or colloidal particles and impart a high anionic charge, which tends to keep the crystals separated. The high anionic charge also separates particles from fixed anionic charges present on the membrane surface. R Crystals R Ca CO3 CO3 Ca CO3 CO3 Ca Membrane Threshold Mechanism Dispersing During the past two decades, new generations of anti-scalants (AS) have emerged commercially, in which the active ingredients are mostly proprietary mixtures of various molecular weight polycarboxylates and polyacrylates. Optimal molecular weights have been reported in the range of 1,000-3,500. It is often stated that anti-scalants adsorb onto formed crystals or associate/complex with incipient nuclei (or crystals) and that these phenomena govern the inhibition of scale formation affecting the crystal morphology. The precise mechanism of scale inhibition is not clearly understood at this time. However, it is known that in supersaturated solutions of sparingly soluble salts, a significant delay in crystal nucleation and subsequent growth is observed in response to AS treatment. This delay is referred to as the induction-time of the system, which occurs at remarkably low threshold dosages in the order of 1-10ppm. The scale inhibition capability of anti-scalants is related to chemical structure, molecular weight, active functional groups and solution ph parameters. 8

An important factor in determining the success of surface and ground water desalination is the optimization of anti-scalant treatment with respect to type and dosage. Prior to field testing or even laboratory studies on the performance of RO processes, it is important to identify the proper antiscalant to use and the dosageinduction time relationship for the expected level of supersaturation. ADDAPT Chemicals BV offers Descal 900 (Polyacrylate) and PEX-080B/PEX-106 (when neutralised) as AS. When used at threshold levels they effectively inhibit the precipitation of many scale-forming minerals and also modify the crystal morphology. Both of these properties play key roles in keeping heat exchanger or evaporator surfaces scale-free. 10. Conclusion ADDAPT Chemicals BV offers a wide range of Foam Control Agents and Antiscalants, which are suitable for different kind of industrial water treatment and desalination plants. The plant manager should forward already what kind of wastewater is treated in the plant, preferred with the rough composition of wastewater (for example if it is non-ionic, cellulose or starch based). The kind of Foam Control Agent nowadays used, gives a good indication what kind of wastewater is treated. Attached flow chart gives already an indication what kind of Foam Control Agent could be evaluated for an effective treatment and leading to an optimised biodegradation. Note FS 150N Foamstop 150N Not suitable for cationic based sewage systems; Water soluble FS 600N Foamstop 600N Water soluble CC 11 Foamstop CC 11 Mineral oil/pag based MP 21 Foamstop MP 21 Polyol based VF10N VF35N Foamstop VF 10N Foamstop VF 35N Based on Vegetable oils; biodegradable, from renewable resources, non-voc Based on Vegetable oils; biodegradable, from renewable resources, non-voc SIN 265 Foamstop SIN 265 PAG based SIN 360 Foamstop SIN 360 PAG based SL 10 Foamstop SL 10 Silicone emulsion (10%) Descal 900 Descal 900 Polyacrylate Mw. ~3500 PEX 080B Phosphate ester Oil soluble, water soluble upon neutralisation PEX 106 Phosphate ester Water soluble 9

11. Selection guide Foamstop grade Sewege type FS 150N FS 600N CC 11 MP 21 VF 10N VF 35N SIN 265 SIN 360 SL 10 Communal; Standard Communal; High detergent content Balanced active substances Industrial; High detergent content Industrial; High cellulose content Industrial; high protein level Cooling water, high Biocides level Scum deaerating Desalination Highly recommendable Recommendable Less recommendable 10

11

CONTACT INFORMATION ADDAPT Chemicals B.V. P.O. Box 6063 5700 ET Helmond The Netherlands Tel.: +31 (0)492 59 75 75 E-mail: info@addapt-chem.com http://www.addapt-chem.com Liability All recommendations for the use of our products, whether given by us in writing, oral, or to be implied from the results of tests carried out by us, are based on the current state of our knowledge. Under no circumstances shall Seller be liable for incidental, consequential or indirect damage for alleged negligence, breach of warranty, strict liability, tort or contract arising in connection with product(s). Seller s sole liability for any claims shall be Buyer s purchase price. Data and results are based on controlled lab work and must be confirmed by Buyer by testing for its intended conditions of use. The product(s) has/have not been tested for, and is/are therefore not recommended for, uses for which prolonged contact with mucous membranes, abraded skin or blood is intended, or for uses for which implantations within the human body is intended. ADDAPT Chemicals BV, 2015-09