TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

37E73A-903 & 906 INTELLI-VENT

INTELLI-VENT CONTROL INFORMATION When Used On Gas, Residential, Power Vented Water Heaters

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Thermo Top - Troubleshooting Tree

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Air Conditioning Sign-Off Sheet

Fossil fuel heating equipment


Luna 3 Comfort Troubleshooting Guide June 2008

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Air conditioning, electrical testing


Service Handbook Commercial / Residential gas water heater

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

SERVICE MANUAL. Flammable Vapor Ignition Resistant Water Heaters. Gas Water Heaters. Troubleshooting Guide and Instructions for Service

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

G670 Intermittent Pilot Ignition Controls

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

ENERGY SMART TROUBLESHOOTING GUIDE TABLE OF CONTENTS:

CARING FOR YOUR WATER HEATER

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

Model Description / Applications. Intermittent Pilot Gas Ignition Control

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

Your safety and the safety of others are very important.

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Gas Oven Repair Guide

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

SL280UHV SERIES GAS FURNACE WARNING

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

INSTALLATION & SERVICE MANUAL. Display Panel

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

SPA BUILDERS LX-10 STANDARD TROUBLESHOOTING APPROACH

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

Cambridge Electric Infared Fireplace User Manual

Oil and Coolant Circulating Heating System. Model - OCSM

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.

ELECT-19, Sensors and Gauges - Information, Troubleshooting, and Testing

INSTRUMENT PANEL Volvo 850 DESCRIPTION & OPERATION ACCESSORIES & EQUIPMENT Volvo Instrument Panels

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

7800 SERIES Relay Modules

COMMERCIAL GAS DRYER

AVR Pellet Control Board Installation/Service Instructions

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Tankless Gas Water Heaters Second Generation Indoor, Outdoor and Direct Vent Up to 199,000 BTU

Tankless. Water Heater. Troubleshooting Manual

HYDRONIC D5S/SC DIAGNOSTIC AND REPAIR MANUAL

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

APAds Air Conditioning Protection and Control System. Technical Help Frequently Asked Questions

Rinnai Tankless. Water Heater. Troubleshooting Manual

Installation Instructions

The Bradford White. Save this manual for future reference. (To be performed ONLY by qualified service providers)

PLP - TERMS AND CONDITIONS

601 International Ave. Washington, Missouri (636) (636) (FAX) M REV C

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Standard WIRED Installation Guide

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Residential Gas and Electric Water Heaters

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Service Manual. LP Gas Tankless Water Heater. Model: GSWH-1. For Recreation Vehicles

Service Manual 33 Wide Screen Fireplace with Full Feature Remote Control

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

!"" #$% "!&' ( ( ) *

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

Norcold Repair Guide Models 442, 443, 452, 453, 462, 463, 482, 483

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

TSB #: 74 Date: 9/7/2013 HOLDEN VE/WM HVAC & A/C DIAGNOSTIC HINTS

COMMERCIAL GAS DRYER

GeniSys 12V. Model Description / Applications. Advanced 12 Vdc Burner Control

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

DKG 972 Gas Burner Safety Control

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Essential Electrical Concepts

SERVICE DIAGNOSIS Modine heating & ventilating equipment

OPL BASIC. Dosing System for Professional Laundry machines. Contents

GAS SAFETY PRECAUTIONS

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

User's Instructions. Alpha HE CB25/33 and HE SY25

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

Commercial Gas Water Heater

SERVICE TIPS. Dometic REFRIGERATORS. Models. OS1927 4/96 Copyright 1996 The Dometic Corporation

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Model 201 Wiegand Touchpad Reader Installation Guide

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

THE CARE AND FEEDING OF YOUR RV IIl

Transcription:

http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html TECHNICAL SERVICE DEPARTMENT Effective October 2007, we transitioned to the White Rodgers (Intelli-Vent TM )Thermostat Control for our standard Guardian PowerVent residential gas water heaters. This change affected both natural and LP gas models. Below is the troubleshooting step for each potential error code. In the event you display the code for a flammable vapor event, please call the technical support line at the phone number above. Error 1 An open earth ground circuit to the water heater. 1. Check that the earth ground conductor is properly connected at the fuse box or breaker panel and the water heater. 2. Check that the grounding conductors on the water heater are properly connected and secure. 3. Check green grounding wire connection on side of control valve. Error 2 The self diagnostic test detected a wiring error or a high resistance to earth ground. 1. Check for proper connection of the line neutral and line hot wires. 2. Check that the appliance is securely connected to earth ground. Error 3 The pressure switch remained closed longer than 5 seconds after the call for heat began. This error code will appear within 5 seconds if the pressure switch will not open. 1. The pressure switch wiring is incorrect. 2. The pressure switch has been jumpered. 3. The pressure switch is defective (contacts inside switch permanently closed) and must be replaced. Page 1 of 8

Error 4 The pressure switch remained open longer than 5 seconds after the combustion blower energized. 1. The pressure switch wiring is incorrect or disconnected. 2. The pressure switch tubing in not connected correctly or pinched off. 3. Obstructions or restrictions in the water heater exhaust venting. Remove venting and recycle to rule out venting. If unit goes to main burner, the venting is the problem. If the code repeats, replace inducer/pressure switch. 4. The vent over-temperature switch if activated or defective. Error 5 The self-diagnostic test has detected an error in the Hot Surface Igniter circuit. 1. Check that the wiring harness Molex is connected and secure. 2. Disconnect the ignitor connector and measure the ignitor resistance with an ohmmeter between pins 1 and 2. Resistance should be between 11.5 and 18.8 ohms. 3. If the reading is incorrect, replace the Hot Surface Ignitor assembly. 4. If the above checks are good, replace the Intelli-Vent TM control. Error 6 The maximum number of ignition retries or recycles has been reached and the system is in lockout. (This means there was no flame rectification to the control to verify main burner.) 1. Check if the gas supply is off or too low to operate. 2. Check the flame sense rod to see that it is located properly and free from contamination. Reposition the flame sense rod or lightly clean with an abrasive cloth. (See last page for positioning of flame rod.) 3. The Hot Surface Ignitor may not be positioned on the burner correctly. Reposition as necessary. (See last page for proper positioning of hot surface igniter and flame probe) 4. Low voltage to the water heater. (Verify the hot surface ignitor glows by recycling power and looking thru sight glass window. If you have a glowing ignitor, then your problem is probably fuel related.) 5. Thermal Release Device is damage or missing. No oxygen in combustion chamber. 6. Inadequate fresh air to support combustion inside combustion chamber. 7. Main burner supply tube is blocked, bent or restricted; burner orifice is blocked or restricted. Page 2 of 8

Error 7 The self-diagnostic test found a problem with the gas valve driver circuit. Note: There are no further tests to conduct when the control fails one of its self-diagnostic tests. If the valve thinks there is something wrong; then the recourse is to replace the control. Error 8 The self-diagnostic test found a problem with the internal micro computer Note: There are no further tests to conduct when the control fails one of its self-diagnostic tests. If the valve thinks there is something wrong; then the recourse is to replace the control. Error 9 The self-diagnostic test found a problem with the internal circuit Note: There are no further tests to conduct when the control fails one of its self-diagnostic tests. If the valve thinks there is something wrong; then the recourse is to replace the control. Page 3 of 8

Error 10 Flame signal sensed out of proper sequence. (The flame probe sensed the presence of flame when it was not supposed to.) Error 11 High temperature thermal cut-off (ECO) switch is tripped. (This one time use device trips when the water temperature exceeds 195 0 F.) Error 12 The self diagnostic test has indicated one of the temperature adjustment buttons is stuck closed. 1. Make sure that there are no objects leaning against the front of the control 2. Lightly press and release each of the buttons once. 3. If the above actions do not clear the error, the control will continue to regulate water temperature at the last setting, but you are not able to change settings unless you replace the Intelli-Vent TM control. Error 13 The self-diagnostic test has detected that the water temperature sensor is either open or short circuited. Note: There are no further tests to conduct when the control fails one of its self-diagnostic tests. If the valve thinks there is something wrong; then the recourse is to replace the control. Page 4 of 8

Error 14 The self-diagnostic test found a problem with the Flammable Vapor Sensor. (This is not a flammable vapor event. It may be caused by disconnecting the FV sensor Molex, or the FV sensor itself. This includes both short and open electrical connections.) 1. Check all FV sensor wiring harness connections; and the connections to the back of the sensor. 2. Cycle power to the water heater off for 10 seconds and then back on. 3. If no wiring problems are found, the Flammable Vapor Sensor must be checked. a. Disconnect the FV sensor Molex and measure the resistance of the sensor between the two black wires 2 and 3. If the resistance is less than 9k OHMS or greater than 45k OHMS, then replace the sensor. b. If the FV sensor is between 9K OHMS and 45K OHMS and the code will not clear by recycling power, replace the Intelli-Vent TM control. Error 15 The control detected the presence of flammable vapors near the water heater and entered lock out. This is a permanent lockout and cannot be cleared by cycling power. Control may be reset. 1. Disconnect the FV sensor Molex and measure the resistance of the FV sensor between the two black wires 2 and 3. 2. Write down this resistance and call the technical support line at 800-432-8373 for further instructions. 3. The control is field resettable; however, we probably need to replace the FV sensor if the sensor is out of tolerance. Page 5 of 8

Flickering Lights on Control All light flicker in an erratic pattern. This condition is All light flicker in an erratic pattern. caused by an erratic or lost neutral connection. 1. Measure for 120V between the long and short slots on the wall plug. Check for loose wires inside the wall plug if needed. 2. Turn blower ON. Measure for 120V between the red and wire wires on the bottom of the control as indicated in this photo: 3. If you have 120V between the red and white wires, replace the control. 4. IF you have 120V at the wall and not at the control, then replace the blower motor. Page 6 of 8

Page 7 of 8

Flame Sensor Rod Position TECHNICAL SERVICE DEPARTMENT The table and diagrams below show the proper placement of the flame sensor rod for the Guardian PowerVent with the White Rodgers control. Flame Sensor Rod Positions (Nominal) Models "X" "Y" Natural Gas 1/2" (+)1/32" (above burner lip) Propane Gas 7/16" 0" (even with burner lip) X positioning (top view) Y positioning (side view distance from top of burner plate) Page 8 of 8