Self-Aligning Lowest Profile



Similar documents
GIVE YOUR PATIENTS THE FREEDOM TO EAT, SPEAK AND LAUGH AGAIN.

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Order of Treatment STEP-BY-STEP INSTRUCTIONS TO PLACE LOCATOR ATTACHMENTS

Tired of THE Gooey mess?

ball abutment overdenture: chairside pick-up using existing denture

NARROW DIAMETER implant

LOCATOR BAR ATTACHMENT SYSTEM

LOCATOR Implant Attachment System for XiVE, FRIALIT and ANKYLOS Implants

Ridge Reconstruction for Implant Placement

THE LOCATOR OVERDENTURE IMPLANT SYSTEM.

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

MS SA Implant - Narrow Ridge MS SA Implant - Denture. MS Implant - Provisional MS KIT

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

Milled Bar Overdentures-Protocol and Procedures

Edentulous patients. Straumann Dental Implant System

Product Catalog. ERA Mini TM Dental Implant System

Implant Parts. A Radford Heath Guide 1

Multi-unit abutment bar overdenture

ITI Small Diameter (SD) external hex 3.25 / 3.3 external hex. ITI Standard 4.8 internal non-octagon Morse taper 4.

Tired of THe Gooey mess?

Implant Bar Overdenture Utilizing Locator Attachments

Attachments And Their Use In Removable Partial Denture Fabrication

All-on-4 treatment concept with NobelSpeedy Groovy

TRI-CAM Implant System

LOCATOR ROOT ATTACHMENT SYSTEM

Prosthodontist s Perspective

Dental Updates. Excerpted Article Why Implant Screws Loosen Part 1. Richard Erickson, MS, DDS

ERA. Attachment Systems. A SNAP to Use and Maintain

Full Mouth Restoration with Screw-Retained Zirconia Bridges

Gl GinGival level implant

PRACTICE MARKETING PROGRAM

There When You Need Them: 10 Principles of Successful RPD Treatment

SCD Case Study. Treatment Considerations for Implant Rehabilitation

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

ADA Insurance Codes for Laboratory Procedures:

Improving Esthetics with Sequential Treatment Planning and Implant-Retained Dentures

2016 Buy Up Dental Care Plan Procedure List

procedures & products NOBELESTHETICS including Procera

Restorative Guidelines

ANKYLOS. Syncone Concept. The Paradigm For Implant Supported Dentures. Redefining Success In Implant Dentistry

Restoration of Endodontically Treated Teeth

The IMZ Implant System

Accelerated Patient Rehabilitation

Restorative Manual Impression Transfer System

Prosthetic Manual. Implant System. Contact Us: Smarter thinking. Simpler design. Phone: Fax:

More than a fixed rehabilitation.

Regular C/X Prosthetics. Prosthetics

Standard Internal Hex

MINI IMPLANTS FOR LOWER DENTURE STABLIZATION

screw-retained crown using a PEEK temporary abutment

A New Beginning with Dental Implants. A Guide to Understanding Your Treatment Options


GINGIVAL LEVEL implant

The Most Frequently Asked Questions About Dental Implants... A Consumer s Guide to Understanding Implant Treatment

prosthetic technique manual

Implants in your Laboratory: Abutment Design

Washington State Dental Association s 2015 Pacific Northwest Dental Conference. Presents

INTRODUCTION. most popular stud attachment available to the dental profession to increase the retention of implant complete

Tooth Replacement Options

BICON DENTAL IMPLANTS

DENT IMPLANT restoring qualit S: of LIfE

Precision and Semi- Precision Attachments Where? When? Why? George E. Bambara, MS, DMD FACD, FICD

Nobel Clinician - Quick Guide

Tooth Supported Overdentures

Like natural teeth. Treatment with dental implants is a safe, reliable and well-proven solution for permanently replacing one or more missing teeth.

Clinical and Laboratory Procedures for Fixed Margin Implant Abutments

IMPLANT DENTISTRY CLINICAL SYLLABUS

Encode Restorative System Procedure & Laboratory Manual

One Abutment - One Time

DESS. Screws. Tijuana Ventas: (664) /95 For all major implant systems!!

About DENTSPLY Implants

Don t Let Life Pass You By Because Of Oral Bone Loss

The SKY Locator family

Retention of maxillary implant overdenture bars of different designs

Supervisors: Dr. Farhan Raza Khan

screw-retained single crowns using custom-cast abutments

Flexible dentures an alternate for rigid dentures? Volume 1 Issue 1

Table of Contents WARNING SYMBOLS AND DEFINITIONS

Optimizing Referral Team Collaboration Using Dynamic Visual Communication Software

Determine the desired location fixture and center the coaxial cord location to the electrical box.

PATIENT INFORM CONSENT for IMPLANT RESTORATION Rev

All Suture Anchor. with IntelliBraid Technology

The Mandibular Two-Implant Overdenture First-Choice. Standard of Care for the Edentulous Denture Patient

Understanding Dental Implants

Smile Confidently With DIEM 2. Immediate Full Arch Rehabilitation

Implant Assisted Removable Prosthodontics

Ideal treatment of the impaired

Procedures & Products. NobelEsthetics

What is a dental implant?

Dr. Little received his doctorate degree in dentistry from UT Health at San Antonio Dental

March 20, Dear Mr. Chen:

Owner s Manual Read and keep this manual. Patents World Wide

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Dental Implants. Change Your Life & Smile with. Kingston Kitchener Newmarket Oshawa Scarborough Toronto Waterloo

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

PROSTHETICS. Crown and bridge restorations with the synocta prosthetic system.

CHAPTER 12 SURVEY LINES. portion of the tooth is undercut to the path of placement of the denture. DEFINITIONS

Transcription:

Self-Aligning Lowest Profile * Lowest Profile * Self-Aligning * Dual Retention * Long Lasting * Choice of Retention * Easy Solution for Divergence * Money-Back Guarantee *LOCATOR Patent No. 6,030,219 SELF ALIGNING INCREDIBLE DURABILITY The LOCATOR Implant Attachment features a denture component with a skirt that easily locates the mating implant abutment. This self-aligning ability of the attachment aids the patient in positioning their prosthesis in a similar manner as a guide plane created by a milled bar. The implant retained overdenture can be properly seated without damage to the attachment components. This is especially important for a patient lacking anatomical structures necessary to orient their denture due to a severely resorbed mandibular ridge. Clinical use has proven the ability of the LOCATOR Implant Attachment to correct patient problems with inserting their implant retained overdenture in as little as one appointment. The unique Dual Retention innovation provides the LOCATOR Implant Attachment with more than twice the amount of retention surface area available with other attachments. A combination of inside and outside retention ensures long lasting performance. Delsen Testing Laboratories was contracted to measure retention of the LOCATOR Implant Attachment compared to the Stern ERA* Implant Attachment during 60,000 cycles of function. The chart below shows the number of cycles of attachment function for the retention of both attachments to fall below 0.5 pounds. This independent laboratory test clearly demonstrates the incredible wear resistance of the LOCATOR attachment with its patented Dual Retention design. Self-locating design allows a patient to easily seat their overdenture.

*ERA is a trademark of Sterngold-Implamed. Photographs courtesy of Dr. Allen Schneider and Paul Zuest. LOWEST HEIGHT LOCATOR IMPLANT ATTACHMENT The LOCATOR Implant Attachment is designed to reduce the height of abutment restoration on all brands of endosseous implants. The LOCATOR Abutment has an internal drive design. A special LOCATOR Abutment Driver fits into the abutment. 3.17mm LOCATOR 4.85mm ERA 5.82mm Dal-Ro 6.14mm O-Ring 6.22mm EDS With a total attachment height (male plus abutment) of only 3.17mm for an externally hexed implant, the LOCATOR saves a minimum of 1.68mm to 3.05mm of inter-occlusal space compared to other implant overdenture attachments. USE WITH DIVERGENT IMPLANTS The LOCATOR Abutment Driver (which is the third part of the Core Tool) is used to thread the abutment into the implant. The LOCATOR system allows restoration of a nonparallel implant with angulation of up to 20 degrees (equal to 40 degrees of total divergence between two implants).

A torque wrench will fit into the backside of the driver if 20Ncm of torque is desired. Utilizing the existing LOCATOR Abutment, the white nylon Replacement Male is used to restore a nonparallel implant with up to 10 degrees of angulation. The Extended Range green nylon Replacement Male can accommodate an angled implant between 10 and 20 degrees. EASY TO CHANGE The LOCATOR Implant Attachment system features a Core Tool that contains three tools in one, for easy replacement of the LOCATOR male component, and abutment insertion. The curved Male Removal Tool portion has a hook on the end of it to catch and pull the nylon male liner out of the permanent metal housing. The middle section is the Male Seating Tool which is used to seat a replacement male into the metal cap. The third part of this handy tool is the LOCATOR Abutment Driver. CHANGE MALES IN 30 SECONDS FLAT USING A HAND TOOL WHAT CLINICIANS REPORT ABOUT THE LOCATOR "The patient was waiting for me on my doorstep and crying out of frustration. I changed his attachment to a LOCATOR and this is the first time he can easily snap in his own denture. He couldn t be happier, and neither could I." Jeff Kosoris, D.D.S. Waxahachie, TX 6 Month Followup: "This case was the proverbial case from hell until the LOCATORS. The case has been trouble free and the patient very satisfied. There is no way I can thank you enough for solving the problem I had with this case." Jeff Kosoris, D.D.S. Waxahachie, TX CORE TOOL "The patient presented to our office with a chief complaint of not being able to retain his lower denture. We placed four LOCATOR attachments into a newly constructed denture. The results have been phenomenal. The denture is extremely secure. The patient is extremely pleased with the results." Laurence C. Breiterman, D.M.D. Wayne, NJ "I removed the attachment from the denture and directly cold cured a LOCATOR in place in the mouth. It fit excellently after directly placing in the mouth. The patient was extremely satisfied." Gary J. Blanchette, D.D.S. Sulphur, LA

PRY-OUT "The LOCATOR overdenture attachment system provides the method of choice for fabricating implant and root retained overdentures. It is well designed, durable, and very simple to use. Best of all, placement is extremely easy for patients as they can literally bite them into place." Richard A. Moselle, D.D.S. Culver City, CA SNAP-IN THE LOCATOR MONEY-BACK GUARANTEE We re so certain that you and your patient will be pleased with the LOCATOR Implant Attachment that we offer this simple guarantee: If you are not satisfied with any LOCATOR attachment within one year of purchase, we will refund your purchase price. LOCATOR IMPLANT ATTACHMENT Available to fit all major implant systems, with abutment tissue cuff heights ranging from 0mm to 4mm.

Zest Anchors, Inc. 1.800.262.2310 2061 Wineridge Place, #100 Escondido, CA 92029 Tel: 760.743.7744 Fax: 760.743-7975 file:///c /ChristopherCompany/Zest/locator_abutments/indexpdf.htm (5 of 5) [8/22/2002 1:12:19 AM]