D. FREQUENTLY ASKED QUESTIONS



Similar documents
VI. FREQUENTLY ASKED QUESTIONS CONCERNING BREAST IMAGING AUDITS

Q: What differentiates a diagnostic from a screening mammography procedure?

Guideline for the Imaging of Patients Presenting with Breast Symptoms incorporating the guideline for the use of MRI in breast cancer

III. REPORTING SYSTEM

Harlem Hospital Center Integrated Radiology Residency Program Mammography Educational goals and objectives

ACR BI-RADS ATLAS MAMMOGRAPHY MAMMOGRAPHY II. REPORTING SYSTEM. American College of Radiology 121

Medicare Part B. Mammograms - Updated Billing Guide for Screening and Diagnostic Tests

Sustaining a High-Quality Breast MRI Practice

MAMMOGRAPHY GOALS AND OBJECTIVES

Nicole Kounalakis, MD

Infrared Thermography Not a Useful Breast Cancer Screening Tool

Breast Ultrasound: Benign vs. Malignant Lesions

BREAST IMAGING. Developed by the Ad Hoc Committee on Resident and Fellow Education of the Society of Breast Imaging

Local Coverage Determination (LCD): Screening and Diagnostic Mammography (L29328)

Breast Imaging Made Brief and Simple. Jane Clayton MD Associate Professor Department of Radiology LSUHSC New Orleans, LA

Rotation Specific Goals & Objectives: University Health Network-Princess Margaret Hospital/ Sunnybrook Breast/Melanoma

Sonographic Evaluation of Isolated Abnormal Axillary Lymph Nodes Identified on Mammograms

Recommendations for cross-sectional imaging in cancer management, Second edition

Common Breast Complaints:

Provider Reimbursement for Women's Cancer Screening Program

OBJECTIVES By the end of this segment, the community participant will be able to:

Post-PET Restaging Cancer Form National Oncologic PET Registry

Breast Cancer: from bedside and grossing room to diagnoses and beyond. Adriana Corben, M.D.

Hologic Selenia Dimensions C-View Software Module. October 24, 2012

MQSA, FDA Regulations, and Inspections

Radiology Physician Performance Measurement Set

Stereotactic Breast Biopsy

Mammography. What is Mammography?

2011 Radiology Diagnosis Coding Update Questions and Answers

Office Visits. Breast

Examples of good screening tests include: mammography for breast cancer screening and Pap smears for cervical cancer screening.

Variability and Accuracy in Mammographic Interpretation Using the American College of Radiology Breast Imaging Reporting and Data System

Automated Breast Volume Scanning 3D Ultrasound of the Breast

Breast Cancer Screening

Evaluation and Management of the Breast Mass. Gary Dunnington,, M.D. Department of Surgery Internal Medicine Ambulatory Conference December 4, 2003

Mammography Education, Inc.

A Guide to Breast Imaging: The Latest Technology for Screening and Detecting Breast Cancer

Sage Screening Program. Provider Manual

Integumentary System Individual Exercises

What is DCIS? Contents. The breasts

Breast Implants: Local Complications and Adverse Outcomes

Second look ultrasound examination for breast lesions: MRI and pathologic correlation

Changes in Breast Cancer Reports After Second Opinion. Dr. Vicente Marco Department of Pathology Hospital Quiron Barcelona. Spain

FRIEND TO FRIEND CPT CODES Diagnostic digital breast tomosynthesis, unilateral (list separately in addition to code for primary procedure)

Table of Contents: Chapter 1: Screening for breast cancer in asymptomatic patients by Chris Comstock, MD and Marie Tartar, MD

American College of Radiology Mammography Accreditation Program

How To Write A Draft Report On Breast Cancer Screening

SUBJECT: MANAGEMENT OF BREAST EFFECTIVE DATE: 12/16/99 IMPLANTS REVISED DATE:

Driving Forces in Health Care:

CMS Limitations Guide Mammograms and Bone Density Radiology Services

Alaska Breast & Cervical Health Partnership. Healthy Women, Healthy Alaska Through Early Detection

Use of the American College of Radiology BI-RADS to Report on the Mammographic Evaluation of Women with Signs and Symptoms of Breast Disease 1

Mammograms & Breast Health. An Information Guide for Women U.S. DEPARTMENT OF HEALTH AND HUMAN SERVICES. Centers for Disease Control and Prevention

How To Be A Breast Consultant Radiographer

Breast Density Legislation: Implications for primary care providers

Surgical guidelines for the management of breast cancer

Breast Implants and Reconstruction

Measure #405: Appropriate Follow-up Imaging for Incidental Abdominal Lesions National Quality Strategy Domain: Effective Clinical Care

WHAT S WRONG WITH MY GALL BLADDER? GALL BLADDER POLYPS

Radiology Management Program

Disease/Illness GUIDE TO ASBESTOS LUNG CANCER. What Is Asbestos Lung Cancer? Telephone

Certification protocol for breast screening and breast diagnostic services

IAC Ch 41, p.1. Procedure means a stereotactically guided breast biopsy performed on a patient for diagnostic purposes.

Brain Cancer. This reference summary will help you understand how brain tumors are diagnosed and what options are available to treat them.

Breast Cancer. Sometimes cells keep dividing and growing without normal controls, causing an abnormal growth called a tumor.

The American College of Radiology Breast Ultrasound Accreditation Program: Frequently Asked Questions

Patterns of nodal spread in thoracic malignancies

Phyllodes tumours: borderline malignant and malignant

Personalized Breast Screening Service

U.S. Bureau of Labor Statistics. Radiology Tech

Patient Prep Information

Understanding. Breast Changes. National Cancer Institute. A Health Guide for Women. National Institutes of Health

Coding Companion for Radiology. A comprehensive illustrated guide to coding and reimbursement

Follow-up care plan after treatment for breast cancer. A guide for General Practitioners

Breast cancer close to the nipple: Does this carry a higher risk ofaxillary node metastasesupon diagnosis?

How To Compare Mammography To A 3D System

Cystic Neoplasms of the Pancreas: A multidisciplinary approach to the prevention and early detection of invasive pancreatic cancer.

CRICO Breast Care Management Algorithm

Helen Joseph Breast Care Clinic - Johannesburg, South Africa

Participate in Cancer Screening

PET/CT in Breast Cancer

Objectives. Mylene T. Truong, MD. Malignant Pleural Mesothelioma Background

Pleural and Pericardial fluids a one year analysis

Hereditary Multifocal Breast Cancer. Farin Amersi M.D., F.A.C.S Division of Surgical Oncology Department of Surgery Cedar Sinai Medical Center

ALABAMA BREAST AND CERVICAL CANCER EARLY DETECTION PROGRAM PROVIDER MANUAL

Guidance for Industry

Explanation of your PAP smear

How To Decide If You Should Get A Mammogram

GENERAL CODING. When you review old cases that were coded to unknown, make corrections based on guidelines in effect at the time of diagnosis.

The best treatment Your guide to breast cancer treatment in Scotland

Stephanie K. Patterson, MD,* Mark A. Helvie, MD,* Khadija Aziz, MD, and Alexis V. Nees, MD*

Breast Cancer. CSC Cancer Experience Registry Member, breast cancer

Santa Maria Annunziata Hospital / Azienda Sanitaria di Firenze

Azienda Ospedale Annunziata Cosenza - Cosenza, Italy

Ductal carcinoma in situ (DCIS)

Patient sample criteria for the OPEIR Measures Group are all patients regardless of age, that have a specific CT procedure performed:

Breast MRI Quality Control

Introduction Breast cancer is cancer that starts in the cells of the breast. Breast cancer happens mainly in women. But men can get it too.

Transcription:

ACR BI-RADS ATLAS D. FREQUENTLY ASKED QUESTIONS 1. Under MQSA, is it necessary to include a numeric assessment code (i.e., 0, 1, 2, 3, 4, 5, or 6) in addition to the assessment category in all mammography reports? No. FDA regulations require only that each mammography report include the text corresponding to the overall assessment category, not the numeric code. These categories are Incomplete: Need Additional Imaging Evaluation, Negative, Benign, Probably Benign, Suspicious, Highly Suggestive of Malignancy, and Known Biopsy-Proven Cancer. The FDA requires that the assessment category be written verbatim as described in their regulations (limited flexibility is allowed, using equivalent wording as detailed in Table 8 below). Use of any wording not specifically listed in the table would be in violation of FDA regulations. Also, the FDA has approved an alternative standard to allow the assessment category Post Procedure Mammograms for Marker Placement. Although the ACR encourages the use of numeric codes along with the assessment category text, there are no requirements that the codes be assigned to their respective assessments. Table 8. FDA-Approved Equivalent Wording for BI-RADS Assessment Categories BI-RADS Assessment Category Incomplete Need Additional Imaging Evaluation and/or Prior Mammograms for Comparison BI-RADS Numeric Code FDA Approved Equivalent Wording 0 Incomplete: Needs Additional Imaging Evaluation Incomplete: Additional Imaging Evaluation Needed Incomplete: Need Additional Imaging Evaluation Comparison with Prior Studies Incomplete: Need Additional Imaging Evaluation and/or Prior Mammograms for Comparison Incomplete: Need Prior Mammograms for Comparison Need Additional Imaging Evaluation (The term incomplete can be inferred in this example as this is the only BI-RADS assessment category.) Incomplete Mammogram: Need Additional Imaging Evaluation Negative 1 Negative Mammogram Benign 2 Benign Finding Benign Findings Benign Abnormality Benign Abnormalities Benign Mammogram Probably Benign 3 Probaby Benign Finding Probably Benign Findings Probably Benign Abnormality Probably Benign Abnormalities Probably Benign Short Interval Follow-up Suggested Probably Benign Finding Short Interval Follow-up Suggested Probably Benign Mammogram American College of Radiology 159

2013 BI-RADS Assessment Category BI-RADS Numeric Code FDA Approved Equivalent Wording Suspicious 4 Suspicious Finding Suspicious Findings Suspicious Abnormality Suspicious Abnormalities Suspicious for Malignancy Suspicious Finding Biopsy Should Be Considered Suspicious Abnormality Biopsy Should Be Considered Suspicious Mammogram Highly Suggestive of Malignancy Known Biopsy-Proven Malignancy 5 Highly Suggestive for Malignancy Highly Suggestive of Malignancy Appropriate Action Should Be Taken 6 Known Biopsy-Proven Cancer Known Malignancy Known Cancer 2. Is there a new numeric code in BI-RADS for Post Procedure Mammograms for Marker Placement? No. There is no numeric code for the FDA-approved alternative standard for Post Procedure Mammograms for Marker Placement. This is not even a BI-RADS final assessment category. This assessment may be used only for postprocedure mammograms obtained for the purpose of confirming the deployment and position of breast tissue markers, which typically have been placed at the time of core biopsy. In addition, this assessment should be excluded from auditing. Note that there is no FDA-approved equivalent wording for this assessment category other than Post Procedure Mammograms for Marker Placement. 3. In my practice we commonly issue addenda and/or comparison reports after initial mammography reports have been issued. Are we required to provide a final assessment category with each of these reports? Must we also send the addendum or comparison report to the referring health care provider and a letter to the patient, even if there is no change in the final assessment category or recommended course of action? Yes, to both questions. FDA regulations require that the report issued after additional mammography (i.e., repeat, spot-compression, magnification, other additional views) or following comparison with prior mammography examinations must provide a final assessment category for the case. A report must be communicated to the referring health care provider or the self-referred patient. In addition, a lay summary of the addendum or comparison report must be provided to the patient, even if there is no change in the final assessment category or recommended course of action. For the specific case in which there is no significant change in a comparison report, a simple statement that the comparison has been performed and that there is no overall change (ensuring to include the unchanged final assessment) would satisfy the requirement, accompanied by a comparison lay summary informing the patient of that fact. For the specific case in which an addendum report is issued that merely states that the referring health care provider has been notified of the results of the patient s examination, then the addendum lay summary may be a simple statement informing the patient of that fact. 4. My practice uses the BI-RADS category 4 subdivisions (4A low suspicion for malignancy, 4B moderate suspicion for malignancy, 4C high suspicion for malignancy). May our reports use these subdivisions as assessment categories instead of the category 4 assessment (suspicious)? 160 American College of Radiology

ACR BI-RADS ATLAS No. While you have the option of using one of the three subdivisions of category 4 in addition to a final assessment of Suspicious, the FDA will not allow you to use the subcategories instead of the Suspicious assessment category in the mammography report. 5. Do mammography examinations performed on men require a BI-RADS final assessment and/or numeric code? Yes. All mammography examinations, regardless of the patient s gender, are required to have a final assessment category (not a numeric code) in the mammography report. However, management recommendations may differ from those made for women because annual screening mammography is not usually appropriate for men. 6. Under the Centers for Medicare and Medicaid Services (CMS) guidelines, we may now charge for screening and diagnostic mammography examinations done on the same patient on the same day. May we combine the two examinations into one report or must we issue two separate reports? The mammography facility has the option of issuing either separate or combined reports. (You may want to check with your billing office; some third-party payers may require individual reports.) If two reports are issued, each must contain its own overall final assessment. The facility may report both examinations on the same piece of paper. If the facility decides to issue a single combined report, the facility needs to be aware of the following: 1. A single combined report must contain a single overall final assessment. 2. The combined report should make it clear to the referring clinician that it is combining the results of the screening and diagnostic studies. This is also important if questions ever arise about whether the examinations were billed correctly. 3. It is critical to understand that issuing a single report with a single final assessment will skew the facility s audit results, unless (recommended) the examination is audited as both screening category 0 and diagnostic, using the final assessment category rendered. 4. Although some computerized reporting systems may consider this a single examination (rather than two), FDA would still allow the facility to count both examinations toward meeting the continuing experience requirement of the interpreting physician. 7. If the final assessment of a screening mammography examination is Incomplete (BI-RADS category 0) and the woman then undergoes additional imaging evaluation, does the FDA require the mammography facility to revise or amend the original report if, as a result of the additional imaging, the assessment is changed to any of the final assessment categories? First, for auditing purposes, the original screening assessment must remain category 0. However, if the additional imaging includes mammography (and therefore is covered under MQSA), the facility performing these additional mammographic views also must issue a report (either separately or as an addendum to the original mammography report) that reflects the final assessment. The BI-RADS Atlas provides further recommendations on this topic. When more than one type of [diagnostic] examination is performed concurrently (on the same day), it is preferable that the examinations be reported together, with the findings for each examination described in a separate paragraph, with separate assessments for each examination followed by an overall assessment and management recommendations for the combined examinations. American College of Radiology 161

2013 8. A screening mammography examination received an Incomplete (BI-RADS category 0) assessment due to an asymmetry. The subsequent diagnostic mammography examination is also assessed as BI-RADS category 0, recommending additional US examination. A US examination then is performed showing no abnormal findings, but I want to further evaluate this patient with MRI, which occasionally depicts a cancer not seen at either mammography or US. Is it appropriate to also assess the US examination as BI-RADS category 0, recommend additional MRI examination? This question involves two non-recommended uses of BI-RADS category 0. First, with few uncommon exceptions, category 0 should not be used for diagnostic mammography examinations. Therefore, if diagnostic mammography is performed concurrently with US, an overall BI-RADS assessment category should be given (rather than a category 0 assessment for the mammography followed by a final assessment for the US). The overall assessment would depend on the mammographic and sonographic findings and whether these are or are not described in the diagnostic breast imaging report. Refer to the following examples. If no findings are described in either the mammography or US portions of a combined report, the appropriate overall assessment is negative (BI-RADS category 1). If one or more specific benign findings are described in either the mammography or US portions of a combined report, the appropriate overall assessment is benign (BI-RADS category 2). If diagnostic mammography depicts a focal asymmetry with no associated mass, calcifications, or architectural distortion; if there is no sonographic or palpable correlate to the mammographic finding; and if there are no prior mammography examinations available for comparison, it may be appropriate to render a probably benign (BI-RADS category 3) assessment. If diagnostic mammography indicates the presence of a suspicious abnormality despite absence of a sonographic correlate (or vice versa), the appropriate overall assessment is suspicious (BI-RADS category 4). Second, BI-RADS category 0 should not be used for diagnostic breast imaging findings that warrant further evaluation with MRI. Rather, the radiologist should issue a final assessment for the combined diagnostic mammography and US examinations in a report that is made before the MRI is performed. If further evaluation with MRI is warranted, the radiologist should incorporate this recommendation into the patient management recommendations in the combined mammography/us report. This provides the following advantages: If the recommended MRI examination is not performed, the combined diagnostic breast imaging report will stand as issued. If MRI is performed as recommended, it would not be necessary to re-interpret the mammography and US examinations. A negative or benign MRI assessment would sustain a similar assessment made at diagnostic mammography and US. If the MRI examination shows more abnormal findings than those identified at mammography and US, the MRI assessment would supersede that made for mammography and US. Also note that breast MRI is not appropriate follow-up in many situations, including: Instead of biopsy of a suspicious finding at mammography and/or US. As an alternative to short-interval follow-up of probably benign findings at mammography and/or US. 162 American College of Radiology

ACR BI-RADS ATLAS To further evaluate findings that should be recognized as benign at mammography and/ or US, such as gynecomastia or multiple bilateral, mostly circumscribed masses. Also most lymph nodes and fat necrosis may be characterized as benign at mammography and/or US. MRI is rarely helpful in further evaluation of possible architectural distortion that is too vague to target for stereotactic or sonographic biopsy. 9. Axillary adenopathy is seen at screening mammography with no suspicious findings in the breasts. What should the BI-RADS final assessment be? In the absence of a known infectious or inflammatory cause, isolated unilateral axillary adenopathy should receive a suspicious (BI-RADS category 4) assessment. Unilateral axillary adenopathy suggests occult breast carcinoma or, much less commonly, lymphoma, metastatic melanoma, ovarian cancer, or other metastatic cancer. Consequently, a careful search of the ipsilateral breast images is warranted. Bilateral axillary US should be performed to confirm that the finding is asymmetric/unilateral. Clinical evaluation for infection or inflammation in the ipsilateral breast, axilla, arm, and hand is recommended at the time of US, as mastitis, breast abscess, an infected skin lesion, and cat-scratch fever are all potential sources of benign unilateral axillary adenopathy. If a benign cause is elucidated, a benign (BI-RADS category 2) assessment would be appropriate. In the absence of a known infectious or inflammatory source, a suspicious (BI-RADS category 4) assessment would be appropriate, with the intent to biopsy after further evaluation and review of clinical history. It is then appropriate to proceed with US-guided fine-needle aspiration (FNA) or core biopsy of the axillary adenopathy, and it may be advisable to perform ipsilateral whole-breast US at that visit to search for an occult primary breast carcinoma. Bilateral axillary adenopathy would be assessed as benign (BI-RADS category 2) in some situations and as suspicious (BI-RADS category 4) in others. Bilateral axillary adenopathy is frequently reactive/infectious in origin, such as with inflammatory conditions (sarcoidosis, systemic lupus erythematosis, psoriasis, etc.) and HIV. In such situations, the appropriate assessment is benign (BI-RADS category 2). Patients with known lymphoma or leukemia may also have bilateral axillary adenopathy. In this situation, the BI-RADS assessment should be based on findings in the breasts themselves, but the report also should indicate the presence of adenopathy and the known underlying disease. For example, a report might indicate a negative or benign assessment, followed by with bilateral axillary adenopathy presumed due to known lymphoma. It may be helpful to contact the referring health care provider or review the electronic medical record to clarify whether or not there is such a history before issuing a final report. If there is no known explanation for bilateral adenopathy, and particularly if it is new, then it may be a sign of lymphoma/leukemia, and a suspicious (BI-RADS category 4) assessment is warranted, with a recommendation for US-guided FNA or core biopsy. Note that ideally, biopsy specimens should be kept in saline or RPMI 1640 if lymphoma is suspected, to facilitate fluorescence-activated cell sorting. 10. Are there BI-RADS assessment categories and management recommendations available for breast PET scans and dedicated breast gamma camera imaging examinations? Are there plans to include these in the BI-RADS Atlas in the future? No. Because these breast imaging modalities are so new, the BI-RADS Atlas does not have assessment categories and management recommendations for breast PET scans and dedicated breast gamma camera imaging examinations at this time. The atlas will be updated with new modalities as they become more established and widely available. In the interim, the same assessment categories for mammography, US and MRI may be used for these and other new-modality examinations, so long as recommendations for patient management are clearly stated in the imaging report. American College of Radiology 163