The 2009 RCSC MARKETING PUBLICATIONS REDESIGN TITLE CHANGE. Specification for Structural Joints Using High-Strength Bolts. Why use RCSC Specification?



Similar documents
Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the A325 structural bolt. Rev.

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

CSA S16-09 Design of Steel Structures Canada

STATEMENT OF WORK (SOW) On-Call Certified Welding Inspections and Nondestructive Testing

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Conceptual Design of Buildings (Course unit code 1C2)

Section 10.9 STRUCTURAL STEEL AND MISCELLANEOUS METAL COMPONENTS

Preformed Metal Roofing and Siding

Discipline: Structural Issued

GENERAL WELDING & FABRICATING, INC. 991 Maple Road Elma, New York 14059

SPECIAL INSPECTION AND TESTING AGREEMENT INTERNATIONAL BUILDING CODE

APPENDIX H DESIGN CRITERIA FOR NCHRP PROJECT NEW BRIDGE DESIGNS

ABOUT CWB CERTIFICATION/ QUALIFICATION The work CWB does on behalf of our clients can be divided into five main categories:

SERIES NG 1800 STRUCTURAL STEELWORK

Code of Standard Practice for Steel Buildings and Bridges

Code of Standard Practice for Timber Frame Structures

Bolting Galvanized Steel

1.02 SYSTEM DESCRIPTION

Hilti HIT-V and HAS Threaded Rod and Hilti HIT-Z Anchor Rod

SECTION WINDOW WASHING SYSTEMS

ICC-ES Evaluation Report

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

High Strain Dynamic Load Testing of Drilled Shafts

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Manufacturing, Supply & Quality Plan for Tower Bolts. SL Tower Bolt Market Penetration

Challenging Skew: Higgins Road Steel I-Girder Bridge over I-90 OTEC October 27, 2015 Session 26

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

DWG 001. Blueprint Reading. Line Standards Drawing Symbols. Instructor Guide

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

American National, Unified Screw Threads

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

Working Drawing and Assemblies. Chapter 10

Nueva Edición del libro clásico para estudiantes de grado.

Mechanical Installation

COLUMN-FREE OFFICE SPACE RISES IN CHICAGO S LOOP

STANDARD SPECIFICATIONS

Tension Development and Lap Splice Lengths of Reinforcing Bars under ACI

TRANS-05, Torque Tube Removal, Rebuilding, and Installation

James M. Pleasants Company

Steel Connections- Parametric Design and Detailing

STRUCTURAL STEEL DESIGN AND CONSTRUCTION. Gary S. Berman, PE GREYHAWK North America, LLC. GREYHAWK North America, LLC

CLARK COUNTY DEPARTMENT OF BUILDING & FIRE PREVENTION 4701 W. Russell Road Las Vegas, NV (702) Fax (702)

Construction Laborer Dies after Falling off Collapsed Precast Concrete Floor Slab

TOP RUNNING SINGLE GIRDER BRIDGE CRANE

Screw Thread Design. Rev

Structural Steel Connections STEEL S T E E L STRUCTURE OF THE EVERYDAY : STRUCTURE OF THE EVERYDAY. American Institute of Steel Construction

Complex Sloping Steel Roof Issues

PART 1 GENERAL 1.1 SECTION INCLUDES

Chapter 3 - Structural Design

Hilti, Inc South 122 nd East Avenue Tulsa, OK

INSTALLATION. General. Important Note. Design. Transport

Embedded Parts Introduction - Anchors

Rules for Construction of Overhead and Gantry Cranes (Top Running Bridge, Multiple Girder)

DESCRIPTION. Stud Bolts for Pressure-Temperature Piping 2-1. General Purpose End-to-End Studs 2-2. Tap End Stud Bolts 2-3. Double End Stud Bolts 2-4

A. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.

ENG-10, Camshaft (Timing) Belt and Balance Shaft Belt Tension - Checking and Adjusting

Copies of this document shall be classified either as Controlled or Uncontrolled, and shall be identified as such on the cover sheet.

CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS

Steel Bridge Design E90 Project Proposal

CITY OF LOS ANGELES CALIFORNIA

SPECIFICATIONS, LOADS, AND METHODS OF DESIGN

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: HUBBELL POWER SYSTEMS, INC.

Let s look at an example of where grade 5 and grade 8 bolts are subjected to single shear loads (winch plate reference).

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination

Residential Prototype III. Multi-Story. The Multi-Story. Your connection to ideas + answers. Prepared by: AISC Steel Solutions Center

CHAPTER J DESIGN OF CONNECTIONS

IKG Bar Grating: Anchoring

INSTRUCTIONS FOR USE

SECTION GUARDRAILS

Alternative Steel Materials to BS 5950

ACCREDITATION CRITERIA FOR FABRICATOR INSPECTION PROGRAMS FOR STRUCTURAL STEEL. AC172 February 2015 (Effective April 1, 2015)

Submittal Information

Calvert USA, Inc. Attic Stairs

How To Make A Thomas Bunk Bed

QUALITY ASSURANCE FOR STRUCTURAL ENGINEERING FIRMS

Aviation Hangars & Cargo Facilities

AN EXPLANATION OF JOINT DIAGRAMS

STRUCTURAL TESTS AND SPECIAL INSPECTIONS

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig some of the trusses that are used in steel bridges

Bolting: Attachment Of The Mudsill To The Foundation

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

Overhang Bracket Loading. Deck Issues: Design Perspective

SHARP. Focus. AESS serves as the focal point of a small eye-care office in Austin. BY BRIAN SAYRE, P.E., AND K. MARK MERRYMAN, P.E.

San Francisco Oakland Bay Bridge SELF-ANCHORED SUSPENSION (SAS) SPAN

INSTALLATION INSTRUCTIONS COMPETITION SERIES COILOVER SUSPENSION SYSTEM 03+ Scion xb

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Technical Report Example (1) Chartered (CEng) Membership

Scheduling Estimating Module

SERIES 1800 STRUCTURAL STEELWORK

PERFORMANCE TEST REPORT. Rendered to: FORMTECH ENTERPRISES, INC. SERIES/MODEL: Truline PRODUCT TYPE: PVC Seawall

STANDARD FOR NON-FIRE RATED ROLLING DOORS

System. Stability. Security. Integrity. 150 Helical Anchor

The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.

Transcription:

14 th Edition Steel Construction Manual Introduction to the new AISC Publications Specification for Structural Joints using High-Strength Bolts (AISC 348-09) Code of Standard Practice (AISC 303-10) Specification for Structural Steel Buildings (AISC 360-10) Ohio Structural Engineers Association (SEAoO) Cincinnati, OH February 9, 2011 Jie Zuo AISC Staff Engineer Part 16.1 (AISC 360-10) Specification for Structural Steel Buildings Part 16.2 (AISC 348-09) Specification for Structural Joints using High-Strength Bolts Part 16.3 (AISC 303-10) Code of Standard Practice Louis F. Geschwindner Seminar 2010 Specification and 14 th Edition Manual Full day seminar = 0.80 CEU / 8 PDH Purchase the Manual for $100 (a $350 value!) Design Examples illustrate provisions of the Manual and the Specification Cleveland, OH on February 23, 2012 Columbus, OH on April 5, 2012 For more information http://www.aisc.org/seminars The 2009 RCSC Specification for Structural Joints Using High-Strength Bolts AISC 348-09 TITLE CHANGE 2004: Specification for Structural Joints Using ASTM A325 or A490 Bolts 2009: Specification for Structural Joints Using High-Strength Bolts Why use RCSC Specification? Design, installation, and inspection of bolted joints There are sections in RCSC Specification that are not reproduced in the AISC Specification 1

TC bolts HIGHLIGHTS Coatings for A490 bolts Hot-Dip Galvanizing Thermal cutting of holes Snug tight definition New ASTM Provisions TC Bolts ASTM F1852 A325 strength level TC bolt ASTM F2280 A490 strength level TC bolt Treated the same as A325 and A490 bolts except they are Tension Controlled (TC) bolts Coatings for A490 Bolts ASTM F1136 Does not have hydrogen trapping conditions Zinc/Aluminum coating Dacromet is a common product used Hot-Dip Galvanizing for threaded parts ASTM F2329 replaces A153 A153 is still applicable for structural shapes Mechanical Galvanizing is still based upon ASTM B695 Thermal cutting of holes Bolt Shear Strength Consistent with what was done in the 2010 AISC Spec, bolt shear strength values have been increased. RCSC still uses strength and serviceability separation for slip resistance. Laser, plasma, flame, etc. Must meet surface roughness limits 2

FOR END-LOADED CONNECTIONS ANSI/ AISC 360-10 TABLE J3.2 Nominal Stress of Fasteners and Threaded Parts 2005 2010 [b] End loaded connections with fastener pattern > 38 in., F nv = 83.3% of tabulated value 24 48 60 60 27 54 68 68 Pre-Installation Verification and Installation Requirements have been clarified Short-bolt usage of a DTI now permitted Difference between pre-installation values and installation values clarified 3

Snug-Tight Definition (OLD) Plies in firm contact Full effort of an ironworker with an ordinary spud wrench Snug-Tight Definition (NEW) the condition that exists when all of the plies in a connection have been pulled into firm contact by the bolts in the joint and all of the bolts in the joint have been tightened sufficiently to prevent the removal of the nuts without the use of a wrench. Not many changes SUMMARY New material specifications Revised bolt shear strength values Clarification of provisions The 2010 AISC Code of Standard Practice AISC 303-10 HIGHLIGHTS Scope Tolerances Structural Steel Drawing Information Pre-Detailing Conference Erection Drawings EOR Structural Narrative AESS Welds Option 3 Small Changes Big Change Appendix A: BIM Scope (Section 1.1) Buildings and Bridges (same as always) Other Structures added Consistent with AISC 360-10 (Specification for Structural Steel Buildings) 4

Tolerances (Section 1.9) Tolerances remain in Sections 6 and 7 Section 1.9 Added as invoking language Addresses tolerances not explicitly covered in the Code Tolerances not covered are not to be assumed as zero Structural Steel (Section 2.1) What is considered Structural Steel? Base plates vs. Bearing plates If attached to structural frame = Structural If loose items do not attach to structural frame = NOT Structural (loose lintels, etc.) Drawing Information (Section 3.1) Improved list of items that should be provided in the contract documents Works with information added on column differential shortening and anticipated deflections in the Commentary to Section 7.13 Pre-Detailing Conference (Section 4.1) Goal: To open lines of communication and develop a common understanding about the project Erection Drawings (Section 4.7) New section Similar requirements as for shop drawings Oriented toward ensuring the Erector has information when it is needed EOR Structure Narrative (Section 7.10.1) Example narratives added to Commentary Describes special erection conditions or other considerations that are required by the design concept Highlights special considerations in the erection of cantilevered members 5

AESS Welds (Section 10.2.5) Visual inspection of welds performed from the installed vantage point If you can t see it from where its installed, it doesn t matter Option 3 Delegated Connection Design Work Option 1 The complete connection design shall be shown in the structural design drawings The SER designs the connections Option 1 The intent of this approach is that complete design information necessary for detailing the connection is shown in the structural design drawings The steel detailer will then be able to transfer this information to the shop and erection drawings Option 2 The connection shall be designated to be selected or completed by an experienced steel detailer The SER provides the schematics and the steel detailer completes the details Option 2 It is not the intent that this method be used when the practice of engineering is required 6

Option 3 The connection shall be designated to be designed by a licensed professional engineer working for the fabricator The SER provides design criteria and a licensed professional engineer working for the fabricator designs the connections Mix-n-Match One of these options must be specified for each connection type Acceptable to use multiple methods on same project Communication Required Communication Required Communication Required Restrictions on types of connections Connection design loads and associated criteria must be defined Forces, moments, ASD or LRFD loads, and similar information is the key What substantiating connection information is required? (if any) Substantiating Connection Information Information submitted by the fabricator when option (2) or option (3) is designated for connections (if requested by the SER) Early on, the fabricator and SER need to discuss and agree on representative samples of the required substantiating connection information 7

Review and Approval The connection design engineer must review and confirm in writing, as part of the substantiating connection information, that the shop and erection drawings properly incorporate the connection designs Teamwork The SER is inviting the fabricator and the licensed professional engineer in responsible charge of the connection design to be a part of the SER s design team. This review does not replace the approval process of the shop and erection drawings by the SER, it is an addition to it Final Authority The SER is identified as the final authority in the case of a dispute between the SER and the licensed professional engineer in responsible charge of the connection design when option (3) is specified This is simple and straightforward, and it is how it must be because only the SER has the full knowledge of the structure SUMMARY Simple and straightforward approach to a practice that already exists, is in wide use, and currently is widely varying in how it is used Language allows all parties to control their own risks, and no party is asked to assume the responsibility for the negligence of another party The 2010 Specification for Structural Steel Buildings ANSI/ AISC 360-10 The 2010 AISC Specification AISC 360-10 AISC 360-10 AISC 360-05 AISC 360-10 8

ANSI/ AISC 360-10 HIGHLIGHTS K2. HSS-TO-HSS TRUSS CONNECTIONS 2005 Chapter N. Quality Control and Quality Assurance - Minimum requirements for QC, QA, and NDT Chapter J. Design of Connections - Bolt shear strength values increased - Chapter K. Design of HSS and Box Members Connections - Reorganized in a tabular format with figures K2. HSS-TO-HSS TRUSS CONNECTIONS 2010 2010 TABLE K1.1 Available Strengths of Plate-to-Round HSS Connections ANSI/ AISC 360-10 SUMMARY Minimal changes Most changes are simplifications Some changes add new capabilities Some changes increase economy ANSI/ AISC 360-10 The 2010 AISC Specification, 2010 Code of Standard Practice, and 2009 RCSC Specification are free for download at www.aisc.org/freepubs 9

The 14 th Ed. Steel Construction Manual is now available in the AISC online bookstore! A second option for the location of the branding A second title. option for the location of the branding title. AISC Regional Engineers For more information or to contact your regional engineer, log on to www.aisc.org/myregion AISC Upper Midwest Regional Engineer Monica Shripka, PE, LEED AP Senior Regional Engineer Southeast Region 312.804.3634 shripka@aisc.org 4444 N. Damen, 4W Chicago, IL 60625 www.aisc.org/myregion Thank You American Institute of Steel Construction One East Wacker Drive, Suite 700 Chicago, IL 60601 zuo@aisc.org A second option for the location of the branding A second title. option for the location of the branding title. There s always a solution in steel. 75 10