Multicare LE. Bed for critical care and ICU FOR HEALTHCARE



Similar documents
Healthcare Product PORTFOLIO

MINUET 2 COMMUNITY BED RANGE

Universal medical bed platform

USER MANUAL. Advanta Bed. From Hill-Rom. Product No. P1600

ArjoHuntleigh Universal Medical Bed Platform

Sicuro pesa. intensive care. The basis of. Clinic Care Homecare Assist

ENTERPRISE 8000 E8X RANGE

Stryker S3 Safe. Simple. Secure.

KS-70. Catheterization Table GENERAL

A Simple Guide to Health Risk Assessment Office Environment Series OE 5/2003

Compella Bariatric Bed Advancing bariatric care.

Spinal Cord Injury Education. An Overview for Patients, Families, and Caregivers

Patient handling techniques to prevent MSDs in health care

VersaCare Bed. Quick Reference Guide

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Dual Cushion User Manual. Specialist Suppliers to the Healthcare Industry

Maxi sky 600. with people in mind

NIMBUS range advanced MattreSS

ALENTI. with people in mind

PROdUcT specifications Pump Mattress Replacement ALPHA REsPONsE PREssURE REdIsTRIbUTION system Mattress Overlay seat cushion GETINGE GROUP

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

Oxygenation. Chapter 21. Anatomy and Physiology of Breathing. Anatomy and Physiology of Breathing*

Mobile, Powered Positioning Multi-Purpose. Stretcher-Chairs. A Universal Care Platform TMM4 Series

STANDARD OPERATING PROCEDURES (SOP) FOR COMPUTER WORK, DESK TOP

Maxi Sky 2 Plus The complete ceiling lift system

ACTIVE SEATING FOR PEOPLE WITH A KYPHOTIC SPINE. - backrest cushion for the kyphotic spine

Chapter 26. Assisting With Oxygen Needs. Elsevier items and derived items 2014, 2010 by Mosby, an imprint of Elsevier Inc. All rights reserved.

USER MANUAL. VersaCare Bed. From Hill-Rom. Product No. P3200 and P3201 USR119 REV 5

Info. from the nurses of the Medical Service. LOWER BACK PAIN Exercise guide

USER MANUAL. TotalCare Bariatric Bed. From Hill-Rom. Product No. P1830A

medical solutions ALTERNATING PRESSURE SYSTEMS FOR DECUBITUS PROPHYLAXIS AND THERAPY

Transferring Safety: Prevent Back Injuries

Basic Training Exercise Book

Working together to prevent pressure ulcers (prevention and pressure-relieving devices)

We at Kosmochem Home Healthcare focus on providing the range of Health, Fitness and Wellness Wll products for personal and professional use.

Section 14. Forklift Safety Contents 14.1 Operator Safety

ŠKODA MACHINE TOOL HORIZONTAL MILLING AND BORING MACHINES ŠKODA HCW

Active Pressure Relieving Systems

Systematic X-ray diagnostics as flexible and individual as your dental practice.

Proper Workstation Setup

Guidance for Manual Handling of Gas Cylinder

High Impact Intervention Care bundle to reduce ventilation-association pneumonia

Operations Manual Blast Chiller

Best Practice Guide Vehicle Ergonomics Best Practice Guide

BARIMAXX II THERAPY SYSTEM. with people in mind.

Electric profiling beds

Standard Operating Procedure for Handling an Inanimate Load

Basic techniques of pulmonary physical therapy (I) 100/04/24

Urinary Diversion: Ileovesicostomy/Ileal Loop/Colon Loop

Reviews of the latest healthcare furniture HEALTHCARE FURNITURE REVIEW

RESTWELL RISE & RECLINE ARMCHAIRS BORG - OWNER S HANDBOOK PARTS DESCRIPTION

MEDICAL SYSTEMS. Monnal T60. Touch and Breathe.

Equipment loan arrangements and loan form

Mistral, wellness in the air. Ovattificio Fortunato s.r.l. the soul of ideas

X-Plain Subclavian Inserted Central Catheter (SICC Line) Reference Summary

A small roller with a big effect. The mini roller for massaging, strengthening, stretching and warming up

IC Counterbalanced Lift Trucks H FTS Fortens / Fortens Advance

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.

PASSIVE ANTI-DECUBITUS MATTRESSES

GE Healthcare. Lullaby Warmer. Because every baby deserves a high standard of care

BODY FAT & HYDRATION % MONITOR SCALE

ERGONOMICS. Improve your ergonomic intelligence by avoiding these issues: Awkward postures Repetitive tasks Forceful exertions Lifting heavy objects

IMPORTANT INFORMATION - PLEASE READ. Table of Contents. Introduction. General Information

The height of the backrest can be adjusted with a simple push of a button.

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

Fredriksons conveyor systems handle goods with a width from 20 mm up to 600 mm.

ATLET ERGO STAND-ON STACKER AJN/ASN ERGONOMIC STAND-ON STACKERS FOR INTERNAL TRANSFERS AND STACKING IN WAREHOUSES, STORES AND PRODUCTION PREMISES

Agila Ceiling Supply Unit Medical Supply Units

BLADE S-MAX Cabinet for Blade Server

a patient s guide Physiotherapy advice and exercises from four weeks after neck dissection surgery

What is Separation of the Abdominal Muscles after Childbirth (also known as Divarication of Rectus Abdominis)?

@ EXU Technical Data Low Lift Pallet Truck. EXU 16 EXU 16 Li-Ion EXU 18 EXU 18 Li-Ion EXU 20 EXU 20 Li-Ion EXU 22 EXU-H 18 EXU-H 20

section 5 machine guarding and lockout

Enjoy a professional massage in the comfort of your own home. Introducing the Real Pro ULTRA Prestige. 3D Massage Elements

All About Your Peripherally Inserted Central Catheter (PICC)

Pneumatic tube systems in hospitals

Freezers - Ultrafreezers. Platilab & Irilab Series

MANAGING MANUAL HANDLING A Guide for Managers and Heads of Departments

a lift for the future

Nursing. Management of Spinal Trauma. Content. Objectives. Objectives

GoFit Platinum Power Vibe

OPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

Atlet Balance Electric Counterbalance trucks ET EF EH tons

MH 3M & 4M. High pressure washers with hot benefits

RISE & RECLINERS FEATURES & SPECIFICATION CHICAGO - STANDARD & PETITE PETITE MODEL NOW AVAILABLE

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

elearning at Ramsay Online Orientation Program Guide Version 2.0 Please any elearning questions to


SKELETON AND JOINTS G.C.S.E. PHYSICAL EDUCATION. Unit 1. Factors Affecting Participation and Performance. G.C.S.E. P.E. Teacher:.

HUR Rehab Line H E A L T H & F I T N E S S E Q U I P M E N T

A proper warm-up is important before any athletic performance with the goal of preparing the athlete both mentally and physically for exercise and

Equipment Manual. for. Operation of Automatic Polishing Plate Control on the PM5 Precision Lapping & Polishing Machine.

Better Breathing with COPD

KNEE EXERCISE PROGRAM

Move and position individuals in accordance with their plan of care

Long Term Tube Feeding. Sunnybrook. A Guide for Patients and Substitute Decision Makers VETERANS & COMMUNITY

Recommendations to improve the safety of existing lifts

Project 4.2.1: Heart Rate

Transcription:

Multicare LE Bed for critical care and ICU FOR HEALTHCARE

The Multicare LE bed offers an optimal solution to problems during hospitalisation in critical and intensive care units. The safety of the patient, support of vital functions, prevention of pressure ulcers, lung complications and suitable working conditions for the staff are subjects to which the Multicare LE responds by its progressive attributes.

Integrated safety concept The Multicare LE bed is designed for hospitalised critically ill patients while ensuring the safety of patients with various risks. The bed offers the patient protection concept which removes the risk of a fall and other bed-related injuries. The key element of the safety system is the siderails which provide protection based on the individual needs of each patient. Further sophisticated bed elements monitor the patient s safety the automatic I-Brake and multi-zone Bed Exit Alarm. [01] VARIABLE SIDERAIL SYSTEM FOR INDIVIDUAL ADJUSTMENT The unique siderail concept optimises care and protection depending on the risk rate and the patient s current condition. If the patient is indicated as being confused and high risk of sustaining a fall then the three-section siderail combination can be applied the standard head and central siderail is supported by the Protector at the foot end of the bed. The bed therefore has siderails that run the entire length of the mattress platform. A bed equipped with split siderails without a Protector provides most patients with standard protection. [01] HEIGHT OF THE SIDERAILS Given the above standard parameters of the siderails (45 cm in height) the bed is compatible with active and passive anti-decubitus mattresses. [02] MINIMUM GAPS MAXIMUM SAFETY The concept of minimum gaps reduces the risk of injury of a patient trapped between individual parts of the siderails and meets the latest standards. Even if the backrest is adjusted the space between the siderails remains constant. The space between the gaps meets the requirements of the EN 60601-2-52 strict safety standard. [02] [03] BED EXIT ALARM The multi-zone Bed Exit Alarm is part of the fall prevention system on the Multicare LE bed. The sensor is activated the moment the patient moves close to the edge of the bed and warns the patient and medical staff of the potential danger and possible risk of a fall. 4

[03] [04] [05] [06] [04] FALL PREVENTION AT THE LATERAL TILT Electronic sensors prevent the activation of the lateral tilt if the siderails are not in the safety position. [05] I-BRAKE Coming as part of the basic bed equipment the automatic I-Brake minimises the risks that may arise if the bed brake is not on. If the bed remains unbraked and is connected to the mains the I-Brake is automatically activated a minute later. [06] NURSE CALL The nurse call function prevents any dangerous situations by calling for the nurse s prompt assistance in urgent cases of patient care. 5

Serving nurses NURSING IS A PROFESSION that comes with a high risk of injury and back pain. The main cause is handling heavy loads patients. The bed s sophisticated functions can make these procedures significantly easier. [01] LATERAL TILT The lateral tilt turns the patient on his/her side with minimum physical effort. This function signifi cantly reduces the physical strain of nurses when handling the patient and removes the risk of work injury and back pain. It saves the time required for performing routine nursing work, provides more effective prevention of pressure ulcers and helps avoid complications in patients with lymphedema and facilitates post-operative drainage. It is easy for nurses to set the lateral tilt and safe for the patients. [01] [02] EASY TRANSPORT The fi fth castor makes it signifi cantly easier to manoeuvre the bed, stabilise the steering direction and makes it easy to turn the bed. Once the bed has been moved, the fi fth castor retracts to the undercarriage. It does not obstruct underpass equipment such as the C-arm, server or lift and cleaning. The ergonomic handles built into the bed ends also make it easier to move the bed. [02] 7

[a] [c] [d] [b]

Easier breathing THE PRIORITY OF THE ICU AND ACUTE CARE is to support vitally important functions respiration and heart activity. The Multicare LE bed facilitates their monitoring, contributes to easier respiration and supports the prevention of serious health complications affecting the respiration tract. [01] LATERAL TILT TO PREVENT PULMONARY COMPLICATIONS One of the important tasks of the ICU is the prevention of VAP (Ventilator Associated Pneumonia). The lateral tilt plays a particularly important role in this prevention. The right to left tilt results in the migration of fl uids from the more remote areas of the lungs to places where they can be removed by suction. [02] 30 HEAD OF BED The Multiboard central control panel located at the head end clearly indicates the setting of the backrest to 30 the clinically recommended position for the prevention of respiratory complications. This position can be set with one button on this panel. ORTHOPNEIC CHAIR [a] Sitting up position [b] Supported feet [c] Supported arms [d] Reduced pressure in the abdominal area The orthopneic chair position is designed mainly for patients with resting dyspnea. It combines a high Fowler s position (lungs are in the vertical position), reducing pressure on the internal organs for easier diaphragmatic breathing and allowing better use of additional breathing muscles. [01] [02] 9

Complex prevention of pressure ulcers Pressure ulcers are a complication that can be avoided. Careful positioning of the patient, reduction of pressure on the soft tissues and restriction of shear forces in changes in the bed s position are key aspects that the Multicare LE bed provides for prevention of pressure ulcers. [01] ERGOFRAME The Multicare LE mattress platform is equipped with the Ergoframe system which respects the natural movement of the human body during positioning and acts as prevention against pressure ulcers in the pelvic and sacral area. The Ergoframe extends the space in the parts at risk (the pelvic and sacral area) when the bed is positioned and signifi cantly reduces the pressure on the skin in this zone. Up to 40% of pressure ulcers appear in the pelvic and sacral area. Another major cause of pressure ulcers is the excessive friction between the mattress and the skin, and the stretching of the patient s skin on the back, especially the shoulder blades. The Ergoframe signifi cantly reduces these shear forces between the mattress and the skin. [02] LATERAL TILT Preventive regular positioning is the basic method of prevention. The lateral tilt turns the patient on his/her side with minimum physical effort. This function signifi cantly facilitates positioning and extends the range of positioning procedures. OPEN MATTRESS COMBINATION ARCHITECTURE The Multicare LE bed concept allows the use of a suitable anti-decubitus system based on the current condition and prognosis of a specifi c patient. The Virtuoso active mattress with its alternating pressure is designed for high risk patients. It works on the principle of alternating pressure in air cells. The pressure falls to zero in one of the three neighbouring cells in a 7.5 minute cycle. Equal pressure distribution Ergomatt foam mattresses or constant low pressure Symbioso 100 mattresses offer preventive anti-decubitus effects. All these systems are fully compatible with the Multicare LE bed and can be alternated randomly as required. [01] [02] 11

Support of patient mobilisation Effective cost management THE IMMOBILITY OF PATIENTS causes a number of secondary complications and is an obstacle for speedy convalescence. The integrated system of functions of the Multicare LE bed facilitates the mobility of patients and provides safe area for mobilisation. The Multicare LE bed provides maximum functionality in nursing practice, but also helps to make patient care costs more effective and reduces additional service and maintenance investments. [01] MOBI-LIFT HANDLE The Mobi-lift ergonomic mobilisation handles form part of the bed s mattress platform and provides stable support for the patient when leaving or sitting in the bed. There is a button integrated into the handle which the patient can use to set the bed at the suitable height. [03] INTELLIGENT BED The brain of the Multicare bed is an inner electronic system controlled by several microprocessors. It guards the safety of bed operations, activates automatic systems and ensures wireless communication with the LINIS information system. MOBILISATION HAND-GRIPS IN THE SIDERAILS The hand-grips integrated into the siderails help to actively involve the patient in the process of leaving the bed. [01] [03] LINIS The bed can communicate with other electronic systems. It transfers clinical, working and service data to the LINIS information system for further assessment. This way it is possible to observe selected therapeutic functions and perform remote service diagnostics. This allows quick service repairs at the customer s site without the bed having to be taken away. [02] MOBILISATION POSITION The optimum position for leaving the bed can be set by the press of one button on the control panel. This sets the bed s height so the patient s feet can reach the fl oor and the raised backrest provides him with the necessary support. Multicare Bed PC Statistics Alarm [04] QUALITY OF WORKMANSHIP AND ACCESSIBLE SERVICE Quality components, strict audits and internal inspections guarantee 100% quality of each manufactured bed during production. In view of the international network of its own branches and partnerships fi rms, LINET has service centres to cover all the products it supplies on a global scale. Service [02] [04] 12 13

Infection control Up to 30% of hospital infections can be avoided by suitable prevention. The construction and materials used to manufacture the Multicare LE bed allow easy and effective maintenance of all exposed surfaces. [05] COLUMN CONSTRUCTION The columns consist of smooth aluminium sections and the surface is treated so as little dirt as possible sticks to it. The sealing in the supporting columns prevents liquids from leaking inside the column and electric motor. The construction allows unlimited access to all parts of the bed. [05] [06] JOINT-FREE TECHNOLOGY The smooth surfaces of the bed are free of joints enabling quick decontamination and easy maintenance. The number of small parts in the bed s construction is minimised. The controls are located beyond the reach of patients therefore reducing the risk of their contamination. [06]

Innovation for greater effi ciency The bed s integrated function makes the work of hospital staff easier, increases the safety and efficiency of the work. The simple controls and maintenance enhances the efficiency of the nursing profession. [01] INTEGRATED SCALES The advanced weighing system integrated into the Multicare LE bed is capable of calculating the exact weight of the patient in all bed positions. This yields not just the current value of the patient s weight, but also displays the changes in the weight over time. The system contains the freeze function, enabling addition or removal of equipment from the bed (infusions, transport monitor) without any effect on the measurement of the patient s weight. [01] X-RAY IN THE BED The side X-ray cassette holder in the backrest allows safe imaging of the chest without having to move the patient in the bed. It is equipped with a cassette location system for precise location under the patient and allows imaging in portrait and landscape format. [02] C-ARM COMPATIBILITY The radiolucent mattress platform makes it possible to examine the patient using a C-arm from the pelvic and sacral area to the head. It makes it possible to perform invasive cardiologic procedures and examinations directly in the bed. [02]

Bed description [01] [01] MULTIBOARD is the main control element of the bed used to control all the bed functions. [02] [02] ERGOFRAME MATTRESS PLATFORM works preventively against the development of pressure ulcers and in the orthopneic position to facilitate breathing. [03] [11] [12] [08] FOOT CONTROLS For setting the height and lateral tilt of the bed. [09] I-BRAKE system of automatic braking of the bed. [03] INTEGRATED PATIENT CONTROL accessible in both the lying and sitting position. [05] [04] [10] SIDE HOLDER of small accessories. [04] BED FOOT-END can be adjusted by the electric motor allowing alteration of the bed s length. [06] [10] [11] MANUAL CPR POSITION ADJUSTMENT CONTROL for adjusting the backrest of the mattress platform. [05] NURSE ACP CONTROL PANEL this is an additional control element which can be moved to any position around the perimeter of the bed. [07] [08] [09] [12] SIDERAIL CONTROL with an integrated angle-meter. [06] MOBI-LIFT HANDLE designed for patient mobilisation. [07] ANCHOR POINTS for Segufi x patient restraints. TECHNICAL PARAMETERS ELECTRIC PARAMETERS CERTIFICATES LINET is certifi ed according to the European standards and quality system: EN ISO 9001:2000, EN ISO 13485:2003. Products are manufactured according to the European standards for healthcare and hospital beds: EN 60601-1, EN 60601-1-2, EN 60601-1-4, EN 60601-2-52, EN ISO 14971, 93/42/EEC, 90/384/EEC. External dimensions (shortest mattress platform position) 215 105 cm External dimensions (longest mattress platform position) 237 105 cm Mattress dimensions 208 86 cm Max. mattress height 23 cm Height adjustment 44 82 cm Lateral tilt ± 30 TR/ATR tilt 13 /16 Weight (basic equipment) 210 kg Safe working load 250 kg Power supply Maximum input Cover against water and dust Level of protection against electrical current Level of protection against injury from electrical current Electric motor operation mode (load factor) 230 V, ±10 %, 50 60 Hz 1,6 A, 370 VA IP X4 Class I Applied part type B 10%, max. 2 min/18 min 14 15

Multicare LE Bed for critical care and ICU Želevčice 5, 274 01 Slaný, Czech Republic tel.: +420 312 576 111, fax: +420 312 522 668, e-mail: info@linet.com, www.linet.com 16 01/2013 9601 1030