EL-USB-TC-LCD Thermocouple Data Logger with LCD and USB Interface

Similar documents
EL-USB-1-LCD Temperature Data Logger with LCD

EL-USB mA Current Loop USB Data Logger


EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

USB-500 Series Stand-Alone, Low-Cost Data Loggers

USB-500 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories

Data Logging Solutions from Lascar Electronics

DataView DVTH Data Logger for Temperature and Humidity

USER S GUIDE Humidity and Temperature USB Datalogger

SupcoLog Logger Interface Software

Data Loggers for Real Time Temperature Monitoring - WiFi

Current Monitoring Kit

Current Monitoring Kit QUICK START GUIDE

Temperature Datalogger Users Manual

S P E C I F I C A T I O N F O R L I T H I U M B A T T E R Y. M o d e l : C R

HOBO Single Channel Thermocouple Data Logger (UX M) Manual

4-Channel Thermometer / Datalogger

PTR/DTR. Printing Thermometer Software. Software User Manual

Datalogger Graph Software Help

User's Guide. Integrating Sound Level Datalogger. Model Introduction

User Guide. Temperature and Humidity Datalogger. Model 42280

1. SAFETY INFORMATION

Ron 3025 Crane Scale with 1"/25mm Display

RS DIGITAL THERMOMETER

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

This datalogger is ideal for the Food Industry where process profiling is crucial to production efficiency and energy use optimisation.

USB-Based Temperature & Humidity Sensor

SNMP Web Management. User s Manual For SNMP Web Card/Box

5000V Graphical Megohmmeter Model 5070

TFA. KlimaLogg Pro. User Manual. Revision: 0.1

SA-9600 Surface Area Software Manual

HOBO U14 Data Logger User Manual

HT580 User Reference Guide. Version 1.0

Integrating Sound Level Meter and Datalogger

SoundLAB Software Download Software from the Bogen website:

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

DC Electronic Loads 8500 series

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Changers Kalhuohfummi User Manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

3½ DIGIT VOLTMETER MODULE LED- / LCD- SERIES

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

HWg-STE HWg-STE PoE MANUAL

Table of Contents Appendix 4-9

FT-1000/GPS-N. System of remote monitoring and control of physical

Instruction Manual. T3111 T3111L T3111P T3111Ex

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

Data Logger Basics For VFC Providers. Montana Immunization Program

GX-2009 Data Logger Management Program Operator s Manual

User's Guide DylosLogger Software Version 1.6

Single Use USB Data Logger EBI 330-T30 / EBI 330-T85. User Manual

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

USB Smart Power Sensor

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

User Guide Reflow Toaster Oven Controller

Dual Laser InfraRed (IR) Thermometer

SHENZHEN JUNSI ELECTRONIC CO.,LTD

Temperature & Humidity SMS Alert Controller

Hand-held thermometer Model CTH7000

Preparing Log-ic 360 USB Loggers for Use

Manual. CANcaseXL CANcaseXL log. Version 5.1 English

Model UT201/202: OPERATING MANUAL. Table of Contents

GSM HOME SECURITY SYSTEM

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

User's Guide Integrating Sound Level Datalogger Model

BTMPico Data Management Software

Drayton Digistat +2RF/+3RF

Routefinder Testing and reporting for emergency lighting systems

Handheld portable appliance testers

USBSPYDER08 Discovery Kit for Freescale MC9RS08KA, MC9S08QD and MC9S08QG Microcontrollers User s Manual

Disturbance Recoder SPCR 8C27. Product Guide

Multi-Function Ground

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Wireless Data Logger Monitoring Systems

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Quick start guide smart.power smart.power smart.power

ACR880 GPRS Portable Smart Card Terminal

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

Product information and manual for SensLab BT-Adapter (Model type: BT060721) for wireless data transfer of measurement data of Lactate Scout-handheld

USER MANUAL V5.0 ST100

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

RFID Logger Software User Manual Rev 1.0

Keep it Simple Timing

USB Smart Power Sensor

DG-100 Data Logger User Manual. Version 1.2

ExStik TM ph Waterproof Meters

EDIC-mini TINY Model SOLAR 1120/2240/4480/8960/17920

Speedlink software will run on Windows NT, Windows 7, and Windows 8; it will run on both 32 byte and 64 byte versions of Windows.

Transcription:

Thermocouple Data Logger with LCD and USB Interface ORDERING INFORMATION Standard Data Logger EL-USB-TC-LCD (Data Logger, Measurement Leads, Software on CD and Battery) Replacement Battery K-type Probe BAT 3V6 1/2AA K-TYPE PROBE 1M5 FEATURES -200 to +1350ºC (-328 to +2462ºF) K-type measurement range -200 to +1190ºC (-328 to +2174ºF) J-type measurement range -200 to +390ºC (-328 to +734ºF) T-type measurement range High contrast LCD, with four digit temperature display USB Interface for set-up and data download User-programmable alarm thresholds Status indication via red and green LEDs Immediate, delayed and push-to-start logging Supplied with basic K-type thermocouple rated from 0 to 400 C (32 to 752 F) Supplied complete with replaceable internal lithium battery and Windows control software This standalone data logger measures and stores up to 32,510 temperature readings from either a K, J or T type thermocouple. A thermocouple is attached via the thermocouple socket at the base of the unit. The user can easily set up the logging rate and start-time, and download the stored data by plugging the data logger into a PC s USB port and running the purpose designed software under Windows 2000, XP, Vista or 7. Data can then be graphed, printed and exported to other applications. The high contrast LCD can show several different temperature variables. The user can cycle between these using the push button. The data logger is supplied complete with a long-life lithium battery, which can typically allow logging for up to 6 months. Specifications Minimum Typical Maximum Unit Probe Measurement range (K-type) -200 (-328) +1350 (+2462) C ( F) Probe Measurement range (J-type) -200 (-328) +1190 (+2174) C ( F) Probe Measurement range (T-type) -200 (-328) +390 (+734) C ( F) Operating temperature range * -10 (+14) +40 (+104) C ( F) Resolution (internal and displayed) 0.5 (1) C ( F) Accuracy (logger error) ±1 (±2)** C ( F) Logging rate every 1 s every 12 hr - 1/2AA 3.6V Lithium Battery Life 6*** Month * Operating temperature applies to the data logger module only. Please consult the probe manufacturer for operating temperature of thermocouple. ** Quoted accuracy is for the data logger only and excludes the thermocouple probe. Thermocouple error should also be taken into consideration. *** Depending on sample rate, ambient temperature and use of LCD. Specifications liable to change without prior warning Issue 4 07/2012 S.L Applies to EL-USB-TC-LCD Page 1 of 6

WINDOWS CONTROL SOFTWARE Lascar s EasyLog USB control software is supplied free of charge with each data logger. Easy to install and use, the control software runs under Windows 2000, XP, Vista or 7. The software is used to set-up the data logger as well as download, graph and export data to Excel. The software allows the following parameters to be configured: Logger name C, F Logging rate (1s, 10s, 1m, 5m, 30m, 1hr, 6hr, 12hr) High and low alarms Immediate, delayed and push-to-start logging Display off, on for 30 seconds after button press, or permanently on Data rollover (Allows unlimited logging periods by overwriting the oldest data when the memory is full) The latest version of the control software may be downloaded free of charge from YOUR THERMOCOUPLE The probe supplied with your EL-USB-TC-LCD is a K-type thermocouple designed to measure temperatures from 0 to 400ºC (32 to 752ºF). The EL-USB-TC-LCD is designed to work with J, K and T-type thermocouples fitted with a standard mini thermocouple connector; this makes your data logger compatible with a wide range of available thermocouples. Your application will determine which probe is most suitable based on temperature range, accuracy, form and price. For information on a wide variety of alternative thermocouples, please contact the following companies: UK RS Components (www.rs-components.com) Farnell (www.farnell.com) Helium Projects (www.helium.uk.net) TC Ltd (www.tc.co.uk) USA Omega (www.omega.com) Allied Electronics (www.alliedelec.com) Newark Electronics (www.newark.com) Type Temperature Range C Temperature Range F Connector Coding ANSI IEC K -200 to +1350-328 to +2462 J -200 to +1190-328 to +2174 T -200 to +390-328 to +734 Specifications liable to change without prior warning Issue 4 07/2012 S.L Applies to EL-USB-TC-LCD Page 2 of 6

DISPLAY AND STATUS FUNCTIONS The EL-USB-TC-LCD features a high contrast LCD and two LEDs. The LCD shows logged temperature values using seven segment numbers, along with symbols. The LCD can also show information regarding the logging status. Temperature scale symbols Reading Maximum/Minimum logged value symbol Three different functions are available on the display most recent logged temperature, maximum logged temperature and minimum logged temperature. The push button is used to cycle through the functions. In addition, logging and alarm status are shown using two high intensity LEDs. LCD INDICATION Display Logger Status Explanation Delayed Start This is shown when the logger is set to start at a specific data and time* Push to Start This is shown when the logger is setup for Push to start logging Logging Stopped This is shown when the logger is running in LCD off mode, and the button is pressed. The display clears again after three seconds If the logger has not been set to log and the button is pressed, three dashes are displayed for three seconds * If the logger is set to LCD off or LCD on for 30 seconds mode, then this will only be shown after the button is pressed. Otherwise the display will remain blank. Specifications liable to change without prior warning Issue 4 07/2012 S.L Applies to EL-USB-TC-LCD Page 3 of 6

LED FLASHING MODES EL-USB-TC-LCD features two LEDs that indicate the logging, battery and alarm status: The first LED flashes red (R) to indicate that the EL-USB-TC-LCD is in an alarm condition. It will flash when the logged temperature has exceeded a Low or High alarm level. The second LED flashes green (G) to indicate that the EL-USB-TC-LCD is not in an alarm condition. Hold is enabled by default, which forces the logger to continue flashing the red LED after an alarm, even when the temperature has returned to normal. This feature ensures that the user is notified that an alarm level has been exceeded, without the need to download the data from the logger. Hold can be turned off via the control software. The red LED will then only flash whilst the logger is in an alarm condition. When the temperature returns to normal, the green LED will flash. Additional LED modes are explained below: Green single flash (10 seconds) The data logger is currently logging. No alarm. Green single flash (20 seconds) The data logger is currently logging. No alarm. However, the battery is low and should be replaced before logging important data. Green single flash (30 seconds) The data logger is not currently logging, but is primed to start at a later date and time (delayed start). Green double flash (20 seconds) The data logger is full and has stopped logging. No alarm. Red single flash (10 seconds) The data logger is currently logging. Low alarm. Red single flash (20 seconds) The data logger is currently logging. Low alarm. However, the battery is low and should be replaced before logging important data. Green LED Red LED Red double flash (10 seconds) The data logger is currently logging. High alarm. Red double flash (20 seconds) The data logger is currently logging. High alarm. However, the battery is low and should be replaced before logging important data. Red/Green single flash (20 seconds) The data logger is full and has stopped logging. Alarm (high, low or both). No LEDs flash The data logger is stopped, the battery is empty or there is no battery fitted. Specifications liable to change without prior warning Issue 4 07/2012 S.L Applies to EL-USB-TC-LCD Page 4 of 6

DIMENSIONS All dimensions in mm (inches) 23.9 (0.94) 21.2 (0.83) 134.5 (5.29) BATTERY REPLACEMENT We recommend that you replace the battery every 6 months, or prior to logging critical data. The EL-USB-TC-LCD does not lose its stored readings when the battery is discharged or when the battery is replaced; however, the data logging process will be stopped and cannot be re-started until the battery has been replaced and the logged data has been downloaded to a PC. Check with your supplier that the battery you are ordering is press fit and is not fitted with solder tags. Before replacing the battery, remove the EL-USB-TC-LCD from the PC. Note: Leaving the EL-USB-TC-LCD plugged into the USB port for longer than necessary will cause some of the battery capacity to be lost. WARNING Handle lithium batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. Specifications liable to change without prior warning Issue 4 07/2012 S.L Applies to EL-USB-TC-LCD Page 5 of 6

THE EASYLOG USB RANGE Each EL-USB data logger features the direct-to-usb connection and easy-to-use functionality that the range is known for. The range comprises of the following data loggers: Part No Function Range Accuracy (overall error) Typ. Max. Readings Battery Battery Life* EL-USB-1 Temperature ±1ºC (±2ºF) 16,382 3.6V ½AA 1 Year EL-USB-1-LCD Temperature with LCD ±0.5ºC (±1ºF) ±1.5ºC (±3ºF) 16,382 3.6V ½AA 1 Year EL-USB-1-PRO High Temperature -40 to +125 C (-40 to +257 F) ±0.2ºC (±0.4ºF) ±0.5ºC (±1ºF) 32,510 3.6V ⅔AA 3 years EL-USB-1-RCG EL-USB-2 EL-USB-2+ EL-USB-2-LCD Temperature with rechargeable battery Temperature, humidity & dew point Increased accuracy temperature, humidity & dew point Temperature, humidity & dew point with LCD -20 to +60 C (-4 to +140 F) ±1ºC (±2ºF) 32,510 Lithium Ion ±0.5ºC (±1ºF) ±3%RH ±0.3ºC (±0.6ºF) ±2.0%RH ±0.5ºC (±1ºF) ±3.0%RH ±2ºC (±4ºF) ±6.0%RH ±1.5ºC (±3ºF) ±4.0%RH ±2ºC (±4ºF) ±6.0%RH 1 month (rechargeable) 16,382 3.6V ½AA 1 year 16,382 3.6V ½AA 1 year 16,379 3.6V ½AA 1 year Increased accuracy temperature, ±0.3ºC (±0.6ºF) ±1.5ºC (±3ºF) EL-USB-2-LCD+ humidity & dew 16,379 3.6V ½AA 1 year point with LCD ±2.0%RH ±4.0%RH EL-USB-3 Voltage 0 to 30V d.c. ±1% 32,510 3.6V ½AA 1 year EL-USB-4 Current loop 4 to 20mA ±1% 32,510 3.6V ½AA 1 year EL-USB-5 Counter, Event & State N/A ±3 secs/24 hrs 32,510 3.6V ½AA 1 year EL-USB-TC Thermocouple (J, K and T- type) K-type probe included -200 to +1350ºC (-328 to +2462ºF) (K-type) -200 to +1190ºC (-328 to +2174ºF) (J-type) -200 to +390ºC (-328 to +734ºF) (T-type) ±1ºC (±2ºF) 32,510 3.6V ½AA 6 months -200 to +1350ºC (-328 to +2462ºF) (K-type) EL-USB-TC-LCD Thermocouple with LCD (J, K and T-type) K-type probe -200 to +1190ºC (-328 to +2174ºF) (J-type) ±1ºC (±2ºF) 32,510 3.6V ½AA 6 months included -200 to +390ºC (-328 to +734ºF) (T-type) EL-USB-CO Carbon monoxide 0 to 1000ppm NOT A LIFE SAVING DEVICE ±6ppm 32,510 3.6V ½AA 3 months EL-USB-CO300 Carbon monoxide 0 to 300ppm NOT A LIFE SAVING DEVICE ±4ppm 32,510 3.6V ½AA 3 months EL-USB-LITE Low cost temperature -10 C to +50 C (+14 to +122 F) ±1ºC (±2ºF) 4,080 CR1620 Lithium coin cell 1 month EL-USB-RT Real-time temperature & humidity monitor -20 to +70 C (-4 to +158 F) *Depending on logging rate, ambient temperature, and use of alarm LED ±1.5ºC (±3ºF) ±4.5%RH 7 days N/A N/A Module House Whiteparish, Salisbury Wiltshire SP5 2SJ UK T +44 (1794) 884567 F +44 (1794) 884616 E sales@lascar.co.uk 4258 West 12th Street Erie PA 16505 USA T +1 (814) 835 0621 F +1 (814) 838 8141 E us-sales@lascarelectronics.com 8th Floor, China Aerospace Centre 143 Hoi Bun Road Kwun Tong, Kowloon HONG KONG T +852 2797 3219 F +852 2343 6187 E saleshk@lascar.com.hk Specifications liable to change without prior warning Issue 4 07/2012 S.L Applies to EL-USB-TC-LCD Page 6 of 6